Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Multiplex”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Clinical demographics of multiplex families with multiple sclerosis. Multiple Sclerosis Genetics Group.

The demographic and clinical characteristics of 89 multiplex families whose affected members meet proposed diagnostic criteria for multiple sclerosis (MS) genetic research are described and compared with 425 sporadic cases of MS and other published collections of MS multiplex families. The proportion of affected multiplex family members who experienced gradual progression of disability from onset (primary progressive MS) is lower than reported by other investigators. Different phenotypes of MS may reflect genetic heterogeneity that may partially explain inconsistencies in the results of genetic linkage studies. Clinical details of affected multiplex family members must be described so that comparisons of genetic results across studies can be properly interpreted.

Adolescent↗

Multiplexed DNA sizing by capillary electrophoresis using entangled polymer solutions and diode array detection.

We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.

Bacteriophage phi X 174↗

Fluorescent microsphere-based readout technology for multiplexed human single nucleotide polymorphism analysis and bacterial identification.

Large-scale human genotyping requires technologies with a minimal number of steps, high accuracy, and the ability to automate at a reasonable cost. In this regard, we have developed a rapid, cost-effective readout method for single nucleotide polymorphism (SNP) genotyping that combines an easily automatable single-tube allele-specific primer extension (ASPE) with an efficient high throughput flow cytometric analysis performed on a Luminex 100 flow cytometer. This robust technique employs an ASPE reaction using PCR-derived target DNA containing the SNP and a pair of synthetic complementary capture probes that differ at their 3' end-nucleotide defining the alleles. Each capture probe has been synthesized to contain a unique 25-nucleotide identifying sequence (ZipCode) at its 5' end. An array of fluorescent microspheres, covalently coupled with complementary ZipCode sequences (cZipCodes), was hybridized to biotin-labeled ASPE reaction products, sequestering them for flow cytometric analysis. ASPE offers both an advantage of streamlining the SNP analysis protocol and an ability to perform multiplex SNP analysis on any mixture of allelic variants. All steps of the assay are simple additions of the solutions, incubations, and washes. This technique was used to assay 15 multiplexed SNPs on human chromosome 12 from 96 patients. Comparison of the microsphere-based ASPE assay results to gel-based oligonucleotide ligation assay (OLA) results showed 99.2% agreement in genotype assignments. In addition, the microsphere-based multiplex SNPs assay system was adapted for the identification of bacterial samples by both ASPE and single base chain extension (SBCE) assays. A series of probes designed for different variable sites of bacterial 16S rDNA permitted multiplex analysis and generated species- or genus-specific patterns. Seventeen bacterial species representing a broad range of gram-negative and gram-positive bacteria were analyzed within 16 variable sites of 16S rDNA sequence. The results were consistent with the published sequences and confirmed by direct DNA sequencing.

Alleles↗

A four-channel time domain multiplexer: a cost-effective alternative to multiple receivers.

The concept of simultaneous image acquisition as originally conceived by Hyde has been implemented by Roemer et al. using a multiple receiver system. This article describes an alternative technique that uses time domain multiplexing (TDM) to acquire simultaneous images using a single receiver channel. This method requires few modifications to the existing receiver and has been shown to be equivalent to a true four channel receiver in most applications. The multiplexing technique was implemented and tested on a standard commercial scanner that has also been equipped with a four channel receiver. Signal-to-noise results demonstrate that four independent images can be multiplexed through a single receiver channel with no degradation in image quality. Additionally, spine images that were obtained from a normal volunteer with both a multiplexed single channel receiver and a true four channel receiver system are presented.

Cost-Benefit Analysis↗

Use of a five-channel multiplexed electrospray quadrupole time-of-flight hybrid mass spectrometer for metabolite identification.

