Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “quantification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79Linked to original sources

Quantification of N-CAM and N-cadherin expression in axotomized and crushed rat sciatic nerve.

Adhesion molecules are important in supporting axonal regeneration. Qualitative studies have described increased expression of neural cell adhesion molecule (NCAM) and N-cadherin in models of nerve injury allowing active regeneration. In this study we have used quantitative immunohistochemistry to compare expression of NCAM and N-cadherin after nerve injury either with active regeneration (crush) into the distal stump or without (axotomy and capping). Quantification was performed 15 days after axotomy in proximal and distal stumps. Quantification after crush either proximal, distal or within the crushed area was performed at 2, 7, 15 and 30 days after injury. Axotomy induced increases in expression in proximal stumps between two and three times those in uninjured nerves for both molecules. In distal stumps, N-cadherin levels increased seven-fold, yet NCAM levels did not exceed control values. After crush, NCAM immunoreactivity increased in the crushed area and distal stump in contrast to axotomy and NCAM-positive axons co-localized with PGP9.5. N-cadherin levels in the distal stump increased above control levels, but the magnitude of the increase seen after crush was different to those seen after axotomy. In conclusion, increased expression of adhesion molecules, particularly NCAM, in the distal stump of injured nerves is dependent upon the presence of regenerating axons.

Animals↗

Development of a standard operating procedure (SOP) for the precise quantification of transgene expression levels in rice plants.

Variation in transgene expression levels can result from uncontrolled differences in experimental protocols. It is important to quantify and eliminate this unwanted variation as much as possible in order to attain precision in transgenic studies. Large-scale transgenic studies could, by their design, generate additional variation. The influence of different plant growth, sampling and analysis strategies in generating spurious variation in transgene expression level quantification in rice plant populations was assessed. The use of multiple independent plant phenotypic analyses (enzymatic assays in this study) was identified as the major source of spurious variation (doubling or tripling the variation). The quantification of transgene expression levels was also found to be significantly influenced by plant age, the choice of leaf sampled and leaf size. All of these factors reduced the precision of molecular genetic studies and generated artefactual results in transgenic studies. Identification of the sources of extraneous variation allowed the development of a new standard operating procedure (SOP) for rice, designed to control spurious variation. SOP allowed the influence of differences in growth period and independent phenotypic analyses to be minimized. The coefficient of variation in transgene expression levels, between and within genetically identical rice plants, was reduced to approximately 10 to 15% using SOP. Adoption of quality assurance (QA) criteria such as SOP is key to improving the reproducibility of transgenic studies.

Journal Article↗

Rapid detection and quantification of Japanese encephalitis virus by real-time reverse transcription loop-mediated isothermal amplification.

We established a rapid, quantitative real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay targeting the envelope gene of Japanese encephalitis virus. The RT-LAMP enabled us to detect the target product within 1 hr by only reacting reverse transcriptase and Bst DNA polymerase in a single tube at an isothermal temperature. The detection sensitivity of the RT-LAMP for Japanese encephalitis virus was 1 PFU, similar to that of conventional reverse transcription-polymerase chain reaction (RT-PCR). Flaviviruses of the Japanese encephalitis virus group, such as Dengue virus and West Nile virus, could not be detected. This confirmed the specificity of the RT-LAMP assay for Japanese encephalitis virus. A standard curve was constructed by plotting viral titer against the time for virus detection by the RT-LAMP, validating the quantitative accuracy of the assay. In addition, the amount of virus estimated by RT-LAMP was strongly correlated (r = 0.902) with that determined by plaque assay, a conventional method for virus quantification. These results indicate that the RT-LAMP assay established in this study is specific for Japanese encephalitis virus, and allows more rapid detection and quantification of the virus.

Animals↗

Joint cytokine quantification in two rodent arthritis models: kinetics of expression, correlation of mRNA and protein levels and response to prednisolone treatment.

