Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prostheses and Implants”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

The effect of surface coating of femoral prostheses implanted without cement: a 2- to 4-year follow-up study.

A randomized, concurrently controlled, prospective, single-blinded, multicenter study was done to evaluate the effect of proximal surface coating of a femoral prosthesis on clinical and radiographic results of cementless total hip arthroplasty (THA). The Profile femoral prosthesis (DePuy, Warsaw, IN), an anatomic titanium alloy stem, was used in one of three configurations: (1) smooth, (2) porous coated, or (3) hydroxyapatite (HA) coated. Ninety-one cases were enrolled in the study, with seven cases lost to follow-up and 79 cases available for clinical review with 24- to 48-month follow-up. The study shows that HA-coated stems performed as well, if not better than, porous-coated or smooth stems. Results show HA-costed stems with statistically superior total Harris hip scores (microHA = 96.0) than smooth stems (microS = 85.1) (Student's t-test, P = 0.004). This was primarily due to differences between the functional score of the two groups (microHA - 31.6; microS = 27.9, P = 0.003). Porous-coated stems were intermediate in performance (microPC = 89.8), with hip scores that were statistically indistinguishable from both smooth and HA-coated stems. Our data support the hypothesis that clinical differences exist and are attributable to the type of surface coating used for the cementless femoral components in THA.

Adult↗

Finite element analysis on dental implant-supported prostheses without passive fit.

PURPOSE: The purpose of this study is to use finite element analysis to investigate the effect of misfit prostheses, cantilever prostheses, and various occlusal forces on the stress distribution in the prostheses, implant components, and surrounding bone. MATERIALS AND METHODS: Two 3-dimensional finite element models were constructed: (1) a 2-implant-supported, 2-unit fixed partial denture and (2) a 2-implant-supported, 2-unit fixed partial denture with a distal cantilever. Variations of the standard finite element models were made by placing a 111-microm gap between the gold cylinder on either the mesial or distal implant. The effects of load of 100 N were tested on all models. Subsequently, loads of 50 N, 200 N, and 300 N were evaluated on the cantilever model. RESULTS: When the gap was positioned near to the applied force, the stress in both models increased significantly in the implant components and surrounding bone. The stress increase in each component ranged from 8% to 64% in the non-cantilever models and 43% to 85% in the cantilever models. The greatest stress was found in the distal gold screw. The effect of the gap was clearly shown by the pattern of stress distribution in both models. Additionally, the presence of a cantilever and excessive occlusal force amplified the effect of prosthesis misfit. CONCLUSIONS: Prosthesis misfit influenced the pattern and magnitude of stress distribution in the prosthesis, implant components, and surrounding bone, and the presence of the cantilever or greater occlusal force amplified the effect of misfit.

Bite Force↗

Treatment outcomes of patients with implant-supported fixed partial prostheses.

Implant and prosthesis success for 77 partially edentulous patients, provided with 97 fixed prostheses, supported by 230 Brånemark implants, in place for up to 12 years (mean 5.41 years), were documented in this study. Implant losses per location mirrored their placement, with no difference between zones I and II or between the maxilla and mandible. The implant success rate was 94%, and continuous prosthesis stability was 97%. These results indicate that the Brånemark implant-supported fixed partial prosthesis is a highly efficacious treatment.

Acrylic Resins↗

Maxillofacial prosthetics and the head and neck cancer patient.

The rehabilitation of cancer patients has been an important aspect of patient care in recent decades. Disabilities resulting from acquired surgical defects in the head and neck area frequently are corrected by using nonliving substitutes or prostheses. A number of specialists in the prosthetic reconstruction of head and neck patients, namely maxillofacial prosthodontists, have been trained over the past 20 years. Now more large metropolitan areas have these services available for cancer patients. In addition, pertinent research in materials and design has resulted in a whole array of possible prostheses that can be constructed to meet specific patient needs. Both the current state of the art in maxillofacial prosthetics and recent advances are highlighted in this paper. The areas covered are: extraoral (facial) prostheses, intraoral prostheses, implant prostheses, and treatment prostheses. The multidisciplinary nature of head and neck cancer patient rehabilitation is also reviewed.

Dentures↗

Implant prosthodontics: from single tooth to complex cases.

Types of commonly used implant prostheses have been described and illustrated, including single tooth replacements, multiple tooth replacement fixed prostheses, implant and soft-tissue-supported removable complete dentures, implant-supported removable complete dentures, and fixed-detachable complete dentures.

Crowns↗

Implant-protected occlusion: a biomechanical rationale.

The clinical success and longevity of endosteal dental implants are controlled, in a large part, by the mechanical milieu within which they function. The occlusion is a critical component of such a mechanical environment. "Implant-protected occlusion" refers to an occlusal schema that is often uniquely specific to the restoration of endosteal implant prostheses. Implant orientation and the influence of load direction, the surface area of implants, occlusal table width, and protecting the weakest area are blended together from a biomechanical rationale to provide support for a specific occlusal philosophy.

