Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid-Liquid Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Liquid chromatographic/mass spectrometric assay of rabeprazole in dog plasma for a pharmacokinetic study.

In order to evaluate the pharmacokinetic (PK) profile of rabeprazole (RA) sterile powder for injection, a rapid, sensitive and specific assay for quantitative determination of RA in dog plasma was developed and validated. After a liquid-liquid extraction procedure, samples were analyzed by liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) using omepazole as the internal standard (IS). The analyte and IS was chromatographed on a ZORBAX Extend-C(18) analytical column (50 x 2 mm i.d, 5 microm, Agilent Technologies, USA). The assay was linear in the range 1-2000 ng/mL. The lower limit of quantification of RA was 1 ng/mL. The recovery of RA was greater than 70%. The within- and between-batch accuracy was 102.7-107.4% and 103.5-105.7%, respectively. The plasma samples for the PK study were collected at defined time points during and after an intravenous injection (1 mg/kg) to beagle dogs and analyzed by LC-ESI-MS method. The PK parameters, such as half-life, volume of distribution, total clearance and elimination rate constant, were determined. The PK profile of RA gave insights into the application in the clinics.

2-Pyridinylmethylsulfinylbenzimidazoles↗

Determination of artemisinin in human serum by high-performance liquid chromatography with on-line UV irradiation and peroxyoxalate chemiluminescence detection.

Artemisinin is an antimalarial drug containing an internal endoperoxide linkage in its structure. A simple, selective and sensitive high-performance liquid chromatography (HPLC)-peroxyoxalate chemiluminescence (PO-CL) method for the determination of artemisinin was developed. This method is based on the fact that endoperoxide in artemisinin structure can be converted to hydrogen peroxide (H(2)O(2)) under ultraviolet (UV) irradiation and the generated hydrogen peroxide can be measured using PO-CL detection. The HPLC-PO-CL system was optimized on a mobile phase, post column chemiluminescence reagent, UV source and irradiation time. In addition, the system was combined with simple liquid-liquid extraction using n-hexane that allowed selective and sensitive determination of artemisinin in serum. The limit of detection using 0.5 mL of blood was 0.062 micromol/L (17.5 ng/mL) at a signal-to-noise ratio of 3. Calibration curve obtained for artemisinin in human serum 4-80 micromol/L (1.1-22.6 microg/mL) showed a good linearity (r = 0.999).

Artemisinins↗

Liquid chromatographic assay for the non-peptidic protease inhibitor tipranavir in plasma.

Tipranavir is the most recently introduced protease inhibitor for the suppression of the human immunodeficiency virus (HIV). A selective reversed-phase liquid chromatographic assay, previously developed for atazanavir, has been extended and validated for tipranavir in plasma. Compounds were isolated from a 500 microL plasma sample using liquid-liquid extraction with dichloromethane. After evaporation and reconstitution of the extract the sample was analysed using reversed-phase liquid chromatography and ultra violet detection at 280 nm. In the evaluated concentration range (0.2-50 microg/mL tipranavir), intra-day precisions were <or=8% and inter-day precisions were <or=10%. Accuracies between 95 and 108% were found. The clinical applicability of the assay was demonstrated in an HIV-infected patient who ingested 500 mg tipranavir bid in combination with 100 mg ritonavir.

Chromatography, Liquid↗

Micro-extraction techniques in analytical toxicology: short review.

This paper discusses new developments in plasma micro-extraction techniques in the context of established micro-extraction and protein precipitation methodology. Simple liquid-liquid solvent extraction (LLE) of plasma with direct GC or HPLC analysis of the resulting extract has been used for many years. Butyl acetate and methyl t-butyl ether (MTBE) give efficient extraction of many drugs and metabolites from small volumes of plasma or whole blood at an appropriate pH, and form the upper layer, thus simplifying extract removal. Butyl acetate does not interfere with NPD, ECD or MS in GC, whilst MTBE has a relatively low UV cutoff (220 nm). Thus, HPLC eluents that use a high proportion of an organic component allow MTBE extracts to be analysed directly. 'Salting-out' and extractive derivatization using acetic anhydride or phenylboronic acid can be used with appropriate analytes. As regards protein precipitation, an important consideration is lowering the pH, although this is not feasible with acid-labile analytes. More recent developments include sold-phase micro-extraction (SPME) and liquid-phase micro-extraction (LPME). This latter technique especially may prove invaluable as analytes that cannot easily be extracted with LLE can be isolated simply at low cost with a minimum of apparatus.

