Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “BLOOD”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Ethyleneglycol-bis-(beta-aminoethylether)tetraacetate as a blood anticoagulant: preservation of antigen-presenting cell function and antigen-specific proliferative response of peripheral blood mononuclear cells from stored blood.

We examined the progressive and irreversible loss of antigen-specific lymphoproliferative responses in peripheral blood mononuclear cells (PBMC) obtained from blood exposed for prolonged periods to EDTA as an anticoagulant. The responses of these lymphocytes to interleukin-2 or to concanavalin A were, however, unaffected. The observed loss was not due to depletion of metal ions by EDTA, since the addition of several divalent cations to whole blood during storage in EDTA or to lymphocytes from EDTA-stored blood during antigen stimulation in vitro did not alleviate the defect. Reconstitution of antigen-specific T-cell lines or Percoll-purified T cells with adherent antigen-presenting cells in antigen stimulation assays revealed that the presenting cells and not the effector T-cells were the targets of EDTA-mediated damage. The anticoagulant heparin helped to circumvent this problem. Surprisingly, EGTA, another metal ion chelator, could successfully replace EDTA, with a marginal loss in antigen-specific responses. Lymphoproliferative responses to antigens of Japanese encephalitis virus (JEV) and Mycobacterium tuberculosis were both significantly preserved in EGTA. JEV antigen-specific responses of PBMC obtained from the blood of convalescent JEV patients and stored in EGTA for as long as 24 h (n = 20) were comparable to those of fresh PBMC (n = 10), while PBMC from blood stored in EDTA (n = 17) for 16 h or longer failed to respond. We recommend that EGTA be used as the anticoagulant of choice for applications that require the lymphocyte proliferation assay, especially when on-site testing facilities are not available.

Antigen Presentation↗

Controlled comparison of the BACTEC high-blood-volume fungal medium, BACTEC Plus 26 aerobic blood culture bottle, and 10-milliliter isolator blood culture system for detection of fungemia and bacteremia.

The BACTEC high-blood-volume fungal medium (HBV-FM) (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with the Isolator (IS) tube and the BACTEC Plus 26 (BP26) blood culture bottle for the ability to recover fungi from the blood of adult patients suspected of having fungemia. A total of 6,836 blood culture sets that fulfilled criteria for inclusion in the study were received. Three separate comparisons were performed: 4,907 HBV-FM versus IS, 4,886 BP26 versus HBV-FM, and 4,949 BP26 versus IS. For the HBV-FM versus IS comparison, 218 isolates were recovered: 125 (57.3%) were bacteria and 93 (42.7%) were fungi. HBV-FM was comparable to IS for recovery of yeasts, but IS was superior for recovery of Histoplasma capsulatum (25 versus 0 isolates recovered [P < 0.001]). Growth of Torulopsis glabrata was detected earlier (P < 0.05) in HBV-FM bottles. For the BP26 versus HBV-FM comparison, 229 isolates were recovered: 161 (70.3%) were bacteria, and 68 (29.7%) were fungi. HBV-FM was superior for recovery of T. glabrata (P < 0.025) and all fungi combined (P < 0.025). There were no statistically significant differences in the speed of detection of microbial growth. For the BP26 versus IS comparison, 251 isolates were recovered: 165 (65.7%) were bacteria, and 86 (34.2%) were fungi. IS was superior for recovery of H. capsulatum (P < 0.001), T. glabrata (P < 0.05), and fungi other than H. capsulatum (P < 0.025). BP26 was superior for recovery of all bacteria combined (P < 0.001) and viridans group streptococci (P < 0.01). Growth of T. glabrata (P < 0.05) was detected earlier in IS tubes. Growth of Staphylococcus aureus (P < 0.01), viridans group streptococci (P < 0.01), Pseudomonas aeruginosa (P < 0.05), and all microorganisms combined (P < 0.05) was detected earlier in BP26 bottles. For yeast, 57 of 59 (96.6%), 79 of 80 (98.7%), and 64 of 67(95.5%) were recovered from BP26 bottles, HBV-FM bottles, and IS tubes, respectively, by day 14; for H. capsulatum, 14 of 36 (38%) isolates were recovered from IS tubes by day 14. Mean times of recovery were similar for BACTEC bottles and IS. We conclude that (i) for recovery of fungi from blood cultures, HBV-FM is equivalent to IS (with the exception of H. capsulatum); (ii) for recovery of bacteria, BP26 is superior to IS; (iii) BP26 bottles are inferior to both HBV-FM bottles and IS tubes for recovery of T. glabrata; and (iv) HBV-FM bottles must be paired with another blood culture bottle or system to optimize detection of bacteremia.

