Development of latent fingerprints on compact disc and its effect on subsequent data recovery.

Chance fingerprints may be found on every type of surfaces of contact and when they are latent, need to be developed by various methods. The type of surface on which latent prints are to be developed is one of the important factors when a choice for a method of development is to be made. The matter becomes more crucial when the surface is unique like a compact disc containing digital data. In this case, to develop the fingerprints is not the only matter to be taken care of but also, is very important to select such a method which may not effect the stored data and its retrieval. In present investigation, various methods have been tried to develop fingerprints on the writing surface of a CD and results are discussed with respect to their development as well as its effect on stored data and data retrieval.

Charcoal↗

A self-setting single-component calcium phosphate cement.

Following an original synthesis route, we have prepared a single-component calcium phosphate apatite-like powder which settles and hardens when mixed with deionized water in an approximative 1.2 g:1 ml ratio. This paper describes the first physico-chemical studies and characterizations of the material. Observations of its in vitro behavior show a slight volume contraction and toxicity against fibroblasts bone marrow cells on disks of compacted powder. It is suggested that after an improvement of the powder characters such as grain size, and the choice of another hardening liquid, to name a few, this material should be a potential--or an ingredient of--bone cement.

Bone Cements↗

Interactive videodisc and compact disc-interactive for ophthalmic basic science and continuing medical education.

BACKGROUND: The authors designed and implemented a complete curriculum in ophthalmic pathology using IBM- and Macintosh-based interactive videodisc (IVD) technology. They also redesigned a portion of this curriculum for a new television-based platform, compact disc-interactive (CD-I). METHODS: The following issues were addressed: curriculum design, instructional design, the assembly of illustrations and the ownership of such materials, the generation of computer-based medical art and animation, and programming. The issue of academic credit for faculty participating in this effort also was considered. RESULTS: The computer-based IVD program provides the following features: (1) rapid access to thousands of high-quality illustrations with the option of superimposing graphic labels and text directly over pictures; (2) the ability to view enlargements of photographs; (3) an online glossary to view definition of terms coupled with high-quality photographs; and (4) a dynamic introduction to pathophysiology using interactive animation sequences. The authors were able to incorporate the same interactive features into the CD-I version. High-quality medical illustrations can be used effectively on the CD-I platform. CONCLUSIONS: Computer-based multimedia workstations are relatively expensive for personal use but may be useful if the equipment can be shared in a learning center or library. Compared with interactive computer-based solutions, consumer-oriented television-based technology such as CD-I is a relatively inexpensive vehicle for providing continuing medical education programs intended for use in the individual practitioner's office or home.

Compact Disks↗

Real-time, 3-dimensional echocardiography acquires all standard 2-dimensional images from 2 volume sets: a clinical demonstration in 45 patients.

To test the hypothesis that real-time, 3-dimensional (3-D) echocardiography can obtain all standard 2-dimensional (2-D) views from acquisition of 2 volume sets, we scanned 45 patients (24 men, 21 women; mean age 49 +/- 17 years). This real-time 3-D device (VOLUMETRICS Medical Imaging, Durham, NC) uses a matrix phased array transducer in a 60 degree pyramidal volume. Images are displayed as 2 steerable, intersecting, conventional 2-D image sectors that can be oriented throughout 3-D space. By using this equipment, we were able to obtain 93.3% of standard views from a parasternal volume set and 85.2% of standard views from an apical volume set. The mean scanning time was 91 +/- 19 seconds for the parasternal volume set and 86 +/- 22 seconds for the apical volume set. We conclude that standard 2-D views can be obtained in the majority of patients by using this method. This equipment has the potential to substantially decrease the imaging time compared with the standard 2-D echocardiography.

Adolescent↗

BASCD surveys and computer communication. British Association for the Study of Community Dentistry.

