Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “GASES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Biochemical effects on combined gases of nitrogen dioxide and ozone. I. Species differences of lipid peroxides and phospholipids in lungs.

In the present study, changes of lipid peroxides, phospholipids and antioxidant levels in lungs of 4 animal species exposed to the combined gases of NO2 and O3 were compared. Male mice, hamsters, rats and guinea pigs were used. Lipid peroxides were increased significantly in the lungs of mice and guinea pigs exposed to the combined gases, but not in hamsters and rats. Changes of alpha-tocopherol (VE) contents were slight. On the other hand, non-protein sulfhydryl (NPSH) contents were increased strikingly, especially in hamsters, but were not increased in guinea pigs. Phosphatidylcholine (PC) contents were increased and phosphatidylethanolamine (PE) contents were decreased by the exposure to the combined gases, with the order guinea pig greater than mouse greater than rat. In hamsters no changes were seen. The changes of fatty acid composition in guinea pigs and mice were marked, the increases of palmitate and palmitolate and the decreases of polyunsaturated fatty acid were especially characteristic. These changes in phospholipid class and fatty acid composition may be a "a kind of adaptation phenomenon" to avoid further lipid peroxidation. On the other hand, the changes in hamsters and rats were small. The results show the existence of species differences in lipid peroxide formation by exposure to the combined gases of NO2 and O3. They were found to be related to the contents of antioxidants and the compositions of phospholipids and their fatty acids.

Animals↗

Venous and arterial blood gases during and after cardiopulmonary resuscitation in dogs.

This study was undertaken to characterize blood gas, pH, and lactate changes during and after cardiopulmonary resuscitation (CPR) in arterial and venous samples. Blood samples were withdrawn from the brachial artery, aortic arch, pulmonary artery, coronary sinus, and either the right or left cardiac ventricle of 24 anesthetized dogs. Ventricular fibrillation (VF) was induced electrically, and mechanical CPR was begun. Blood samples were withdrawn before CPR, at 2, 5, 7, and 9 minutes during CPR, and at 1, 3, 10, 30, and 60 minutes after defibrillation. Control arterial and venous samples indicated mild metabolic acidosis. During CPR, there was a significant arteriovenous difference in pH, PCO2, and PO2. With ventilation onset, arterial pH increased 0.25 units, PCO2 decreased 22 mm Hg, and PO2 increased 200 mm Hg. Venous blood gases exhibited gradual changes during the CPR period. With the re-establishment of circulation and spontaneous respirations, both the arterial and venous pH levels decreased to nearly 7.1, and PCO2 approached 40 mm Hg. Lactate increased to 32 mg/dl during 9 minutes of CPR and did not significantly differ after defibrillation. Blood gases and pH returned to control values within an hour. This study suggests that arterial blood gases are sensitive to rapid changes occurring in the pulmonary capillary bed, while venous blood gases reflect changes occurring in the systemic capillary bed.

Animals↗

A comparison of venous blood gases during cardiac arrest.

Previous reports have advocated the use of mixed venous blood gases to estimate arterial pH and as a reflection of tissue acid-based balance. However, true mixed venous samples are difficult to obtain during cardiac arrest as they require a pulmonary artery catheter. The purpose of this study was to determine whether central or femoral venous samples could be used in place of pulmonary artery samples. Blood gases from these sites were drawn at intervals during experimental cardiac arrest in dogs. The PO2, PCO2, and pH from the pulmonary artery samples were strongly correlated with those from the central venous (r = .93, .99, and .99, respectively) and from the femoral venous samples (r = .73, .93, and .97, respectively). There were no significant differences in the pulmonary artery, central, or femoral venous gases. This animal model suggests that femoral and central venous samples mirror true mixed venous blood gases from the pulmonary artery and could be used in their place.

Animals↗

Day/night pattern of arterial blood gases in the cow.