Aerobiosis↗

Correlation of flow probe determinations of common carotid artery blood flow and internal carotid artery blood flow with microsphere determinations of cerebral blood flow in piglets.

We investigated whether blood flow determined by a flow probe situated on one common carotid artery provided an accurate estimation of unilateral cerebral blood flow (CBF) in piglets. In eight anesthetized, mechanically ventilated piglets, blood flow determined by an ultrasonic flow probe placed on the right common carotid artery was correlated with CBF determined by microspheres under two experimental conditions: 1) before ligation of the right external carotid artery with both the right external and internal carotid circulations intact [common carotid artery blood flow (CCABF) condition], and 2) after ligation of the right external carotid artery (ipsilateral to the flow probe) with all residual right-sided carotid artery blood flow directed through the right internal carotid artery [internal carotid artery blood flow (ICABF) condition]. The left carotid artery was not manipulated in any way in either protocol. Independent correlations of unilateral CCABF and ICABF with microsphere-determined unilateral CBF were highly significant over a 5-fold range of CBF induced by hypercarbia or hypoxia (r = 0.94 and 0.92, respectively; both p < 0.001). The slope of the correlation of unilateral CCABF versus unilateral CBF was 1.68 +/- 0.19 (SEM), suggesting that CCABF overestimated CBF by 68%. The slope of the correlation of unilateral ICABF versus unilateral CBF did not differ significantly from unity (1.06 +/- 0.15), and the y intercept did not differ significantly from zero [-1.3 +/- 5.2 (SEM) mL]. Consequently, unilateral ICABF determined by flow probe accurately reflected unilateral CBF determined by microspheres under these conditions. Flow probe assessments of CCABF and ICABF in piglets may provide information about dynamic aspects of vascular control in the cerebral circulation that has heretofore been unavailable.

Animals↗

[Measurement of cerebral blood flow the blood sampling method using 99mTc-ECD: simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera].

To measure regional cerebral blood flow (rCBF) by blood sampling using 99mTc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using 99mTc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application.

Blood Specimen Collection↗

[A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (Part 2): A study of time correction of one-point blood sample count].

In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised our method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step.

Adult↗

[Blood pressure in the extra-organ vessels and tissue blood flow in spleen in acute dose-related blood loss and perftoran application].

In experiment on dogs, using antitensiometric and histological investigations, there were shown, that before the blood loss an average blood pressure (BP) in a. femoralis (AF) is higher than in a. lienalis (AL), initial systolic BP in a. renalis (AR) is higher, than average BP in AF. After an acute dosated blood loss (DBL) occurrence of 40% of the circulating blood volume there was noted lowering of BP in AL by 6 times in comparison with that in AF. Lowering of BP in AR had leaved behind that in AF by 3 times. While the pulse BP lowering by 97.2%, in comparison with initial one, the blood stasis in AR had occurred. The perftoran application had promoted the restoration of average BP in AF up to 98.3% from the initial one and the pulse BP in AL raising--by 85%, the tissue blood flow in spleen--by 72.1%.

Acute Disease↗

[Blood stream infection and blood culture--"progress" and "blind" in blood culture testing].

We have investigated various types of blood culture bottles which are mainly used at present and posed problems present in the blood culture bottles. First, there are differences between resin and ecosorb in the ability to adsorb and inactivate antibiotics in the blood. Second, the delay in placing the bottle (into which blood was inoculated) to the automatic instrument (delay in the start of incubation) greatly affects the automatic detection by BACTEC system and shows false negatives. Third, when the same blood is incubated in plural bottles (aerobic and anaerobic bottles), the differences among the detected organisms in the number are comparatively high, i.e., about 40%. In addition, there are differences among the organisms in the number of days required for the detection of the organisms. In this case, the detected organisms are clearly different in many cases. The technology of blood culture has been progressed remarkably. However, the efficiency of utilization of automatic instruments for diagnosis of infection depends greatly on the ability of laboratory technicians.

