Nonpenetrating vascular clips for small-caliber anastomosis.

In the search for better anastomosing techniques, an improved vascular stapler device (VCS clip applier system(R)) has been introduced. The system uses nonpenetrating clips to approximate everted vessel walls. The objective of this study was to determine the effects of nonpenetrating vascular clips on endothelial wound healing. Aortic end-to-end anastomoses were performed in male Wistar rats. A comparison was made between clipped (n = 12) and conventional hand-sewn (n = 6) anastomoses. Patency rates were verified at different time intervals (after 1, 4, and 8 weeks), after which the anastomotic sites were removed. Morphological evaluation was carried out using scanning electron microscopy. All rats survived the procedure. Closure with clips took less time than closure with conventional sutures, with decreasing aortic clamping times for the clipped procedures during the course of the experiments. Patency rates were 100% in both the "clipped" and "sutured" groups. Microscopic examination showed favorable endothelial healing at the clipped anastomotic sites, with less inflammatory reaction at 1 week, and a more complete endothelial regeneration at 4 and 8 weeks follow-up, as compared with the sutured anastomoses. The clip applier holds the promise of a useful device in anastomosing small-caliber vessels, since clip closure takes less time than suturing, while patency rates are identical, and morphological results are favorable. Training is mandatory to obtain technical skills and to achieve optimal results.

Anastomosis, Surgical↗

Clinical safety and performance of Sugita titanium aneurysm clips.

BACKGROUND: In spite of advantages for neuro-imaging, titanium aneurysm clips are not yet chosen for routine use for clipping of intracranial aneurysms, probably because their reliability has not been demonstrated in large numbers of cases. We assess reliability and safety of Sugita titanium aneurysm clips for routine clinical use in a large number of operated cases. METHOD: Intra-operative performance and safety of Sugita titanium aneurysm clips were evaluated in 347 patients in our institutions. Aneurysms in 261 patients had ruptured: 86 patients had unruptured aneurysms. RESULTS: A total of 441 clips of 52 different types were used. No early or delayed complications occurred in relation to the titianium clips, such as deformity or slippage of a clip. Patient outcome according to the Glasgow Outcome Scale was similar to that when conventional cobalt-based aneurysm clips were used. INTERPRETATION: Reliability and safety of Sugita aneurysm clips were demonstrated in a large number of patients. The clips are suitable for routine use in aneurysm surgery.

Adult↗

Spring clip for aneurysm surgery.

This report concerns a clip for aneurysm surgery which has (a) a stabilizing wire that prevents the scissoring of the blades, (b) a stronger coil spring that allows longer blades and a reduced possibility of slippage, and (c) grasping sites that allow the clip to be positioned in both an applier that holds the clip rigidly in one position, and in one that allows the clip to be rotated for optimal placement. The clip is made from stainless-steel wire 2 mm in diameter, which is larger than that used for other clips. The 2-mm diameter permits the clip to have wider clamping surfaces than other clips made from wire, it permits the grasping sites to be notched so that it may be held in a rotating clip applier, and permits the clip to be tooled for a stronger coil spring. The coil springs are of either a standard or a strong tension, and have opening pressures of approximately 175 g and 320 g, respectively.

Aneurysm↗

Neurosurgical vascular complications associated with aneurysm clips evaluated by postmortem angiography.

Neurosurgical vascular complications were evaluated by postmortem angiography in a consecutive prospective series of 63 patients in Helsinki who suffered a fatal outcome following neurosurgery for ruptured intracranial aneurysm. Operative vascular complications were revealed in 28 (44%) of the cases. Massive intraoperative bleeding resulting from rupture of the aneurysm or adjacent major artery during dissection or clip application complicated the operation in 16 (25%) patients. Clip-induced obstruction of cerebral arteries was detected by angiography in seven cases (11%). In six of the patients an adjacent cerebral vessel was accidentally clipped. In one case a kinking of the clip had caused obstruction of the right anterior cerebellar artery with resulting frontal infarct. A combination of rupture of the internal carotid artery and accidental ligation of the left posterior cerebellar artery occurring simultaneously during the clipping of a ruptured basilar aneurysm was detected in one patient (2%). Other types of complication were revealed in four cases (6%): detachment of clip with re-bleeding; clipping of an uninvolved aneurysm instead of the ruptured one; displacement of the clip beneath the ruptured aneurysm. Operations on ruptured basilar artery aneurysm were significantly (P less than 0.01) more prone to complications. The results indicate that operative vascular complications play a significant role in the mortality of aneurysm patients. Post-mortem angiographic technique with contrast medium that vulcanizes at room temperature is particularly suitable for demonstration of the haemodynamic significance of clip-induced cerebrovascular accidental occlusions, and is the only method at autopsy to reveal an occlusion caused by a kinking of a properly placed aneurysm clip.