Chemical Precipitation↗

Validation of a simple HPLC method for DRF-4848, a novel COX-2 inhibitor suitable for pharmacokinetic application in rats.

For pharmacokinetic and toxicokinetic purpose a simple HPLC-UV method has been developed and validated for the estimation of DRF-4848, a novel COX-2 inhibitor in rat plasma. A liquid-liquid extraction was used to extract DRF-4848 and internal standard (IS, DRF-4367) from rat plasma. The analysis was performed on a C(18) column with UV detection at 285 nm. The isocratic mobile phase, 0.01 M potassium dihydrogen ortho phosphate (pH 3.2) and acetonitrile (50:50, v/v) was run at a flow rate of 1 mL/min. The retention times of DRF-4848 and IS were 6.8 and 11.2 min, respectively. Absolute recovery for analyte and IS was >80% from rat plasma. A linear response was observed over a concentration range 0.1-20 microg/mL. The lower limit of quantification (LLOQ) of DRF-4848 was 0.1 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.1, 0.3, 8.0 and 15.0 microg/mL, were in the range 1.74-8.70% relative standard deviation (RSD) and 0.75-8.43% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.29-116.51% of the nominal values. Analyte and IS were stable in the battery of stability studies viz., benchtop, autosampler, long-term and freeze/thaw cycles.

4-Butyrolactone↗

Liquid chromatographic-electrospray tandem mass spectrometric determination of clarithromycin in human plasma.

A rapid, sensitive and specific LC-MS-MS method has been developed for the determination of clarithromycin (CLA) in human plasma using roxithromycin (ROX) as the internal standard. Samples were prepared via liquid-liquid extraction with methyl tert-butyl ether (MTBE) and chromatographed on a Supelco RP(18) (4.6 x 50 mm, 3 microm particle size) column with a mobile phase consisting of acetonitrile:methanol:60 mM (pH 3.5) ammonium acetate buffer (32.5:32.5:35) at a constant flow rate of 0.8 mL/min. The run time was 3 min with retention times of approximately 1.65 and 1.70 min for CLA and ROX, respectively. Detection was performed on a PE Sciex API 365 mass spectrometer equipped with a turboionspray ionization source in multiple reaction monitoring (MRM) mode. The MRM pairs were m/z 748.5 --> m/z 158.2 for CLA and m/z 837.7 --> m/z 679.3 for ROX, respectively, with dwell times of 200 ms for each transition. The validated calibration curve range was 5.00-5000 ng/mL, based on 0.100 mL plasma sample volume with signal-to-noise ratio (S/N) greater than 60 for CLA at the lower limit of quantification level (5.00 ng/mL). The correlation coefficients (r(2)) of the calibration curves were better than or equal to 0.996. The inter-day (n = 18) precision and accuracy of the quality control (QC) samples were less than 3.58% RSD (relative standard deviation) and -10.8% bias, respectively. The intra-day (n = 6) precision and accuracy of the quality control samples were less than 5.0 and 12.6%, respectively. There was no significant deviation from the nominal values after a 10-fold dilution of high concentration QC samples using blank matrix. The QC samples were stable when left on the bench for 24 h or after three freeze-thaw cycles. The processed samples were also stable in HPLC autosampler at 10C for over 72 h. No matrix ionization suppression was observed when extracted blank matrix or reconstitution solvent was injected onto the system with post-column infusion of clarithromycin and roxithromycin. No carryover was observed when an extracted blank plasma sample was injected immediately after a 5000 ng/mL ULOQ (the upper limit of quantification) standard. The mean recovery was 81.5 and 78.3%, respectively, for clarithromycin and internal standard.