Bacteriological Techniques↗

[Cerebral blood flow in infants: comparison of carotid blood flow and cerebral blood velocity].

Carotid blood was measured with a ultrasonic volume flow meter in 38 infants. The carotid blood flow was 1.50 +/- 0.55 ml/sec. At the same time peak systolic flow velocity, mean blood velocity, end diastolic velocity, pulsatility index (PI) and resistance index (RI) in the middle and anterior cerebral arteries were measured by duplex Doppler scanning. There was a correlation between the carotid blood flow and the mean blood velocity in middle and anterior cerebral arteries. However, PI and RI were not well correlated with carotid blood flow.

Blood Flow Velocity↗

[Determination of blood alcohol in persons with blood diseases and secondary distrubances of the blood pictures].

The distribution of alcohol in the blood is determined by the water content of serum and whole blood. In order to verify the conversion factor qu for the establishment of the "blood alcohol concentration" from the alcohol content of the serum, the serum protein content, the hematocrit and the water content of the serum and whole blood were determined in 246 persons suffering from diseases in which disturbances of the water content of the blood could be expected. It was shown that the conversion factor of 1,20 used in the routine practice of the alcohol laboratory is too large. Calculation of blood alcohol concentration from the serum alcohol using the conversion factor of 1,20 leads to a levelling of differences of about 10%.

Anemia↗

Progestational agents and blood coagulation. VIII. Effect of low-dose, alternate-day, estrogen-progestin combinations on blood coagulation factors in man, with a special note on the effect of freezing of blood samples.

Changes in the blood coagulation system were studied in three groups of 20 patients each. The first group received 0.5 mg. of norethindrone daily, plus 0.06 mg. of ethinyl estradiol on alternate days from cycle Day 5 through 25. The second group, all of whom had been fitted with an intrauterine contraceptive device (IUD), received no hormonal treatment and served as a control group. The third group received 0.5 mg. of norethindrone daily, combined with 0.045 mg. of ethinyl estradiol given on alternate days from cycle Day 5 through 25. Blood samples were drawn prior to the initiation of the study and after three months of treatment. Tests of the following parameters of the blood coagulation system were performed: direct platelet count; platelet adhesiveness; prothrombin time; thrombin time; fibrinogen; factor II assay; activity of factors V, VII, VIII, IX, and X; antithrombin III; and fibrin/fibrinogen degradation products. For a number of these factors, both fresh and frozen blood samples were examined. It was concluded that the two treatment regimens, with the use of alternate-day estrogen administration over a three-month period, had no clinically significant effect on the blood coagulation system.

Adolescent↗

Immuno-chemical studies on blood groups; the preparation of blood group A and B substances and an inactive substance from individual horse stomachs and of blood group B substance from human saliva.

Blood group substances have been isolated from the saliva of human beings of blood group B and from the linings of individual horse stomachs. The properties of the human B substances are similar to those of hog and human blood group substances previously isolated. The horse substances showed lower hexosamine and reducing sugar and higher total and non-hexosamine nitrogen than do the materials from the other species. Materials isolated from individual horse stomachs possess either A or B activity or both. Certain stomachs yielded products of identical analytical composition but with neither blood group A, B, or O activity as measured by their ability to inhibit isoagglutination. Fucose has been identified as a constituent of the horse blood group substances.

Animals↗

[Follow-up of 3 605 cord blood donors after 6 months of cord blood donation in Guangzhou cord blood bank].

To study the program of evaluating mothers and infants after 6 months of cord blood donation, from June 1998 to February 2004, all mothers after 6 months of cord blood donation were followed-up by phone calls or letters to report on the health condition. The results showed that when 3 195 mothers were visited by phone calls, 18 mothers declined to answer. 392 letter were send to those who could not be found by phone, 15 of whom wrote back. The average time to talk with each mother was approximately 12 minutes. Follow-up on the baby donors showed two cases with chromosome abnormality, one with hypothyroidism, one with neutropenia, one with albinism and 5 dead with unclear reasons. The cord blood components from all these abnormal donors found were discarded. In conclusion, the programs to evaluate mother and baby after 6 months of cord blood donation seems important in quality control of the components stored in cord blood bank.