Biomarker quantification in disease tissues from animal models of rheumatoid arthritis (RA) can help to provide insights into the mechanisms of action of novel therapeutic agents. In this study we validated the kinetics of IL-1beta, TNF-alpha and IL-6 mRNA and protein expression levels in joints from DBA/1OlaHsd murine collagen-induced arthritis (CIA) and Lewis rat Streptococcal cell wall (SCW)-induced arthritis by real-time polymerase chain reaction (PCR) TaqMan and Enzyme-linked immunosorbent assay (ELISA). Prednisolone was used as a reference to investigate any correlation between clinical response and cytokine levels at selected time-points. To our knowledge this is the first report showing a close pattern of expression between mRNA and protein for IL-1beta and IL-6, but not for TNF-alpha, in these two models of RA. The kinetics of expression for these biomarkers suggested that the optimal sampling time-points to study the effect of compounds on both inflammation and cytokine levels were day 4 postonset in CIA and day 3 after i.v challenge in SCW-induced arthritis. Prednisolone reduced joint swelling through a mechanism associated with a reduction in IL-1beta and IL-6 protein and mRNA expression levels. At the investigated time points, protein levels for TNF-alpha in arthritic joints were lower than the lower limit of detection of the ELISA, whereas mRNA levels for this cytokine were reliably detected. These observations suggest that RT-PCR TaqMan is a sensitive technique that can be successfully applied to the quantification of mRNA levels in rodent joints from experimental arthritis models providing insights into mechanisms of action of novel anti-inflammatory drugs.

Animals↗

Quantification of red blood cell fragmentation by the automated hematology analyzer XE-2100 in patients with living donor liver transplantation.

The fragmented red cell (FRC) is a useful index for diagnosing and determining the severity of thrombotic thrombocytopenic purpura (TTP), thrombotic microangiopathy (TMA) and other similar conditions, as it is found in peripheral blood in patients with these diseases. The FRC expression rate has conventionally been determined by manual methods using smear samples. However, it is difficult to attain accurate quantification by such methods as they are time consuming and prone to a great margin of error. With cases of living donor liver transplantation, the current study examined the possibility of using a multi-parameter automated hematology analyzer, the XE-2100 (Sysmex Corporation) for FRC quantification. While there was a notable correlation between the manual and automated measurements, the manual measurement resulted in higher values. This suggested remarkable variations in judgment by individuals. The FRC values had a significant correlation with the reticulocyte count, red blood cell distribution width (RDW), fibrin/fibrinogen degradation products (P-FDP) and lactate dehydrogenase (LDH) among the test parameters, and this finding was consistent with the clinical progression in patients. The automated method can offer precise measurements in a short time without inter-observer differences, meeting the requirement for standardization. The determination of FRC count (%) by the XE-2100 that enables early diagnoses and monitoring of TTP or TMA will be useful in the clinical field.

Adolescent↗

Quantification of urinary growth hormone (GH) excretion by centrifugal ultrafiltration and radioimmunoassay: appraisal of the relationship between 24 h urinary GH and mean 24 h serum GH levels in normal and abnormal states of GH secretion.

