Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial.

A prospective, randomized, blinded clinical trial was done to evaluate polyethylene versus metal bearing surfaces in total hip replacement. Forty-one patients were randomized to receive either a metal (23 patients) or a polyethylene (18 patients) insert. The femoral and acetabular components were identical with the acetabular insert the only variable. Patients were assessed preoperatively and postoperatively using radiographs, multiple outcome measures (Western Ontario MacMaster University Score, Harris hip score, Short Form-12), erythrocyte metal ion analysis (cobalt, chromium, titanium), and urine metal ion analysis (cobalt, chromium, titanium). Patients were followed up for a minimum of 2 years (mean 3.2 years; range, 2.2-3.9 years). There were no differences in radiographic outcomes or outcome measurement tools between patients. Patients receiving a metal-on-metal articulation had significantly elevated erythrocyte and urine metal ions compared with patients receiving a polyethylene insert. Patients who had metal-on-metal inserts had on average a 7.9-fold increase in erythrocyte cobalt, a 2.3-fold increase in erythrocyte chromium, a 1.7-fold increase in erythrocyte titanium, a 35.1-fold increase in urine cobalt, a 17.4-fold increase in urine chromium, and a 2.6-fold increase in urine titanium at 2 years followup. Patients receiving a polyethylene insert had no change in erythrocyte titanium, urine cobalt, or urine chromium and a 1.5-fold increase in erythrocyte cobalt, a 2.2-fold increase in erythrocyte chromium, and a 4.2-fold increase in urine titanium. Forty-one percent of patients receiving metal-on-metal articulations had increasing metal ion levels at the latest followup.

Arthroplasty, Replacement, Hip↗

Migration of metal-on-metal versus ceramic-on-polyethylene hip prostheses.

In a prospective randomized study, 32 metal-on-metal prostheses and 29 ceramic-on-polyethylene prostheses of similar design were implanted in 59 patients. Radiolucency, cup migration, wear, and function were examined after a minimum of 2 years followup (followup rate, 87%). The purpose of the current study was to evaluate whether higher frictional torque of metal-on-metal will lead to a higher rate of early metal-on-metal cup loosening. A computer-assisted method was used for wear and migration measurements of the acetabular component. Metal-on-metal prostheses migrated in a craniocaudad direction significantly less than ceramic-on-polyethylene prostheses. The mean total migration for both types of prostheses exceeded 1.5 mm at 2 years. Clinically, no difference between the two prostheses regarding activity, pain, or range of motion was found at 2 years. As migration of metal-on-metal prostheses was not higher in comparison with ceramic-on-polyethylene prostheses, the expected higher frictional torque of metal-on-metal prostheses did not increase migration during short-term followup. The different debris produced by both bearings did not influence the short-term results of this study, but might cause different long-term results.

Aged↗

Metal-on-metal total hip replacement.

Metal-on-metal bearings have wear rates that are 20 to 100 times lower than metal-on-conventional polyethylene. The amount of wear generally is the same order of magnitude for the head and the cup. There is an initial run-in period of higher wear followed by lower, steady-state wear. Wear rate is a function of the interplay of material(s), macrogeometry, microgeometry, and the resultant type and amount of lubrication. The wear resistance and clinical performance of a metal-on-metal bearing are more sensitive to macrogeometry and lubrication than a metal-on-polyethylene bearing. Metal wear particles are nanometers in linear dimension. They are much smaller and more numerous than the submicron polyethylene wear particles, but the volume of periprosthetic inflammatory tissue is less. Osteolysis seems to be relatively rare. Little is known about the systemic distribution of metal particles and ions. The significance of systemic distribution also is not known. The levels of serum and urine Co and Cr ions are elevated in patients with metal-on-metal bearings, but the long-term, steady-state levels are not much higher than those from corrosion of modular femoral components. Because of the elevated levels of Co and Cr ions, there is a greater risk of delayed type hypersensitivity. There also is concern about the potential for malignant degeneration secondary to prolonged exposure to these elements. The available data are insufficient to address this concern. Rigorous long-term studies are needed. It will take decades of close clinical observation to determine if the benefits of metal-on-metal bearings outweigh the associated risks.

