Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “IONS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Rare earth ions block the ion pores generated by the class II fusion proteins of alphaviruses and allow analysis of the biological functions of these pores.

Recently, class II fusion proteins have been identified on the surface of alpha- and flaviviruses. These proteins have two functions besides membrane fusion: they generate an isometric lattice on the viral surface and they form ion-permeable pores at low pH. An attempt was made to identify inhibitors for the ion pores generated by the fusion proteins of the alphaviruses Semliki Forest virus and Sindbis virus. These pores can be detected and analysed in three situations: (i) in the target membrane during virus entry, by performing patch-clamp measurements of membrane currents; (ii) in the virus particle, by studying the entry of propidium iodide; and (iii) in the plasma membrane of infected cells, by Fura-2 fluorescence imaging of Ca2+ entry into infected cells. It is shown here that, at a concentration of 0.1 mM, rare earth ions block the ion permeability of alphavirus ion pores in all three situations. Even at a concentration of 0.5 mM, these ions do not block formation of the viral fusion pore, as they do not inhibit entry or multiplication of alphaviruses. The data indicate that ions flow through the ion pores into the virus particle in the endosome and from the endosome into the cytoplasm after fusion of the viral envelope with the endosomal membrane. These ion flows, however, are not necessary for productive infection. The possibility that the ability of class II fusion proteins to form ion-permeable pores reflects their origin from protein toxins that form ion-permeable pores, and that entry via class II fusion proteins may resemble the entry of non-enveloped viruses, is discussed.

Alphavirus↗

Judgement on "hit or non-hit" of CHO cells exposed to accelerated heavy-ions (Fe- or Ar-ions) using division delay and CR-39 plastics as an indicator.

The cell killing effect of ionizing radiation depends on the degree of linear energy transfer (LET). The relative biological effectiveness (RBE) reaches a maximum at LET of around 100-200 keV/micron and decreases at higher levels. The ion clusters produced by high-LET radiation are not uniformly distributed. The incidence of non-hit cell events is higher in high LET irradiation than in the cases of low-LET irradiation. This fact could explain the decrease in the cell killing effect at higher levels of LET irradiation. Since the cell killing effect may be related to the nuclear traversal of heavy-ions, it is necessary to establish methods to distinguish the hit cells from the non-hit cells, especially in case with high LET irradiation. Using time-lapse photography, we first examined the hit events by observing the division delay in the cells caused by high-LET irradiation. In addition, we explored the use of CR-39 plastics to detect the exact position of heavy-ion traversal on the surface of a flask where cells were growing. When Chinese hamster ovary (CHO-K1) cells were exposed to 4 Gy of accelerated Fe-ions (2000 keV/micron) or Ar (1640 keV/micron)-ions, the surviving fraction decreased to about 30% in both cases of irradiation. Eighty percent of the irradiated cells, suffered a division delay in contrast to the remaining 20% of the cells which showed a normal division time (12-13 hrs). The later 20% of the cells is considered to be a population of cells which were not actually traversed by heavy-ions. The difference between the higher values of the surviving fraction (approximately 30%) and the non-hit cell population (20%) indicates that some hit cells can grow even after being hit by heavy-ions. The fraction of recovered cells determined by the time-lapse photography method was 10%, and this value closely correlated with the difference between the surviving fraction and the non-hit cells. We used the Poisson distribution of the hit-events by heavy-ions among the cell population in order to calculate the fraction of cells receiving at least a single-hit in the cell nucleus (130 micron 2 in average size). From this calculation we determined that 80% of the cells had a single hit to their nuclei by a heavy-ion which induced such early cellular responses as division delay. Our finding in the experiments using CR-39 plastics as a detector for hit-sites further supported the idea that the hit lethality of a cell is related to heavy-ion traversal through its nucleus. This study indicates the possible usefulness of both the division delay and CR-39 plastic methods for evaluating the biological effects of heavy-ions, especially when these two methods are combined.

Animals↗

Adsorption of fluoride, phosphate, and arsenate ions on a new type of ion exchange fiber.

