Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DXA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Heritability of body composition measured by DXA in the diabetes heart study.

OBJECTIVE: The purpose of this study was to investigate the heritability of body composition measured by DXA in the Diabetes Heart Study (DHS). RESEARCH METHODS AND PROCEDURES: Participants were 292 women and 262 men (age, 38 to 86 years; BMI, 17 to 57 kg/m(2)) from 244 families. There were 492 white and 49 African-American sibling pairs. DXA measurements of percentage fat mass (FM), whole body FM, and lean mass (LM), as well as regional measurements of trunk fat mass (TFM) and appendicular lean mass (ALM), were obtained. Heritability of FM, LM, and BMI were estimated using Sequential Oligogenic Linkage Analysis Routines. RESULTS: After adjusting for age, gender, ethnicity, and height, the heritability estimates of various compositional attributes were %FM = 0.64, whole body FM = 0.71, TFM = 0.63, whole body LM = 0.60, ALM = 0.66, and BMI = 0.64 (all p < 0.0001). Additional adjustment for diabetes status, smoking, dietary intake, and physical activity resulted in only minor changes in the heritability estimates (h(2) = 0.63 to 0.72, all p < 0.0001). Furthermore, heritability of TFM after additional adjustment for whole body FM was significant (h(2) = 0.55, p < 0.0001), and heritability of ALM after additional adjustment for whole body LM was also significant (h(2) = 0.51, p < 0.0001). DISCUSSION: These data suggest that FM and LM measured by DXA are highly heritable and can be effectively used in designing linkage studies to locate genes governing body composition. In addition, regional distribution of FM and LM may be genetically determined.

Absorptiometry, Photon↗

Prediction of DXA-determined whole body fat from skinfolds: importance of including skinfolds from the thigh and calf in young, healthy men and women.

OBJECTIVE: To investigate the relationship of percent body fat (%fat), assessed by dual energy-X-ray absorptiometry (DXA) or a four-compartment model, with upper body and lower limb skinfolds. DESIGN: Cross-sectional design involving forward stepwise and hierarchical multiple regression analyses to assess the relationship of %fat with skinfolds and a combination of four commonly used upper body skinfolds (biceps, triceps, subscapular and iliac crest) with the calf and thigh skinfolds. SETTING: University research laboratory. SUBJECTS: In all, 31 females, mean age 20.9 (+/-2.0) y, and 21 males, mean age 22.3 (+/-5.5) y volunteered for this study, which was approved by the Ethics Committee of the School of Sport, Health and Exercise Sciences, University of Wales, Bangor. MEASUREMENTS: %fat from DXA in both groups, and %fat from a four-compartment (water, bone mineral mass, fat and residual) model (%fat4C) in females only. Skinfolds were measured at the abdomen, iliac crest, biceps, triceps, subscapular, calf and thigh. RESULTS: All skinfolds were positively associated with DXA estimates of %fat (P < 0.01). In males and females, the thigh skinfold had the highest correlation with %fat. This was also observed when %fat4C was used as the criterion in females. Stepwise multiple regression analysis using %fatDXA as the criterion selected the thigh (R(2) = 0.82), calf (R(2) change 0.04) and iliac crest (R(2) change = 0.03) for females, and the thigh (R(2) = 0.79), iliac crest (R(2) change = 0.11) and abdomen (R(2) change = 0.03) for males (all P < 0.01). When %fat4C was used as the criterion in the females, only the thigh was selected as a significant predictor (R(2) = 0.76). Independent prediction factors were created from the sum of biceps, triceps, subscapular and iliac crest (sigma4skf) and from the sum of the thigh and calf (sigmathigh + calf). These factors were then entered into a hierarchical multiple linear regression analysis to predict percent fat. Order of entry was varied to allow the assessment of unique variance accounted for by each predictor. The sum of the thigh and calf explained more variance in %fatDXA than that explained by the sigma4skf alone, irrespective of the order of entry in both males and females. This was also observed when %fat4C was used as the criterion in the females. CONCLUSIONS: The results of this study confirm that lower body skinfolds are highly related to percent body fat in fit and healthy young men and women, and uphold current recommendations by the British Olympic Association to include the thigh skinfold with sigma4skf. Conventional use of the sigma4skf to estimate percent body fat is significantly enhanced by the inclusion of the thigh and calf skinfolds, either independently or in combination. In this group of males and females, the sum of the thigh and calf skinfolds accounted for the most variance in percent fat.