The British Association for the Study of Community Dentistry (BASCD) has coordinated National Health Service surveys of the dental health of school children since 1985, when Wales and parts of England were included. Scotland joined in 1987 and Northern Ireland in 1994. This series spans an interesting time in the growth of accessible technology in both statistics and medical research. The purpose of this paper is to chart the development of this data base from pen and paper via microcomputers to the Internet. The annual work now involves calibration of examiners, data collection with portable computers or by manual transcription and subsequent 'punching', paper reports passed to regional coordinators who fill in spread sheets that are passed by e-mail or through posted discs to the data coordinating centre at the Dental Health Services Research Unit at the University of Dundee. The data is checked; statistical analyses are undertaken; a paper is prepared for print and the data is deposited on the BASCD Web Site. Four operating systems and at least eight software packages are used to produce and distribute the survey results.

Adolescent↗

Integration of haemodynamic and electrocardiographic waveform data with DICOM images.

The cardiac catheterization procedure involves acquisition of haemodynamic and electrocardiographic waveforms, as well as X-ray angiographic images. The DICOM standards is being extended to address robust interchange of this waveform data together with the image data, so as to present an integrated data set for the procedure. The proposed waveform information object definition is one of the new generation of DICOM extensions, and uses controlled vocabularies and coded entry sequences to represent clinically significant aspects of the data acquisition. This enables a generic waveform object to be specialized for disparate uses, e.g., haemodynamics, electrocardiograms, phonocardiograms, and electrophysiological data.

Cardiac Catheterization↗

The DICOM review stations: are they truly different?

Digital acquisition systems are widely used nowadays. The digitization of the cath lab environment is now directed towards the change in the exchange media from an analog (i.e. cinefilm) to a digital (i.e. CD-R) medium. An important consequence of this development is the need for another type of review system. This article focuses on the replacement of the cineprojector by a digital equivalent: the DICOM review station. Since the technologies differ fundamentally, the DICOM review station has very little in common with its analog predecessor. This article explains the basics of DICOM review stations. Different approaches, both in hardware and in software, are possible, each showing their advantages and drawbacks. The impact of choices made by the industry will be illustrated by a number of commercially available DICOM review stations. Further, the article discusses the topics of diagnostic image quality and performance. In our opinion, these are the major topics when it comes to an objective comparison of the capabilities of DICOM review stations. The relation of these subjects with design choices in terms of hardware and software are discussed.

Cardiac Catheterization↗

The Kodak approach to digital cardiovascular imaging laboratories.

Cine film had been a global standard in the cardiac catheterization lab for the acquisition, archive, review and exchange for decades. The advent of digital imaging in the cath lab heightened the desire to store cath procedure images in a digital format. The issues related to the development of a digital exchange standard, the data capacities and data rates, lossless and lossy compression, and techniques to obtain digital image data from the lab are discussed. In addition, Kodak's approach to cine film replacement with digital systems is described.

Cardiac Catheterization↗

Clinical importance of the DICOM structured reporting standard.

The purpose of the DICOM Structured Reporting (SR) specification is to improve the documentation of diagnostic images and waveforms. The specification supports the interchange of expressive compound reports in which the critical features shown by images and waveforms can be denoted unambiguously by the observer, indexed, and retrieved selectively by subsequent reviewers. Findings may be expressed by the observer as: 1) text, codes, numeric measurements: 2) computer-generated coordinates of specific regions of interest within images or waveforms; or 3) reference to comparison images, sound, waveforms, curves, and previous report information. The observational and historical findings recorded by the observer may include any evidence referenced as part of an interpretation procedure. Thus, DICOM SR supports not only the reporting of diagnostic observations, but the capability to document fully the evidence that evoked the observations. This capability provides significant new opportunities for large-scale collection of structured data for clinical research, training, and outcomes assessment as a routine by-product of diagnostic image and waveform interpretation and facilitates the pooling of structured data for multi-center clinical trials and evaluations.

Cardiac Catheterization↗

Digital networking and archiving with ACOM T.O.P.

