Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Particle Accelerators”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Novel method for multiturn extraction: trapping charged particles in islands of phase space.

A novel method for multiturn extraction from a circular particle accelerator is presented, based on trapping particles into islands of phase space generated by nonlinear resonances. By appropriate use of sextupoles and octupoles, stable islands can be created at small amplitude in phase space. By varying the linear tune, particles can be trapped inside these islands and then transported towards higher amplitudes for extraction. Results of numerical simulations are discussed.

Journal Article↗

Induction and rejoining of DNA double-strand breaks in CHO cells after heavy ion irradiation.

DNA double-strand breaks (DSBs) are the crucial events ultimately leading to cell inactivation. Aimed at understanding the biological action of the charged particle component of cosmic radiation, the induction of DSBs and their repairability was evaluated in Chinese hamster ovary (CHO-K1) cells after exposure to accelerated particles. Irradiations were performed with various ion species including O, Ni and Ca, covering a LET range from 20 to 2000 keV/micrometer. DSBs were determined for plateau-phase cells using the electrophoretic elution of radiation-induced DNA fragments in a static electric field combined with fluorescence scanning of ethidium bromide stained gels. Assuming a DSB yield of 22 DSB per Gy per cell, as derived from X-irradiation, cross-sections for DSB production were calculated from the corresponding fluence-effect curves at a fraction of 0.7 of DNA retained. The same ordinate was used as a reference for the calculation of relative biological efficiency (RBE) for DSB induction. At low LETs (< or = 20 keV/micrometer) RBE values slightly above unity were obtained, but a decrease of RBE was observed with increasing LET. In the region of 100-200 keV/micrometer the RBE for initial DSB induction was clearly below unity. Rejoining of DSBs was assessed by measuring the fraction of DNA retained following post-irradiation incubation of cells under culture conditions. After exposure to Ca ions, DSB rejoining was considerably impaired compared to X-rays.

Animals↗

Radiation protection at low energy proton accelerators.

A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps not unique treatment but those which benefit from a different approach. Among the problems discussed are the generation of prompt radiation and its transmission through shielding, the estimation of induced radioactivity, and the assessments of both the off-site prompt radiation hazard and the effect of releases of radioactive effluents to the environment.

Dose-Response Relationship, Radiation↗

Lévy-Student distributions for halos in accelerator beams.

We describe the transverse beam distribution in particle accelerators within the controlled, stochastic dynamical scheme of stochastic mechanics (SM) which produces time reversal invariant diffusion processes. This leads to a linearized theory summarized in a Schrödinger-like (SL) equation. The space charge effects have been introduced in recent papers by coupling this S-L equation with the Maxwell equations. We analyze the space-charge effects to understand how the dynamics produces the actual beam distributions, and in particular we show how the stationary, self-consistent solutions are related to the (external and space-charge) potentials both when we suppose that the external field is harmonic (constant focusing), and when we a priori prescribe the shape of the stationary solution. We then proceed to discuss a few other ideas by introducing generalized Student distributions, namely, non-Gaussian, Lévy infinitely divisible (but not stable) distributions. We will discuss this idea from two different standpoints: (a) first by supposing that the stationary distribution of our (Wiener powered) SM model is a Student distribution; (b) by supposing that our model is based on a (non-Gaussian) Lévy process whose increments are Student distributed. We show that in the case (a) the longer tails of the power decay of the Student laws and in the case (b) the discontinuities of the Lévy-Student process can well account for the rare escape of particles from the beam core, and hence for the formation of a halo in intense beams.

Journal Article↗

Inactivation of individual Bacillus subtilis spores in dependence on their distance to single accelerated heavy ions.

In order to understand radiation mechanisms of heavy ions in detail, it is necessary to study effects of single ions on individual biological test objects. Spores of Bacillus subtilis have been used as a suitable small biological test system to measure the inactivation in dependence on the radial distance to the tracks of charged particles. Accelerator experiments have been performed using a modified Biostack technique--biological objects sandwiched between nuclear track detectors. Results of these experiments using ions differing in their energy and atomic number will be discussed under following aspects: (i) methodological differences between the experiments and their possible influences on the results, (ii) common features which are independent on the particle type and energy, (iii) theoretical expectations and problems to find solid theoretical concepts which explain the results.