Absorptiometry, Photon↗

Assessment of bone mineralization following renal transplantation in children: limitations of DXA and the confounding effects of delayed growth and development.

Pediatric renal transplantation recipients have numerous risk factors for decreased bone mass, including the underlying renal disease, nutritional deficits, decreased physical activity, inflammation and exposure to steroid therapy. The assessment of bone mineralization in children following renal transplantation is fraught with difficulty. Dual energy x-ray absorptiometry (DXA) is the most commonly employed tool to assess bone mineralization. However, DXA has important limitations in children and in individuals with renal disease. This brief review will examine the expected gains in bone size and bone mass during growth and the mechanisms by which renal failure and steroid therapy interrupt these process. In addition, the limitations of DXA for detecting impaired bone mineralization in children with renal disease are reviewed and alternative approaches explored.

Absorptiometry, Photon↗

Volumetric measurements of bone mineral density of the lumbar spine: comparison of three geometrical approximations using dual-energy X-ray absorptiometry (DXA)

Measurements of bone mineral density using dual-energy X-ray absorptiometry (DXA) gives area values (g cm-2) rather than true volumetric values (g cm-3). To calculate the vertebral volume using planar postero-anterior and lateral DXA values, several different geometrical approximations were used: cubic, cylindrical with a circular cross-section and cylindrical with an elliptical cross-section. The aim of this study was to compare these geometrical approximations with each other and with a reference standard, defined as the volume found on a computed tomographic (CT) scan. L2 and L3 were evaluated in a phantom study. Volume approximations by the cube or cylinder with circular cross-section geometry showed more than a 50% overestimation (range 54-74%). However, the elliptical cylinder approach showed very good agreement: 2.1% and 1.2% for L2 and L3, respectively, when compared to the CT volumes. In addition, we performed four patient studies with both CT and DXA to evaluate the elliptical cylinder estimate in a clinical setting. For L2 and L3, the mean relative difference was less than 2%. We conclude that the elliptical cylinder approach results in the most accurate bone volume estimates in both the phantom and patients.

Absorptiometry, Photon↗

Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA.

A simulation study was performed to evaluate a new set of calibration standards for estimating the fat content of the body via dual-photon absorptiometry (DPA) and dual-energy x-ray absorptiometry (DXA). The standards, proposed by Nord and Payne [presented at the 2nd meeting of The Bath Conference on Bone Mineral Measurement (1990)] consist of stearic acid (100% fat) and 0.6% NaCl in water (100% lean). They were compared with other standards consisting of average composition adipose/muscle tissues and fatty adipose/lean muscle tissues. Source and detector properties of a Gd-153 DPA system and three commercial DXA systems were modeled. For each system and calibration set, rms errors in the calculated fat contents of simulated tissues having fat mass percentages that ranged from about 4%-44% and thicknesses that ranged from 5-20 cm were determined. Beam hardening errors for the systems were evaluated as was a calibration technique employed by one of the manufacturers to correct for such errors. In general, the smallest rms errors (2% or less when the calibration standards and tissues were of equal thickness) were obtained with the average adipose/muscle standards. Equivalent results were obtained with standards consisting of stearic acid and 0.8% NaCl. The latter is a higher salt content than proposed by Nord and Payne and results from differences in the x-ray attenuation coefficients that were employed in calculating the fat equivalence of water. Other, more convenient standards, such as lucite and water may be employed by using appropriate fat equivalences (approximately 69% for lucite and approximately 10% for water). Beam hardening errors for the DXA systems are considerable, and the simulated correction technique was shown to be effective.

Absorptiometry, Photon↗

Analysis of proximal femur DXA scans in growing children: comparisons of different protocols for cross-sectional 8-month and 7-year longitudinal data.

Dual-energy X-ray absorptiometry (DXA) is a widely used method for measuring bone mineral in the growing skeleton. Because scan analysis in children offers a number of challenges, we compared DXA results using six analysis methods at the total proximal femur (PF) and five methods at the femoral neck (FN). In total we assessed 50 scans (25 boys, 25 girls) from two separate studies for cross-sectional differences in bone area, bone mineral content (BMC), and areal bone mineral density (aBMD) and for percentage change over the short term (8 months) and long term (7 years). At the proximal femur for the short-term longitudinal analysis, there was an approximate 3.5% greater change in bone area and BMC when the global region of interest (ROI) was allowed to increase in size between years as compared with when the global ROI was held constant. Trend analysis showed a significant (p < 0.05) difference between scan analysis methods for bone area and BMC across 7 years. At the femoral neck, cross-sectional analysis using a narrower (from default) ROI, without change in location, resulted in a 12.9 and 12.6% smaller bone area and BMC, respectively (both p < 0.001). Changes in FN area and BMC over 8 months were significantly greater (2.3%, p < 0.05) using a narrower FN rather than the default ROI. Similarly, the 7-year longitudinal data revealed that differences between scan analysis methods were greatest when the narrower FN ROI was maintained across all years (p < 0.001). For aBMD there were no significant differences in group means between analysis methods at either the PF or FN. Our findings show the need to standardize the analysis of proximal femur DXA scans in growing children.