The international DICOM 3 standard for a single patient record exchange media (CD-R) provided the necessary definition for digital recording and distribution of cardiac angiographic patient data. The medical industry developed archive and review stations that allow the replacement of the 35 mm cine film. SIEMENS launched ACOM. T.O.P. in late 1995. The benefits and technical solution are presented in this paper. Today, the solution for networked real-time image data distribution within the hospital has become reality. Further integration of hemodynamic data, connectivity of hospital information systems, easy access and distribution of such high volume data from and to remote locations is well under way. ACOM. net is used as an example for the realization of commercial products to fulfill the demands of cardiologist and hospital administrators.

Cardiac Catheterization↗

The status of the GE approach to the digital catheterization laboratory.

The digital cardiac catheterization laboratory has become a reality. The cardiac catheterization community has embraced the DICOM standard as the vehicle for filmless archiving of cardiac angiographic studies. General Electric Medical Systems (GE) provides a completely scaleable offering for filmless archiving with the GEMnet product line. The GEMnet philosophy: practicality, scaleability, reliability and upgradeability. Practicality is conforming to standards. Standards in imaging data format and communications. Scaleability of a system configuration maximizes the dollar spent to match the right system to the patient volume of a department. Reliability is a fault tolerant design, redundancy of data to insure system up-time and advanced system diagnostics to speed service time. Upgradeability is keeping pace with the evoluation of new technologies to take advantage of increases in performance and reductions in price.

Cardiac Catheterization↗

Centrifugal and electric field forces dual-pumping CD-like microfluidic platform for biomedical separation.

In this article, we propose a versatile CD-like multi-channel electrophoresis-based biomedical separation system that is driven by the interactive forces between the centrifugal force and the electric field force. The centrifugal force control of this system is realized through the velocity control of a DC servo motor, while the electric field is governed through the concentric conducting circuits, which are suitably designed and fabricated by sputtering on metal mask method, and can be adjusted to provide multi-stage voltages. Experimental results demonstrate that the electro-osmotic flow (EOF) effect can be effectively reduced when the electric field force and centrifugal force are in the opposite direction. Benefits from this are that the electrophoresis separation time can be prolonged and the length of the microfluidic channels can be shortened; therefore, more effective separation efficiency can be obtained. Moreover, other advantages, such as lower joule-heat generation, low-chemistry reaction, and no variation on the ion concentration during processes, make this biomedical separation system more useful.

Biopolymers↗

Identification of endothelial proteins by MALDI-MS using a compact disc microfluidic system.

Vascular endothelial proteins have been analyzed using two-dimensional (2D) gel electrophoresis and subsequent mass spectrometry, with separate methods for the intervening sample preparations. Compact disc (CD) technology was found to be rapid, giving high overall yield both with ordinary Coomassie staining and with Sypro Ruby staining. Combined with automatic in-gel digestion, the CD technology has great capacity for large numbers of protein analysis, although for limited sample numbers, manual methods can give similar sequence coverage. In a test set of 48 samples, 45 proteins were identified using the CD preparation technique, 32 identified with higher sequence coverage using the CD technique, 7 with higher using ZipTips in a robotic workstation, and 5 with higher coverage using dried droplets of unpurified samples. In the process of these methodological comparisons, basic patterns for 116 endothelial proteins were defined, representing 297 separate protein spots on the 2D gels.

Compact Disks↗

New chemistry on old CDs.

Old compact discs (CDs) have been found to be useful for modern chemical research. Their metal reflective film is suitable for the preparation of high-quality self-assembled monolayers (SAMs) and for electrochemical analysis; pre-grooved polycarbonate base is ideal for the "customized" fabrication of material micro/nanostructures; and the immobilization of biomolecules on CDs, in conjunction with a conventional CD drive, promises to be an inexpensive tool for point-of-care biomedical diagnosis and gene analysis.

Biosensing Techniques↗