A new type of ion exchange fiber for the removal of fluoride, phosphate, and arsenate ions has been developed. A batch adsorption technique for investigating adsorption kinetic and equilibrium parameters and determining pH adsorption edges is applied. It is shown that the adsorption properties of the ion exchange fiber for fluoride, phosphate, and arsenate ions depend on the pH value and anion concentration. The adsorption of arsenate on the sorbent reaches a maximum of 97.9% in the pH value range of 3.5 to 7.0. The adsorption percentage of phosphate is more than 99% in the pH range of 3.0 to 5.5. The adsorption of fluoride on the ion exchange fiber is found to be 90.4% at pH 3.0. The Freundlich model can describe the adsorption equilibrium data of fluoride, arsenate, and phosphate anions. The sorption of the three anions on the ion exchange fiber is a rapid process, and the adsorption kinetic data can be simulated very well by the pseudo-second-order rate equation. The column performance is carried out to assess the applicability of the ion exchange fiber for the removal of fluoride, phosphate, and arsenate ions from synthetic wastewaters with satisfactory removal efficiency. The desorption experiment shows that fluoride ion sorbed by the fiber column can be quantitatively desorbed with 5 mL of 0.50 mol/L NaOH at elution rate of 1 mL/min, and 30 mL of NaOH is necessary for the quantitative recovery of phosphate and arsenate ions.

Acrylic Resins↗

Mechanism of ion permeation in a model channel: Free energy surface and dynamics of K+ ion transport in an anion-doped carbon nanotube.

The mechanism of the ion permeation is investigated for an anion-doped carbon nanotube, as a model of the K+ channel, by analyzing the free energy surface and the dynamics of the ion permeation through the model channel. It is found that the main rate-determining step is how an ion enters the channel. The entrance of the ion is mostly blocked by a water molecule located at this entrance. Only about 10% of K+ ions which reach the mouth of the channel can really enter the channel. The rejection rate sensitively depends on the location of this water molecule, which is easily controlled by the charge of the carbon nanotube; for example, the maximum permeation is obtained when the anion charge is at a certain value, -5.4e in the present model. At this charge, the facile translocation of the ion inside the channel is also induced due to the number of fluctuations of the ions inside the channel. Therefore, the so-called "Newton's balls", a toy model, combined with a simple ion diffusion model for explaining the fast ion permeation should be modified. The present analysis thus suggests that there exists an optimum combination of the length and the charge of the carbon nanotube for the most efficient ion permeation.

Anions↗

Quadrupole ion trap studies of the structure and reactivity of transition metal ion pair complexes

Ion pairs are common species observed in the electrospray mass spectra of transition metal coordination complexes. To understand the nature of these ion pairs, a systematic study of the gas-phase chemistry of these species using ion-molecule reactions and collision-induced dissociation (CID) was carried out. Ion pair complexes of the type MLnX+ (where M is Mn(II), Fe(II), Co(II), Ni(II), Cu(II) or Zn(II), L is 1,10-phenanthroline, 2,2'-bipyridine, ethylenediamine, diethylenetriamine or 1,4,8,11-tetraazacyclotetradecane and X is Cl-, NO3-, acetylacetonate, ClO4-, acetate or SCN-) were studied. Ion-molecule reactions can distinguish whether the counterion in an ion pair is an inner- or outer-sphere ligand and can determine the coordination mode of the counterion. In addition, CID and ion-molecule reactions reveal some interesting chemistry of these complexes and unique coordination modes for some of the anions studied here were inferred from the ion-molecule reactions. For example, the thiocyanate ion is found to coordinate in a bidentate fashion in Zn(II) and Ni(II) complexes, contrasting behavior typically observed in solution. Also, certain Co(II) and Fe(II) ion pair complexes undergo oxidation reactions in which species such as dioxygen and nitric oxide from the counterions ClO4- and NO3- are transferred to the Co(II) and Fe(II) complexes, showing the inherent affinity of these metals for these molecules. These complexes were also studied by ion-molecule reactions and CID. Dioxygen in complexes formed by CID is demonstrated to be bidentate, suggesting the formation of a peroxo ligand with concurrent oxidation of the metal.

Journal Article↗

Cluster ions derived from sodium and potassium tetrafluoroborate and their collision induced dissociation in an ion trap mass spectrometer.