Animals↗

The wear of metal-on-metal total hip prostheses measured in a hip simulator.

New generation metal-on-metal prostheses have been introduced to try and overcome the problem of osteolysis often attributed to the wear particles of the polyethylene component of conventional metal-on-ultra-high molecular weight polyethylene (UHMWPE) joints. The wear rates of four metal-on-metal joints (two different clearances) were assessed along with that of a conventional metal-on-UHMWPE joint. Friction measurements of the metal-on-metal joints were taken before and after the wear test and compared. Two distinct wear phases were discernible for all the metal-on-metal joints: an initial wear phase up to 0.5 x 10(6) cycles and then a lower steady state wear phase. The steady state wear rate of the 22 microm radial clearance metal-on-metal joint was lower than that for the 40 microm radial clearance joint, although this difference was not found to be significant (p > 0.15). The wear rates for all the joints tested were consistent with other simulator studies. The friction factors produced by each joint were found to decrease significantly after wear testing (p < 0.05).

Biocompatible Materials↗

Environmentally relevant metal and transition metal ions enhance Fc epsilon RI-mediated mast cell activation.

Upon contact with allergen, sensitized mast cells release highly active proinflammatory mediators. Allergen-mediated mast cell activation is an important mechanism in the pathogenesis of atopic asthma. Asthmatic patients are especially susceptible to air pollution. Epidemiologic studies found a positive correlation between severity of symptoms among asthmatic patients and the level of particulate matter (PM) in the air. Among the constituents of PM are metals and transition metals, which could mediate some of its adverse effects on human health. We sought to determine the effect of metal and transition metal ions on allergen-mediated mast cell activation. We observed that several metal and transition metal ions activated mast cells and enhanced allergen-mediated mast cell activation. Thus, Al(3+), Cd(2+), and Sr(2+) induced release of granule-associated N-acetyl-ss-d-hexosaminidase, and Al(3+) and Ni(2+) enhanced antigen-mediated release. Metal and transition metal ions also induced significant secretion of interleukin (IL)-4 and increased antigen-mediated IL-4 secretion in mast cells. These effects of metal and transition metal ions on mast cells were observed at concentrations that do not result in direct cytotoxicity and might be relevant for environmental exposure. Thus, metals and transition metals could increase the level of allergen-mediated mast cell activation, which might be one of the mechanisms mediating exacerbation of allergen-driven asthma symptoms by air pollution.

Air Pollutants↗

Experimental and modeling investigation of metal release from metal-spiked sediments.

In sediments that contain iron monosulfide, cadmium, nickel, lead, zinc, and silver(I) form insoluble metal sulfides that lower the metal ion activity in the sediment-pore water system, thereby reducing toxicity. However, metal sulfides are susceptible to oxidation by molecular oxygen resulting in metal solubilization. To better understand the sources and sinks of metal sulfides in sediments, iron monsulfide-rich freshwater sediments were spiked with cadmium, nickel, lead, zinc, or silver(I) and placed into cylindrical cores with an overlying layer of oxygen-saturated water. Measurements of the dissolved metal concentration in the overlying water were made as a function of time and the vertical profiles of acid-volatile sulfide (AVS) and simultaneously extracted metal (SEM) were measured after 150 d. A one-dimensional reactive and transport model has been employed to help elucidate processes controlling the fate of metals in sediments. The model incorporates metal-sulfide formation, metal-sulfide oxidation, and metal partitioning onto sediment organic carbon and iron oxyhydroxide to simulate the vertical transport of metals throughout the sediment core.

Acids↗

Serum cobalt levels after metal-on-metal total hip arthroplasty.