Adult↗

Modified CLIP using PIVKA-II for evaluating prognosis after hepatectomy for hepatocellular carcinoma.

AIMS: The new staging system proposed by the Cancer of the Liver Italian Program (CLIP) for hepatocellular carcinoma (HCC) accounts for both liver dysfunction and tumour characteristics. The present study was designed to analyze UICC TNM stage, CLIP and modified CLIP in 91 patients who underwent hepatic resection for HCC. METHODS: In the modified CLIP, scoring of AFP was replaced by that of protein induced by vitamin K absence or antagonist II (PIVKA-II; predictive value, > or = 400 mAU/ml). RESULTS: After hepatic resection, 54 patients developed recurrent tumours. High PIVKA-II was a significant determinant of recurrence (p<0.05). However, a high score of the modified CLIP as well as those other staging systems did not correlate with tumour-recurrence rate. Univariate analysis showed that high TNM score, CLIP score and our modified CLIP score were significant predictors of poor prognosis. Multivariate Cox's analysis revealed that high PIVKA-II and high modified CLIP score were associated with higher risk for disease-free and overall survival as well as high TNM stage. CONCLUSIONS: Compared with the original CLIP, our modified CLIP was a better predictor of prognosis of HCC patients who underwent hepatic resection.

Adult↗

Two randomized controlled trials comparing the Hulka and Filshie Clips for tubal sterilization.

To compare the effectiveness and safety of the Filshie Clip System and Hulka Clip System when applied via minilaparotomy and laparoscopy, we conducted 2 multicenter randomized controlled trials of 2126 women (878 in the minilaparotomy study and 1248 in the laparoscopy study) who received either the Filshie or Hulka Clip. A physician other than the operator evaluated patients postoperatively and again at 1, 6, and 12 months after surgery. We compared the cumulative incidence of pregnancy and the frequency of safety related events for the device groups. Twenty-four month follow-up was planned for a subset of 599 women in the laparoscopy study. One woman who received the Filshie Clip and 6 women who received the Hulka Clip became pregnant within one year. The 12-month life-table pregnancy probability was 1.1 per 1000 women in the Filshie Clip group and 6.9 per 1000 women in the Hulka Clip group. The difference in the risk of pregnancy through 12 months between device groups neared statistical significance (p = 0.06). Among the extended follow-up subset, the 12- and 24-month cumulative pregnancy probabilities were 3.9 and 9.7 per 1000 women for the Filshie Clip group and 11.7 and 28.1 per 1000 women for the Hulka Clip group (p = 0.16 for comparison through 24 months). Both the Filshie and Hulka Clips are effective and safe for use in tubal occlusion.

Female↗

Divided renal and caval vein plasma renin activity in two-kidney two-clip hypertension in rabbits and variations of blood pressure, plasma volume and renal function following unilateral nephrectomy.

Determinations were made of peripheral plasma renin activity, blood pressure, plasma volume and blood urea nitrogen in rabbit models of two-kidney one-clip, two-kidney two-clip or one-kidney one-clip hypertension that were created by staged operation to produce functionally significant renal artery stenosis. The plasma renin activity in the divided renal veins and inferior caval vein was also measured in animals with two-kidney two-clip hypertension. In rabbits with two-kidney two-clip hypertension the plasma renin activity was significantly higher in the renal vein on the more involved side and comparable in the renal vein on the less involved side and the inferior caval vein. This response pattern of renin secretion, unilateral hypersecretion with contralateral suppression, was identical with that observed in animals with two-kidney one-clip hypertension. In animals with one-kidney one-clip hypertension there was a marked increase in plasma volume and blood urea nitrogen. The renovascular hypertension was in decreasing order of severity in animals with one-kidney one-clip hypertension, those with two-kidney two-clip hypertension and those with two-kidney one-clip hypertension.