Electrospray ionization was used to produce distributions of gas-phase cluster ions from solutions of sodium and potassium tetrafluoroborate. The majority of the cluster species followed the trend (MBF(4))(n)M(+), where M=Na and K. The values of n, for both salts, ranged from 1-15. Collision induced dissociation (MS/MS and MS(n)) in an ion trap mass spectrometer was used to determine the dissociation pathways for the cluster ions. The (NaBF(4))(n)Na(+) cluster ions fragmented via two pathways: (a) the loss of one or multiple neutral BF(3) molecules and (b) the loss of one or more NaBF(4) units. Of the two, the product ions corresponding to the loss of BF(3) units were more prominent. Unlike the Na salt, the (KBF(4))(n)K(+) cluster ions decomposed primarily by the loss of one or multiple KBF(4) units. Similar differences in dissociation behavior were observed when the heated transfer capillary, normally used to desolvate ions, was used to investigate cluster ion stability to thermal degradation and dissociation. The dissociation profiles (decrease in ion abundance with increasing activation amplitude) for several (NaF)(n)Na(+) and (KF)(n)K(+) cluster ions were measured and compared to probe the influence of the relative stability of the alkali fluorides (NaF and KF) on the dissociation behavior exhibited by the tetrafluoroborate cluster distributions. We found that the (NaF)(n)Na(+) cluster ions required higher activation amplitudes to induce fragmentation than the corresponding (KF)(n)K(+) species, indicative of stronger ionic bonding and higher gas-phase stability for the former. This in turn indicates that the reaction pathway involving only the loss of one or multiple units of BF(3), favored for the (NaBF(4))(n)Na(+) cluster series, but not for the analogous (KBF(4))(n)K(+) series, may be due to the high gas-phase stability of NaF, and relatively lower stability of KF, towards dissociation.

Journal Article↗

Analysis of glycoalkaloids from potato shoots and tomatoes by four-sector tandem mass spectrometry with scanning-array detection: comparison of positive ion and negative ion methods.

A wide range of glycoalkaloids from potato shoots and tomatoes, including trisaccharide-containing glycoalkaloids (alpha-chaconine, alpha-solanine, and alpha-solasonine), tetrasaccharide-containing glycoalkaloids (alpha-tomatine and demissine), and disaccharide-containing glycoalkaloids (beta 1-chaconine, beta 2-chaconine, and beta-solamargine), have been studied by both positive and negative ion liquid secondary ion and four-sector tandem mass spectrometry with scanning-array detection. In positive ion mode, collisionally induced dissociation tandem mass spectra of the [M + H]+ ions induce three major fragmentation processes, Z cleavage, Y cleavage, and 1,5X cleavage, which are structurally informative. Signals resulting from Z0, Y0, and 1,5X0 cleavages provide information on the nature of various aglycone moieties in all glycoalkaloids. Linkages and positions of the sugars in trisaccharide- and tetrasaccharide-containing glycoalkaloids are indicated by the presence or absence of the ions corresponding to Z alpha/beta and Y alpha/beta cleavages and intensity differences of the peaks due to 1,5X alpha and 1,5X beta cleavages, respectively. In negative ion mode, collisionally induced dissociation tandem mass spectra of the [M - H]- ions induce Y cleavage as the major fragmentation process. The location of the terminal sugars in branched trisaccharide and tetrasaccharide glycoalkaloids is indicated by the difference in intensity of the ions due to Y alpha cleavage and Y beta cleavage. Isomeric structures cannot, however, be differentiated unambiguously; complete structural assignment is only possible by NMR of purified components. Both positive and negative ion tandem mass spectrometry are considered to be suitable for the characterisation of glycoalkaloids in mixtures. The positive ion method has the advantage of (i) a lower detection limit than in conventional mass spectrometry; (ii) numerous and intense fragment ions which are structurally informative; and (iii) the capability of analyzing minor components in crude extracts. Comparable analysis by other analytical means would not have provided the amount of structural information on the components in the glycoalkaloid mixtures.

Alkaloids↗

The binding of terbium ions to gelsolin reveals two classes of metal ion binding sites.

Spectroscopically active terbium ions have been used to probe the Ca2+ ion-binding sites on human plasma gelsolin. The luminescence of Tb3+ ions bound to gelsolin is markedly enhanced when excited indirectly at 295 nm due to Förster type dipole-dipole energy transfer from neighboring tryptophan residues. Titration of this luminescence with increasing concentrations of Tb3+ ions was saturable although the shape of this titration curve was complex indicating the involvement of multiple classes of sites. Luminescence lifetime measurements (obtained by indirect excitation at 295 nm) demonstrate the presence of two classes of sites characterized by a major lifetime of 1.0-1.1 ms and a minor lifetime of 0.7-0.8 ms. However, while the amplitude of the minor lifetime showed a hyperbolic dependence on the Tb3+ ion concentration, the amplitude of the major lifetime showed a strongly sigmoidal dependence. Different classes of Tb3+ ion binding sites can also be distinguished by the different Ca2+ ion concentrations needed to displace Tb3+ ions from these sites on gelsolin. It is proposed that the occupancy of one class of Tb3+ ion binding sites on gelsolin causes a conformational change in gelsolin which then allows a second class of cryptic Tb3+ ion binding sites to be expressed. The implications of these results in terms of the binding of Ca2+ ions to gelsolin and the regulation of the activities of gelsolin by calcium are discussed.

