Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “High Throughput Screening”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Biophotonic cytotoxicity assay for high-throughput screening of cytolytic killing.

We have developed a highly sensitive biophotonic luciferase assay as an alternative to (51)Cr-release for assessment of cell-mediated cytotoxicity. The luciferin/ATP-dependent luminescent signal of target cells stably or transiently transfected with a firefly luciferase reporter gene (fLuc:Zeo) linearly correlates with viable target cell number. Upon incubation of fLuc:Zeo(+) target cells with CD8(+) CTLs, a rapid decrease in bioluminescence was detected that correlated with antigen-specific target cell lysis. The levels of specific lysis measured by (51)Cr-release assays correlated with the attenuation in biophotonic target cell signal, thus validating this approach as a sensitive and accurate method for the measurement of cytolysis. We show that this luminescent-based cytolytic assay (LCA) is amenable for high-throughput screening of effector cell cytolytic activity, allows for the rate of cytolysis to be measured in a single micro-plate, and permits the multiplexing of cytolytic killing with other lymphocyte functional assays such as cytokine release. Importantly, this method accurately measures the cytolytic killing of target cells that are either stably or transiently transfected with a fLuc reporter gene, and thus is ideal for monitoring cytolysis of both primary autologous and immortalized target cell lines. The versatility of the non-radioactive, high-throughput, biophotonic cytolytic assay should make this method an attractive alternative to chromium-release for quantifying effector cell cytolytic activity.

CD8-Positive T-Lymphocytes↗

[High throughput screening method of potassium channel regulators].

AIM: To discover new regulators of potassium channel, an in vitro assay based on DiBAC4 (3) to determine the fluorescence was established for high throughput screening. METHODS: A cell-based 96-well format fluorescence assay using DiBAC4 (3) in cultured PC12 cells was described. Cells were loaded with 5 mumol.L-1 DiBAC4 (3) and incubated at 37 degrees C for 30 min before adding KCl or several known potassium channel regulators. The cellular DiBAC4 (3) fluorescence responce was then detected. The fluorescence changes can be used to evaluate membrane potential changes, which are determined mainly by potassium channels. RESULTS: Extracellular high K(+)-induced depolarization and several potassium channel blockers including 4-AP, TEA, E-4031, glibenclamide, quinidine and nifedipine all evoked increases in DiBAC4 (3) fluorescence response. The potassium channel opener, cromakalim, evoked decrease in DiBAC4 (3) fluorescence response. The fluorescence changes of 4-AP, TEA, glibenclamide, nifedipine and cromakalim were in a concentration-dependent manner. In 76 compounds screened by using the established DiBAC4 (3)-based assay, 9 compounds were found to change the fluorescence dose-dependently. Patch clamp technique is needed to further testify and screen their actions on potassium currents. CONCLUSION: The DiBAC4 (3)-based assay is easily operated, economical and repeatable. So, it can be performed by high throughput screening for potassium channel regulators.

4-Aminopyridine↗

A yellow fluorescent protein-based assay for high-throughput screening of glycine and GABAA receptor chloride channels.

There is a significant clinical need to identify novel ligands with high selectivity and potency for GABA(A), GABA(C) and glycine receptor Cl- channels. Two recently developed, yellow fluorescent protein variants (YFP-I152L and YFP-V163S) are highly sensitive to quench by small anions and are thus suited to reporting anionic influx into cells. The aim of this study was to establish the optimal conditions for using these constructs for high-throughput screening of GABA(A), GABA(C) and glycine receptors transiently expressed in HEK293 cells. We found that a 70% fluorescence reduction was achieved by quenching YFP-I152L with a 10 s influx of I- ions, driven by an external I- concentration of at least 50 mM. The fluorescence quench was rapid, with a mean time constant of 3 s. These responses were similar for all anion receptor types studied. We also show the assay is sufficiently sensitive to measure agonist and antagonist concentration-responses using either imaging- or photomultiplier-based detection systems. The robustness, sensitivity and low cost of this assay render it suited for high-throughput screening of transiently expressed anionic ligand-gated channels.

