Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microscopy, Scanning Probe”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Chiral recognition in dimerization of adsorbed cysteine observed by scanning tunnelling microscopy.

Stereochemistry plays a central role in controlling molecular recognition and interaction: the chemical and biological properties of molecules depend not only on the nature of their constituent atoms but also on how these atoms are positioned in space. Chiral specificity is consequently fundamental in chemical biology and pharmacology and has accordingly been widely studied. Advances in scanning probe microscopies now make it possible to probe chiral phenomena at surfaces at the molecular level. These methods have been used to determine the chirality of adsorbed molecules, and to provide direct evidence for chiral discrimination in molecular interactions and the spontaneous resolution of adsorbates into extended enantiomerically pure overlayers. Here we report scanning tunnelling microscopy studies of cysteine adsorbed to a (110) gold surface, which show that molecular pairs formed from a racemic mixture of this naturally occurring amino acid are exclusively homochiral, and that their binding to the gold surface is associated with local surface restructuring. Density-functional theory calculations indicate that the chiral specificity of the dimer formation process is driven by the optimization of three bonds on each cysteine molecule. These findings thus provide a clear molecular-level illustration of the well known three-point contact model for chiral recognition in a simple bimolecular system.

Cysteine↗

Simultaneous in situ total internal reflectance fluorescence/atomic force microscopy studies of DPPC/dPOPC microdomains in supported planar lipid bilayers.

In situ simultaneous total internal reflectance fluorescence and in situ scanning probe microscopy performed on a phase-segregated supported planar lipid bilayer enabled direct in situ real-time correlated topographical and fluorescence images of nanometer-sized gel and fluid-phase lipid domains, presaging future in situ studies of membrane protein assemblies by single molecule imaging.

1,2-Dipalmitoylphosphatidylcholine↗

Atomic force microscopy of DNA, nucleoproteins and cellular complexes: the use of functionalized substrates.

Progress towards rapid and simple characterization of biomolecular samples by scanning probe microscopy is impeded mainly by limitations of the current approach to sample preparation. We are working on approaches based on chemical functionalization of mica. Treatment of mica with aminopropyltriethoxy silane (APTES) makes the surface positively charged (AP-mica) and able to hold DNA in place for imaging, even in water. We have shown that AP-mica is an appropriate substrate for numerous nucleoprotein complexes as well. The AFM images of the complex of DNA with RecA protein are stable and indicate a structural periodicity for this filament. AP-mica holds strongly such large DNA complexes as kinetoplast DNA (kDNA) and is an appropriate substrate for their imaging with AFM. We have further develop this approach for making hydrophobic substrates. Silylation of mica surface with hexamethyldisilazane (Me-mica) allowed us to get AFM images of chlorosomes, an antenna complex isolated from green photosynthetic bacteria. Me-mica may be converted into a positively charged substrate after treatment with water solutions of tetraethylammonium bromide or cetyltrimethylammonium bromide. These activated surfaces show high activity towards binding the DNA molecules.

Aluminum Silicates↗

Carbon nanotube scanning probe for imaging in aqueous environment.

Carbon nanotubes (CNTs) used as a probe for scanning probe microscopy has become one of the many potential usages of CNTs that is finding real applications in scientific research and industrial communities. It has been proposed that the unique mechanical buckling properties of the CNT would lessen the imaging force exerted on the sample and, thus, make CNT scanning probes ideal for imaging soft materials, including biological samples in liquid environments. The hydrophobic nature of the CNT graphitic sidewall is clearly chemically incompatible with the aqueous solution requirements in some biological imaging applications. In this paper, we present electron micrograph results demonstrating the instability of CNT scanning probes when submerged in aqueous solution. Moreover, we also introduce a novel approach to resolve this chemical incompatibility problem. By coating the CNT probe with ethylenediamine, thus rendering the CNT probe less hydrophobic, we demonstrate the liquid imaging capability of treated CNT probes. Experimental data for imaging in aqueous solutions are presented, which include an ultrathin Ir film and DNA molecules on a mica surface.

Ethylenediamines↗

Thermal imaging of composites.