Binding Sites↗

Ion pair binding of Ca2+ and Cl- ions in micellar-packaged gramicidin A.

The two independent NMR experiments were performed to investigate the interaction between CaCl2 and the gramicidin A (GA) ion transport channel, using 13C-enriched GA and GA molecules incorporated into dodecylphosphocholine (DPC) micelles. The chemical shifts of C-13 labeled carbonyl carbons vs. CaCl2 concentration demonstrate that Ca2+ and Cl- ions interact as an ion pair within the GA structure with the Cl- ion located near the position of the carbonyl group of the Trp11 residue some 5.5 A from the mouth of the GA helix, and the Ca2+ ion bound at the position of the carbonyl group of the Trp15 residue some 2.5 A from the entrance to the helical pore. The measurements of the 35Cl line-widths and transverse relaxation times illustrate that the interaction occurs between Cl- ions and GA in DPC when in CaCl2 solution, that no interaction is detected between Cl- ions and GA in DPC when in NaCl solution, and that the interaction between Cl- ions and GA in DPC when in MgCl2 solution is much weaker than in CaCl2 solution. In short, a Cl- ion can enter the GA when it is paired with a divalent Ca2+ ion; and Ca2+ and Cl- ions as a pair exchange rapidly with sites of the GA dimer.

Amino Acid Sequence↗

Ions generated from uranyl nitrate solutions by electrospray ionization (ESI) and detected with Fourier transform ion-cyclotron resonance (FT-ICR) mass spectrometry.

Electrospray ionization (ESI) of uranyl nitrate solutions generates a wide variety of positively and negatively charged ions, including complex adducts of uranyl ions with methoxy, hydroxy, and nitrate ligands. In the positive ion mode, ions detected by Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry are sensitive to instrumental tuning parameters such as quadrupole operating frequency and trapping time. Positive ions correspond to oligomeric uranyl nitrate species that can be characterized as having a general formula of [(UO(2))(n)(A)(m)(CH(3)OH)(s)](+) or [(UO(2))(n)(O)(A)(m)(CH(3)OH)(s)](+) with n = 1-4, m = 1-7, s = 0 or 1, and A = OH, NO(3), CH(3)O or a combination of these, although the formation of NO(3)-containing species is preferred. In the negative ion mode, complexes of the form [(UO(2))(NO(3))(m)](-) (m = 1-3) are detected, although the formation of the oxo-containing ions [(UO(2))(O)(n)(NO(3))(m)](-) (n = 1-2, m = 1-2) and the hydroxy-containing ions [(UO(2))(OH)(n)(NO(3))(m)](-) (n = 1-2, m = 0-1) are also observed. The extent of coordinative unsaturation of both positive and negative ions can be determined by ligand association/exchange and H/D exchange experiments using D(2)O and CD(3)OD as neutral reaction partners in the gas-phase. Positive ions are of varying stability and reactivity and may fragment extensively upon collision with D(2)O, CD(3)OD and N(2) in sustained off-resonance irradiation/collision-induced dissociation (SORI-CID) experiments. Electron-transfer reactions, presumably occurring during electrospray ionization but also in SORI-CID, can result in reduction of U(VI) to U(V) and perhaps even U(IV).

Calibration↗

A new surface structural approach to ion adsorption: tracing the location of electrolyte ions.

Electrolyte ions differ in size leading to the possibility that the distance of closest approach to a charged surface differs for different ions. So far, ions bound as outersphere complexes have been treated as point charges present at one or two electrostatic plane(s). However, in a multicomponent system, each electrolyte ion may have its own distance of approach and corresponding electrostatic plane with an ion-specific capacitance. It is preferable to make the capacitance of the compact part of the double layer a general characteristic of the solid-solution interface. A new surface structural approach is presented that may account for variation in size of electrolyte ions. In this approach, the location of the charge of the outersphere surface complexes is described using the concept of charge distribution in which the ion charge is allowed to be distributed over two electrostatic planes. It was shown that the concept can successfully describe the pH dependent proton binding and the shift in the isoelectric point (IEP) in the presence of variety of monovalent electrolyte ions, including Li(+), Na(+), K(+), Cs(+), Cl(-), NO(-)(3), and ClO(-)(4) with a common set of parameters. The new concept also sheds more light on the degree of hydration of the ions when present as outersphere complexes. Interpretation of the charge distribution values obtained shows that Cl(-) ions are located relatively close to the surface. The large alkali ions K(+), Cs(+), and Rb(+) are at the largest distance. Li(+), Na(+), NO(-)(3), and ClO(-)(4) are present at intermediate positions.