Bacterial Proteins↗

Fluorescence assays for high-throughput screening of protein kinases.

Protein kinases comprise one of the most important group of targets for drug discovery research today. Methods to identify novel kinase inhibitors by high-throughput screening have evolved rapidly in recent years. An important aspect is the availability of fluorescent probes that can be applied in a homogeneous, or mix-and-measure, assay format. Here, we illustrate the application of fluorescence read-out technologies for kinase targets in light of our own experiences in assay development and high-throughput screening.

Animals↗

Design and prioritization of plates for high-throughput screening.

A general algorithm for the prioritization and selection of plates for high-throughput screening is presented. The method uses a simulated annealing algorithm to search through the space of plate combinations for the one that maximizes some user-defined objective function. The algorithm is robust and convergent, and permits the simultaneous optimization of multiple design objectives, including molecular diversity, similarity to known actives, predicted activity or binding affinity, and many others. It is shown that the arrangement of compounds among the plates may have important consequences on the ability to design a well-targeted and cost-effective experiment. To that end, two simple and effective schemes for the construction of homogeneous and heterogeneous plates are outlined, using a novel similarity sorting algorithm based on one-dimensional nonlinear mapping.

Algorithms↗

Preclinical drug metabolism in the age of high-throughput screening: an industrial perspective.

With the advent of genomics, combinatorial paradigms and high-throughput screen (HTS)-based pharmacological testing, the number of compounds flowing through the discovery pipeline is likely to escalate. At the same time, with increased knowledge of the human drug-metabolizing enzymes and the availability of in vitro absorption-metabolism (AM) models, Preclinical Drug Metabolism is poised to meet the challenges of HTS. In order to be successful, however, a rational HTS strategy (vs. serendipitous HTS) has to be employed. Such a strategy is based on automation, validation and integration of in vitro AM models and database management (AVID). A generalized strategy for rational (AVID-based) HTS in Preclinical Drug Metabolism is described briefly.

Animals↗

Enrichment of extremely noisy high-throughput screening data using a naïve Bayes classifier.

The noise level of a high-throughput screening (HTS) experiment depends on various factors such as the quality and robustness of the assay itself and the quality of the robotic platform. Screening of compound mixtures is noisier than screening single compounds per well. A classification model based on naïve Bayes (NB) may be used to enrich such data. The authors studied the ability of the NB classifier to prioritize noisy primary HTS data of compound mixtures (5 compounds/well) in 4 campaigns in which the percentage of noise presumed to be inactive compounds ranged between 81% and 91%. The top 10% of the compounds suggested by the classifier captured between 26% and 45% of the active compounds. These results are reasonable and useful, considering the poor quality of the training set and the short computing time that is needed to build and deploy the classifier.

Bayes Theorem↗

Antibody arrays for high-throughput screening of antibody-antigen interactions.

We have developed a novel technique for high-throughput screening of recombinant antibodies, based on the creation of antibody arrays. Our method uses robotic picking and high-density gridding of bacteria containing antibody genes followed by filter-based enzyme-linked immunosorbent assay (ELISA) screening to identify clones that express binding antibody fragments. By eliminating the need for liquid handling, we can thereby screen up to 18,342 different antibody clones at a time and, because the clones are arrayed from master stocks, the same antibodies can be double spotted and screened simultaneously against 15 different antigens. We have used our technique in several different applications, including isolating antibodies against impure proteins and complex antigens, where several rounds of phage display often fail. Our results indicate that antibody arrays can be used to identify differentially expressed proteins.

Amino Acid Sequence↗

High throughput screening of beta-amyloid secretion inhibitors using homogenous time-resolved fluorescence.