Active thermal imaging techniques and their applications to composite materials are reviewed. The techniques included are transient thermography, scanning thermal microscopy and scanning thermal probe microscopy. The factors that affect the images produced by both pulsed and periodic forms of active heating are considered. For pulsed heating, experimental and numerical modelling results for carbon fibre-reinforced plastic are used to show how the resolution of subsurface features depends on their size and depth and on the anisotropy in thermal materials properties common in such composites. For periodic heating, thermal wave characteristics are introduced to show how the resolution of subsurface features also depends on modulation frequency and focal spot radius. Examples are given of the applications of scanning thermal microscopy and scanning thermal probe microscopy that illustrate the potential of these techniques for the imaging of composite materials.

Journal Article↗

Monolayer assemblies of a de novo designed 4-alpha-helix bundle carboprotein and its sulfur anchor fragment on Au(111) surfaces addressed by voltammetry and in situ scanning tunneling microscopy.

Mapping and control of proteins and oligonucleotides on metallic and nonmetallic surfaces are important in many respects. Electrochemical techniques based on single-crystal electrodes and scanning probe microscopies directly in aqueous solution (in situ SPM) have recently opened perspectives for such mapping at a resolution that approaches the single-molecule level. De novo design of model proteins has evolved in parallel and holds promise for testing and controlling protein folding and for new tailored protein structural motifs. In this report we combine these two strategies. We present a scheme for the synthesis of a new 4-alpha-helix bundle carboprotein built on a galactopyranoside derivative with a thiol anchor aglycon suitable for surface immobilization on gold. The carboprotein with thiol anchor in monomeric and dimeric (disulfide) form, the thiol anchor alone, and a sulfur-free 4-alpha-helix bundle carboprotein without thiol anchor have been prepared and investigated for comparison. Cyclic and differential pulse voltammetry (DPV) of the proteins show desorption peaks around -750 mV (SCE), whereas the thiol anchor desorption peak is at -685 mV. The peaks are by far the highest for thiol monomeric 4-alpha-helix bundle carboprotein and the thiol anchor. This pattern is supported by capacitance data. The DPV and capacitance data for the thiolated 4-alpha-helix bundle carboproteins and the thiol anchor hold a strong Faradaic reductive desorption component as supported by X-ray photoelectron spectroscopy. The desorption peak of the sulfur-free 4-alpha-helix bundle carboprotein, however, also points to a capacitive component. In situ scanning tunneling microscopy (in situ STM) of the thiol anchor discloses an adlayer with small domains and single molecules ordered in pin-striped supramolecular structures. In situ STM of thiolated 4-alpha-helix bundle carboprotein monomer shows a dense monolayer in a broad potential range on the positive side of the desorption potential. The coverage decreases close to this potential and single-molecule structures become apparent. The in situ STM contrast is also strengthened, indicative of a new redox-based tunneling mechanism. The data overall suggest that single-molecule mapping of natural and synthetic proteins on well-characterized surfaces by electrochemistry and in situ STM is within reach.

Amino Acid Sequence↗

AFM imaging in solution of protein-DNA complexes formed on DNA anchored to a gold surface.

A chemical procedure for anchoring DNA molecules to gold surfaces was used to facilitate the imaging of DNA and DNA-protein complexes in buffer solution by tapping mode atomic force microscopy (TMAFM). For preparing flat gold surfaces, a novel approach was employed by evaporating small amounts of gold onto freshly cleaved mica to give flat films that were stable under aqueous buffer conditions. The thickness of the investigated films ranged from 1 to 10 nm. For typical films of 4-6 nm, which were stable under aqueous buffer conditions, the root mean square (RMS) roughness ranged between 0.25 and 0.5 nm, as measured by atomic force microscopy (AFM). This roughness is comparable to that of obtained by the template stripped gold (TSG) technique, which is widely used in scanning probe microscopy but involves more preparation steps. In order to visualize DNA and DNA-protein complexes by TMAFM, the DNA was chemisorbed to the gold surface through a linker carrying a terminal thiol group at the 5'-end of each of the DNA strands. The modified DNA fragments were bound to the gold films and imaged in buffer solution, while unmodified DNA could not be visualized. Since the DNA was not dried during the process, it can be assumed that its native conformation was retained. This mode of anchoring did not prevent interaction with proteins, as confirmed by the observation that the topology of a complex formed by adding the protein to a surface-anchored DNA was the same as that obtained by anchoring a pre-formed complex to the gold surface. We attribute this observation to the fact that the DNA is anchored to the gold surfaces only through its ends, therefore the DNA-support interaction is minimized but imaging is still possible.