BACKGROUND: Systemic cobalt dissemination from the Metasul Co-28Cr-6Mo-0.2C metal-on-metal total hip prosthesis has been demonstrated in the first year after implantation. The aim of this prospective study was to monitor the serum cobalt concentrations in patients during the first five years after total hip arthroplasty with a metal-on-metal articulation. METHODS: A total hip arthroplasty was performed without cement in 100 consecutive patients who had either unilateral osteoarthritis or unilateral osteonecrosis. Fifty patients were randomized to be treated with a metal-on-metal articulation, and fifty patients, with a ceramic-on-polyethylene bearing. The femoral stem was made of a Ti-6Al-7Nb alloy, and the threaded acetabular cup was made of commercially pure titanium. Blood samples were taken before the operation and at multiple time-points for five years after the operation. Serum cobalt concentrations were measured with use of atomic absorption spectrometry. RESULTS: In the metal-on-metal group, the median serum cobalt concentration was 1 micro g/L at one year after surgery and 0.7 micro g/L at five years. The median of the serum cobalt concentrations measured from three to twelve months did not differ from the median of subsequent measurements, with the numbers available. The median serum cobalt level in the control group of patients treated with the ceramic-on-polyethylene articulation was below the detection limit at all time-points. CONCLUSIONS: Systemic cobalt release from Metasul metal-on-metal articulations was demonstrated throughout the five-year study period. The median serum cobalt concentrations were found to be slightly above the detection limit and remained in a constant range. The serum cobalt concentrations did not reflect a so-called run-in wear period of the metal-on-metal articulations.

Adolescent↗

Metal-on-metal hybrid surface arthroplasty. Surgical Technique.

BACKGROUND: Following the reintroduction of metal-on-metal articulating surfaces for total hip arthroplasty in Europe in 1988, we developed a surface arthroplasty prosthetic system using a metal-on-metal articulation. The present study describes the clinical and radiographic results of the first 400 hips treated with metal-on-metal hybrid surface arthroplasties at an average follow-up of three and a half years. METHODS: Between November 1996 and November 2000, 400 metal-on-metal hybrid surface arthroplasties were performed in 355 patients. All femoral head components were cemented, but only fifty-nine of the short metaphyseal stems were cemented. The patients had an average age of forty-eight years, 73% were men, and 66% had a diagnosis of osteoarthritis. Clinical and radiographic follow-up was performed at three months postoperatively and yearly thereafter. RESULTS: The majority of the patients returned to a high level of activity, including sports, and 54% had activity scores of >7 on the University of California at Los Angeles activity assessment system. Kaplan-Meier survivorship curves demonstrated that the rate of survival of the components at four years was 94.4%. For patients with a surface arthroplasty risk index score of >3, the rate of survival of the components at four years was 89% compared with a rate of 97% for those with a score of <or=3. The patients with a higher risk index were 4.2 times more likely to undergo revision to a total hip replacement at four years. Twelve hips (3%) had a revision to a total hip replacement. Seven of the twelve hips were revised because of loosening of the femoral component, and three were revised because of a femoral neck fracture. Substantial radiolucencies were seen around sixteen uncemented metaphyseal femoral stems. No femoral radiolucencies were observed among the hips in which the metaphyseal stem was cemented. The most important risk factors for femoral component loosening and substantial stem radiolucencies were large femoral head cysts (p = 0.029), patient height (p = 0.032), female gender (p = 0.005), and smaller component size in male patients (p = 0.005). CONCLUSIONS: The preliminary experience with this hybrid metal-on-metal bearing is encouraging. Optimal femoral bone preparation and component fixation are critical to improving durability. The metal-on-metal hybrid surface arthroplasty is easily revised to a standard femoral component if necessary.

Adolescent↗

Metal surface treatment: characterization and effect on composite-to-metal bond strength.