A cell-based assay using homogeneous time-resolved fluorescence has been developed for high throughput screening of putative beta-amyloid (Abeta)production inhibitors. In this assay, total Abeta is detected by simply adding two commercially available antibody complexes. The first was a biotinylated monoclonal antibody (4G8), specifically recognizing an epitope comprising the residues 17-24 of the Abetapeptide, complexed with europium cryptate-streptavidin conjugate. The second was a polyclonal antibody (BioS-N), raised against the N-terminus of the Abeta peptide, complexed with an allophycocyanin-anti rabbit antibody conjugate. Binding of the two complexes to the Abeta peptide brought europium cryptate (fluorescence donor) and allophycocyanin (fluorescence acceptor) into close proximity, consequently a fluorescent resonance energy transfer signal was produced upon excitation at 337 nm. The resulting fluorescence signal (665 nm) was then detected using a Discovery or a ViewLux reader. Detection of Abeta by the proposed method is possible at concentrations of approximately 1 nM. The method was employed for the detection of Abeta secreted from a stable transfected human neuroglioma cell line (H4) overexpressing a mutated form of the human amyloid precursor protein (APP695NL) and developed for robotic automation. At optimized conditions, signal-to-background ratios exceeding 5 and Z' factors around 0.7 were achieved in a 384-well format. High throughput screening of 56,913 potential Abeta production inhibitors led to identification of new non-cytotoxic and cell permeable compounds with potencies in the submicromolar range.

Amyloid beta-Peptides↗

A versatile high-throughput screen for inhibitors of lipid kinase activity: development of an immobilized phospholipid plate assay for phosphoinositide 3-kinase gamma.

The family of phosphoinositide 3-kinases (PI3K) regulates fundamental cellular responses such as proliferation, apoptosis, motility, and adhesion. In particular, the PI3K gamma isoform plays a critical role in the control of cell migration. Despite the attractiveness of PI3-kinases as drug targets, drug discovery efforts have been hampered by the lack of appropriate lipid kinase assay formats suitable for high-throughput screening. The authors report the development of a simple and robust 384-well plate assay that is based on(33) P-phosphate transfer from radiolabeled [gamma(33) P]ATP to phosphatidylinositol immobilized on Maxisorp plates. The established assay format for PI3K gamma was easily adapted to the automated screening platform and was successfully employed for high-throughput screening. Enzymatic and inhibition characteristics of recombinant human PI3K gamma determined with the plate assay are in very good agreement with previously reported values determined in other assay formats. Maximal catalytic activity of PI3K gamma was observed at pH 7.0. The apparent K(m) value for ATP using a 1:1 mixture of phosphatidylinositol and phosphatidylserine was determined to be 7.3 microM (6.0-8.6 microM, 95% confidence interval [CI]). IC(50) values for known PI3-kinase inhibitors were determined to be 1.45 nM (1.17-1.80 nM, 95% CI) for wortmannin and estimated from partial inhibition data to be 1400, 2830, and 21,400 nM for quercetin, LY294002, and staurosporine, respectively. This novel assay approach allows for screening of inhibitors of lipid kinases in high-throughput mode and thereby may facilitate the identification of novel inhibitory structures for drug development.

Adenosine Triphosphate↗

Phagemid encoded small molecules for high throughput screening of chemical libraries.

A new strategy for monovalently displaying small molecules on phage surfaces was developed and applied to high throughput screening for molecules with high binding affinity to the target protein. Peptidyl carrier protein (PCP) excised from nonribosomal peptide synthetase was monovalently displayed on the surface of M13 phage as pIII fusion proteins. Small molecules of diverse structures were conjugated to coenzyme A (CoA) and then covalently attached to the phage displayed PCP by Sfp phosphopantetheinyl transferase. Because Sfp is broadly promiscuous for the transfer of small molecule linked phosphopantetheinyl moieties to apo PCP domains, this approach will enable displaying libraries of small molecules on phage surfaces. Unique 20-base-pair (bp) DNA sequences were also incorporated into the phagemid DNA so that each compound displayed on the phage surface was encoded by a DNA bar code encapsulated inside the phage coat protein. Single round selection of phage displayed small molecules achieved more than 2000-fold enrichment of small molecules with nM binding affinity to the target protein. The selection process is further accelerated by the use of DNA decoding arrays for identifying the selected small molecules.

Bacterial Proteins↗

Evaluation of division-arrested cells for cell-based high-throughput screening and profiling.