Alveolar Process↗

An audit of implanted penile prostheses in the UK.

OBJECTIVE: To assess whether the outcome of implanting penile prostheses is related to the number of prostheses implanted by surgeons, as several reports showed that the outcome of a urological procedure is directly related to the experience of the surgeon. METHODS: We conducted a retrospective audit of 413 penile prostheses implanted over a 2-year period in the UK by 76 surgeons. RESULTS: About 80% of the surgeons implanted only one or two prostheses per year, usually of the malleable type, and usually on patients in the private sector. Only four surgeons implanted >20 prostheses per year. The overall revision rate for implantation in the UK, at 24%, is far higher than the worldwide average. CONCLUSIONS: Guidelines are needed on the number of prostheses a surgeon should implant per year so that revision rates will decline to more acceptable levels and patients will be offered a genuine choice of product.

Erectile Dysfunction↗

Ten-year results for Brånemark implants immediately loaded with fixed prostheses at implant placement.

This investigation was initiated to develop a method to provide patients with a fixed provisional prosthesis placed at the time of implant placement. Sixty-three standard 3.75-mm Nobel Biocare implants of varying lengths were placed into mandibular sites in 10 patients and followed for up to 10 years. Twenty-eight implants were immediately loaded at implant placement, providing support for fixed provisional prostheses, while 35 adjacent implants were allowed to heal submerged and stress-free. Following a 3-month healing period, the submerged implants were exposed and definitive reconstruction was accomplished. All 10 prostheses supported by 28 implants placed into immediate function at the time of implant placement were successful during the 3-month healing period. Of these 28 implants placed into immediate function, 4 ultimately failed. Of the 35 submerged implants, all are osseointegrated and in function to date. Life-table analysis demonstrates an overall 10-year survival rate of 93.4% for all implants. The 10-year life-table analysis of survival is 84.7% for immediately loaded implants and 100% for submerged implants. Statistical analysis of the submerged versus immediately loaded implants demonstrates failure rates for immediately loaded implants to be significantly higher (P = .022 by the log rank test). These data demonstrate that although mandibular implants can be successfully placed into immediate function in the short term to support fixed provisional prostheses, long-term prognosis is guarded for those implants placed into immediate function distal to the incisor region.

Aged↗

Hygiene procedures for implant-retained facial prostheses.

Implant-retained facial prostheses offer several advantages over facial prostheses that are retained with conventional skin adhesive. However, implant-retained prostheses also require additional hygiene procedures to maintain them in good condition and to keep the implants and retentive elements free of debris and the surrounding skin healthy. This article describes additional hygiene procedures to maintain the implant-retained prostheses.

Adhesives↗

Immunohistochemical study of clinical skin-penetrating titanium implants for orthopaedic prostheses compared with implants in the craniofacial area.

The technique of using osseointegrated bone-anchored percutaneous titanium implants in the rehabilitation of patients with amputated limbs has recently been introduced at the Brånemark Osseointegration Centre in Göteborg. The new method is based on an implantation technique that is well-established for anchorage of bone-conductive hearing aids and craniofacial prostheses. The soft tissues around skin-penetrating titanium implants used to anchor orthopaedic prostheses were evaluated histochemically using quantitative analyses. The implants had been in clinical use for between 6 to 24 months. The number of inflammatory cells was higher in the area close to the interface than in the area distant from the skin-penetrating site, and higher than in the corresponding controls. The current data was also compared with corresponding data from tissue around skin-penetrating craniofacial implants. The number of inflammatory cells was lower in the orthopaedic samples than in the craniofacial specimens. We conclude that skin-penetration of orthopaedic implants is as safe as when titanium implants are used for craniofacial rehabilitation, which is a clinically well-established procedure.

Adult↗

Surgery of the penis: reconstruction and prostheses.

Implantation of penile prostheses was a very popular topic in the published literature on reconstructive urological surgery in the year 2000. Monocomponent, multicomponent, semirigid and inflatable prosthesis techniques were investigated. The best results were obtained with multicomponent inflatable prostheses. For penile reconstruction, various techniques were described. All authors used myocutaneous sensitive forearm flaps. Good results were reported.

Humans↗

An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients.