Metabolism data provided with reduced cycle time has become of increasing importance for the early evaluation of DMPK properties of drugs in discovery. In this regard, quadrupole time-of-flight hybrid mass spectrometers (Q-TOF) can provide very reliable metabolite identification via accurate mass measurement of ions and the consequent access to the elemental composition of the metabolite. However, due to their cost, they are often used for drug metabolism studies on later stage drug candidates or to address challenging metabolism questions. A new prototype, consisting of a five-channel multiplexed electrospray ionization (ESI) source on a Q-TOF with one channel used for lock-mass compound infusion, was evaluated for metabolite identification. The goal was to increase the sample throughput of a single ESI-MS system by a factor of 4, while maintaining efficient metabolite separation in high-performance liquid chromatography (HPLC) as well as adequate sensitivity and mass accuracy, and ultimately improve the speed and quality of metabolism studies supporting drug discovery. The analytical performance of the system was assessed by evaluating the sensitivity and mass accuracy (using real in vitro and in vivo samples), inter-channel differences in retention times, MS/UV response, and cross-talk among channels. The sensitivity using the multiplexed ESI source was on average 2-fold lower than with single ESI, correlating well with previous literature data. The mass accuracy was comparable to that obtained using single ESI in both MS and MS/MS modes, making the metabolite identification process using the multiplexed ESI source as reliable as with single ESI. Compound-dependent differences in ionization efficiencies were observed among channels, and were minimized by analyzing related samples on the same channel. Finally, the level of cross-talk among channels was acceptable (around 0.3%) and comparable to levels previously published for quantitative applications using multiplexed ESI. The paper also focuses on the advantages and disadvantages of this new approach compared to other approaches in the literature in the field of metabolite identification.

Animals↗

Enzyme-linked fluorescent detection for automated multiplex DNA sequencing.

Initiatives to sequence DNA on a large scale have created a need for increased throughput and decreased costs. One scheme for increasing throughput, multiplex sequencing, involves the processing of a mixture of sequencing templates followed by sequential hybridization to reveal the individual sequence ladders on a membrane. Because multiplex sequencing has not been fully automated, and has not seemed automatable, few sequencing efforts have attempted to exploit it. We describe here a scheme for the automation of multiplex sequencing. Probe hybridized to target DNA is detected via spatially localized enzyme-linked fluorescence. Light output is high enough that imaging is possible with simple instrumentation. Direct imaging within an automated hybridization apparatus is made feasible so that the entire process will be automatic once a multiplex membrane is produced. The technique has the potential to increase severalfold the throughput of automated sequencing instruments required for sequencing the human genome.

Base Sequence↗

Linkage analysis with multiplexed short tandem repeat polymorphisms using infrared fluorescence and M13 tailed primers.

The use of short tandem repeat polymorphisms (STRPs) as marker loci for linkage analysis is becoming increasingly important due to their large numbers in the human genome and their high degree of polymorphism. Fluorescence-based detection of the STRP pattern with an automated DNA sequencer has improved the efficiency of this technique by eliminating the need for radioactivity and producing a digitized autoradiogram-like image that can be used for computer analysis. In an effort to simplify the procedure and to reduce the cost of fluorescence STRP analysis, we have developed a technique known as multiplexing STRPs with tailed primers (MSTP) using primers that have a 19-bp extension, identical to the sequence of an M13 sequencing primer, on the 5' end of the forward primer in conjunction with multiplexing several primer pairs in a single polymerase chain reaction (PCR) amplification. The banding pattern is detected with the addition of the M13 primer-dye conjugate as the sole primer conjugated to the fluorescent dye, eliminating the need for direct conjugation of the infrared fluorescent dye to the STRP primers. The use of MSTP for linkage analysis greatly reduces the number of PCR reactions. Up to five primer pairs can be multiplexed together in the same reaction. At present, a set of 148 STRP markers spaced at an average genetic distance of 28 cM throughout the autosomal genome can be analyzed in 37 sets of multiplexed amplification reactions. We have automated the analysis of these patterns for linkage using software that both detects the STRP banding pattern and determines their sizes. This information can then be exported in a user-defined format from a database manager for linkage analysis.

Chromosome Mapping↗

Optimized multiplex PCR: efficiently closing a whole-genome shotgun sequencing project.

A new method has been developed for rapidly closing a large number of gaps in a whole-genome shotgun sequencing project. The method employs multiplex PCR and a novel pooling strategy to minimize the number of laboratory procedures required to sequence the unknown DNA that falls in between contiguous sequences. Multiplex sequencing, a novel procedure in which multiple PCR primers are used in a single sequencing reaction, is used to interpret the multiplex PCR results. Two protocols are presented, one that minimizes pipetting and another that minimizes the number of reactions. The pipette optimized multiplex PCR method has been employed in the final phases of closing the Streptococcus pneumoniae genome sequence, with excellent results.