Adult↗

A comparison of blood agar supplemented with NAD with plain blood agar and chocolated blood agar in the isolation of Streptococcus pneumoniae and Haemophilus influenzae from sputum. Bacterial Methods Evaluation Group.

Streptococcus pneumoniae grows well and generally exhibits typical morphology on Columbia blood agar, whereas Haemophilus influenzae requires a more complex medium to meet its growth requirements - usually chocolated blood agar - on which S. pneumoniae is less easily recognisable. Therefore, a single medium that produces typical morphology of S. pneumoniae and facilitates the growth of H. influenzae would have considerable potential advantages. It has been claimed that blood agar supplemented with nicotinamide adenine dinucleotide (NAD) is such a medium. However, despite its routine use in several large diagnostic laboratories its performance has never been properly evaluated. In the present study, 1724 sputum samples were examined in four laboratories. The isolation rates of H. influenzae and S. pneumoniae on NAD-supplemented blood agar (SBA) were compared with those on a two-plate combination of plain blood (BA) and chocolated blood agar (CBA). The two-plate combination performed significantly better for both organisms; isolation rates for H. influenzae were increased from 8.16% on SBA to 11.07% on BA plus CBA and for S. pneumoniae from 4.18% to 4.68%. Isolation rates were also compared after incubation for 24 and 48 h. With the two-plate combination, isolation rates for H. influenzae and S. pneumoniae were increased by 0.98% and 0.16%, respectively, and for SBA by 0.57% and 0.32% after 48 h. However, despite this increase, SBA still performed less well than the two-plate combination.

Agar↗

Opening the blood-brain and blood-tumor barriers in experimental rat brain tumors: the effect of intracarotid hyperosmolar mannitol on capillary permeability and blood flow.

Using quantitative autoradiography, we investigated the effect of intracarotid infusions of hyperosmolar mannitol solutions on capillary permeability and blood flow. Capillary permeability, expressed in terms of a blood-to-tissue transfer constant (K), was determined in two rat brain tumor models by measuring the entry of 14C-alpha aminoisobutyric acid into brain tumor, into brain tissue adjacent to tumor, and into cortex. Cerebral blood flow was determined by measuring the uptake of 14C-iodoantipyrine in one rat brain tumor model. Blood flow was examined in the same regions as K, as well as in the corpus callosum. Before mannitol administration, K values in both Walker 256 (W256) carcinosarcoma and C6 gliomas were much higher than those in cortex. C6 gliomas were about three times more permeable than were W256 tumors. There was a direct correlation between tumor size and increased capillary permeability. Mannitol at a concentration of 1.37 M did not increase the K values for either tumor or adjacent tissue. At 1.6 M, mannitol increased the K values for both tumors (1.7-fold in C6 glioma and 13-fold in W256) as well as for adjacent tissue. At both concentrations, mannitol markedly increased cortical K values in all groups: by 48- to 72-fold at 1.37 M and by 90- to 105-fold at 1.6 M. The net effect of the mannitol was to reverse the tumor-to-cortex permeability relationship. Cortical blood flow increased modestly after intracarotid mannitol administration on both sides of the brain. These data provide little justification for using intracarotid mannitol during chemotherapy of human brain tumors.

Animals↗

Reduction in blood loss and blood use after cardiopulmonary bypass with high-dose aprotinin versus autologous fresh whole blood transfusion.