Both metabolic rate and pulmonary ventilation change throughout 24h with a circadian pattern. Because their changes occur almost in synchrony and by a similar amount, blood gases may remain steady within a narrow range. We tested this possibility in five cows (Bos taurus, Bruna Italiana breed), maintained in a stable at 29 degrees C, under natural light-dark (LD) regime, by measuring arterial blood gases every 3h for 2 days. All cows presented a clear day/night pattern of body temperature (T(b)), with an average peak-trough difference (PTD) of 0.5 degrees C. Breathing rate oscillated significantly in three out of five animals, with a group-mean PTD of 2 breaths per minute, and it was time-advanced with respect to the oscillation of T(b). Significant oscillations in arterial pH, bicarbonate, partial pressure of oxygen and partial pressure of carbon dioxide (Pa(CO2) ) were observed in, respectively, 1 cow out of 5, 1/5, 3/5 and 5/5. Of all these variables, group-mean analysis revealed a significant day/night pattern only for Pa(CO2), and even in this case the average PTD was less than 1 mmHg. We conclude that, in the cow, blood gases remain remarkably stable throughout the 24 h. Hence, the daily oscillations of body temperature, breathing rate, and probably of many other factors affecting metabolic rate and pulmonary ventilation do not preclude an excellent homeostasis of blood gases.

Acid-Base Equilibrium↗

Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry.

Effects of carrier gas type (N2, O2, CO2, N2O, and SF6) on changes in the ratio of high- to low-field ion mobility, Kh/K, of cesium, gramicidin S, tetrahexylammonium, heptadecanoic acid, and aspartic acid in fields of up to 67 Td are presented. The theory of the mobility of ions at high E/N in different gases is discussed. Plots of Kh/K as a function of the ionic energy parameter, E/N, for the five ions in each of the gases were derived from experimental data collected using a high-field asymmetric waveform ion mobility spectrometer. The change in the ratio of high- to low-field ion mobility of cesium in carrier gases of O2 and N2 showed excellent agreement with literature values. The behavior of cesium in O2 and N2 is used to illustrate that the ratio Kh/K as a function of effective temperature is invariant with gas type as long as the well depth of the interaction potential significantly exceeds thermal energy. From these results, it appears that the well depth of the interaction potential of the heavier ions studied here, including gramicidin S, tetrahexylammonium, and heptadecanoic acid, with bath gases such as N2 and O2, is shallow relative to thermal energy.

Journal Article↗

Simultaneous determination of dissolved gases and moisture in mineral insulating oils by static headspace gas chromatography with helium photoionization pulsed discharge detection.

This paper presents the development of a static headspace capillary gas chromatographic method (HS-GC) for simultaneously determining dissolved gases (H2, O2, N2, CO, CO2, CH4, C2H6, C2H4, C2H2, C3H8) and moisture from a unique 15-mL mineral oil sample. A headspace sampler device is used to equilibrate the sample species in a two-phase system under controlled temperature and agitation conditions. A portion of the equilibrated species is then automatically split-injected into two chromatographic channels mounted on the same GC for their separation. The hydrocarbons and the lighter gases are separated on the first channel by a GS-Q column coupled with a MolSieve 5-A column via a bypass valve, while the moisture is separated on the second channel using a Stabilwax column. The analytes are detected by using two universal pulsed-discharge helium ionization detectors (PDHID). The performance of the method was established using equilibrated vials containing known amounts of gas mixture, water, and blank oil. The signal is linear over the concentration ranges normally found for samples collected from open-breathing power transformers. Determination sensitivity varies with the nature of the species considered with values as high as 21 500 A x 10(-9) s (microg/ g)(-1) for H2O, 46-216 A x 10(-9) s (microL/L)(-1) for the hydrocarbons and carbon oxides, and as low as 8-21 A x 10(-9) s (microL/L)(-1) for the O2 and N2 permanent gases. The detection limit of the method is between 0.08 and 6 microL/L for the dissolved gases, except for O2, N2, and CO2, where higher values are observed due to air intrusion during sampler operations, and 0.1 microg/g for the dissolved water. Ten consecutive measurements in the low and high levels of the calibration curves have shown a precision better than 12% and 6%, respectively, in all cases. A comparison study between the HS-GC method and the ASTM standard procedures on 31 field samples showed a very good agreement of the results. The advantages of configuring the arrangement with two PDHID over the conventional flame ionization and thermal conductivity detectors were clearly demonstrated.