Chromatography, High Pressure Liquid↗

Validated HPLC method for determination of carboxylic acid metabolite of clopidogrel in human plasma and its application to a pharmacokinetic study.

A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.

Adult↗

Simultaneous determination of YM928, a novel noncompetitive AMPA receptor antagonist, and its demethylated metabolite in rat, dog and monkey plasma by high-performance liquid chromatography with ultraviolet detection.

A specific HPLC method for the simultaneous determination of YM928, a novel noncompetitive AMPA receptor antagonist, and its demethylated metabolite (YM-58875) in rat, dog and monkey plasma was developed and validated. The method utilized multiple-step liquid-liquid extraction followed by a reversed-phase HPLC with UV detection at 275 nm. No interfering peaks were observed at the retention times of YM928, YM-58875 or internal standard. The validated quantitation range was 5-5000 ng/mL for both YM928 and YM-58875 when 1 mL of the plasma sample was used. The intra- and inter-day precision was less than 5.3 and 2.5% for YM928, and 3.7 and 2.3% for YM-58875, respectively. The intra- and inter-day accuracies were -8.7-5.3% and 0.7-1.9% for YM928, and -10.0-6.1% and 1.3-3.4% for YM-58875, respectively. The mean recoveries in the extraction process were 52.7-62.8%. The utility of this analytical method was demonstrated by the investigation of the pharmacokinetics of the unchanged drug and its metabolite in preclinical studies.

Animals↗

Determination of coenzyme Q10 in human breast milk by high-performance liquid chromatography.

An isocratic HPLC method was developed for the determination of coenzyme Q(10) (CoQ(10)) in human breast milk. After a single-step liquid-liquid extraction, the milk extract was injected directly into the HPLC system. The analytical method is based on pre-column inline treatment of CoQ(10). Chromatographic separation of CoQ(10) and coenzyme Q(9) (CoQ(9)) internal standard was achieved using a reversed-phase Microsorb-MV C(18) analytical column. CoQ(10) and CoQ(9) were monitored by an electrochemical detector (ECD). An excellent linearity (r = 0.999) was observed for CoQ(10) in the concentration range 0.06-2.5 micromol L(-1) in breast milk. The limit of quantitation (LOQ) was 60 nmol L(-1). Coefficients of variations (CVs) for intra-day and inter-day assay precisions were less than 5%. A total of 194 breast milk samples were analyzed for the CoQ(10) concentration; the mean value was 0.32 +/- 0.21 micromol L(-1).

Chromatography, High Pressure Liquid↗

A simple and sensitive HPLC-fluorescence method for quantification of MDMA and MDA in blood with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a label.

A sensitive high-performance liquid chromatographic method with fluorescence detection to determine 3,4-methylenedioxymethamphethamine (MDMA) and 3,4-methylenedioxyamphethamine (MDA) in human and rat whole blood or plasma samples was developed by using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a label. MDMA and MDA in a small amount of blood sample (ca 100 microL) were extracted by liquid-liquid extraction with ethyl acetate, and were derivatized with DIB-Cl under mild conditions (10 min at room temperature). A good separation of DIB-derivatives could be achieved within 45 min using a commercially available ODS column with an isocratic eluent of 10 mM citric acid-20 mM Na(2)HPO(4) aqueous buffer (pH 4.0)-CH(3)CN-CH(3)OH (50:45:5, v/v/v %). The calibration curves prepared with 1-methyl-3-phenylpropylamine (MPPA) as an internal standard showed good linearity (r = 0.999) with 0.36-0.83 ng/mL detection limit at a signal-to-noise ratio of 3. MDMA and MDA in rat whole blood could be monitored for 6 h after a single administration of MDMA (2.2 mg/kg, i.p.). The pharmacokinetic parameters for MDMA and MDA obtained by triplicate measurements were 426 +/- 23 and 39 +/- 6 ng/mL (C(max)), 20 +/- 5 and 100 +/- 10 min (T(max)), respectively.