Algorithms↗

Direct detection of vanA and vanB genes in clinical specimens for rapid identification of vancomycin resistant enterococci (VRE) using multiplex PCR.

Surveillance for vancomycin resistant enterococci (VRE) by culture can be labour intensive and time consuming. We have developed a multiplex polymerase chain reaction (MPCR) which can be performed directly on the clinical specimen. The assay allows sensitive detection of enterococci with vanA - and vanB -mediated resistance to vancomycin. DNA was purified from stool and rectal specimens using the XTRAX(TM)DNA Extraction Kit (Gull Labs). Multiplex PCR amplified vanA and vanB targets were detected using a microtiter plate EIA. Two-hundred specimens were tested by routine culture and MPCR. Culture identified 44 VRE isolates and MPCR detected 38 of the 44 culture positives. Multiplex PCR detected three additional positive VRE specimens missed by culture for a sensitivity and specificity of 86.4 and 98.1%, respectively. When the presence of PCR inhibitors was addressed in the six culture positive/MPCR negative specimens, four additional VRE positive specimens were detected. Performing MPCR on the original specimens and on a 1:10 dilution of all specimens to minimize the effect of inhibitors gave a sensitivity and specificity of 95.5 and 98.1%, respectively. Multiplex PCR with confirmation by microtiter plate hybridization could be completed in 8 h compared with 24-48 h required for culture.

Bacterial Proteins↗

Comparison of multiplex PCR, PCR-ELISA and fluorogenic 5' nuclease PCR assays for detection of plasmid-bearing virulent Yersinia enterocolitica in swine feces.

Swine are implicated as the principal animal reservoir for plasmid-bearing Yersinia enterocolitica (YEP(+)) strains that are pathogenic to humans. To evaluate the utility of the PCR for detection of YEP(+) strains in naturally-contaminated pig feces, samples were first enriched in Irgasan ticarcillin potassium chlorate broth for 48 h at 25 degrees C and then tested by multiplex PCR, PCR-ELISA, and fluorogenic 5' nuclease PCR assays. Three different primer sets for amplification of the ail gene sequences were used in these three assays. Three out of 50 (6%) samples were positive for YEP(+) strains using the multiplex PCR targeting the chromosomal ail (170 bp) and plasmid virF (591 bp) genes. Two of the 3 samples positive by the multiplex PCR were also positive by the PCR-ELISA method using primers targeting the ail gene (425 bp). In contrast, the fluorogenic 5' nuclease PCR assay failed to detect an ail gene sequence (118 bp) in any of the 50 samples. These results indicate that the multiplex PCR was the most reliable and sensitive assay for detecting YEP(+) strains in feces among the three assays evaluated.

Animals↗

Sensitivity of multiplex real-time PCR reactions, using the LightCycler and the ABI PRISM 7700 Sequence Detection System, is dependent on the concentration of the DNA polymerase.

The introduction of multiplex PCR techniques to clinical laboratories has provided a means to streamline assays and to produce multiple results with minimal effort. While this methodology is very beneficial, care must be taken to ensure that reactions are properly optimized to allow for maximum sensitivity. This study was conducted to determine whether the sensitivity of multiplex-real-time PCR assays could be improved by increasing the concentration of DNA polymerase within a reaction. Multiplex reactions were designed to simultaneously detect the human HLA-DQ gene and a sequence from the UL83 region of the CMV genome. Two real-time PCR systems, one utilizing AmpliTaq Gold DNA polymerase and the ABI 7700 Sequence Detection System, and one utilizing FastStart Taq DNA polymerase and the Roche LightCycler were tested. The results indicated that increasing the AmpliTaq Gold concentration from 0.050 to 0.10 U/microl and the FastStart Taq concentration from 0.1875 to 0.375 U/microl increased detection sensitivity from 5,000 to 50 CMV copies per PCR reaction. In separate experiments, commercially prepared mastermixes were utilized for both real-time PCR platforms as per the manufacturer's suggestions or with the addition of supplemental DNA polymerase. In assays designed to detect 4 CMV genome copies per reaction, the addition of 2.5 U of AmpliTaq Gold to TaqMan Universal Mastermix increased the detection rate from 21 to 67%, and the addition of 5 U of FastStart Taq to FastStart DNA Master Hybridization Probes mastermix increased the detection rate from 17 to 56%. These results indicate that increasing the DNA polymerase concentration in multiplex real-time PCR reactions may be a simple way to optimize assay sensitivity.