Just-in-time cell supply for cell-based high-throughput screening (HTS) is frequently problematic. In addition to scheduling and logistical issues, quality issues and variability due to passage effect, cell cycle, or confluency contribute to day-to-day signal variability in the course of cell-based HTS campaigns. Cell division-arrest and cryopreservation technologies permit the use of cells as assay-ready reagents for HTS and other cell-based profiling and structure-activity studies. In this report, the authors compare division-arrested and dividing cells in 2 assay types that are dependent on movement of proteins within or through cell membranes: a receptor tyrosine kinase assay involving A431 cells responsive to epidermal growth factor, and a secretion reporter assay, which measures secretion of a reporter gene, secreted alkaline phosphatase. In both assays, dividing and division-arrested cells yielded similar basal and maximal signals at a given cell density. Similar IC50s were obtained for reference inhibitors in each assay, type in both dividing and division-arrested cells. In addition, for the secretion reporter assay, when comparing IC50s obtained from 44 compounds randomly chosen from a primary screening hit list, the rank order of potency obtained from dividing cells and division-arrested cells was essentially identical. Furthermore, the results show that, under certain assay conditions, data generated using division-arrested cells are less variable than those generated using dividing cells. In summary, the results suggest that, in many cases, division-arrested cells can substitute for dividing cells and offer certain advantages for cell-based assays.

Alkaline Phosphatase↗

High-throughput screening using beta-lactamase reporter-gene technology for identification of low-molecular-weight antagonists of the human gonadotropin releasing hormone receptor.

G-protein coupled receptors (GPCRs) signal via G-proteins to intracellular second messengers. Assays that link transcription of a detectable reporter to promoters that are activated by such signaling cascades are highly sensitive and allow screening for compounds that either activate or inactivate a GPCR of interest. This study describes the development and performance of an antagonistic screen on the human gonadotropin releasing hormone receptor (GnRH-R). Compounds (245,000) were tested in a high-throughput screen using a Chinese hamster ovary cell line stably expressing the human GnRH-R and the Ca2+ sensitive reporter nuclear factor activated in T-cells/ activator protein-1-beta-lactamase. In total, 4,160 active compounds were identified. Colored and toxic compounds, as well as dust and compound aggregates, have been depicted as artifacts. To deselect non-target hits, several follow-up assays, including luminescent and fluorescent Ca2+ mobilization assays and radioligand binding, were developed for the GnRH-R. These assays were validated using peptide and low-molecular-weight GnRH-R reference compounds before hits from screening were also profiled in these assays. For several reference compounds the use of different assay technologies resulted in a poor correlation of potency values. In conclusion, beta-lactamase as a primary high-throughput screening assay is a powerful complementation to other screening technologies. The beta-lactamase technology has several advantages, including lack of cell lysis and ratiometric read-out, which augments assay robustness. Based on technology comparison, it is not adequate to assume that the same hits would be found regardless of which assay technology is used.

Animals↗

Fast gradient elution reversed-phase high-performance liquid chromatography with diode-array detection as a high-throughput screening method for drugs of abuse. I. Chromatographic conditions.

A new approach for the high-throughput screening of biological samples to detect the presence of regulated intoxicants has been developed by modifying a conventional gradient elution high-performance liquid chromatograph (HPLC). The goal of this work was to improve the speed of gradient elution screening methods over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which is the basis for the identification of intoxicant compounds. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between consecutive gradient runs, thereby reducing the total time for each analysis. The total analysis time for each gradient elution run is only 2.80 min, including 0.30 min for column re-equilibration between analyses. Retention times of standard calibration solutes are reproducible to better than 0.002 min in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. For a set of forty-seven target compounds, the discriminating power and mean list length were found to be 0.95 and 3.26, respectively. In comparison to previous work with similar numbers of target compounds, the current approach provides an order of magnitude improvement in analysis time, and a four-fold decrease in mean list length.

Chromatography, High Pressure Liquid↗

[High throughput screening method of nitric oxide synthase inhibitors and enhancers].