Animals↗

A combination of wrapping and clipping using a collagen-impregnated dacron fabric (Hemashield).

BACKGROUND: We describe techniques combining wrapping and clipping using a collagen-impregnated Dacron knitted fabric (Hemashield) for accidental arterial perforations and broad-based aneurysms. The results of these techniques in seven patients are presented. METHODS: Clip-reinforced wrapping was performed to obtain hemostasis in two patients with arterial perforations and in a patient with a ruptured broad-based aneurysm in the internal carotid artery. Clipping of the broad neck of the aneurysm and wrapping with Hemashield (wrap-clipping) was performed in four patients with unruptured aneurysms (one internal carotid artery, two middle cerebral artery, one basilar artery). RESULTS: In the three patients treated with clip-reinforced wrapping, complete hemostasis was obtained just after clip application. In the patient with a ruptured broad-based aneurysm, postoperative angiography demonstrated that the dome of the aneurysm was well compressed. In the four patients treated with wrap-clipping, postoperative angiography revealed successful clipping of the broad neck of the aneurysm. CONCLUSION: In this early experience, there were no problems in the use of Hemashield for clip-reinforced wrapping or wrap-clipping.

Aged↗

Cloning and expression of chicken CLIP-170 and restin isoforms.

We have cloned cDNA for the chicken homologues of human CLIP-170 and Restin and characterized expression of chicken CLIP-170 and Restin messages in a variety of chicken tissues. Chicken CLIP-170 and Restin, like the human homologues, differ only in a stretch of 35 amino acids present in Restin but missing from CLIP-170. This Restin-specific insert is perfectly conserved between the chicken and human sequences at both the protein and nucleotide level and contributes an additional five heptads to one of the heptad repeat regions in the central alpha-helical coiled-coil rod domain. Other highly conserved chicken and human CLIP-170/Restin regions confirm the importance of certain protein domains as crucial for protein function, including two CAP-Gly microtubule-binding motifs in the N-terminal globular head domain and two CCHC metal-binding motifs in the C-terminal globular tail domain. We have used Southern DNA blot analysis and PCR amplification of exon-intron junctions of chicken genomic DNA to confirm that CLIP-170 and Restin are isoforms encoded by the same gene. Semiquantitative RT-PCR analysis of CLIP-170 and Restin mRNA expression revealed expression of both isoforms in a variety of chicken tissues but in different ratios. In the tissues tested, except brain, the message for CLIP-170 was more abundant than that for Restin. Comparison of the levels of CLIP-170 and Restin messages in RNA from chicken and human intestinal epithelial cells revealed remarkably similar ratios in the two species. Our data suggest that expression of CLIP-170 and Restin is differentially regulated and that the two isoforms have distinct functions in a wide variety of cells.

Alternative Splicing↗

Clinical experience with non-penetrating vascular clips in free-flap reconstructions.

To date, the gold standard for performing a microvascular anastomosis has been the penetrating suture with attached needle. During the last two decades, non-penetrating techniques have been introduced, including the Unilink system for end-to-end anastomoses, and the VCS clip-applier system for both end-to-end and end-to-side anastomoses. The aim of this study was to compare the results of different techniques used to create microvascular anastomoses in free-flap reconstructions. Between January 1995 and October 1999, we performed 474 microvascular anastomoses in 216 consecutive free-tissue transfers. The anastomosis techniques included manual sutures (42%), Unilink rings (34%) and VCS clips (24%). Seven combined sutured-clipped anastomoses were excluded from further analysis. The mean anastomotic time when rings were applied was significantly shorter than when using clips (P 0.0001) or sutures (P 0.0001). Venous anastomoses using clips took less time than those using sutures (P 0.05). There were 19 anastomotic failures, all of which lead to early flap failure. Ten flaps were salvaged by early reoperation; nine flaps were lost. Three more flaps were lost as a result of other causes, bringing the flap survival rate down to 94.4%. Early flap failure was caused by failure of the arterial anastomosis in eight cases; all of them were sutured (these represented 5% of all arterial anastomoses with sutures). None of the clipped arterial anastomoses failed. Early flap failure was caused by failure of the venous anastomosis in 11 patients. Three of these anastomoses were sutured (representing 6% of all venous anastomoses with sutures), seven were anastomosed with rings (representing 5% of all venous anastomoses with rings) and one was clipped (representing 2% of all venous anastomoses with clips). Both the VCS clip-applier system and the Unilink system are easy to handle and allow fast microvascular anastomoses without intraluminal penetration. The patency rate of clipped vessels is at least as good as the patency rates of vessels anastomosed using sutures or rings.