Cytomegalovirus↗

Real-time multiplex PCR assays.

The ability to multiplex PCR by probe color and melting temperature (T(m)) greatly expands the power of real-time analysis. Simple hybridization probes with only a single fluorescent dye can be used for quantification and allele typing. Different probes are labeled with dyes that have unique emission spectra. Spectral data are collected with discrete optics or dispersed onto an array for detection. Spectral overlap between dyes is corrected by using pure dye spectra to deconvolute the experimental data by matrix algebra. Since fluorescence is temperature dependent and depends on the dye, spectral overlap and color compensation constants are also temperature dependent. Single-labeled probes are easier to synthesize and purify than more complex probes with two or more dyes. In addition, the fluorescence of single-labeled probes is reversible and depends only on hybridization of the probe to the target, allowing study of the melting characteristics of the probe. Although melting curves can be obtained during PCR, data are usually acquired at near-equilibrium rates of 0.05-0.2 degrees C/s after PCR is complete. Using rapid-cycle PCR, amplification requires about 20 min followed by a 10-min melting curve, greatly reducing result turnaround time. In addition to dye color, melting temperature can be used for a second dimension of multiplexing. Multiplexing by color and T(m) creates a "virtual" two-dimensional multiplexing array without the need for an immobilized matrix of probes. Instead of physical separation along the X and Y axes, amplification products are identified by different fluorescence spectra and melting characteristics.

Animals↗

The development of multiplex simple sequence repeat (SSR) markers to complement distinctness, uniformity and stability testing of rape (Brassica napus L.) varieties.

To assess the potential of multiplex SSR markers for testing distinctness, uniformity and stability of rape (Brassica napus L.) varieties, we developed three multiplex SSR sets composed of five markers each. These were used to measure the extent of diversity within and between a set of ten varieties using a fluorescence-based semi-automated detection technology. Also, we evaluated the significance of any correlation between SSRs, pedigree and five of the morphological characters currently used for statutory distinctness, uniformity and stability testing of rape varieties. An assignment test was allowed to identify 99% of the plants examined, with the correct variety based on the analysis of 48 individual plants for each variety. Principal coordinate analysis confirmed that a high degree of separation between varieties could be achieved. Varieties were separated in three groups corresponding to winter, spring and forage types. These results suggested that it should be possible to select a set of markers for obtaining a suitable separation. Diversity within varieties varied considerably, according to the variety and the locus examined. No significant correlation was found between SSR and morphological data. However, genetic distances measured by SSRs were correlated to pedigree. These results suggested that SSRs could be used for pre-screening or grouping of existing and candidate varieties, allowing the number of varieties that need to be grown for comparison to be reduced. Multiplex SSR sets gave high-throughput reproducible results, thus reducing the costs of SSR assessment. Multiplex SSR sets are a promising way forward for complementing the current variety testing system in B. napus.

Brassica napus↗

Capillary electrophoresis as a tool for optimization of multiplex PCR reactions.

Copying multiple regions of a DNA molecule is routinely performed today using the polymerase chain reaction (PCR) in a process commonly referred to as multiplex PCR. The development of a multiplex PCR reaction involves designing primer sets and examining various combinations of those primer sets and different reaction components and/or thermal cycling conditions. The process of optimizing a multiplex PCR reaction in order to obtain a well-balanced set of amplicons can be time-consuming and labor-intensive. The rapid separation and quantitation capabilities of capillary electrophoresis make it an efficient technique to help in the multiplex PCR optimization process.

Alleles↗

Multiplex PCR--a rapid screening method for detection of gene rearrangements in childhood acute lymphoblastic leukemia.

Chromosomal rearrangements in childhood acute lymphoblastic leukemia (ALL) play an important role in the identification of clinical relevant subgroups. For rapid and easy detection of the clinically most important gene rearrangements, a nested multiplex reverse transcriptase polymerase chain reaction (multiplex PCR) was developed. This multiplex PCR enables the detection of M-BCR/ABL, m-BCR/ABL, TEL/ AML1, and MLL/AF4 fusion transcripts in one PCR reaction. However, the existence of splicing variants and different breakpoints on the DNA level hampers the discrimination of the rearrangements by their fragment size on an agarose gel. Therefore, one of the internal primers of each translocation (ABL-2, TEL-2, AF4-2) was labeled with a characteristic fluorescent dye, and an automatic fluorescence-based DNA fragment analysis was performed. The sensitivity of this multiplex PCR is in the same range as that of the corresponding single PCR reaction and allows a fast screening for the detection of therapy-relevant rearrangements, with a high turnover of samples.