Argon↗

Surfatron and stochastic acceleration of electrons at supernova remnant shocks.

The surfatron offers the possibility of particle acceleration to arbitrarily high energies, given a sufficiently large system. Surfatron acceleration of electrons by waves excited by ions reflected from supernova remnant (SNR) shocks is investigated using particle simulations. It is shown that surfatron and stochastic acceleration could provide a seed population for the acceleration of cosmic ray electrons at SNR shocks.

Journal Article↗

Radiation protection and environmental management at the relativistic heavy ion collider.

The Relativistic Heavy Ion Collider (RHIC) is a high energy hadron accelerator built to study basic nuclear physics. It consists of two counter-rotating beams of fully stripped gold ions that are accelerated in two rings to an energy of 100 GeV/nucleon or protons at 250 GeV/c. The beams can be stored for a period of five to ten hours and brought into collision for experiments during that time. The first major physics objective is to recreate a state of matter, the quark-gluon plasma, that has been predicted to have existed at a short time after the creation of the universe. Because there are only a few other high energy particle accelerators like RHIC in the world, the rules promulgated in the US Code of Federal Regulations under the Atomic Energy Act, State regulations, or international guidance documents do not cover prompt radiation from accelerators to govern directly the design and operation of a superconducting collider. Special design criteria for prompt radiation were developed to provide guidance tor the design of radiation shielding. Environmental Management at RHIC is accomplished through the ISO 14001 Environmental Management System. The applicability, benefits, and implementation of ISO 14001 within the framework of a large research accelerator complex are discussed in the paper.

Environment↗

High-power CW LINAC for food irradiation.

The continuing high profile food poisoning incidents are beginning to attract food processors using electron and gamma-ray sterilization technologies. The present method of choice uses radioactive isotopes but high-power electron particle accelerators are proving an increasingly attractive alternative. We are developing a family of compact industrial continuous wave linear accelerators which produce electrons with energies from 600 keV in increments of approximately 600 keV and with beam power of 30 kW increasing in increments of 30 kW. Here, we describe the performance of our 1st section that accelerates 15 keV gun electrons to relativistic energies and then we sketch the design of the less demanding subsequent sections that we are now constructing.

Electrons↗

Generation of periodic accelerating structures in plasma by colliding laser pulses.

A mechanism for generating large (>1 GeV/m) accelerating wakes in a plasma is proposed. Two slightly detuned counterpropagating laser beams, an ultrashort timing pulse and a long pump, exchange photons and deposit the recoil momentum in plasma electrons. This produces a localized region of electron current, which acts as a virtual electron beam, inducing intense plasma wakes with phase velocity equal to the group velocity of the short pulse. Modulating the pumping beam generates periodic accelerating structures in the plasma ("plasma linac") which can be used for particle acceleration unlimited by the dephasing between the particles and the wake. An important difference between this type of plasma accelerator and the conventional wakefield accelerators is that this type can be achieved with laser intensities I<<10(18) W/cm(2).

Journal Article↗

Bubble detector characterization for space radiation.

In light of the importance of the neutron contribution to the dose equivalent received by space workers in the near-Earth radiation environment, there is an increasing need for a personal dosimeter that is passive in nature and able to respond to this neutron field in real time. Recent Canadian technology has led to the development of a bubble detector, which is sensitive to neutrons, but insensitive to low linear energy transfer (LET) radiation. By changing the composition of the bubble detector fluid (or "superheat"), the detectors can be fabricated to respond to different types of radiation. This paper describes a preliminary ground-based research effort to better characterize the bubble detectors of different compositions at various charged-particle accelerator facilities, which are capable of simulating the space radiation field.

Calibration↗

Cellular effects of heavy charged particles.

