[Case of sarcoma of the knee joint capsule].
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Since opinions about the presence of a band structure or a ligament in the lateral part of the temporomandibular joint capsule are divergent in the literature, the capsule of 16 post-mortem human specimens was examined both anatomically and histologically. A distinguishable ligamentous formation in the lateral part of the capsule was observed only in three specimens. In one of these, the distinguishable formation had morphological characteristics of tendinous tissue. This study indicates caution with too generalised opinions about temporomandibular morphology.
Cervical facet joints are implicated as a major source of pain after whiplash injury. The purpose of this study was to investigate the proposed capsule strain injury mechanism of whiplash pain using neurophysiologic methods. Strain thresholds, threshold distribution, saturation strains and afterdischarge responses of capsule neural receptors were characterized in vivo. Goat C5-C6 facet joint capsules were used to identify and characterize capsule receptors in response to controlled uniaxial stretch by recording C6 dorsal rootlet nerve discharge. The joints were stretched at 0.5 mm/sec in a series of tests with 2 mm increments until the capsule ruptured. Ninety-two identified units were responsive to physiologic or noxious stretch while 28 were silent receptors. Among the 50 characterized responsive units, 42 showed low strain thresholds at 10.2+/-4.6% while 8 had high strain thresholds at 47.2+/-9.6%. Further, 35 of the 42 low-threshold units displayed discharge saturation at various strains (44.2+/-16.7%). A significant finding was that twelve low-threshold units exhibited afterdischarge for greater than 30 sec after stretch release at 36.6+/-12.5% strains, and displayed longer-lasting afterdischarge (greater than 4 min) at higher strains (39.0+/-14.4%) with significant difference (p = 0.019) in strains. Two high-threshold units had afterdischarges for greater than 30 sec or 4 min at 50.3+/-5.9% and 57.7+/-10.6% strains, respectively. In addition, the spatial distribution of the 42 low-threshold receptors demonstrated that the receptors on the joint gap were more strain-sensitive, with significantly lower strain thresholds compared to the rostral and caudal regions. No significant difference in strain threshold was observed in the medial-lateral direction. When compared to the reported strains that facet joint capsules experienced in whiplash (35-60%) and the reported capsule subfailure strains (35-67%), the low strain thresholds are substantially lower whereas the high thresholds and afterdischarge strains are within that range. Thus, low threshold units appear to signal proprioception within the physiologic range. High threshold units likely signal nociception (pain sensation) while afterdischarge may signal capsule strain injury and contribute to persistent pain.
OBJECTIVE: The objective of this study was to determine of the efficiency of holmium:YAG laser for bone ablation, compared to cartilage and soft tissue of the intervertebral foramen of the lumbosacral spine. BACKGROUND DATA: The holmium:YAG (Ho:YAG) laser has been used for ablation of bulging or prolapsed discs and also has the potential for decompression of the nerve root when there is narrowing of the foraminae (foraminoplasty). It is proposed that laser ablation of bone and ligament of the intervertebral foramen for nerve root decompression using the Ho:YAG laser is able to produce sufficient bone ablation without inducing significant thermal necrosis in surrounding tissues due to its short absorption length, which could result in significant clinical advantages. MATERIALS AND METHODS: Experiments were performed on samples of laminar bone, facet joint capsule, and cartilage for quantitative and qualitative determination of the effect of Ho:YAG ablation on tissue mass loss using a range of pulse energies from 0.5 to 1.5 J/P at 15 pulses/sec. RESULTS: The results showed a significant linear correlation between the mass loss and pulse energy, and between the mass loss and radiant exposure. Electron microscopy and histology showed that the Ho:YAG ablation resulted in a very sharp and clear border with little charring. Applying 0.01 k.J of total energy at two different settings (1.5 J/p, high power, and 0.5 J/p, low power) at 15 pulses/sec, the cross-sectional area/mm(2) of the ablated bone was measured, using light microscopy and the Scion Image analysis program. The ablated areas were 2.28 +/- 0.87 and 1.16 +/- 0.43 mm(2) at high and low power, respectively (p = 0.008).
Explore the source record for details and available documents.