Base Sequence↗

Development of a 13-locus PCR multiplex system for paternity testing.

In this study the development of a 13-locus multiplex-PCR system fitting the updated demands for paternity testing in Germany is described. For this purpose an existing multiplex PCR system that allows the simultaneous amplification of eight different STR loci together with the sex-specific locus amelogenin ( genRESMPX-2, Serac, Germany) was extended. Whereas some of the primers were taken from the underlying multiplex system, suitable primer sequences were chosen for the STR loci D19S433, TPOX, TH01, D16S539, D5S818, D2S1338 and FGA. Primers of loci resulting in potentially overlapping fragment sizes were labelled with the fluorescent dyes 6-FAM, JOE and NED. Reaction conditions, such as annealing temperature, concentrations of primers and polymerase or buffer conditions were optimised to obtain a robust amplification and reproducible genotype analysis for various sample sources. Full DNA profiles from single source samples were reliably typed from template DNA amounts of as low as 120 pg, suggesting a potential use of this system also in forensic casework analysis. With a mean exclusion chance (MEC) of 99.9989% and a power of discrimination (P(D)) of about 1x10(14) (Caucasians), the new multiplex PCR system provides a significant and sensitive system for forensic DNA analysis. On the basis of these studies, a commercial kit system is now provided by Serac (Bad Homburg, Germany, genRESMPX-3).

Allelic Imbalance↗

Multiplex polymerase chain reaction amplification and direct sequencing of homologous sequences: point mutation analysis of the ras genes.

ras proto-oncogenes are activated by point mutation in a wide variety of human and animal tumors, making ras gene analysis a major area of clinical and basic cancer research. Activating point mutations, in each of the three ras genes (Ha-, Ki-, or N-ras), usually occur in one of three specific codons (12, 13, or 61). Thus, an adequate assessment of activating ras gene mutations should include the analysis of at least nine codons. We have developed a rapid method for point mutation analysis of the ras genes, which involves simultaneous (multiplex) PCR amplification of all three homologous ras genes (in the regions surrounding codons 12-13 and codon 61) in a single reaction starting with only 1 microgram of genomic DNA. Although multiplex PCR has been previously used for unrelated sequences, we demonstrate here that multiplex PCR can also be used for highly homologous sequences. Importantly, after coamplification, each of the homologous ras genes can be individually and specifically sequenced even though the other two closely related genes are present in the same template mixture, by using high-stringency conditions permitted by Taq DNA polymerase. An automated multicycle DNA sequencing procedure is used to allow the double-stranded PCR products to be sequenced directly without the need to generate single-stranded templates, further simplifying the protocol. Our multiplex PCR amplification and direct DNA sequencing procedures should greatly facilitate more complete analyses of activating ras gene point mutations, particularly in studies involving many tumor samples.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Rapid method for identification of chemopreventive compounds using multiplex RT-PCR for cyclooxygenase mRNA expression.

Inhibition of the expression of the cyclooxygenase-2 (COX-2) enzyme has been associated with prevention or reversal of cancer development in several organs. Development of, or screening for, selective cyclooxygenase (COX) inhibitors is an approach for identifying chemopreventive agents. The aim of this project was to develop a rapid semi-quantitative multiplex RT-PCR for analysis of the expression of cyclooxygenase 1 and 2 genes relative to 18S, the housekeeping gene, in a 3-gene multiplex reaction. The optimal conditions for the 3-gene multiplex reaction were determined experimentally. Following RT-PCR, the amplified PCR products are analyzed by capillary electrophoresis-based LabChip and the Agilent 2100 bioanalyzer, which eliminates electrophoresis through ethidium bromide-agarose gels and normalization of band intensities using software programs such as Molecular Analyst. The multiplex RT-PCR assay developed here is a cost effective technique for routine application in laboratories that are screening natural or synthetic compounds for specific inhibitors of cyclooxygenase-2 as potential chemopreventive agents.

Automation↗