Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polygeline”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Role of brain angiotensin II in renal nerve inhibition elicited by volume expansion in the conscious rabbit.

Losartan (10 microg/25 microl) or vehicle was injected into the fourth brain ventricle prior to volume expansion (VE) with Haemaccel (2 ml/min for 30 min). RSNA was reduced by a maximum of 45% in response to the VE following vehicle and by 33% following losartan. There was no significant difference between the treatments in RSNA, nor in the blood pressure and heart rate responses. We conclude that endogenous angiotensin II does not make a major contribution to the reflex reduction in RSNA initiated by VE.

Angiotensin II↗

Cardiopulmonary effects of 7.2% saline solution compared with gelatin infusion in the early postoperative period after coronary artery bypass grafting.

OBJECTIVE: We report a clinical study on the use of 7.2%, 2400 mOsm/L, hypertonic saline solution compared with gelatin in early postoperative period after coronary artery bypass surgery. METHODS: Two groups (n = 10 each) received 5 ml/kg of either saline solution or gelatin over 1 hour. Cardiac index, central venous pressure, pulmonary capillary wedge pressure, systemic and pulmonary vascular resistance indices, arterial oxygen tension, plasma osmolarity, electrolytes, and urinary output were recorded before starting the infusion and subsequently at 10, 30, 60, 90, 120, 240 and 600 minutes. Plasma creatinine, urea, electrolytes, urinary volume, and sodium excretion were measured at 12 and 24 hours. RESULTS: There were no significant demographic or operative difference between the groups. Patients receiving saline solution had a larger diuresis at 12 (p = 0.0008) and 24 hours (p = 0.002), with less positive balance at 12 hours (p = 0.0008). The group receiving saline solution had better cardiorespiratory recovery with shorter extubation time (p = 0.033), and earlier increase in cardiac index with a positive correlation between plasma sodium content and cardiac index. Maximum increase in cardiac index (+31%) occurred at 60 minutes (p = 0.025) associated with 8% increase in plasma sodium content (r = 0.51, p = 0.01), without a concomitant rise in pulmonary capillary wedge pressure. The group receiving gelatin had a linear increase in cardiac index with increasing pulmonary capillary wedge pressure, reaching +16% from baseline by 90 minutes. Compared with the gelatin-treated group, patients receiving saline solution had unchanged systemic vascular resistance index but a significantly lower pulmonary vascular resistance index with a negative correlation to plasma sodium content. There was no difference in levels of urea and creatinine. No side-effect attributable to the use of saline solution was observed.

Coronary Artery Bypass↗

Microparticle-containing oncotic solutions augment in-vitro clot disruption by ultrasound.

Echocardiographic contrast agents enhance blood clot disruption by ultrasound. It has been suggested that the microbubbles add nuclei for the enhancement of cavitation by ultrasound. However, microbubbles are rapidly destroyed by the ultrasound energy. We assessed whether non-gas filled colloidal solutions (hyperoncotic medium molecular hydroxyethyl starch and degraded gelatin polypeptides) will facilitate clot disruption by ultrasound. In two separate experiments human blood clots, 200-400 mg in weight, were weighed and then immersed for 15 seconds in 10 ml normal saline solution containing 0%, 0.1%, 1%, 2%, and 5% of hyperoncotic medium molecular hydroxyethyl starch or 0%, 0.035%, 0.175%, 0.35%, and 0.7% degraded gelatin polypeptides. Clots were randomized to 10 seconds 20 kHz ultrasound or immersion without ultrasound. After treatment, the clots were reweighed, and the percent difference in weight was calculated. Non-gas filled microparticle-containing solutions such as hyperoncotic medium molecular hydroxyethyl starch and degraded gelatin polypeptides significantly augmented blood clot disruption by ultrasound. The effect is dependent on the colloidal solution concentration with maximal effect achieved with 1% hyperoncotic medium molecular hydroxyethyl starch and 0.35% degraded gelatin polypeptides.

Blood Coagulation↗

Incidence and clinical importance of perioperative histamine release: randomised study of volume loading and antihistamines after induction of anaesthesia. Trial Group Mainz/Marburg.