This is a report on the results of the lateral splitting of the knee-joint capsule for treatment of chondropathia patellae. The operative procedure is described. Pains relative to the patella syndrome, chondropathia patellae, forms of dysplasia of the patella and lateral dislocation of the patella are regarded as indications. 50 knee-joints were post-examined. 26% were without complaints, 54% showed improvement, 10% no change, 10% deteriorated. These results are comparable to those of other, more intensive surgery. Representing a comparatively minor operation, the lateral splitting of the capsule is therefore particularly recommended for young patients.
Afferent group III and IV nerve fibers of the knee joint markedly differ in their responsiveness to mechanical stimulation, which may be reflected in the structure and location of their terminals. Therefore, in sympathectomized cats, the fine afferent innervation of the knee joint capsule was studied via ultrastructural three-dimensional reconstructions over distances of up to 300 microns. Small peripheral nerves and "free" (noncorpuscular) sensory nerve endings were found in a superficial layer of the outer fibrous part of the capsule, in the patellar retinaculum, and in the outer and inner surface layers of the medial collateral and patellar ligaments. Group III nerve fibers showed a proximal myelinated portion inside the nerve, an intermediate portion that lacks a myelin sheath and is only surrounded by perineurium, and a distal portion outside of the perineurium that forms the sensory ending proper. Group IV fibers showed only two distinct portions, an intraperineurial (proximal) and an extraperineurial (distal) portion without any further morphological differences. Outside of the perineurium, a network formed by Schwann cells ("Schwann cell reticulum") provides a pathway for the distal portion of the sensory axons. No distinct subgroups of the sensory terminal fibers could be defined according to the configuration of the Schwann cells and the nerve fiber terminals. Sensory terminals were located adjacent to different structures such as venous and lymphatic vessels, fat cells, and collagenous fibers. Distinct parts of the same terminal nerve fiber were found in close contact to a vessel wall; others were surrounded by dense collagenous tissue. Close to sensory endings, mast cells and mast cell-like cells were frequently found, indicating a functional relationship.
Explore the source record for details and available documents.
A method has been developed whereby the discharge of mechanically sensitive neurons from the cat knee joint capsule can be calibrated and used as load cells. The neurons are located in the upper edge of the capsule which has been previously modeled as a suspension cable and where the loading has been shown to be one dimensional. The calibration procedure relies upon applying known point loads to the cable and measuring its shape. The biomechanical model is then used to compute the cable tension at the neuron location. Results for 20 neurons showed a strong linear relationship between the tension and the frequency of neuronal discharge (r = 0.96, S.D. = 0.05). For 11 of these neurons the in vivo calibration was verified by subsequently excising the posterior capsule and recording from the same neuron while subjecting the cable to measured uniaxial loads. Results showed good agreement between the in vivo and in vitro calibrations. Once calibrated these neurons can be used as load sensors to study in vivo joint loading.
Explore the source record for details and available documents.
1. Experiments were conducted to test the hypothesis that the responses of joint capsule mechanoreceptors better encode tissue stress or tissue strain. The experimental model was a small ligament from the cat knee capsule, which was stretched uniaxially in vitro. Experiments were done with either force or displacement as the controlled variable, and with steps, sinusoids, or pseudorandom Gaussian noise (PGN) as the input function. 2. The strength of coupling between neural discharge and both strain and stress was quantified during step experiments using linear correlation coefficients. The correlation between the frequency of neural discharge and stress was 0.93 +/- 0.09 (SD). The correlation between frequency of neural discharge and strain was -0.91 +/- 0.06. The magnitudes of these correlation coefficients were not significantly different. 3. The strength of coupling between neural discharge and both strain and stress during sinusoidal and PGN experiments was quantified by the use of an information theoretic statistic, transinformation. Out of 282 sinusoidal runs, transinformation between neural discharge and stress was significantly greater than transinformation between strain and neural discharge 241 times. Transinformation between strain and neural discharge was significantly greater 15 times. 4. During PGN experiments, transinformation between stress and neural discharge was greater than transinformation between strain and neural discharge in all 19 experimental runs. 5. Conditional transinformation between strain and neural discharge, given stress, was calculated for all sinusoidal and pseudorandom experiments. This statistic was greater than zero in 268 out of 289 experimental runs, indicating that a component of strain independent of stress is being signaled in the neural discharge.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The activity of plasminogen activators and plasmin inhibitors in articular capsules of the hip and knee joints in rheumatoid arthritis, chronic traumatic inflammation, arthrosis and aseptic loosening of prosthesis was determined histochemically and correlated with the degree of mobility in osteoarthrosis of the hip. Microscopically unchanged articular capsules were employed as reference sites. In inflammatory articular diseases the plasminogen activator activity was significantly reduced, whereas it remained unchanged in arthrosis and necrosis of the heas of the femur, and significantly enhanced in aseptic loosening of prosthesis. Plasmin inhibitor activity was established in joint capsules with inflammatory changes only; in case of rheumatic inflammation, it was higher than with traumatic inflammation. In osteoarthrosis of the hip there is a positive correlation between joint mobility and plasminogen activator activity. The results point towards involvement of the local fibrinolytic system in joint diseases; however, no definite statement can be made with regard to possible causative linkups.