Bacterial Proteins↗

EC STM investigations of corrosion due to chloride solutions on thin CrN coatings.

The focus of the investigations presented is to evaluate local alterations caused by chloride ions affecting thin, magnetron-sputtered CrN layers. Scanning-probe microscopy and analysis techniques are used for this estimation. Thin CrN layers were deposited by reactive magnetron sputtering. They were investigated in electrochemical scanning tunnelling microscopy (EC STM) by cyclic voltammetry in 1 mol L(-1) NaCl. Simultaneously, the surface topography changes were recorded with STM. Above 100 mV the anodic oxidation leads to formation of chromium(III) hydroxide and at sample potentials above 350 mV oxidation of Cr(OH)(2) and Cr(OH)(3) towards chromium(VI) as a soluble chromate starts. Transpassive dissolution of the coating takes place above 900 mV. Yellow colour of the electrolyte is a visible sign for the formation of chromium(VI). Changes of the surface topography indicate the formation of surface layers at anodic potentials. At cathodic potentials increase in current is measured due to the reduction of chromium(III) hydroxide to divalent chromium and metallic chromium. Roughness of surface topography increases.Follow-up explorations with scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), atomic-force microscopy (AFM), scanning tunnelling microscopy/scanning tunnelling spectroscopy (STM/STS) and X-ray photoelectron spectroscopy (XPS) not only evidence the formation of various chromium oxides, but also indicate the existence of chromium hydroxide.

Journal Article↗

Self-sensing piezoresistive cantilever and its magnetic force microscopy applications.

A newly developed Si self-sensing piezoresistive cantilever is presented. Si piezoresistive cantilevers for scanning microscopy are fabricated by Si micro-machining technique. The sensitivity of the piezoresistive cantilever is comparable to the current laser detecting system. Topographic images are successfully obtained with the piezoresistive cantilever and some comparisons are made with the laser detecting system. Furthermore, the magnetic film (Co-Cr-Pt) is coated on the tip of the piezoresistive cantilever for magnetic force microscopy (MFM) application. The magnetic images are successfully obtained with the self-sensing MFM piezoresistive cantilever. The self-sensing piezoresistive cantilevers have been successfully applied in scanning probe microscopy and MFM.

Journal Article↗

Near-field infrared imaging and spectroscopy of a thin film polystyrene/poly(ethyl acrylate) blend.

The application of broadband, near-field infrared microscopy to the characterization of the mesoscale structure of a thin film polymer blend is described. Key features of this instrument, which couples the nanoscale spatial resolution of scanning probe microscopy with the chemical specificity of vibrational spectroscopy, include broad tunability and bandwidth, parallel spectral detection for high image acquisition rates, and infrared-transparent aperture probes. Nearfield spectral transmission images of a thin film of polystyrene/poly(ethyl acrylate) acquired in the C-H stretching region are reported. An assessment of the relative importance of transmission image contrast mechanisms is a significant aim of this work. Analysis of the near-field infrared spectra indicates that the image contrast in the C-H stretching region is largely due to near-field coupling and/or scattering effects. Identification and differentiation of the operative contrast mechanisms on the basis of their relative dependence on wavelength is discussed. Analysis of the contrast attributed to absorption is consistent with the chemical morphology of this sample derived from previous chemical modification/atomic force microscopy studies.

Journal Article↗

Monolayers of a de novo designed 4-alpha-helix bundle carboprotein and partial structures on Au(111)-surfaces.