The human cell is rendered reproductively inactive by the passage of a single heavy ion through its nucleus when the heavy ion deposits energy at a rate greater than about 3500 MeV cm-1. This is demonstrated by the correlation of inactivation probability with nuclear area when cells having nuclei of different sizes are compared. This single-hit inactivation is irreversible and unmodifiable. The ion path length over which cells will be inactivated in this way is calculable from stopping power theory. Laboratory experiments in which three-dimensional human cell cultures were irradiated with high-energy nitrogen ions (3.9 GeV) at the Princeton Particle Accelerator confirm that cells are inactivated with maximum probability over the last 0.5 cm of the ion trajectory. This means that groups of adjacent cells in the ion path will be inactivated by a single ion with high probability. Organized systems of multiplying cells would be expected to amplify this spatially correlated effect of heavy ion irradiation. Abnormalities induced in Zea seedlings by heavy ion irradiation of seeds are consistent with the inactivation of embryonic cells in groups.

Animals↗

The production of no-carrier-added radiopharmaceuticals with special reference to radionuclide impurities.

Charged-particle accelerators are being utilized extensively for the production of several neutron-deficient radionuclides for use in the synthesis of radiopharmaceuticals for diagnostic nuclear-medicine applications. The diversity of techniques being employed results in radionuclide preparations having significantly different radionuclidic composition. The choice of nuclear reaction, the knowledge of excitation functions, the proper timing and use of radiochemical methods, are all factors which will to some extent determine the quality of a radionuclide preparation. The different factors governing the production and quality of medical radionuclides will be discussed, with particular attention to the formation of radionuclidic impurities, and their effects in nuclear medicine practice.

Iodine Radioisotopes↗

Cyclotrons and positron emission tomography radiopharmaceuticals for clinical imaging.

Positron emission tomography (PET) requires positron-emitting radionuclides that emit 511-keV photons detectable by PET imagers. Positron-emitting radionuclides are commonly produced in charged particle accelerators, eg, linear accelerators or cyclotrons. The most widely available radiopharmaceuticals for PET imaging are carbon-11-, nitrogen-13-, and oxygen-15-labeled compounds, many of which, either in their normal state or incorporated in other compounds, serve as physiological tracers. Other useful PET radiopharmaceuticals include fluorine-18-, bromine-75-, gallium-68 (68Ga)-, rubidium-82 (82Rb)-, and copper-62 (62Cu)-labeled compounds. Many positron emitters have short half-lives and thus require on-site cyclotrons for application, and others (68Ga, 82Rb, and 62Cu) are available from radionuclides generators using relatively long-lived parent radionuclides. This review is divided into two sections: cyclotrons and PET radiopharmaceuticals for clinical imaging. In the cyclotron section, the principle of operation of the cyclotron, types of cyclotrons, medical cyclotrons, and production of radionuclides are discussed. In the section on PET radiopharmaceuticals, the synthesis and clinical use of PET radiopharmaceuticals are described.

Brain↗

Design and simulation of a neutron facility.

State and other regulatory entities require that for any facility housing a particle accelerator the surrounding areas must be restricted to public access unless the dose equivalent rate is less than 0.02 mSv h at 5 cm from any accessible wall surrounding the facility under conditions of maximum radiation output. A Monte Carlo radiation transport simulation code, MCNP5, was used to design a proposed facility to shield two D-T neutron generators and one D-D neutron generator. A number of different designs were simulated, but due to cost and space issues a small concrete cave proved to be the best solution for the shielding problem. With this design, all of the neutron generators could be used and all of the rooms surrounding the neutron facility could be considered unrestricted to public access. To prevent unauthorized access into the restricted area of the neutron facility, light curtains, warning lights, door interlocks, and rope barriers will be built into the facility.

Computer Simulation↗

Low energy proton irradiation effects on alveolar macrophages from young and aged rats.