The noncorpuscular endings ("free nerve endings") of thinly myelinated group III and nonmyelinated group IV afferent nerve fibers have been examined in the knee joint capsule of sympathectomized cats by transmission electron microscopy and three-dimensional reconstruction of series of semi- and ultrathin sections. The sensory ending is the most distal part of a group III or IV nerve fiber that consists only of the sensory axon and associated Schwann cells but lacks a myelin sheath and is not surrounded by perineurium. The sensory axon divides into several branches and forms a terminal tree. The branches run either as single fibers or within small Remak bundles in parallel to sensory axons of other endings; they spread along vessel walls and also extend into dense connective tissue. Each sensory axon consists of a series of spindle-shaped thick segments ("beads") connected by waist-like thin segments. Thus all axons of sensory endings have a string-of-beads appearance, which resembles that of efferent sympathetic nerve fibers. The beads of the sensory axon and the end bulb at its tip show the same ultrastructural features which are characteristic of receptive sites: an accumulation of mitochondria and glycogen particles and various vesicles in the axoplasm and "bare" areas of axolemma that are not covered by Schwann cell processes. Group III and group IV sensory endings differ in the length of their branches (up to 200 microM in group III vs. more than 300 microM in group IV), number of beads per 100 microM axon length (about seven vs. nine or ten), mean diameter of axons (0.9-1.5 microM vs. 0.3-0.6 microM), and the presence of a neurofilament core consisting of bundles of parallel microfilaments only in group III. In conclusion, we propose that the sensory part of noncorpuscular "free nerve endings" is formed by the entire terminal tree of group III or group IV nerve fibers and that the beads in the course of the sensory axon represent multiple receptive sites.
PURPOSE: Lumbar spinal manipulation (SM) is a popular, effective treatment for low back pain but the physiological mechanisms remain elusive. During SM, mechanoreceptors innervating the facet joint capsule (FJC) may receive a novel stimulus, contributing to the neurophysiological benefits of SM. The biomechanics of SM and physiological axial rotations were compared to determine whether speed or loading site affected FJC strain magnitudes or patterns. METHODS: Human lumbar spine specimens were tested during physiological rotations and simulated SM while measuring applied torque, vertebral motion, and FJC strain. During physiological rotations, specimens were actuated at T12 to 20 degrees left and right axial rotation at 2 degrees to 125 degrees per second. During SM simulations, a 7-mm impulse displacement was applied to L3, L4, or L5 at 5 to 50 mm per second. RESULTS: Physiological rotations. Increasing displacement rate resulted in significantly larger torque magnitudes (P < .001), whereas vertebral kinematics and FJC strain magnitudes were unchanged (P > .05). Physiological rotations vs SM. Applied torque and vertebral rotation magnitudes were similar across speed and vertebral level. Total vertebral translations were slightly larger during physiological rotations vs SM at a given loading rate (P < .05). Patterns of vertebral motions and FJC strain during SM and physiological rotations varied significantly with loading rate (P < .05) but not with actuation site (P > .15). CONCLUSIONS: The similar patterns observed in vertebral motion and FJC strain across actuation sites during SM and physiological rotations suggest that site specificity of SM may have minimal clinical relevance. High loading rates during lumbar SM resulted in unique patterns in FJC strain, which may result in unique patterns of FJC mechanoreceptor response.