AIM: In order to discover new inhibitors and enhancers of nitric oxide synthase (NOS), an in vitro assay to determine NOS activity was established for high throughput screening. METHODS: The activity of NOS was detected based on the change of nicotinamide-adenine dinucleotide phosphate (NADPH) concentration in the reaction system by the fluorescence density. The enzyme was prepared from bovine brain by gradient centrifugation. The reaction performed in black 96 well micro-plate with a final volume of 90 microL. Every factor which would affect the results such as the concentration of NADPH, L-arginine (L-Arg, used as substrate) and enzyme protein was optimized in different conditions. At last, 5,600 samples (compounds and extracts) were screened by the method. RESULTS: The test signal (fluorescence density) in the reaction system was influenced by many different factors such as temperature and concentration of substrates. The ideal system contains protein 1.50 mg.mL-1, L-Arg 1 mmol.L-1, NADPH 0.1 mmol.L-1 at 37 degrees C. In this method, there were about 2% samples which emit fluorescence, and about 0.5% samples which quench the fluorescence. So these samples were deleted from the sample library. The effects of these samples on activity of NOS were distributed in a normal manner. About 2% samples had potential effects on the NOS activity (including inhibitors and enhancers). CONCLUSION: The method can be performed by high throughput screening and gives the stable data, not only for inhibitors, but also for enhancers of NOS activity.

Animals↗

Rapid screening of chemical inhibitors that block processive DNA synthesis of herpesviruses: potential application to high-throughput screening.

Processivity factors associate with DNA polymerases, enabling them to incorporate thousands of nucleotides without dissociating from the template. The processivity factors encoded by each of the herpesviruses are ideal targets for specifically blocking viral replication, particularly since they have unique primary amino acid sequences. Here we provide details of a rapid mechanistic plate assay and its potential application to high-throughput screening of libraries of tens of thousands of chemical compounds to identify inhibitors of processive DNA synthesis. Methods of validation testing are presented.

DNA↗

In vitro high-throughput screening assay for modulators of transcription.

We developed a 96-well microtiter-plate high-throughput screening (HTS) assay for the detection of modulators of transcription. This HTS assay consists of three steps: (1) the in vitro transcription reaction; (2) modification and hybridization of RNA products; and (3) washing and quantification. During the first step, a DNA template containing the promoter of interest upstream of a cassette lacking guanosine residues in one of its strands (G-less cassette) is incubated with nuclear extract and the necessary cofactors/activators and substrates. During the second step, the in vitro synthesized transcripts are digested with RNase T1 and hybridized to two DNA oligonucleotides. One oligonucleotide is biotinylated for trapping of the RNA products to a streptavidin-coated plate, and the other is europium-labeled for detection by time-resolved fluorescence. We show that this assay is highly reproducible and robust, yielding results comparable to those obtained by standard methodologies employing radioactive nucleotide incorporation and gel electrophoresis while offering a very significant advantage in terms of throughput (>2000 assay points per operator per day). We demonstrate the usefulness of the assay for the discovery of small molecule inhibitors of transcription, and applications of this approach for the high-throughput discovery of transcriptional modulators are discussed.

Amanitins↗

Adaptation of aequorin functional assay to high throughput screening.

AequoScreen, a cellular aequorin-based functional assay, has been optimized for luminescent high-throughput screening (HTS) of G protein-coupled receptor (GPCRs). AequoScreen is a homogeneous assay in which the cells are loaded with the apoaequorin cofactor coelenterazine, diluted in assay buffer, and injected into plates containing the samples to be tested. A flash of light is emitted following the calcium increase resulting from the activation of the GPCR by the sample. Here we have validated a new plate reader, the Hamamatsu Photonics FDSS6000, for HTS in 96- and 384-well plates with CHO-K1 cells stably coexpressing mitochondrial apoaequorin and different GPCRs (AequoScreen cell lines). The acquisition time, plate type, and cell number per well have been optimized to obtain concentration-response curves with 4000 cells/well in 384-well plates and a high signal:background ratio. The FDSS6000 and AequoScreen cell lines allow reading of twenty 96- or 384-well plates in 1 h with Z' values of 0.71 and 0.78, respectively. These results bring new insights to functional assays, and therefore reinforce the interest in aequorin-based assays in a HTS environment.

Aequorin↗