Ninety patients undergoing cardiac surgery were randomly divided into three groups of 30 patients to compare the effects on bleeding and transfusion requirements of either intraoperative infusion of high-dose aprotinin (GpI) or reinfusion of autologous fresh whole blood (GpII) versus a control group (GpIII). Standardized anesthetic, perfusion, and surgical techniques were used. Platelet counts, hemoglobin concentration, hematocrit, fibrinogen, and Ivy-Nelson bleeding times determined at fixed times perioperatively did not differ among the three groups. The total loss from the chest drains was significantly reduced in GpI (328 +/- 28 mL; mean +/- SEM) as compared with the loss in GpII and GpIII (775 +/- 75 mL and 834 +/- 68 mL, respectively). There was a threefold difference in the total hemoglobin loss (GpI, 14.2 +/- 1.7 g; GpII, 50.1 +/- 5.0 g; GpIII, 45.0 +/- 5.2 g). GpI patients also received less banked blood: 250 +/- 53 mL versus 507 +/- 95 mL in GpII and 557 +/- 75 mL in GpIII. No GpI patient required transfusion of platelets or fresh frozen plasma. Fresh whole autologous blood transfusions had no significant hemostatic effect and failed to reduce the homologous blood requirement. Conversely, high-dose aprotinin reduced blood loss and transfusion requirements.

Adult↗

Antibody to histo-blood group A antigen neutralizes HIV produced by lymphocytes from blood group A donors but not from blood group B or O donors.

Three virus isolates HTLV-IIIB/lyA, HTLV-IIIB/lyB and HTLV-IIIB/lyO, obtained by passaging and propagating the HTLV-IIIB/H9 isolate in three separate cultures of mixed peripheral blood mononuclear cells (PBMC) from donors of blood type A, B or O, respectively, were tested for susceptibility for virus neutralization by the monoclonal antibody (MAb) AH16 directed against the blood group A epitope. MAb AH16 was previously shown to inhibit cell-free virus infection using HTLV-IIIB propagated in H9 cells. AH16 showed a concentration-dependent inhibition of the HTLV-IIIB/lyA isolate but did not inhibit the HTLV-IIIB/lyB or the HTLV-IIIB/lyO isolate. Specificity of the MAb-mediated inhibition was shown using A-antigen (tetrasaccharide). Thus, HIV infection of PBMC from donors with blood type A appears to induce expression of host-cell-encoded carbohydrate blood group A epitope on HIV which can be a target for MAb-mediated virus neutralization.

ABO Blood-Group System↗

The effects of sodium nitroprusside on cerebral blood flow and cerebral venous blood gases. II. Observations in awake man during successive blood pressure reduction.

Cerebral blood flow (CBF) and cerebral venous blood gases were investigated in seven awake patients during hypotension induced with sodium nitroprusside. Infusion of the drug into the internal carotid artery produced no changes in cerebral haemodynamics. Intravenous nitroprusside infusion resulted in a decrease in both CBF and jugular venous PO2 (P less than 0.01, respectively). Reducing mean arterial blood pressure by 18% and 43% produced a mean CBF fall of 6% and 27% respectively. Arteriovenous oxygen difference increased in consonance with the CBF decrease (P less than 0.01). Arterial PCO2 fell during the infusion (P less than 0.01). At 18% blood pressure reduction, the observed PCO2 decrease of 0.25 kPa could account for the 6% CBF decrease. At 43% blood pressure reduction, PCO2 fell by 0.53 kPa, a decrease which could not explain the observed CBF fall of 27%. Dizziness and incipient fainting occurred in the patients at this point. It is concluded that sodium nitroprusside has a minor but significant effect on cerebral haemodynamics in normal awake man.

Adult↗

No effect of prostacyclin on blood flow, regulation of blood flow and blood coagulation following global cerebral ischemia.

In normothermic cats under light barbiturate anesthesia, cerebral blood flow was arrested for one hour by intrathoracal occlusion of the innominate, the left subclavian, and both mammary arteries. Recirculation of the brain after ischemia resulted in reactive hyperemia, followed by a decrease of blood flow to about 70% of control (post-ischemic hypoperfusion). During postischemic hypoperfusion, CO2-reactivity was completely abolished. Intravenous infusion of prostacyclin 2 hours after ischemia (1.8 micrograms/kg/min) decreased systemic arterial blood pressure and reduced platelet aggregability but did not improve cerebral blood flow, did not restore CO2-reactivity, and did not influence postischemic changes of blood coagulation. It is concluded that prostacyclin deficiency is not or not the only reason for the development of post-ischemic hypoperfusion and the associated disturbance of flow regulation.

Animals↗