Absorptiometry, Photon↗

Reproducibility of DXA in obese women.

Dual-energy X-ray absorptiometry (DXA) measurements were analyzed using two versions of software (Hologic V8.1a and V8.21) to compare the short- and long-term precisions of the measurements. Software V8.21 was designed by the manufacturer to better address magnification effects on estimations of soft tissue lean mass. Twenty weight-stable, obese postmenopausal Caucasian women aged 40-70 yr participated in the study. Total and regional body composition measurements were obtained at baseline and after 3 mo, using a fan beam Hologic QDR 4500A absorptiometer. For the estimation of precision, duplicate scans obtained on the same day for nine women were analyzed using both versions of the software. The correlations between duplicate scans ranged from 0.886 to 0.998 and were similar between software versions. The CVs for fat and lean weights and bone mineral content (BMC) were 1.2%, 1.1%, and 1.7%, respectively, for software V8.21 compared to 1.3%, 1.3%, and 2.1%, respectively, for V8.1a. Systematic differences were found between software versions with higher values for fat and lean weights for software version V8.21. The 3-mo, long-term reproducibility of body composition estimates from DXA was only slightly less than short-term reproducibility for both software versions (coefficient of variation [CV] range from 1.3% for BMC weight to 11.0% for arm fat). Software V8.21 yielded smaller percentage mean differences between scale and DXA-estimated weights (-2.4% and -7.2% at baseline and -2.9% and -7.6% at 3 mo, respectively) and higher fat and lean weights (49.12 and 47.1 kg and 49.6 and 44.6 kg, respectively) than V8.1a. Reproducibility of all variables was comparable between software versions.

Absorptiometry, Photon↗

Bone assessment in children: comparison of fan-beam DXA analysis.

The newest version of whole body dual-energy X-ray absorptiometry (DXA) analysis software from Hologic (Discovery 12.1) is designed to enhance bone detection in smaller subjects. We re-analyzed 1127 pediatric scans (ages 1.8-18.5 yr) previously analyzed using software version 11.2. Regression analysis compared new and original results for bone area (BA), bone mineral content (BMC), bone mineral density (BMD), and DXA-derived body weight. Changes in total and regional bone results were compared with age, weight, and height. New results were highly correlated with original analyses (R2 > or = 0.9), but there were large differences at the individual subject level. The BA and BMC values increased in subjects less than 40 kg weight, resulting in a lower BMD. Original and new results were equivalent by about age 14 yr in both genders. Regional bone data showed the greatest changes in the legs. The newest software produces significant changes in bone values in subjects weighing less than 40 kg, compared with earlier versions. This effect increases with decreasing body weight. This will impact interpretation of longitudinal pediatric DXA studies, as well as existing pediatric whole body bone reference databases. Investigators must recognize which DXAsoftware version they are using, and which version produced any reference database they may use for comparison.

Absorptiometry, Photon↗

DXA scanning of acetabulum in patients with cementless total hip arthroplasty.

The aim of this study was to evaluate the reproducibility of bone mineral density (BMD) measurements of the periprosthetic bone in patients with hemispherical acetabular cups in cementless total hip arthroplasty (THA). Thirty patients were treated for primary osteoarthrosis with cementless THA. Dual-energy X-ray absorptiometry (DXA) scanning was performed with a pencil-beam bone densitometer (Norland XR-36). Accuracy and reproducibility was determined by double measurements of BMD in four regions of interest (ROI). The influence of patient postures including various pelvic inclination angles was evaluated as well. Pitman test for a combined netROI revealed a standard deviation ratio of 3.2 for the anterio-posterior scans related to the lateral position. The Wilkinson ROIs showed a high intraobserver agreement. With pelvic tilt increasing until 20 degrees , the precision of DXA scanning decreased. In conclusion, reproducibility of DXA scanning was high. This study demonstrated that the patients can be scanned in the supine position, and BMD measurement of the periacetabular bone can be performed using the Wilkinson model with four rectangular ROIs.