Adolescent↗

"Hemodynamic efficacy" of two endoscopic clip devices used in the treatment of bleeding vessels, tested in an experimental setting using the compact Erlangen Active Simulator for Interventional Endoscopy (compactEASIE) training model.

BACKGROUND AND STUDY AIMS: Hemoclip therapy is a well-established procedure in the treatment of gastrointestinal bleeding. Although new products are provided periodically by the industry, comparative investigations are lacking. We compared two different hemoclip devices in an experimental setting, assessing them using objective hemostatic parameters. MATERIALS AND METHODS: We compared two disposable clip devices (Olympus HX-200L-135 (n = 40) vs. Wilson-Cook Tri-Clip (n = 40)) in an experimental setting using the compact Erlangen Active Simulator for Interventional Endoscopy (compactEASIE) training model equipped with an upper gastrointestinal-organ package for bleeding simulation. This was a randomized, prospective, controlled trial. Four investigators with different levels of endoscopic experience applied ten hemoclip devices of each type to the spurting vessels, the clips allocated using a randomized list for each investigator. The efficacy of hemostasis was determined by continuous measurement of the pressure within the afferent vessel before and after clip application and calculation of the relative reduction of vessel diameter by the clip device. The system pressure was recorded over the period from 1 minute before to 1 minute after clip application. A secondary end point was a subjective assessment of the whole clip application procedure by the endoscopist and the assisting nurse, using a visual analog scale (0 - 100, with 100 representing the best experience). RESULTS: A total of 39/40 clips of each type were applied successfully. Both clip devices led to a significant increase in system pressure, representing significant relative reduction of vessel diameter (Olympus 5.4 +/- 7.5 %, p < 0.001; Cook 4.9 +/- 8.0 %, p < 0.001). Overall, there was no significant difference between the two devices ( P = 0.756). However, the investigator with the least experience in endoscopy (< 100 procedures) produced significantly inferior results compared with the other three investigators, who had performed between 2000 and 6000 procedures each ( P < 0.05). We found no evidence of a learning curve from the intra-observer results. The devices received good, but not significantly different, overall ratings by the endoscopists (Olympus 69 +/- 24 vs. Wilson-Cook 65 +/- 16) and by the assisting nurses (Olympus 77 +/- 9 vs. Wilson-Cook 70 +/- 22). CONCLUSIONS: Using an established cadaveric training model, no significant difference was found between the two types of hemoclip devices with respect to their "hemostatic efficacy". However, the experience of the endoscopist appears to play a major role in successful clip application. The use of a feedback mechanism in emergency endoscopy training, using continuous intravessel pressure monitoring, may substantially enhance the efficacy of training, resulting in a similar improvement in clinical results.

Cadaver↗

Structural features of the invariant chain fragment CLIP controlling rapid release from HLA-DR molecules and inhibition of peptide binding.

The invariant chain (Ii) prevents binding of ligands to major histocompatibility complex (MHC) class II molecules in the endoplasmic reticulum and during intracellular transport. Stepwise removal of the Ii in a trans-Golgi compartment renders MHC class II molecules accessible for peptide loading, with CLIP (class II-associated Ii peptides) as the final fragment to be released. Here we show that CLIP can be subdivided into distinct functional regions. The C-terminal segment (residues 92-105) of the CLIP-(81-105) fragment mediates inhibition of self- and antigenic peptide binding to HLA-DR2 molecules. In contrast, the N-terminal segment CLIP-(81-98) binds to the Staphylococcus aureus enterotoxin B contact site outside the peptide-binding groove on the alpha 1 domain and does not interfere with peptide binding. Its functional significance appears to lie in the contribution to CLIP removal: the dissociation of CLIP-(81-105) is characterized by a fast off-rate, which is accelerated at endosomal pH, whereas in the absence of the N-terminal CLIP-(81-91), the off-rate of C-terminal CLIP-(92-105) is slow and remains unaltered at low pH. Mechanistically, the N-terminal segment of CLIP seems to prevent tight interactions of CLIP side chains with specificity pockets in the peptide-binding groove that normally occurs during maturation of long-lived class II-peptide complexes.