This study evaluated the effect of four methods of metal surface preparation and the use of silane on the bond strength between resin and a Noble metal alloy. SEM Examination and x-ray energy-dispersive spectroscopy (EDS) of the various metal surface treatments was also performed. One-hundred metal disks were cast in a Noble metal alloy (Porcelain #76). Ninety disks were polished flat and the surfaces received one of four abrasive treatments (n = 20). 1) Roughening with a diamond bur at high speed; 2) Air abrasion with an intraoral sandblaster using alumina particles; 3) Air abrasion with KCP-2000 and 4) Air abrasion with an intraoral sandblaster using silanated silica covered alumina particles (CoJet-Sand). Half the specimens from each treatment group (n = 10) were silanated prior to bonding procedures (All-Bond 2 adhesive system, Pertac-Hybrid composite). Specimens were stored in distilled water at 37 degrees C and thermocycled prior to shear strength testing. The 10 remaining metal disks were used for scanning electron microscopy and x-ray energy-dispersive spectroscopy (EDS). Scanning electron microscopy examined the micromorphology of the metal surfaces produced by the four abrasive treatments and x-ray energy-dispersive spectroscopy (EDS) to evaluate changes in surface composition. Two untreated disks served as controls. One-way ANOVA and Tukey's HSD post-hoc test demonstrated that air abrasion with CoJet-Sand and silane resulted in significantly higher resin-to-metal bond strength than all other metal surface treatments, while roughening with a diamond bur produced the lowest bond strength. Resin-to-metal bond strength was similar for all other particle abrasive treatments with or without silane. Using silane significantly improved bond strength only for metal surfaces treated with CoJet-Sand. An increase in Al concentration was observed on metal surfaces sandblasted with aluminum oxide, and an increase in the concentration of both Al and Si was observed on surfaces air-abraded with CoJet-Sand.

Air↗

Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study.

BACKGROUND: Following the reintroduction of metal-on-metal articulating surfaces for total hip arthroplasty in Europe in 1988, we developed a surface arthroplasty prosthetic system using a metal-on-metal articulation. The present study describes the clinical and radiographic results of the first 400 hips treated with metal-on-metal hybrid surface arthroplasties at an average follow-up of three and a half years. METHODS: Between November 1996 and November 2000, 400 metal-on-metal hybrid surface arthroplasties were performed in 355 patients. All femoral head components were cemented, but only fifty-nine of the short metaphyseal stems were cemented. The patients had an average age of forty-eight years, 73% were men, and 66% had a diagnosis of osteoarthritis. Clinical and radiographic follow-up were performed at three months postoperatively and yearly thereafter. RESULTS: The majority of the patients returned to a high level of activity, including sports, and 54% had activity scores of >7 on the University of California at Los Angeles activity assessment system. Kaplan-Meier survivorship curves demonstrated that the rate of survival of the components at four years was 94.4%. For patients with a surface arthroplasty risk index score of >3, the rate of survival of the components at four years was 89% compared with a rate of 97% for those with a score of </=3. The patients with a higher risk index were 4.2 times more likely to undergo revision to a total hip replacement at four years. Twelve hips (3%) had a revision to a total hip replacement. Seven of the twelve hips were revised because of loosening of the femoral component, and three were revised because of a femoral neck fracture. Substantial radiolucencies were seen around sixteen uncemented metaphyseal femoral stems. No femoral radiolucencies were observed among the hips in which the metaphyseal stem was cemented. The most important risk factors for femoral component loosening and substantial stem radiolucencies were large femoral head cysts (p = 0.029), patient height (p = 0.032), female gender (p = 0.005), and smaller component size in male patients (p = 0.005). CONCLUSIONS: The preliminary experience with this hybrid metal-on-metal bearing is encouraging. Optimal femoral bone preparation and component fixation are critical to improving durability. The metal-on-metal hybrid surface arthroplasty is easily revised to a standard femoral component if necessary. LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Adolescent↗