Although histamine release is recognised as a common event during anaesthesia and surgery, few clinicians judge the resultant cardiorespiratory disturbances serious enough to warrant prophylaxis with antihistamines. We have assessed the incidence and importance of histamine release in a randomised 2 x 2 factorial study. 240 patients representing a routine throughput of major general surgery were studied during a standardised induction of anaesthesia and preoperative loading of the circulation with either Ringer solution or Haemaccel-35, with or without antihistamine prophylaxis with dimetindene (H1) plus cimetidine (H2). Cardiorespiratory disturbances were graded as detectable, clinically relevant, or life-threatening from observers' records of the anaesthesia and the actions taken by the anaesthetists. Disturbances that were accompanied by significant rises in plasma histamine were further designated histamine-related, and those that were not were designated histamine-unrelated. Anaesthetists, observers, and designators were blinded to whether or not the patients had received antihistamines and to which solution was used for circulatory volume loading. Clinically relevant or life-threatening histamine-related disturbances occurred in 8% of the patients who after induction of anaesthesia received Ringer without antihistamines, in 26% of those who received Haemaccel without antihistamines, and in 2% or less of those who received antihistamines (p < or = 0.0001). There were 4 life-threatening histamine-related disturbances, all in patients who received Haemaccel without antihistamines (p < 0.01). Histamine-unrelated disturbances occurred in 16% overall, with no obvious effect of Haemaccel or antihistamines. The histamine-related disturbances under anaesthesia were remarkable for their severity (even with small rises in histamine concentrations), for the prevalence of bradycardia, and for the absence of skin signs. Their likelihood and severity were increased in patients with tumours. The results of the trial make a case for routine prophylaxis with antihistamines as part of anaesthetic management.

Adolescent↗

Acute hemodynamic changes following hemorrhage and volume restitution, using a low viscosity plasma expander, in anesthetized portal hypertensive rats.

BACKGROUND/AIM: The aim of this study was to examine, in a portal hypertensive rat model, the hemodynamic changes following hemorrhage and volume restitution with blood and Haemaccel (a low viscosity, volume expander). METHODS: Portal hypertension was induced by portal vein constriction. Under ketamine anesthesia, blood was withdrawn at a constant rate of 0.3 ml/min, for 15 min followed by 15 min of stabilization. The shed blood or Haemaccel was infused at the same rate and volume used for withdrawal. Hemodynamic measurements were performed using radioactive microspheres. Blood viscosity was measured with an Ostwald viscometer. Vascular hindrance was calculated as the resistance/viscosity ratio. RESULTS: Twelve rats were studied in each group. During blood withdrawal, significant reductions in arterial pressure and portal pressure were observed. Volume replacement with blood was accompanied by increased mean arterial pressure and portal pressure to baseline. Arterial pressure following volume replacement with Haemaccel was lower and portal pressure was higher than baseline (128+/-16 and 17.1+/-3.9 vs 146+/-13 and 15.9+/-3.0 mmHg, respectively; p<0.05). Volume replacement with Haemaccel, compared to blood, was followed by increased cardiac output and portal venous inflow (39.3+/-11.6 and 4.4+/-1.5 vs 28.9+/-3 and 2.9+/-0.8 ml x min(-1) x 100 g bw(-1), respectively; p<0.05), decreased hematocrit and viscosity (29.3+/-3.8% and 2.8+/-1.3 vs 35.7+/-3.4% and 4.0+/-1.3, respectively; p<0.01) and decreased peripheral and splanchnic arteriolar resistance (3.6+/-1.4 and 29.2+/-14.0 vs 5.0+/-1.4 and 43.9+/-12.7 mmHg x ml(-1) x min x 100 g bw, respectively; p<0.05). There were no significant changes in vascular hindrance in any vascular beds between the two groups. CONCLUSION: In this model, volume replacement with Haemaccel induced an increase in cardiac output and portal venous inflow, thus preventing the reduction in portal pressure which might be expected when viscosity is reduced.

Animals↗

Influence of fluid resuscitation on renal function in bacteremic and endotoxemic rats.

PURPOSE: Fluid resuscitation, which is the most important primary therapy in sepsis, is not always able to prevent acute renal failure. In this study, we investigated in two different rat models of distributive shock whether fluid resuscitation would increase renal plasma flow (RPF) and subsequently glomerular filtration rate (GFR). MATERIALS AND METHODS: In pentobarbital anesthetized wistar rats Haemaccel (Behring Pharma, Hoechst, the Netherlands) infusion (1.2 mL/100 g/h for 3 hours) was started immediately during either bacteremia (bolus of living Escherichia coli bacteria, 10(9) or endotoxemia (1 hour infusion of E. coli endotoxin, 8 mg/kg), as well as in time-matched healthy controls. RESULTS: After 3 hours, this treatment had increased RPF (clearance of 131I-hippurate) above normal in control (+67%) and bacteremic rats (+75%), whereas in endotoxemic animals, the significantly decreased RPF was normalized. On the other hand, in bacteremic animals, the lowered GFR (clearance of creatinine; x44%) was normalized, whereas in endotoxemic animals GFR remained depressed (x30%). The lack of improvement in GFR during endotoxemia was also indicated by a profound fall in urine flow, which by contrast steadily increased in control and bacteremic rats owing to volume loading. In both shocked groups, the decreased renal oxygen delivery was normalized, but the higher renal oxygen consumption than expected on the basis of the work needed for sodium reabsorption was not influenced by Haemaccel treatment, despite the fact that it caused this work load to rise in bacteremic but not in endotoxemic rats. In both shock models, renal cortical adenosine triphosphate content did not differ from healthy controls and was not influenced by volume loading. CONCLUSIONS: In conclusion, our study suggests that a decrease in GFR caused by live bacteria in the circulation may benefit from fluid resuscitation, while during endotoxemia this therapy could not prevent acute renal failure.