Mapping of structure and function of proteins adsorbed on solid surfaces is important in many contexts. Electrochemical techniques based on single-crystal metal surfaces and in situ scanning probe microscopies (SPM) have recently opened new perspectives for mapping at the single-molecule level. De novo design of model proteins has evolved in parallel and holds promise for test and control of protein folding and for new tailored protein structural motifs. These two strategies are combined in the present report. We present a synthetic scheme for a new 4-alpha-helix bundle carboprotein built on a galactopyranoside derivative with a thiol anchor aglycon suitable for surface immobilization on gold. The galactopyranoside with thiol anchor and the thiol anchor alone were prepared for comparison. Voltammetry of the three molecules on Au(111) showed reductive desorption peaks caused by monolayer adsorption via thiolate-Au bonding. In situ STM of the thiol anchor disclosed an ordered adlayer with clear domains and molecular features. This holds promise, broadly for single-molecule voltammetry and the SPM and scanning tunnelling microscopy (STM) of natural and synthetic proteins.

Electrochemistry↗

Novel methods for studying lipids and lipases and their mutual interaction at interfaces. Part I. Atomic force microscopy.

Mono-layers of lipids and their interaction with surface active enzymes (lipases) have been studied for more than a century. During the past decade new insight into this area has been obtained due to the development of scanning probe microscopy. This novel method provides direct microscopic information about the system in question and allows in situ investigations under near physiological conditions. In the present review the theory, experimental set-up and sample requirements of atomic force microscopy (AFM) are described. An overview of recent results is also presented with special emphasis on lipase hydrolysis and kinetics investigated in situ using AFM.

1,2-Dipalmitoylphosphatidylcholine↗

Effect of molecular weight on synthesis and surface morphology of high-density poly(ethylene glycol) grafted layers.

This work describes studying the permanent grafting of carboxylic acid end-functionalized poly(ethylene glycol) methyl ether (PEG) chains of different molecular weights from the melt onto a surface employing poly(glycidyl methacrylate) ultrathin film as an anchoring layer. The grafting led to the synthesis of the complete PEG brushes possessing exceptionally high grafting density. The maximum thickness of the attached PEG films was strongly dependent on the length of the polymer chains being grafted. The maximum grafting efficiency was close to the critical entanglement molecular weight region for PEG. All grafted PEG layers were in the "brush regime", since the distance between grafting sites for the layers was lower than the end-to-end distance for the anchored macromolecules. Scanning probe microscopy revealed that the grafting process led to complete PEG layers with surface smoothness on a nanometric scale. Practically all samples were partly or fully covered with crystalline domains that disappeared when samples were scanned under water. Due to the PEG hydrophilic nature, the surface with the grafted layer exhibited a low (up to 21 degrees ) water contact angle.

Membranes, Artificial↗

Structure-dependent charge transport and storage in self-assembled monolayers of compounds of interest in molecular electronics: effects of tip material, headgroup, and surface concentration.

The electrical properties of self-assembled monolayers (SAMs) on a gold surface have been explored to address the relation between the conductance of a molecule and its electronic structure. We probe interfacial electron transfer processes, particularly those involving electroactive groups, of SAMs of thiolates on Au by using shear force-based scanning probe microscopy (SPM) combined with current-voltage (i-V) and current-distance (i-d) measurements. Peak-shaped i-V curves were obtained for the nitro- and amino-based SAMs studied here. Peak-shaped cathodic i-V curves for nitro-based SAMs were observed at negative potentials in both forward and reverse scans and were used to define the threshold tip bias, V(TH), for electric conduction. For a SAM of 2',5'-dinitro-4,4'-bis(phenylethynyl)-1-benzenethiolate, VII, V(TH) was nearly independent of the tip material [Ir, Pt, Ir-Pt (20-80%), Pd, Ni, Au, Ag, In]. For all of the SAMs studied, the current decreased exponentially with increasing distance, d, between tip and substrate. The exponential attenuation factors (beta values) were lower for the nitro-based SAMs studied here, as compared with alkylthiol-based SAMs. Both V(TH) and beta of the nitro-based SAMs also depended strongly on the molecular headgroup on the end benzene ring addressed by the tip. Finally, we confirmed the "memory" effect observed for nitro-based SAMs. For mixed SAMs of VII and hexadecanethiol, I, the fraction of the charge collected in the negative tip bias region that can be read out at a positive tip bias on reverse scan (up to 38%) depended on the film composition and decreased with an increasing fraction of I, suggesting that lateral electron hopping among molecules of VII occurs in the vicinity of the tip.