The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

The metal-on-metal articulations in total hip arthroplasty (THA) were widely used between 1960 and 1975. The McKee-Farrar and other first-generation prostheses failed at a high rate because impingement caused early component loosening. The problem of early component loosening was corrected by improved component design and better manufacturing quality. Second-generation metal-on-metal total hip replacements have experienced short and medium-term success as assessed by Harris Hip Scores and patient self-assessment. The combined annual linear wear of the metal-on-metal femoral head and acetabular insert is less than 10 mm and osteolysis has only rarely been observed in association with well-fixed metal-on-metal total hip replacements. Hypersensitivity is not a common cause of loosening with second-generation hip replacements and remains to be proven as a definitive diagnosis in unusual cases of unexplained pain. More than 40 years of use has demonstrated no increase in the incidence of renal failure or cancer in patients with metal-on-metal total hip replacements. The scientific evidence of the results using the metal-on-metal articulations would recommend its continued use in any patient who does not have compromised renal function.

Arthroplasty, Replacement, Hip↗

A single-site model for divalent transition and heavy metal adsorption over a range of metal concentrations.

Metal adsorption data over a range of surface coverages typically are characterized by curvilinear metal adsorption isotherms. These isotherms generally have a slope of 1 at low surface coverage and a shallower slope at higher surface coverages. The curvature of metal adsorption isotherms with increasing surface coverage is frequently interpreted in terms of sequential adsorption onto different types of surface sites, multinuclear surface complexation, or nonideality of metal adsorption. We demonstrate that the curvature of metal adsorption isotherms can also be attributed to changes in surface charge and potential that depend on the predominant type of metal surface complex. A single-site extended triple-layer model is used to reinterpret previously studied metal adsorption isotherms and pH edges for a wide variety of metals (Cd2+, Co2+, Cu2+, Pb2+, and Zn2+) and solids (goethite, hydrous ferric oxide, corundum, and magnetite) in different electrolyte solutions (NaNO3 and NaClO4). Only metal adsorption on ferrihydrite at very low surface coverages is not consistent with the single-site triple-layer model. This discrepancy might be explained if ferrihydrite is in fact not a single phase but a mixture of two or more phases. Metal surface coverages ranging from 10(-4) to 10.2 mmol/m2 on the other minerals can be accounted for with a single-site extended triple-layer model if appropriate metal adsorption reactions are chosen. In addition, several examples suggest that, within the context of the model, surface complexation schemes can be established that describe metal adsorption over both a wide range of surface coverage and a wide range of ionic strength.

Journal Article↗

Comparative wear under different conditions of surface-engineered metal-on-metal bearings for total hip arthroplasty.

Metal-on-metal hip arthroplasties have demonstrated low wear rates. However, the ion release and toxicity of the metal wear particles remains a concern. Modifying the surface of metal bearings with thick chromium nitride (CrN) coatings has the potential to further reduce wear and ion release, and improve the biocompatibility of wear particles produced. The aim of this study was to investigate the application of surface engineering technology to modify metal-on-metal (MOM) bearings to reduce wear and improve the functional biocompatibility of metal-on-metal prostheses. CrN-on-CrN bearings had lower wear rates in comparison to metal-on-metal bearings, particularly under adverse loading conditions. CrN-on-CrN bearings produced similar nanometer-sized particles to metal-on-metal bearings, however, CrN wear particles were less cytotoxic when cocultured with macrophage and fibroblast cells.

Arthroplasty, Replacement, Hip↗

Octanol-solubility of dissolved and particulate trace metals in contaminated rivers: implications for metal reactivity and availability.