Absorptiometry, Photon↗

pQCT provides better prediction of canine femur breaking load than does DXA.

Our study was designed to examine the validity of dual energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) measurements as predictors of whole bone breaking strength in beagle femora. DXA was used to determine the bone mineral content, bone area, and 'areal' bone mineral density. PQCT was used to determine the cross-sectional moments of inertia, volumetric densities of the bone, and to calculate bone strength indices based on bone geometry and density. A three-point bending mechanical test was used to determine maximal load. Three variables from the pQCT data set explained 88% of the variance in maximal load, with the volumetric bone mineral density explaining 32% of the variance. The addition of the volumetric cortical density increased the adjusted r(2) to 0.601 (p=0.001) and the addition of an index created by multiplying volumetric cortical bone density by the maximum cross-sectional moment of inertia made further significant (p<0.001) improvements to an adjusted r(2) of 0.877. In comparison, when only the DXA variables were considered in a multiple regression model, areal bone mineral density was the only variable entered and explained only 51% (p<0.001) of the variance in maximal load. These results suggest that pQCT can better predict maximal load in whole beagle femora since pQCT provides information on the bone's architecture in addition to its volumetric density.

Journal Article↗

[DXA, QUS, and radiogram].

In this article, an outline of dual energy X-ray absorptiometry (DXA), quantitative ultrasound (QUS), and radiogram, and their characteristics, problems, and assessment of osteoporosis in the elderly were reviewed. It is well known that both DXA and QUS are available to risk assessment of fractures. However, because lumbar bone mineral density (BMD) is overestimated in the elderly complicated with fracture, deformity, and osteosclerotic change in the lumbar vertebra (e), some cases are unsuitable to measurement of BMD with lumbar DXA. To define vertebral fracture, visual semiquantitative and morphometric methods are used. In addition, differential diagnosis of osteoporotic vertebral fractures is necessary. Thus, to establish an exact diagnosis of osteoporosis in the elderly, it is important to understand some problems associated with the elderly.

Absorptiometry, Photon↗

[Appropriateness and limitations of bone mineral measurements by DXA (dual energy x-ray absorptiometry) in the elderly--comparison with x-ray findings].

A group of 674 (266 males and 410 females) elderly living in a rural community of Nangai Village, Akita Prefecture, were subjects of bone mineral measurements in the lumbar spine and three areas of proximal femur (femoral neck; FN, trochanter; TR and Ward's triangle; WD). Measurement was by dual energy x-ray absorptiometry (DXA) set in a mobile van during mass health examination. The purpose of this study was to verify the appropriateness and imitations in the bone mineral measurements by DXA in elderly who have other aging related abnormal calcifications such as osteophytosis in the lumbar spine and calcification of the abdominal aorta, all of which may have an influence on the 'true' value of bone mineral density (BMD) particularly in the lumbar region. The results were as follows: 1) Subjects who were not capable of being measured by DXA tended to be older and reported experiencing pain and who scored low in TMIG index of competence compared to measurable subjects. 2) BMD of 2nd-4th lumbar spine with antero-posterior projection (AP) did not show simple age-declines that are seen in younger generations. In contrast, BMDs of proximal femur show linear aging declines. 3) Analysis of the association between BMDs and osteophytosis by spondylosis deformans in the lumbar spine and calcification of the abdominal aorta in front of the lumbar spine showed that AP-BMD had a strong correlation with the grade of both spinal osteophytosis and aortic calcification. On the other hand, BMDs of proximal femur showed no significant associations with these abnormal calcifications. 4) In this context, in order to evaluate the 'true' BMD in the elderly, BMDs in the proximal femur are a more appropriate indicator than AP-BMD which may be easily contaminated by other aging-related calcification in and around the lumbar region.

Absorptiometry, Photon↗

Association between bone mineral density (DXA), body structure, and body composition in middle-aged men.