Animals↗

Blood viscosity, hemodynamics and vascular hindrance in a rat model of acute controlled bleeding and volume restitution with blood or Haemaccel.

BACKGROUND: Hemorrhage and volume restitution with commercially available solutions is followed by reduced blood viscosity. Consequent hemodynamic changes may arise not only from the reduced viscosity itself but also from changes in vascular geometry induced by autoregulation processes. Vascular hindrance reflects the contribution of vascular geometry to flow. Our aim was to explore the possible effects of blood volume restitution with Haemaccel or blood, on regional blood flow and vascular geometry. METHODS: Under ketamine anesthesia, blood was withdrawn at a rate of 0.3 ml/min for 15 min followed by 15 min of stabilization. The shed blood or Haemaccel was infused at the same rate and volume as used for withdrawal. Hemodynamic measurements were performed using radioactive microspheres. Blood viscosity was measured with an Ostwald viscometer. Vascular hindrance was calculated as the resistance/viscosity ratio. RESULTS: Volume replacement with Haemaccel (n=10), compared to blood (n=10), was followed by increased cardiac output and portal venous inflow (37.1 +/- 9.0 and 3.1 +/- 0.5 vs 25.9 +/- 6.8 and 2.2 +/- 0.9 ml x min(-1) x 100 g bw(-1), respectively; P<0.05), decreased viscosity (2.8 +/- 1.3 vs 3.7 +/- 1.3, respectively; P<0.01) and decreased peripheral and splanchnic arteriolar resistance (3.8 +/- 1.1 and 40.9 +/- 7.6 vs 5.2 +/- 1.7 and 61.1 +/- 29.5 mmHg x ml(-1) x min x 100 g bw, respectively; P<0.05). No significant differences between the groups were observed in vascular hindrance and cardiac output distribution. CONCLUSION: Volume replacement with Haemaccel, compared to blood, induced increase in systemic and splanchnic blood flows, reflecting mainly changes in viscosity and not in blood vessel geometry. These results suggest no significant difference in overall activation of autoregulation process between volume restitution with blood or Haemaccel.

Animals↗

Dissociation of glomerular filtration and renal blood flow in HgCl2-induced acute renal failure.

This study evaluates the role of early renal vasoconstriction in the pathogenesis of mercuric chloride (HgCl2)-induced acute renal failure (ARF) in the dog. Within 3 hr after mercury, glomerular filtration rate (GFR), from 45 +/- 4 25 +/- 2 ml/min, and renal blood flow (RBF), from 268 +/- 22 to 161 +/- 19 ml/min, decreased simultaneously. A rise in diuresis and urinary solute excretion occurred. Morphological and functional studies excluded a major role for tubular leakage or obstruction. An attempt was made to prevent the early renal vasoconstriction, by the administration of Haemaccel, a plasma volume expander, alone or in combination with phentolamine. In both settings the fall in RBF after mercury was prevented. Haemaccel volume expansion alone provoked a significant rise in GFR before HgCl2, but the GFR fell by 29% 3 hr after HgCl2. The Haemaccel/phentolamine combination had no influence on pre-mercury GFR values. In this group, a decrease of GFR by 44% was noted 3 hr after mercury. In conclusion, changes in GFR and renal hemodynamics can be dissociated in the early phase of nephrotoxic ARF. The fall in GFR can be attributed either to a decrease in glomerular ultrafiltration capacity and/or changes in glomerular afferent and efferent resistances, leading to a decrease in glomerular hydrostatic pressure.

Acute Kidney Injury↗

The effect of a synthetic polypeptide on the renal handling of protein in man.

Haemaccel is a synthetic polymer of partially degraded gelatin and a widely used plasma volume expander. The effect of a 17.5 g infusion of Haemaccel on protein excretion was investigated in four normal subjects. The urinary excretion of two low molecular weight proteins, retinol-binding protein and beta 2-microglobulin, increased 1000- and 500-fold respectively above the values found after administration of saline as a control. The urinary excretion of albumin did not change significantly (P greater than 0.5). In the hour after Haemaccel administration the excretion of the two low molecular weight proteins approached at least 50% of a predicted filtered load. This effect of Haemaccel may be due to inhibition of proximal tubular uptake or transport of the two proteins. Absence of any effect on albumin excretion suggests alternative mechanisms for its tubular reabsorption. Haemaccel may be a valuable new agent for the study of renal tubular protein metabolism.

Acetylglucosaminidase↗

Air emboli with Haemaccel(R)

We report two cases of venous air embolism which occurred in association with infusion of Haemaccel(R) using a pressure bag. As a result of these incidents, we performed a study that showed that up to 45 ml of air can be infused into a patient from a pressurised Haemaccel(R) plastic bottle using a standard administration set. We also demonstrated that the volume of air infused was influenced by the type and size of the pressure bag and the warming of the Haemaccel(R) plastic container.

Aged↗