PURPOSE: Implant length, implant surface area, and crown-to-root (c/r) ratio and their relationship to crestal bone levels were analyzed in 2 groups of partially edentulous patients treated with sintered porous-surfaced dental implants. MATERIALS AND METHODS: One hundred ninety-nine implants were used to restore 74 partially edentulous patients with fixed prostheses. Implants were categorized according to their length ("short" versus "long") and estimated surface area ("small" versus "large"). "Short" implants had lengths of 5 or 7 mm, while "long" implants were either 9 or 12 mm in length. "Small" implants had estimated surface areas of < or = 600 mm2, while "large" implants had estimated surface areas > 600 mm2. Other data collected included c/r ratio (measured on articulated diagnostic casts), whether or not the implants were splinted, and standardized sequential radiographs. RESULTS: The mean c/r ratio was 1.5 (SD = 0.4; range 0.8 to 3.0), with 78.9% of the implants having a c/r ratio between 1.1 and 2.0. Neither c/r ratio nor estimated implant surface area (small or large) affected steady-state crestal bone levels. However, implant length and whether the implants were splinted did appear to affect bone levels. Long implants had greater crestal bone loss (0.2 mm more) than short implants; splinted implants showed greater crestal bone loss (0.2 mm more) than nonsplinted ones. These differences were statistically significant. DISCUSSION AND CONCLUSIONS: Sintered porous-surfaced implants performed well in short lengths (7 mm or less) in this series of partially edentulous patients. The data suggested that long implants and/or splinting can result in greater crestal bone loss; longer implants and splinted implants appeared to favor greater crestal bone loss in this investigation. These conclusions are, of course, specific to the implants used and would not be relevant to other implant types.

Adult↗

Problems with prostheses on implants: a retrospective study.

Prosthetic parameters for implant success have not been well defined but should include patient satisfaction and prosthesis maintenance, including adjustments and repairs. In addition, differences between fixed and removable implant-supported prostheses (ISPs) should be quantified. This study retrospectively evaluated both patient satisfaction and maintenance for 156 patients. Removable ISPs averaged almost three times as many adjustments per prosthesis (2.1 versus 0.8 per fixed ISP) and more than twice as many repairs (1.9 per removable ISP versus 0.9 per fixed ISP). The most common adjustments were to the contour of both types of prosthesis, and the most frequent repairs involved the retentive clips with removable ISPs and the gold screws with fixed ISPs. The incidence of repeat repairs was more than twice as high with removable prostheses compared with fixed prostheses. However, the repairs to opposing dentures most often needed were for conventional dentures opposing fixed ISPs. The vast majority of repairs were needed within the first year of service. Despite the high maintenance needed, patients were satisfied with both types of ISP, with the exception of limited satisfaction with cleansability, particularly with fixed restorations. The high incidence of early repairs, and the greater potential for a removable ISP requiring adjustment and repair, should be considered both when discussing options with the patient and when estimating treatment and maintenance costs before the commencement of implant therapy.

Adult↗

[The role of endoprostheses in the scope of hand surgery. Endoprostheses vs. traditional surgical procedures].

Alloarthroplasty has largely replaced traditional procedures in arthrosis of hip and knee joints. In contrast the role of alloarthroplasty in comparison to traditional procedures in hand surgery has been uncertain. To evaluate this question every registered hand surgery department (n=307) in Germany received a questionnaire requesting information on number and type of implanted prostheses and traditional procedures concerning the wrist joint, distal radioulnar joint (DRUJ), first carpometacarpal joint (CMC), metacarpal phalangeal joint (MP), interphalangeal joint (PIP), and preferred characteristics of the prostheses. Of the 307 hand surgery departments, 150 (57% of the hospitals and 42% of the visiting surgeons) participated in the inquiry. Per year, only 98 wrist prostheses were implanted (distributed among five different models) but 1534 traditional procedures were performed. The Sauve-Kapandji procedure was the most popular for the DRUJ and was performed 264 times per year. In comparison 24 hemiarthroplasties were implanted at the DRUJ. Trapezectomy remains the standard procedure for arthrosis of the first CMC joint (n=1399). The future importance of alloarthroplasty of the CMC joint is doubted by the majority of participating hand surgeons (90.3%). In contrast the majority (85.3/71.8%) is convinced that alloarthroplasty will be of importance for the MCP and PIP joints, respectively. Currently, the number of implanted prostheses is close to the number of traditional procedures performed at the MP joint. Irrespective of the joint involved, cementless anchorage is preferred as is the surface replacement anatomical design. The results confirm that alloarthroplasty in hand surgery is of minor importance. Thus, the role of alloarthroplasty differs depending on the joint involved. Traditional procedures except for the MP joint continue to be of major importance in hand surgery.

Arthroplasty, Replacement↗

The influence of oral implant-supported prostheses on articulation and myofunction.

The aim of the present research was to assess articulation and myofunction in patients wearing fixed or removable prostheses supported by oral implants. 164 edentulous patients with implant supported prostheses were divided in four subgroups, dependent on their dental status, and compared to control groups of forty five subjects having a natural dentition. More than fifteen articulatory and myofunctional parameters were evaluated. The results showed that subjects with prostheses on implants tend to have more articulation problems than controls. Especially patients with a complete fixed prosthesis on implants in the upper jaw seemed to experience problems pronouncing /s/ and /z/. There also seemed to be influences of age and hearing factors.

Adult↗

The transitional phases of implant-perio-prostheses with root-form implants.

The functional, aesthetic and periodontal integrity of any implant reconstruction depends on good prosthetic planning. Three clinical concepts used to increase control and the predictability of prognosis and outcome are described in this article: the use of templates in the early phase of treatment, temporization or provisionalization during the second transitional phase, and "jumping" the case in the final transitional phase.

Dental Implantation, Endosseous↗