3,4-Methylenedioxyamphetamine↗

An improved high-throughput liquid chromatographic/tandem mass spectrometric method for terbinafine quantification in human plasma, using automated liquid-liquid extraction based on 96-well format plates.

A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for terbinafine quantification in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 2.2 mL 96-deepwell plates. Terbinafine and the internal standard (IS) N-methyl-1-naphthalenemethylamine were extracted from human plasma by LLE, using a mixture of methyl t-butyl ether (MTBE)-hexane (70:30, v/v) as the organic solvent. All liquid transfer steps, including preparation of calibration standards and quality control samples, as well as the addition of the IS, were performed automatically by using robotic liquid handling workstations. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of a reconstitution solution. Sample analysis was performed by reversed-phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The method had a very short sample preparation time and a chromatographic run time of 2.2 min. It was proved to have excellent sensitivity, specificity, accuracy as well as inter- and intraday precision for the quantification of terbinafine in human plasma. The calibration curve was linear for the range of concentrations 5.0-2000.0 ng/mL. The proposed method was applied to the rapid and reliable determination of terbinafine in a bioequivalence study after per os administration of 250 mg tablet formulations of terbinafine.

Automation↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗

Liquid chromatography-mass spectrometry method for the determination of venlafaxine in human plasma and application to a pharmacokinetic study.

A sensitive and selective liquid chromatographic-mass spectrometric (LC-MS) method for the determination of venlafaxine in human plasma has been developed. Samples were prepared using liquid-liquid extraction and analyzed on a C(18) column interfaced with a triple quadrupole mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase was methanol-water containing 10 mmol/L ammonium acetate, pH 7.9 adjusted with aqueous ammonia (80:20, v/v) at the flow rate of 1.0 mL/min. The analyte and internal standard clozapine were both detected by use of selected ion monitoring mode. The method was linear in the concentration range of 1.0-200.0 ng/mL. The lower limit of quantification (LLOQ) was 1.0 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 10.1%. The accuracy determined at three concentrations (5.0, 50.0 and 150.0 ng/mL for venlafaxine) was within +/-10.0% in terms of relative error (RE). The method was successfully applied for the evaluation of pharmacokinetic profiles of venlafaxine capsule in 20 healthy volunteers. The results show AUC, T(max), C(max) and T(1/2) between the testing formulation and reference formulation have no significant difference (p > 0.05). Relative bioavailability was 103.4 +/- 14.1%.

Adolescent↗

Simultaneous determination of lamotrigine, zonisamide, and carbamazepine in human plasma by high-performance liquid chromatography.

A high-performance liquid chromatography assay with ultraviolet detection was developed for the simultaneous determination of the anti-epileptic drugs lamotrigine, carbamazepine and zonisamide in human plasma and serum. Lamotrigine, carbamazepine, zonisamide and the internal standard chloramphenicol were extracted from serum or plasma using liquid-liquid extraction under alkaline conditions into an organic solvent. The method was linear in the range 1-30 microg/mL for lamotrigine, 2-20 microg/mL for carbamazepine, and 1-40 microg/mL for zonisamide. Within- and between-run precision studies demonstrated coefficient of variation <10% at all tested concentrations. Other anti-epileptic medications tested did not interfere with the assay. The method is appropriate for determining lamotrigine, carbamazepine and zonisamide serum or plasma concentrations for therapeutic monitoring.

Adult↗

A liquid chromatography-mass spectrometry assay method for simultaneous determination of amiodarone and desethylamiodarone in rat specimens.