Journal Article↗

Controlled confinement and release of gases in single-walled carbon nanotube bundles.

A simple procedure is described that locks small quantities of SF6, CO2, and 13CO2 into opened single-walled carbon nanotube (SWNT) bundles and keeps the gas in the SWNTs above the desorption temperature of these molecules. The technique involves opening the SWNTs with ozonolysis at 300 K followed by vacuum-annealing at 700 K. Gases are then cryogenically adsorbed into the opened SWNTs and locked into the SWNT pores by functionalizing the sample with a low-temperature ozone treatment. The low-temperature ozone treatment functionalizes the entry ports into the SWNT pores, which in turn create a physical barrier for gases trying to desorb through these functionalized ports. The samples are stable under vacuum for periods of at least 24 h, and the trapped gases can be released by vacuum-heating to 700 K. Reduced quantities of the trapped gases remain in the SWNTs even after exposure to room air. Fourier transform infrared spectroscopy is used to monitor the functionalities resulting from the ozone treatment and to detect the trapped gas species.

Journal Article↗

Palaeotemperature reconstruction from noble gases in ground water taking into account equilibration with entrapped air

Noble-gas concentrations in ground water have been used as a proxy for past air temperatures, but the accuracy of this approach has been limited by the existence of a temperature-independent component of the noble gases in ground water, termed 'excess air' whose origin and composition is poorly understood. In particular, the evidence from noble gases in a Brazilian aquifer for a cooling of more than 5 C in tropical America during the Last Glacial Maximum has been called into question. Here we propose a model for dissolved gases in ground water, which describes the formation of excess air by equilibration of ground water with entrapped air in quasi-saturated soils. Our model predicts previously unexplained noble-gas data sets, including the concentration of atmospheric helium, and yields consistent results for the non-atmospheric helium isotopes that are used for dating ground water. Using this model of excess air, we re-evaluate the use of noble gases from ground water for reconstructing past temperatures. Our results corroborate the inferred cooling in Brazil during the Last Glacial Maximum, and indicate that even larger cooling took place at mid-latitudes.

Journal Article↗

Integrated model shows that atmospheric brown clouds and greenhouse gases have reduced rice harvests in India.

Previous studies have found that atmospheric brown clouds partially offset the warming effects of greenhouse gases. This finding suggests a tradeoff between the impacts of reducing emissions of aerosols and greenhouse gases. Results from a statistical model of historical rice harvests in India, coupled with regional climate scenarios from a parallel climate model, indicate that joint reductions in brown clouds and greenhouse gases would in fact have complementary, positive impacts on harvests. The results also imply that adverse climate changes due to brown clouds and greenhouse gases contributed to the slowdown in harvest growth that occurred during the past two decades.

Air Pollutants↗

Lack of effect of single high doses of buprenorphine on arterial blood gases in the rat.

High dose buprenorphine, a potent semisynthetic agonist-antagonist for opiate receptors, is now used in substitution treatment of human heroin addiction. Deaths have been reported in addicts misusing buprenorphine. We determined the median lethal dose (LD(50)) and studied the effects of high doses of intravenous buprenorphine on arterial blood gases in rats. Male Sprague-Dawley rats were administered buprenorphine intravenously to determine the LD(50) using the up-and-down method. Subsequently, catheterized groups of 10 restrained rats received no drug, saline, acid-alcohol aqueous solvent (required to dissolve buprenorphine at a high concentration), or 3, 30, or 90 mg/kg of buprenorphine intravenously. Serial arterial blood gases were obtained over 3 h. The LD(50) determined in triplicate was 146.5 mg/kg (median of 3 series, range: 142.6-176.5). The mean dose received by surviving animals was 96.9 +/- 46.7 mg/kg. There was a significant effect of the acid-alcohol aqueous solvent on arterial blood gases. Excluding the solvent effect, 3, 30, and 90-mg/kg buprenorphine doses had no significant effects on arterial blood gases. The toxicity of intravenous buprenorphine in adult rats, assessed by the LD(50), is low. These data are consistent with a wide margin of safety of buprenorphine. The mechanism of death after the intravenous administration of a lethal dose of buprenorphine remains to be determined.