Journal Article↗

Ultraflat carbon film electrodes prepared by electron beam evaporation.

A facile method for the preparation of thin-film carbon electrodes by electron beam evaporation onto highly doped silicon is presented. The physical and electrochemical properties of these films both before and after postdeposition pyrolysis are investigated. Raman spectroscopy establishes the amorphous structure of the nonpyrolyzed carbon films and confirms the formation of graphitic carbon after pyrolysis at 1000 degrees C. Scanning force microscopy reveals the root-mean-square roughness of nonpyrolyzed films to be approximately 1 A, while pyrolyzed films exhibit an increased roughness of approximately 4 A. The electrochemical behavior of the electrodes resembles glassy carbon, with measured heterogeneous electron-transfer rate constants among the highest measured for thin carbon films. These carbon film electrodes will potentially find applications in such fields as molecular electronics and scanning probe microscopy of adsorbed species.

Journal Article↗

Inherent bias in correlation averaged images.

The correlation averaging algorithm frequently used to enhance micrographs of repeating structures contains an inherent bias that favours images with larger pixel values or positive noise levels. This bias not only skews the composite image toward higher pixel values, but also distorts the image by increasing the value of high-valued pixels more than that of low-valued pixels. These errors are especially important in scanning probe microscopy images where the pixel value reflects a distinct height. A similar algorithm that uses a structure function in place of the correlation function eliminates this bias.

Bias↗

Covalently functionalized nanotubes as nanometre-sized probes in chemistry and biology.

Carbon nanotubes combine a range of properties that make them well suited for use as probe tips in applications such as atomic force microscopy (AFM). Their high aspect ratio, for example, opens up the possibility of probing the deep crevices that occur in microelectronic circuits, and the small effective radius of nanotube tips significantly improves the lateral resolution beyond what can be achieved using commercial silicon tips. Another characteristic feature of nanotubes is their ability to buckle elastically, which makes them very robust while limiting the maximum force that is applied to delicate organic and biological samples. Earlier investigations into the performance of nanotubes as scanning probe microscopy tips have focused on topographical imaging, but a potentially more significant issue is the question of whether nanotubes can be modified to create probes that can sense and manipulate matter at the molecular level. Here we demonstrate that nanotube tips with the capability of chemical and biological discrimination can be created with acidic functionality and by coupling basic or hydrophobic functionalities or biomolecular probes to the carboxyl groups that are present at the open tip ends. We have used these modified nanotubes as AFM tips to titrate the acid and base groups, to image patterned samples based on molecular interactions, and to measure the binding force between single protein-ligand pairs. As carboxyl groups are readily derivatized by a variety of reactions, the preparation of a wide range of functionalized nanotube tips should be possible, thus creating molecular probes with potential applications in many areas of chemistry and biology.

Biology↗

Atomic force microscopy of the myosin molecule.

Atomic force microscopy (AFM) has been used to study the structure of rabbit skeletal muscle myosin deposited onto a mica substrate from glycerol solution. Images of the myosin molecule have been obtained using contact mode AFM with the sample immersed in propanol. The molecules have two heads at one end of a long tail and have an appearance similar to those prepared by glycerol deposition techniques for electron microscopy, except that the separation of the two heads is not so well defined. The average length of the tail (155 +/- 5 nm) agrees well with previous studies. Bends in the myosin tail have been observed at locations similar to those observed in the electron microscope. By raising the applied force, it has been possible locally to separate the two strands of the alpha-helical coiled-coil tail. We conclude that the glycerol-mica technique is a useful tool for the preparation of fibrous proteins for examination by scanning probe microscopy.

Aluminum Silicates↗