A prospective study was undertaken to assess the radiotoxicity of accelerated particles in pulmonary alveolar macrophages (AM). We evaluated the effects of a single dose (10-75 Gy) of an external low-energy (20 MeV) proton beam on cultured AM oxidative metabolism and phagocytic function. Macrophages are the first line of defense against invading pathogens and are known to generate superoxide anion (O2), nitric oxide (NO), and mediators of antimicrobial and antitumoral defense mechanisms. We obtained AM by bronchoalveolar lavage from young (1-2 month old) and aged (9-12 month old) male Wistar rats. Cell viability, phagocytosis, O2 and NO production in control and proton-irradiated cultured AM were evaluated The effect of proton irradiation on cell viability was dose-dependent The higher doses induced a dramatic decrease in viability in the aged population. Phagocytosis increased 1.3-1.4 fold inboth populations irrespective of the dose delivered. Generation of O2 was always higher in the aged population for all the doses assayed and showed no significant variation from the control values. In the young population a clear increase was observed with doses of 25 and 50 Gy. NO production in AM from young animals rose in a dose-dependent manner. Conversely, proton irradiation did not affect NO production in macrophages from aged animals. The results of this study demonstrate that AM isolated from young and aged rats are functionally different and show a distinct behavior when exposed to proton irradiation. These findings suggest that age may condition response and must be taken into account when accelerated particle-radiotherapy protocols are considered as a valid therapeutic option for the treatment of cancer. To the best of our knowledge, this is the first report comparing sham-irradiated and proton-irradiated young and aged AM.

Aging↗

An improved Green's function for ion beam transport.

Ion beam transport theory allows testing of material transmission properties in the laboratory environment generated by particle accelerators. This is a necessary step in materials development and evaluation for space use. The approximations used in solving the Boltzmann transport equation for the space setting are often not sufficient for laboratory work and those issues are the main emphasis of the present work. In consequence, an analytic solution of the linear Boltzmann equation is pursued in the form of a Green's function allowing flexibility in application to a broad range of boundary value problems. It has been established that simple solutions can be found for high charge and energy (HZE) ions by ignoring nuclear energy downshifts and dispersion. Such solutions were found to be supported by experimental evidence with HZE ion beams when multiple scattering was added. Lacking from the prior solutions were range and energy straggling and energy downshift with dispersion associated with nuclear events. Recently, we have found global solutions including these effects providing a broader class of HZE ion solutions.

Aluminum↗

A feasibility study of a single event spectrometer based on semiconductor devices.

The electronics employed around particle accelerators can be disturbed or damaged because of single event effects (SEE). The most likely effect is the single event upset (SEU) which may affect all memory devices. In the case of high energy accelerators, SEUs are mostly produced by secondary charged particles generated by neutron interactions. The measurement of the energy and the lineal energy distribution of these neutron-induced charged particles was proposed. As a first approach, a commercial p-i-n photodiode was employed. This device was irradiated with thermal and monoenergetic fast neutrons. Some effects limiting the use of such a detector as a SEE spectrometer were observed, giving guidelines for the design of an application specific integrated circuit (ASIC). The possibility of creating a solid state microdosemeter by coupling the ASIC with a tissue-equivalent radiator is discussed. Moreover, the p-i-n photodiode covered with a hydrogenated plastic radiator may be employed as a proton-recoil spectrometer.

Dose-Response Relationship, Radiation↗

Lane formation in colloidal mixtures driven by an external field.

The influence of an external field on a binary colloidal mixture performing Brownian dynamics in a solvent is investigated by nonequilibrium computer simulations and simple theory. In our model, one half of the particles are pushed into the field direction while the other half of them are pulled into the opposite direction. For increasing field strength, we show that the system undergoes a nonequilibrium phase transition from a disordered state to a state characterized by lane formation parallel to the field direction. The lanes are formed by the same kind of particles moving collectively with the field. Lane formation accelerates particle transport parallel to the field direction but suppresses massively transport perpendicular to the field. We further show that lane formation also occurs in a time-dependent oscillatory field. If the frequency of the external field exceeds a critical value, however, the system exhibits a transition back to the disordered state. Our results can be experimentally verified in binary colloidal suspensions exposed to external fields under nonequilibrium conditions.

Journal Article↗