A liquid chromatographic-mass spectrometry (LC/MS) assay method was developed for the determination of amiodarone and desethylamiodarone in rat specimens. Analytes were extracted using liquid-liquid extraction in hexane. The LC/MS system consisted of a Waters Micromass ZQtrade mark 4000 spectrometer with an autosampler and pump. A C(18) 3.5 microm (2.1 x 50 mm) column heated to 45 degrees C was used for separation. The mobile phase consisted of methanol and 0.2% aqueous formic acid pumped at 0.2 mL/min as a linear gradient. Components eluted within 12 min. The concentrations of ethopropazine (internal standard), desethylamiodarone and amiodarone were monitored for m/z of 313.10, combination of 546.9 and 617.73, and 645.83, respectively. In plasma (0.1 mL), linearity was achieved between the peak area ratios and concentrations over the range of 2.5-1000 ng/mL for both amiodarone and desethylamiodarone (r(2) > 0.999). The intraday and interday CV were equal or less than 18%, and mean error was <12%. Similarly, in homogenates containing 0.1 g of rat tissue, linearity was observed in standards ranging from 5 to 5000 ng/g. The method was successfully used to measure tissue and plasma concentrations of drug. The validated lower limit of quantitation was 2.5 ng/mL for drug and metabolite, based on 0.1 mL of plasma.

Amiodarone↗

Development and validation of an RP-HPLC-UV method for the determination of BOL-303225-A, a new coumarin-based anti-inflammatory drug, in rat plasma.

A simple and rapid high-performance liquid chromatographic method was developed and validated for the analysis in rat plasma of BOL-303225-A, a new coumarin-based anti-inflammatory drug. Liquid-liquid extraction was used for sample preparation. Chromatographic separation was achieved on a C(18) column using acetonitrile and water containing 1% triethylamine pH 3.5, adjusted with orthophosphoric acid (35.5:64.5 v/v) as mobile phase. The UV detector was set at 324 nm. The method proved to be linear (r(2) > 0.99) and precise (RSD < 7%) over the concentration range 29-940 ng/mL, and was suitable for the support of pharmacokinetic studies in rats.

Animals↗

Determination of paclitaxel in human and rat blood samples after administration of low dose paclitaxel by HPLC-UV detection.

A simple and sensitive HPLC-UV method was developed for the determination of paclitaxel (TXL) in human and rat blood samples. 4-Hydroxybenzoic acid n-hexyl ester was used as an internal standard. TXL was extracted by a liquid-liquid extraction with tert-butylmethyl ether. The disturbing peaks in the case of serum sample were removed by pre-extraction with hexane. The separation of TXL was achieved within 25 min using an ODS column with 50% acetonitrile aqueous solution as a mobile phase at a flow rate of 1.0 mL/min. The eluent was monitored at 230 nm, and the resulted retention times of TXL and IS were 11.2 and 20.4 min. The detection limits of TXL for human plasma, serum and rat plasma samples at a signal-to-noise ratio of 3 were 10, 9.5 and 7.5 ng/mL, respectively. The proposed methods were applicable to the determination of TXL in human patients' plasma ranging from 15 to 27 ng/mL. Furthermore, monitoring of the time course of TXL after its single administration to rat could be demonstrated.

Aged↗

Optimization of the quantitative analysis of the major cannabis metabolite (11-nor-9-COOH-delta 9-tetrahydrocannabinol) in urine by gas chromatography/mass spectrometry.

A gas chromatographic/mass spectrometric electron impact method is presented for the detection and quantification of 11-nor-9-carboxy-delta 9-tetrahydrocannabinol (THC-COOH) in urine, for use in the confirmation of presumptive results obtained by other techniques. Four extraction procedures, two solid-liquid and two liquid-liquid, have been compared. A comparison of two trimethylsilylating methods demonstrates that the best results are obtained by the use of a mixture containing N-methyl-N-trimethylsilyl-trifluoroacetamide, trimethyliodosilane and dithioerithritol (100:0.2:1) v/v/w. The use of ketoprofen as a new internal standard for the quantification of THC-COOH has proved to be very effective. Both spiked samples and samples from cannabis users have been successfully analysed. It has also been demonstrated that the presence of other drugs of abuse in urine samples do not interfere with cannabis quantification by the method reported here.

Dronabinol↗