The association between bone mass, body structure, and body composition was explored in 156 men, 40 years of AGE. Bone mineral density (total body, lumbar spine, left arm, and left leg) was obtained by dual-energy X-ray absorptiometry (DXA; Hologic QDR 4500A). Body structure was determined from a battery of anthropometric dimensions with a principal components analysis. Body composition was estimated with DXA. From the 24 anthropometric dimensions, three components were extracted and identified as muscle, fat, and skeletal length. Significant correlations between the muscle component and all BMD measurements (r = 0.28-0.44) were obtained. Except for BMD of the left arm, which correlated significantly, but negatively, with the fat component (r = -0.16), no significant relations were found between the fat component and BMD. There were significant correlations between lean mass, fat mass, and BMD measurements. The correlations were higher between lean mass and BMD (r = 0.22-0.44) than between fat mass and BMD (r = 0.08-0.24). The multiple regression analysis revealed that except for BMD of the left arm only lean mass or the muscle component, and not fat mass or the fat component, were independent predictors of BMD. It is concluded that the principal anthropometric determinant of BMD in middle-aged men is lean mass or muscle.

Absorptiometry, Photon↗

Reproducibility of DXA absorptiometry: a model for bone loss estimates.

The enhanced precision of dual-energy X-ray absorptiometry (DXA) allows the detection of very small changes in bone mineral density (BMD). True clinical changes in BMD in patients must be evaluated with the appropriate error of variance. We evaluated the responsiveness of our measures to true bone loss using a statistical variance components model that characterizes the variability associated with error introduced by the machine, operator, and subjects. Our techniques were applied to data from a prospective study of BMD measurements on spine phantoms and on pre- and postmenopausal women performed on the same day or up to 4 weeks apart with DXA (QDR 1000W, Hologic). Our model determined that most of the error in measurements was introduced by operators' and subjects' variability rather than machine performance. The false-positive rates for true bone change are significantly reduced when the appropriate CV% is used to estimate the significance of bone loss over time. Our study underscores the need to use the appropriate precision error to evaluate the clinical significance of changes in bone mass in individual subjects over time.

Absorptiometry, Photon↗

Failure load of thoracic vertebrae correlates with lumbar bone mineral density measured by DXA.

Fractures of the thoracic spine account for a large portion of vertebral fractures in the elderly, yet noninvasive measurements of bone mineral properties are limited to the L2-L4 vertebral bodies. The purpose of this investigation was to determine whether bone mineral properties of the lumbar spine correlate with the failure properties of thoracic vertebrae. Cadaveric lumbar segments were scanned using dual-energy x-ray absorptiometry (DXA) from both the lateral and anteroposterior projections. Three-body segments L1-L3 and T10-T12 were then compressed to create crush fractures in the L2 and T11 vertebral bodies, and linear correlation analyses were performed to compare each DXA measure with the failure properties of L2 and T11. Lumbar BMD from the lateral view correlated significantly with T11 ultimate load (r = 0.94, P < 0.001), as did lumbar BMD from the anteroposterior projection (r = 0.83, P = 0.001). Significant correlations were also found between both lumbar BMD and BMC and the stiffness and energy to failure of T11. Furthermore, BMD and BMC measured at L2 correlated significantly with L2 ultimate load, stiffness, and energy to failure. We conclude that bone mineral properties measured at the lumbar spine provide a valid assessment of the compressive strength of both thoracic and lumbar vertebrae. Lumbar BMD may therefore be used to derive an index for the prediction of thoracolumbar fractures to aid in the early intervention of vertebral fractures.

Absorptiometry, Photon↗

Bilateral comparison of femoral bone density and hip axis length from single and fan beam DXA scans.

Dominant/nondominant differences in bone mineral density (BMD) have been observed in the upper extremities. However for the proximal femur, the distinction between dominant and nondominant hips is not clear. The purpose of this study is to evaluate left/right variations in femoral BMD and hip axis length (HAL) in both single beam and fan beam dual x-ray absorptiometry (DXA) scans. A total of 36 women aged 41-76 years (average age 60 +/- 10 years) received single beam and fan beam DXA scans of both proximal femora with a Hologic QDR-2000 scanner. Femoral BMD and hip axis length were determined for each scan. Left/right and single beam/fan beam correlations were determined and differences were evaluated using a two-way analysis of variance. Femoral BMD at corresponding measurement regions in opposing femora were highly correlated (r = 0.81-0.96). No significant left/right differences were detected. At the femoral neck, the mean BMD difference (+/- standard deviation) was 1.5% +/- 4.7% in a single beam mode and -0.6% +/- 6.3% in fan beam mode. Though mean values of femoral BMD were equivalent, the observed individual left/right differences were occasionally large (as high as 26% in the femoral neck). The hip axis length of the left and right hips were highly correlated and statistically equivalent. However, hip axis length using fan beam was significantly larger (7.5%) than the single beam measurement with a larger observed variation. We conclude that measurement of a single proximal femur will usually be sufficient for clinical evaluation of BMD and/or hip axis length.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Discrepancies in normative data between Lunar and Hologic DXA systems.