Amino Acid Sequence↗

Purification and analysis of authentic CLIP-170 and recombinant fragments.

We have purified authentic CLIP-170 (cytoplasmic linker protein of 170 kDa) and fragments comprising functional domains of the protein to characterize the structural basis of the function of CLIP-170. Analysis of authentic CLIP-170 and the recombinant fragments by electron microscopy after glycerol spraying/low angle rotary metal shadowing reveals CLIP-170 as a thin, 135-nm-long molecule with two kinks in its central rod domain, which are approximately equally spaced from the two ends of the protein. The central domain consisting of heptad repeats, which is alpha-helical in nature and forms a 2-stranded coiled-coil, mediates dimerization of CLIP-170. The rod domain harbors two kinks, each spaced approximately 37 nm from the corresponding end of the molecule, thus providing mechanical flexibility to the highly elongated molecule. The N-terminal domain of CLIP-170 binds to microtubules in vitro with a stoichiometry of one dimeric head domain per four tubulin heterodimers. Authentic CLIP-170 binds to microtubules with lower stoichiometry, indicating that the rod and tail domains affect microtubule binding of CLIP-170. These results document that CLIP-170 is a highly elongated polar molecule with the microtubule-binding domain and the organelle-interacting domains at opposite ends of the homodimer, thus providing a structural basis for the function of CLIP-170 as a microtubule-organelle linker protein.

Binding Sites↗

Conformational changes in CLIP-170 regulate its binding to microtubules and dynactin localization.

Cytoplasmic linker protein (CLIP)-170, CLIP-115, and the dynactin subunit p150(Glued) are structurally related proteins, which associate specifically with the ends of growing microtubules (MTs). Here, we show that down-regulation of CLIP-170 by RNA interference results in a strongly reduced accumulation of dynactin at the MT tips. The NH(2) terminus of p150(Glued) binds directly to the COOH terminus of CLIP-170 through its second metal-binding motif. p150(Glued) and LIS1, a dynein-associating protein, compete for the interaction with the CLIP-170 COOH terminus, suggesting that LIS1 can act to release dynactin from the MT tips. We also show that the NH(2)-terminal part of CLIP-170 itself associates with the CLIP-170 COOH terminus through its first metal-binding motif. By using scanning force microscopy and fluorescence resonance energy transfer-based experiments we provide evidence for an intramolecular interaction between the NH(2) and COOH termini of CLIP-170. This interaction interferes with the binding of the CLIP-170 to MTs. We propose that conformational changes in CLIP-170 are important for binding to dynactin, LIS1, and the MT tips.

Amino Acid Motifs↗

Laparoscopic cholecystectomy: retrospective comparative evaluation of titanium versus absorbable clips.

We present a retrospective study of the use of titanium and absorbable clips during laparoscopic cholecystectomy. The aim was to determine any differences in outcome and costs. From January 1999 to February 2002, 690 patients who had successfully undergone a laparoscopic cholecystectomy were reviewed. According to the type of clip, we retrospectively identified two groups of patients: 199 in whom the surgeons had used absorbable clips (absorbable clip group, ACG) and 491 in whom the surgeons had used titanium nonabsorbable clips (titanium clip group, TCG). Data about demographics, operation, results, complications, and follow-up were collected and matched in the two groups. Demographics, concomitant surgery, and the American Society of Anesthesiologists (ASA) status were comparable between the two groups. Although the proportions of cases requiring urgent operation, intraoperative cholangiography, use of a fourth trocar, and use of drainage suction were similar, the difficulty score of the operation was lower (6.3 vs. 7.0, P =.03) and the operative time was shorter (44 vs. 61 minutes, P <.0001) in the ACG than in the TCG. Complications, hospital stay, and long-term results were satisfactory and comparable between the two groups. No correlation was found between clip type and the incidence of biliary tree injuries, bleeding, wound infection, or readmission. The cost of the two types of clips varied slightly (90 euros for each procedure). Despite the fact that absorbable clips are theoretically less likely to cause complications than metallic ones, we were not able to demonstrate any clinical advantage during laparoscopic cholecystectomy in this retrospective study. Furthermore, the results suggest that absorbable clips are preferred when the cholecystectomy presents fewer difficulties.