Animals↗

Trace rare gases optical emission spectroscopy: nonintrusive method for measuring electron temperatures in low-pressure, low-temperature plasmas.

Trace rare gases optical emission spectroscopy (TRG-OES) is a new, nonintrusive method for determining electron temperatures (T(e)) and, under some conditions, estimating electron densities (n(e)) in low-temperature, low-pressure plasmas. The method is based on a comparison of atomic emission intensities from trace amounts of rare gases (an equimixture of He, Ne, Ar, Kr, and Xe) added to the plasma, with intensities calculated from a model. For Maxwellian electron energy distribution functions (EEDFs), T(e) is determined from the best fit of theory to the experimental measurements. For non-Maxwellian EEDFs, T(e) derived from the best fit describes the high-energy tail of the EEDF. This method was reported previously, and was further developed and successfully applied to several laboratory and commercial plasma reactors. It has also been used in investigations of correlations between high-T(e) and plasma-induced damage to thin gate oxide layers. In this paper, we provide a refined mechanism for the method and include a detailed description of the generation of emission from the Paschen 2p manifold of rare gases both from the ground state and through metastable states, a theoretical model to calculate the number density of metastables (n(m)) of the rare gases, a practical procedure to compute T(e) from the ratios of experimental-to-theoretical intensity ratios, a way to determine the electron density (n(e)), a discussion of the range of sensitivity of TRG-OES to the EEDF, and an estimate of the accuracy of T(e). The values of T(e) obtained by TRG-OES in a transformer-coupled plasma reactor are compared with those obtained with a Langmuir probe for a wide range of pressures and powers. The differences in T(e) from the two methods are explained in terms of the EEDF dependence on pressure.

Journal Article↗

Preservation of humidity and heat of respiratory gases in spontaneously breathing, tracheostomized patients.

BACKGROUND: Ventilation with endotracheal intubation bypasses the upper airway and the normal heat and moisture exchanging process of inspired gases. A continuous loss of moisture and heat occurs and predisposes patients to serious airway damage. We therefore prospectively studied one heated humidifier system, one cold humidifier system and one heat and moisture exchanger in spontaneously breathing, tracheostomized intensive care unit patients to determine the ability to preserve patients' heat and water. METHODS: Following a randomized order, 10 patients were spontaneously ventilated for 24-h periods with the Nam 35 humidifier (Europe Medical, France, a cold water humidifier), the heat and moisture exchange Trach-Vent (Gibeck, Sweden), and the Aerodyne humidifier (Kendall USA). In each patient, during the inspiration phase, the following measurements were performed: mean values of temperature and relative humidity of inspired gases. The absolute humidity was calculated. Values were obtained in each patients after 40 min and 24 h. RESULTS: The Trach-Vent filter and the Aerodyne humidifier had better humidification and thermic capacities than the Nam 35 humidifier (P < 0.001). With the Nam 35 humidifier, no patient had temperature of inspired gas > 29 degrees C. Concerning absolute humidity of inspired gases, the Nam 35 humidifier achieved a lower performance than the other two tested systems (P < 0.001). CONCLUSION: In spontaneously breathing, tracheostomized intensive care unit patients, the Trach-Vent heat and moisture exchanger and the Aerodyne heated system achieved satisfactorily preservation of heat and humidity of inspired gases.

Body Temperature↗

Two-pore-domain K+ channels are a novel target for the anesthetic gases xenon, nitrous oxide, and cyclopropane.