Many studies have shown the high correlation between Lunar and Hologic DXA bone mineral density (BMD) measurements despite differences in absolute calibration. However, in clinical practice, raw BMD values (in g/cm2) are not normally used for assessing skeletal status and fracture risk. Instead, the BMD values are expressed in terms of the number of standard deviations above or below the young normal value (commonly referred to as the T-score). If the normative populations of the various systems are consistent, the standard deviation scores should also be consistent. For this reason, the World Health Organization (WHO) recently established diagnostic criteria for osteoporosis based on T-scores and not BMD. However, few studies have compared the instruments in terms of their standard deviation scores. In this study, we used linear regression to compare T-scores in 83 women at L1-4 and 120 women at the femoral neck obtained on a Lunar DPX and a Hologic QDR-1000/W system. patient BMD and T-score measurements were highly correlated between the two systems (r > 0.95). No clinically significant difference in L1-4 T-scores was seen (less than 0.1 SD). However, linear regression analysis confirmed a systematic difference of 0.9 SD between the femoral neck T-scores. This discrepancy is caused by: (1) differences in the normal populations, and (2) differences in statistical models used to determine the young normal mean and standard deviation. In an attempt to correct the discrepancy, the female young normal mean and standard deviation were recalculated for the femoral neck using published epidemiological data from NHANES and existing DXA cross-calibration equations. The Hologic young normal value (mean +/- SD) was redefined as 0.85 +/- 0.11 g/cm2, while the Lunar value was redefined as 1.00 +/- 0.11 g/cm2. When the femoral neck T-scores for the study population were recalculated on the basis of these new values, the results were equivalent between manufactures, effectively eliminating the discrepancy. However, the revised values should be confirmed by additional measurements in young normal adults.

Absorptiometry, Photon↗

Two new regions of interest to evaluate separately cortical and trabecular BMD in the proximal femur using DXA.

To differentiate changes in trabecular and cortical bone density at a skeletal site bearing body weight, the main goal of this retrospective study was to develop and characterize two new regions of interest (ROIs) for DXA at the hip, one mainly focusing on trabecular bone and another mainly focusing on cortical bone. Specific aims were to maximize the precision of the ROIs and to characterize their usefulness for monitoring age-related bone loss and discriminating controls from fracture cases in a cross-sectional study population and to compare them with earlier ROIs designed by our group. The study used populations from two different previous studies conducted in our laboratory, with one comprising cohorts of healthy premenopausal women, healthy postmenopausal women, and postmenopausal osteoporotic women with at least one spinal fracture (Spine Fx Study) and the other one comprising two cohorts of age-matched postmenopausal women, in whom cases had sustained a hip fracture (Hip Fx study). The new ROI for trabecular bone (CIRCROI) tries to improve on the earlier custom-designed Central ROI, which was also targeted at trabecular bone. CIRCROI consists of an approximate largest circle that can fit inside the femoral proximal metaphysis without touching the superior and inferior endocortical walls. The new ROI for cortical bone (CORTROI) at a site bearing body weight is defined as a horizontal rectangular box crossing the femoral shaft below the lesser trochanter. CORTROI BMD cohort means were significantly higher than all other ROIs, and CIRCROI BMD cohort means were lower than standard ROIs with the exception of Ward's ROI. CIRCROI BMD was highly correlated with total femur BMD ( r=0.94) and Central BMD ( r=0.93), whereas CORTROI BMD correlations were lower (highest with total femur BMD ( r=0.86)). Fracture discrimination odds ratios (ORs) of all ROIs were significant for the Hip Fx Study, with CIRCROI BMD having the highest, and CORTROI BMD the lowest, OR (4.83 and 2.49 per SD, respectively, compared with 3.69 for Ward's ROI as the highest OR of standard ROIs). For the Spine Fx Study, only spinal and trochanteric BMD had significant OR. The new trabecular ROI had good short-term precision, comparable to the standard ROIs at the hip, but improving on that of Ward's triangle, the only standard ROI only including the anterior and posterior cortical walls and therefore more predominantly consisting of trabecular bone than other standard ROIs. The precision of the new cortical ROI was lower than standard DXA ROIs, except for Ward's triangle, but provides unique information on purely cortical bone at a skeletal site bearing body weight.

Absorptiometry, Photon↗