The lipid-like, amphiphilic solvent, n-octanol, has been used to determine a hydrophobic fraction of dissolved and particulate trace metals (Al, Cd, Co, Cu, Mn, Ni, Pb, Zn) in contaminated rivers. In a sample from the River Clyde, southwest Scotland, octanol-solubility was detected for all dissolved metals except Co, with conditional octanol-water partition coefficients, D(ow), ranging from about 0.2 (Al and Cu) to 1.25 (Pb). In a sample taken from the River Mersey, northwest England, octanol-solubility was detected for dissolved Al and Pb, but only after sample aliquots had been spiked with individual ionic metal standards and equilibrated. Spiking of the River Clyde sample revealed competition among different metals for hydrophobic ligands. Metal displacement from hydrophobic complexes was generally most significant following the addition of ionic Al or Pb, although the addition of either of these metals had little effect on the octanol-solubility of the other. In both river water samples hydrophobic metals were detected on the suspended particles retained by filtration following their extraction in n-octanol. In general, particulate Cu and Zn (up to 40%) were most available, and Al, Co and Pb most resistant (<1%) to octanol extraction. Distribution coefficients defining the concentration ratio of octanol-soluble particle-bound metal to octanol-soluble dissolved metal were in the range 10(3.3)-10(5.3)mlg(-1). The presence of hydrophobic dissolved and particulate metal species has implications for our understanding of the biogeochemical behaviour of metals in aquatic environments. Specifically, such species are predicted to exhibit characteristics of non-polar organic contaminants, including the potential to penetrate the lipid bilayer. Current strategies for assessing the bioavailability and toxicity of dissolved and particulate trace metals in natural waters may, therefore, require revision.

Animals↗

[Metal serum levels in 48 patients bearing a chromium-cobalt total hip arthroplasty with a metal-on-polyethylene combination].

PURPOSE OF THE STUDY: Component wear and dissemination of wear debris, particularly with metal-on-metal combinations, is the predominant long-term complication of total hip arthroplasty. The purpose of our work was to search for metal pArticles released when using the metal-on-polyethylene combination by analyzing serum levels of chromium (Cr), cobalt (Co), nickel (Ni), and molybdium (Mo) in patients with a metal-on-polyethylene chromium-cobalt total hip arthroplasty. We compared the observed levels with those observed in a control population and studied changes as a function of signs of loosening. MATERIAL AND METHODS: During a thirty-Month period, 53 patients with degenerative hip disease underwent total hip arthroplasty. The same implant, PVL, being used for all hips. Forty-eight patients were available for analysis at a minimum follow-up of 32 Months. Results of the clinical and radiological examination of the operated hip were recorded. Serum metal levels were assayed by mass spectrometry on total blood samples. Patient activity was determined with the Devane classification and hip function with the Postel-Merle-d'Aubligné score; walking distance was recorded in kilometers. Signs of prosthetic loosening were identified on plain radiograms (AP and lateral views) searching for femoral and/or acetabular lucent lines, cement fracture, granuloma. The control group included 56 patients scheduled for total hip arthroplasty. Non-parametric statistical analysis was used to search for correlations between the clinical, radiological, and biological parameters. RESULTS: At mean 44 Months follow-up, 17% of the patients had a fair or mediocre function score and 37% had radiological signs of femoral component loosening. Serum cobalt increased significantly in the implanted group (serum cobalt >or=0.60 microg/L in 50% of patients) compared with the control group (serum cobalt >or=0.60 microg/L in 9%) (P<0.001, Mann-Whittney test). Increased serum cobalt was highest in patients with radiographic signs of loosening. This significant difference was not found for other metals. Patient activity, hip function, and follow-up were not correlated with serum levels. DISCUSSION: Serum cobalt appears to be a good biological marker of prosthetic function although intra- and inter-individual variations are influenced by assay technique, metal ion solubility, and metal dissemination in the organism. The metal-on-metal combination does not appear to be the only friction couple which increases the serum level of metal ions. Our results do not allow defining a time of latency between onset of radiographic signs and increased serum levels.

Aged↗

Density functional investigation of metal-metal interactions in d4d4 face-shared [M2Cl9]3 - (M = Mn, Tc, Re) systems.