Nitrous oxide, xenon, and cyclopropane are anesthetic gases that have a distinct pharmacological profile. Whereas the molecular basis for their anesthetic actions remains unclear, they behave very differently to most other general anesthetics in that they have little or no effect on GABAA receptors, yet strongly inhibit the N-methyl-d-aspartate subtype of glutamate receptors. Here we show that certain members of the two-pore-domain K+ channel superfamily may represent an important new target for these gaseous anesthetics. TREK-1 is markedly activated by clinically relevant concentrations of nitrous oxide, xenon, and cyclopropane. In contrast, TASK-3, a member of this family that is very sensitive to volatile anesthetics, such as halothane, is insensitive to the anesthetic gases. We demonstrate that the C-terminal cytoplasmic domain is not an absolute requirement for the actions of the gases, although it clearly plays an important modulatory role. Finally, we show that Glu306, an amino acid that has previously been found to be important in the modulation of TREK-1 by arachidonic acid, membrane stretch and internal pH, is critical for the activating effects of the anesthetic gases.

Anesthetics, Inhalation↗

Primordial noble gases from Earth's mantle: identification of a primitive volatile component

Carbon dioxide well gases in Colorado, New Mexico, and South Australia show excesses of (124-128)Xe correlated with (129)I-derived (129)Xe and (20)Ne/(22)Ne ratios that are higher than the atmospheric (20)Ne/(22)Ne ratio. The xenon isotopic data indicate the presence of a solarlike component deep within Earth. The presence of this component in crustal and upper mantle reservoirs may be explained by a steady-state transport of noble gases from the lower mantle, which still retains much of its juvenile volatile inventory. These measurements also indicate that the mantle source of these noble gases in the carbon dioxide well gases cannot be the source of Earth's present atmosphere. The variations observed in (129)Xe/(130)Xe between solar wind xenon, Earth's atmosphere, and mantle samples may be generated by variations of iodine/xenon in terrestrial reservoirs, as opposed to rapid early degassing.

Journal Article↗

Specific inhibition of antenna bacteriochlorophyll synthesis in Chlorobium vibrioforme by anesthetic gases.

The green sulfur bacterium Chlorobium vibrioforme contains two types of bacteriochlorophyll (Bchl). The minor pigment, Bchl a, is associated primarily with the cell membrane and its reaction centers; and the major light-harvesting antenna pigment, Bchl d, is found primarily in the chlorosomes, which are attached to the inner surface of the cell membrane. Anesthetic gases, such as N2O, ethylene, and acetylene, were found to inhibit the synthesis of Bchl d, but not of Bchl a, thus allowing the cells to grow at high light intensities with a greatly diminished content of antenna pigment. Chlorosomes were absent or sparse in inhibited cells. Porphyrins accumulated in the inhibited cells. The major one was identified as the Bchl precursor magnesium-protoporphyrin IX monomethyl ester (Mg-PPME) by comparative absorption and fluorescence spectroscopy and thin-layer chromatography of the porphyrin and its derivatives with those of authentic protoporphyrin IX. Small amounts of Mg-PPME were present in control cells, but the addition of inhibitor caused a rapid increase in the Mg-PPME concentration, accompanying the inhibition of Bchl d synthesis. Cells grown in the presence of ethephon (as a source of ethylene) and allowed to stand in dim light for long periods accumulated large amounts of PPME and other porphyrins and excreted or released porphyrins, which accumulated as a brown precipitate in the culture. Inhibition of Bchl d synthesis was relieved upon removal of the inhibitor. These results suggest that the gases act at a step in pigment biosynthesis that affects the utilization of Mg-PPME for isocyclic ring formation. Synthesis of Bchl d and Bchl a may be differentially affected by the gases because of compartmentation of their biosynthetic apparatus or because competition for precursors favors Bchl a synthesis. An ethephon-resistant mutant strain was isolated by selection for growth in dim, long-wavelength light. The mutant cells were also resistant to acetylene, but not to N2O. The ability to reversibly generate viable Chlorobium cells that lack antenna pigments may be useful in photosynthesis research. The ethephon- and acetylene-resistant strain may be useful in the study of the enzymes and genes that are involved in the biosynthetic step that the gases affect.

Acetylene↗

Growth responses of Neurospora crassa to increased partial pressures of the noble gases and nitrogen.