Adult↗

Comparison of nonabsorbable polymer ligating and standard titanium clips with and without a vascular cuff.

PURPOSE: To compare the efficacy of nonabsorbable polymer ligating (NPL) and titanium clips applied with and without a 1-mm vascular cuff at physiologic and supraphysiologic pressures. MATERIALS AND METHODS: An in vitro equine-vessel model was created to test clip occlusion strength. Ten-millimeter NPL and standard Ti clips were applied to veins (10 mm) and arteries (10, 6, and 5 mm) with and without a 1-mm cuff and tested until they held a pressure of 300 mm Hg (veins) or 760 mm Hg (arteries) for 2 minutes or leaked. RESULTS: The NPL clip was statistically more secure on 10-mm veins with and without a cuff, 10-mm arteries with and without a cuff, and 6-mm arteries with a cuff than was the Ti clip. Leaving a 1-mm cuff resulted in a statistically higher leak point in all vessels tested except the 6-mm arteries secured with the Ti clip. CONCLUSIONS: The NPL clip was more secure than the Ti clip on larger arteries and veins. A 1-mm vascular cuff enhances the security of both NPL and Ti clips in vessels of all sizes. The NPL clip is secure and reliable in securing both arteries and veins.

Animals↗

The FKBP12-rapamycin-associated protein (FRAP) is a CLIP-170 kinase.

CLIP-170/Restin belongs to a family of conserved microtubule (MT)-associated proteins, which are important for MT organization and functions. CLIP-170 is a phosphoprotein and phosphorylation is thought to regulate the binding of CLIP-170 to MTs. However, little is known about the kinase(s) involved. In this study, we show that FKBP12-rapamycin-associated protein (FRAP, also called mTOR/RAFT) interacts with CLIP-170. CLIP-170 is phosphorylated in vivo at multiple sites, including rapamycin-sensitive and -insensitive sites, and is phosphorylated by FRAP in vitro at the rapamycin-sensitive sites. In addition, rapamycin inhibited the ability of CLIP-170 to bind to MTs. Our observations suggest that multiple CLIP-170 kinases are involved in positive and negative control of CLIP-170, and FRAP is a CLIP-170 kinase positively regulating the MT-binding behavior of CLIP-170.

Animals↗

The functional role of class II-associated invariant chain peptide (CLIP) in its ability to variably modulate immune responses.

During the process of class II MHC assembly and cell surface expression, the class II-associated invariant chain peptide (CLIP) is removed from the peptide-binding groove of MHC, a task mediated by H-2M. This allows binding and presentation of peptide epitopes. We have previously shown that exogenously added CLIP interferes with this process and down-regulates the cell surface expression of class II molecules. In this study, we explored the effect of exogenously added CLIP on antigen-specific immune responses. In vivo studies with CLIP and various peptide and protein antigens with different affinities for I-A(d) molecules demonstrated that CLIP variably affects the T cell-mediated immune responses. Immunization with CLIP along with the antigen induced a shift from a T(h)1- to T(h)2-like response as determined by the cytokine profile and antibody isotype. These results suggest that the presence of exogenous CLIP can significantly influence the presentation of antigen by class II MHC molecules to CD4 T cells and thereby modulate immune responses. Exogenously added CLIP rapidly localized into the subcellular compartment of antigen-presenting cells where MHC class II molecules are present. We suggest that exogenous CLIP reduces the loading of peptides on the class II molecules, thus down-regulating MHC-peptide complexes on the cell surface. Alternatively, CLIP may bind to cell surface class II molecules and this complex is rapidly internalized resulting in reduced cell surface MHC class II expression. The reduced level of MHC-peptide complexes favors the activation of T(h)2 cells over T(h)1 cells. These results have implications in the regulation of immune responses, particularly the prevention of certain autoimmune diseases where T(h)1-type responses are pathogenic and T(h)2-type responses are protective.