Journal Article↗

Electrophoretic mobility study on ion-ion interactions in an aqueous solution.

Ion-ion interactions between anions and their pairing ions in aqueous solutions were studied through the measurements of electrophoretic mobilities of analyte ions in capillary zone electrophoresis, where the electrophoretic method for the analysis of ion association reaction is shown to be more useful than the conductometric method widely used in the analysis of the reactions. The electrophoretic mobility of monovalent inorganic anions was almost identical even when the concentrations of alkali metal ions and quaternary ammonium ions in the migrating solution were varied up to 15 mM. On the other hand, the electrophoretic mobility of organic anions, such as monovalent and divalent anions, decreased with increasing concentrations of quaternary ammonium ions. Changes in the electrophoretic mobilities were analyzed by a non-linear least-squares method giving ion association constants. The results indicate that the proposed method is applicable to the analysis of such reactions to give the mobility change. The ion association constants obtained in an aqueous solution were related to the extraction constants of the ion associates, and the contributions of the association process and the distribution process were clarified.

Acids↗

Copper ions differ from other thiol reactive metal ions in their effects on the concentration and redox status of thiols in HeLa cell cultures.

Ions of metals such as copper, mercury, silver and cadmium are known to exhibit a high affinity for thiol groups and may therefore severely disturb many metabolic functions in the cell. Copper ions are also known to catalyse the formation of toxic oxygen species through a series of redox reactions. In the present study, we have determined the concentration of reduced and total glutathione, cysteine and homocysteine in a cell culture system (HeLa cell line) after addition of these metal ions. The main findings of the metal ion effect on the total thiol concentrations are that all metal ions increased the release of glutathione into the medium. Since the intracellular concentration of glutathione did not decrease under these conditions, the synthesis of glutathione must have been increased. In contrast to the other metal ions, copper ions also increased the release of homocysteine into the medium, possibly through interaction with S-adenosylhomocysteine hydrolase. The main findings of metal ion effects on reduced thiol are that, at concentrations not interfering with cell growth, mercury, silver and cadmium ions increased the concentration of extracellular reduced glutathione, possibly reflecting the increase of total glutathione in the medium. In contrast to the other metal ions, the addition of even very low amounts of copper ions (1 mumol/l) decreased the concentration of intra- and extracellular reduced thiols indicating oxidative stress.

Animals↗

Time-of-flight secondary ion mass spectrometry of matrix-diluted oligo- and polypeptides bombarded with slow and fast projectiles: positive and negative matrix and analyte ion yields, background signals, and sample aging.

Human angiotensin II, chain B of bovine insulin, and porcine insulin were determined by time-of-flight secondary ion mass spectrometry under impact of approximately 25 keV Xe+ and SF5+ ion beams and approximately 100 MeV 252Cf fission fragments. Matrix-embedded samples, dissolved in a large surplus of alpha-cyano-4-hydroxycinnamic acid, were prepared by nebulizer spray deposition, neat samples by the droplet technique. It is shown that the status of the sample can be assessed by evaluating the matrix-specific features of the mass spectra. The beneficial effect of matrix isolation was small for angiotensin but large for the insulin samples, which did not show parent peaks from neat material. Negative ion yields under SF5+ impact were up to a factor of 50 higher than with Xe+. For positive secondary ions, the enhancement was much smaller. The mass spectra produced by slow ion beams or fast fission fragments were qualitatively similar. Quantitative differences include the following: with fast projectiles the yields were about 10-30 times higher than with slow ions, but similar for negative ion emission under SF5+ bombardment; the analyte-to-matrix yield ratios were higher with slow ions and up to 250 times higher than the molar analyte concentration; for analyte ions the peak-to-background ratios were higher using slow projectiles; the fraction of carbon-rich collisionally formed molecular ions was much higher with fast projectiles. Sample aging in vacuum for up to five weeks strongly reduced the yield of protonated analyte molecules ejected by slow ion impact, but not of deprotonated species. Hence protonation seems to correlate with sample "wetness" or the presence of volatile proton-donating additives.