Buchheit, R. G. (Union Carbide Corp., Tonawanda, N.Y.), H. R. Schreiner, and G. F. Doebbler. Growth responses of Neurospora crassa to increased partial pressures of the noble gases and nitrogen. J. Bacteriol. 91:622-627. 1966.-Growth rate of the fungus Neurospora crassa depends in part on the nature of metabolically "inert gas" present in its environment. At high partial pressures, the noble gas elements (helium, neon, argon, krypton, and xenon) inhibit growth in the order: Xe > Kr> Ar >> Ne >> He. Nitrogen (N(2)) closely resembles He in inhibitory effectiveness. Partial pressures required for 50% inhibition of growth were: Xe (0.8 atm), Kr (1.6 atm), Ar (3.8 atm), Ne (35 atm), and He ( approximately 300 atm). With respect to inhibition of growth, the noble gases and N(2) differ qualitatively and quantitatively from the order of effectiveness found with other biological effects, i.e., narcosis, inhibition of insect development, depression of O(2)-dependent radiation sensitivity, and effects on tissue-slice glycolysis and respiration. Partial pressures giving 50% inhibition of N. crassa growth parallel various physical properties (i.e., solubilities, solubility ratios, etc.) of the noble gases. Linear correlation of 50% inhibition pressures to the polarizability and of the logarithm of pressure to the first and second ionization potentials suggests the involvement of weak intermolecular interactions or charge-transfer in the biological activity of the noble gases.

Argon↗

Risk of spontaneous abortion in women occupationally exposed to anaesthetic gases: a meta-analysis.

OBJECTIVES: To determine the association between maternal occupational exposure to anaesthetic gases and risk of spontaneous abortion. METHODS: A meta-analysis was performed of published epidemiological studies identified from literature reviews, unsystematic perusal of reference lists of relevant publications, and two Medline searches (1984-92, keywords: anaesthetic gases; anaesthetics; anaesthetics, local; operating rooms; operating room nursing; pregnancy; abortion; 1985-92, keywords: anaesthetics; adverse effects; occupational exposure; anaesthesia, inhalation; operating room nursing; pregnancy; abortion). All peer reviewed studies were retained. Student theses were excluded, as were conference abstracts, unpublished material, and two studies in which data on paternal and maternal occupational exposures were pooled. The relative risk of spontaneous abortion was estimated. RESULTS: One study found no increase in risk of abortion when gases were scavenged or when the exposure to unscavenged gases was low. None of the studies included ambient gas sampling. 24 comparisons between exposed and unexposed women, obtained from 19 reports, were included. The overall relative risk was 1.48 (95% confidence interval (95% CI), 1.4 to 1.58). To test whether this result was influenced by the quality of the studies, the validity of the reviewed papers was rated on the basis of three criteria: appropriateness of the unexposed comparison group, control for non-occupational confounding variables, and response rate. The estimate of risk increased to 1.9 (95% CI, 1.72 to 2.09) when analysis was restricted to the six comparisons which were rated the most rigorous. CONCLUSIONS: Epidemiological studies based on data obtained in the prescavenging era indicate an increased risk of spontaneous abortion. The estimated increased risk was not diminished but rather increased by exclusion of the more methodologically flawed studies.

Abortion, Spontaneous↗

Permeation of inert gases through human skin: modeling the effect of skin blood flow.

We present an analytic method for determining the effects of skin perfusion--vasculature and flow rates--on the flux of inert gases through human skin. We systematically specify the underlying blood flow and examine the resulting fluxes of several gases, allowing for the appropriate tissue resistances. For physiological flows, the stratum corneum has an effect equivalent to a series resistance. Helium flux at low total flow depends primarily on subdermal perfusion, but at higher flow, middermal and subpapillary effects become important. The fluxes of less permeable gases, such as argon and xenon, depend on middermal and subpapillary flow at lower total flows. From any single measurement of gas flux, it is difficult to establish an unambiguous value for the underlying blood flow, but the simultaneous measurement of different gases narrows the range of plausible conditions.

Argon↗