The molecular and electronic structures of the d(4)d(4) face-shared [M(2)Cl(9)](3)(-) (M = Mn, Tc, Re) dimers have been calculated by density functional methods in order to investigate metal-metal bonding in this series. The electronic structures of these systems have been analyzed using potential energy curves for the broken-symmetry and other spin states arising from the various d(4)d(4) coupling modes, and closed energy cycles have been utilized to identify and quantify the parameters which are most important in determining the preference for electron localization or delocalization and for high-spin or low-spin configurations. In [Tc(2)Cl(9)](3)(-) and [Re(2)Cl(9)](3)(-), the global minimum has been found to be a spin-triplet state arising from the coupling of metal centers with low-spin configurations, and characterized by delocalization of the metal-based electrons in a double (sigma and delta(pi)) bond with a metal-metal separation of 2.57 A. In contrast, high-spin configurations and electron localization are favored in [Mn(2)Cl(9)](3)(-), the global minimum for this species being the ferromagnetic S = 4 state with a rather long metal-metal separation of 3.43 A. These results are consistent with metal-metal overlap and ligand-field effects prevailing over spin polarization effects in the Tc and Re systems, but with the opposite trend being observed in the Mn complex. The ground states and metal-metal bonding observed for the d(4)d(4) systems in this study parallel those previously found for the analogous d(2)d(2) complexes of V, Nb, and Ta, and can be rationalized on the basis that the d(4)d(4) dimer configuration is the hole equivalent of the d(2)d(2) configuration.

Journal Article↗

Determination of metal-metal distances: significance and accuracy.

Nature utilises a variety of metal clusters as catalytic centers. Some of them make use of two or more metals in the catalytic site. The variation of metal-metal distances plays an important role in several processes like charge transfer and weakening of bonds. X-ray absorption spectroscopy can determine these metal-metal distances in several states (crystal, solution or amorphous). However sometimes backscattering from light elements hides the metal-metal contribution to the fine structure. Here we point out significance and accuracy of metal-metal distances in a model system. Therefore a number of different refinement protocols are applied to the data. These protocols will be discussed focusing on the significance and accuracy of the metal-metal distances extracted from the data.

Journal Article↗

Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up.

BACKGROUND: Authors of recent studies have reported early periprosthetic osteolysis in patients who have been treated with a contemporary metal-on-metal total hip arthroplasty and have suggested that metal hypersensitivity associated with an immunologic response to metal may be of etiologic importance. We evaluated the results and histologic findings in patients who had undergone revision of a failed contemporary metal-on-metal total hip arthroplasty. METHODS: Two hundred and seventeen total hip arthroplasties (SL-Plus stem and Bicon-Plus cup) with a Sikomet metal-on-metal articulation were implanted in 194 consecutive patients, and the results were retrospectively reviewed at a mean of seventy-seven months postoperatively. Clinical follow-up with the Harris hip score and plain radiographic evaluation were performed. Periprosthetic tissues from fourteen hips that had undergone revision arthroplasty were subjected to histologic analysis. RESULTS: The mean Harris hip score improved from 45 points preoperatively to 88 points at the final evaluation. Fourteen hips (6.5%) were revised: nine because of aseptic loosening, two because of technical failure, and three because of septic failure. Histologic examination of the retrieved periprosthetic tissues from the eleven patients who had undergone revision because of aseptic loosening or technical failure showed metallosis and extensive lymphocytic and plasma-cell infiltration around the metal debris. With removal of the component because of aseptic loosening as the end point, survivorship was 93% for the stem and 98% for the cup. CONCLUSIONS: Our findings are in agreement with those in recent publications and support the possibility that periprosthetic osteolysis and aseptic loosening in hips with a metal-on-metal articulation are possibly associated with hypersensitivity to metal debris. Prospective, comparative, randomized long-term studies are necessary to determine the cause(s) of loosening of prostheses with this particular articulation.