Angiotensins↗

Mass selective axial ion ejection from a linear quadrupole ion trap.

The electric fields responsible for mass-selective axial ejection (MSAE) of ions trapped in a linear quadrupole ion trap have been studied using a combination of analytic theory and computer modeling. Axial ejection occurs as a consequence of the trapped ions' radial motion, which is characterized by extrema that are phase-synchronous with the local RF potential. As a result, the net axial electric field experienced by ions in the fringe region, over one RF cycle, is positive. This axial field depends strongly on both the axial and radial ion coordinates. The superposition of a repulsive potential applied to an exit lens with the diminishing quadrupole potential in the fringing region near the end of a quadrupole rod array can give rise to an approximately conical surface on which the net axial force experienced by an ion, averaged over one RF cycle, is zero. This conical surface has been named the cone of reflection because it divides the regions of ion reflection and ion ejection. Once an ion penetrates this surface, it feels a strong net positive axial force and is accelerated toward the exit lens. As a consequence of the strong dependence of the axial field on radial displacement, trapped thermalized ions can be ejected axially from a linear ion trap in a mass-selective way when their radial amplitude is increased through a resonant response to an auxiliary signal.

Journal Article↗

Charge-state shifting of individual multiply-charged ions of bovine albumin dimer and molecular weight determination using an individual-ion approach.

Ion-molecule reactions of individual multiply-protonated ions of bovine albumin dimer, formed from electrospray ionization, have been studied using a Fourier transform ion cyclotron resonance mass spectrometer. Upon reaction of ammonia with a group of individual ions, charge-state shifting was observed due to proton transfer. Repeated additions of ammonia during remeasurements of the same ion population were observed to induce multiple-step charge-state shifts. Charge-state-dependent reactivity, as well as nonstatistical behavior in reactivity, was observed due to the small ion population. The molecular weights of individual ions whose charge state shifted during reaction were determined with an accuracy of 67 ppm, the first example of using an individual-ion approach to the determination of molecular weight for a large biopolymer. The molecular weight distribution of a group of ions can be determined with a precision related to the number of ions examined and the weight heterogeneity of the sample. We obtained the molecular weight for eight individual ions from which a molecular weight of 133,320 +/- 210 Da was calculated for bovine albumin dimer.

Animals↗

Molecular ion imaging and dynamic secondary ion mass spectrometry of organic compounds.

An ion microscope equipped with a resistive anode encoder imaging system has been used to acquire molecular secondary ion images, with lateral resolution on the order of 1 microns, from several quaternary ammonium salts, an amino acid, and a polynuclear aromatic hydrocarbon which were deposited onto copper transmission electron microscope grids. All images were generated by using the secondary ion signal of the parent molecular species. The variation of parent and fragment molecular ion signals with primary ion dose indicates that, for many bulk organic compounds, bombardment-induced fragmentation of parent molecules saturates at primary ion doses of (1-8) X 10(14) ions/cm2. Subsequent ion impacts cause little further accumulation of damage in the sample, and intact parent molecular ions are sputtered even after prolonged ion bombardment (i.e. primary ion doses greater than 1 X 10(16) ions/cm2). This saturation process allows molecular images to be obtained at high primary ion doses and allows depth profiles to be obtained from simple molecular solid/metal test structures.

Mass Spectrometry↗

Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization Fourier transform ion cyclotron resonance.

When combined with capillary LC separations, electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS) has demonstrated capabilities for advanced characterization of proteomes based upon analyses of proteolytic digests. Incorporation of external (to the ICR cell) multipole devices with FTICR for ion selection and ion accumulation has enhanced the dynamic range, sensitivity, and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in "overfilling" of the external trap during the elution of major peaks and result in m/z discrimination and fragmentation of peptide ions. Excessive space charge trapped in the ICR cell also causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) and making protein identification less effective. To eliminate m/z discrimination in the external ion trap, further increase duty cycle, and improve MMA, we have developed the capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as automated gain control (AGC). This development has been implemented in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The overall system was initially evaluated in the analysis of a tryptic digest of bovine serum albumin. In conjunction with internal calibration, the capillary LC-ESI-AGC-FTICR instrumentation provided a approximately 10-fold increase in the number of identified tryptic peptides compared to that obtained using a fixed ion accumulation time and external calibration methods.

Journal Article↗