We have applied a simple method for the quantification of 24 h urinary GH excretion (24 h UGH), combining centrifugal ultrafiltration and radio-immunoassay (RIA), to an appraisal of the relationship between 24 h UGH and mean 24 h serum GH levels in normal and abnormal states of GH secretion. Forty-four subjects, comprising 13 normal adults, 12 short-statured subjects and 19 subjects with active acromegaly, underwent blood sampling at 20-min intervals and concurrent urine collection for 24 h. Mean 24 h serum GH and 24 h UGH were also determined in four post-menopausal women before and during cyclical oestrogen replacement therapy, and 24 h UGH was measured in six normal men prior to and following the subcutaneous administration of biosynthetic GH (0.2 IU/kg). Each subject's mean 24 h serum GH level was determined by assaying a 'pooled' sample, derived from equal aliquots of the 73 serum samples obtained during the 24 h study. The method for quantification of 24 h UGH employs centrifugal microconcentrators, and involves a 50-fold concentration of urine, followed by dialysis and RIA. Surface adsorptive hormone loss during sample collection and ultrafiltration is minimized by the prior addition of bovine serum albumin to the urine collection container. Immunoreactive GH in ultrafiltered urine dilutes in parallel with the RIA standard curve. GH is stable in urine stored at - 20 degrees C for at least 12 months. There was a highly significant correlation between 24 h UGH and mean 24 h serum GH values obtained from the combined population of normal adults (including the post-menopausal women during oestrogen therapy) and short-statured subjects (r = 0.69, P less than 0.0001). A significant correlation was also found in short-statured subjects alone (r = 0.63, P less than 0.05). In contrast, there was no significant correlation between 24 h UGH and mean 24 h serum GH in subjects with active acromegaly, and their 24 h UGH values were not distinguishable from those of the 'non-acromegalic' subjects. A significant increase in 24 h UGH occurred in the post-menopausal women given cyclical oestrogen replacement therapy (9.7 +/- 2.6 (mean +/- SE) to 24.6 +/- 1.0 muIU/mmol creatinine, P less than 0.02), reflecting the increase in their mean 24 h serum GH levels (0.8 +/- 0.3 to 5.3 +/- 0.7 mIU/l, P less than 0.01). Twenty-four hour UGH increased from 4.6 +/- 0.6 to 17.1 +/- 2.1 muIU/mmol creatinine (P less than 0.002) in the men given biosynthetic GH. Twenty-four hour UGH measurements reflect mean 24 h serum GH levels in normal adults and short-statured subjects. While the measurement of 24 h UGH shows promise as an investigative tool, our results cast doubt on its use in the diagnosis of acromegaly.

Acromegaly↗

In situ quantification of biocide efficacy using GFP transformed Aureobasidium pullulans.

AIMS: To develop a real-time in situ method to quantify loss of viability of Aureobasidium pullulans PRAFS8 cells attached to plasticized polyvinyl chloride (pPVC) with incorporated biocides, and to use the method to compare biocide efficacy in situ. METHODS AND RESULTS: A. pullulans PRAFS8, transformed with green fluorescent protein (GFP), was used to quantify the efficacy of a range of biocides incorporated into pPVC. Experimentally, it was found that a density of 1.53 x 10(6) yeast cells per cm(2) of pPVC was optimal as increasing the density of the yeast cells to 6.12 x 10(6) cm(-2) attached to pPVC containing the biocide 2-n-octyl-4-isothiazolin-3-one (OIT) decreased the rate of fluorescence loss. A strong positive correlation between fluorescence and viable yeast cell number was observed and fluorescence was used as a direct indicator of cell viability. The effectiveness of five commercial biocides, commonly incorporated into pPVC at their in-use concentrations, was tested against yeast cells attached to the pPVC surface. The loss of fluorescence and hence viability in situ was quantified using image analysis. The biocides N-(trichloromethylthio) phthalimide (NCMP), 10,10'-oxybisphenoxarsine (OBPA), OIT and 2,3,5,6-tetrachloro-4-(methylsulphonyl) pyridine (TCMP) caused complete loss of fluorescence within 30-50 h. In contrast the biocide dichloro-octyl-isothiazoline caused only 55 +/- 15% fluorescence loss after 50 h. Starvation of the yeast cells in suspension for 24 h prior to attachment reduced their initial sensitivity to OBPA, NCMP, OIT and TCMP by 15-20%, but eventually the fluorescence was also completely lost. CONCLUSIONS: The use of A. pullulans expressing cytosolic GFP enables the in situ quantification of loss of viability when cells are attached to pPVC with incorporated biocides. SIGNIFICANCE AND IMPACT OF THE STUDY: GFP fluorescence was used as a real-time indicator of cell viability and thus can be applied for direct quantification of the effectiveness of a broad range of biocides, incorporated into the polymer mass and used to protect a variety of plastics or other materials from microbial growth.

Antifungal Agents↗

Gap-junction quantification in biological tissues: freeze-fracture replicas versus thin sections.

The relative efficiency of freeze-fracture replicas versus thin sections for the visualization and quantification of gap junctions in biological tissues has been evaluated. Both methods may underestimate gap-junction number--thin sections for reasons of tissue resolution and freeze-fracture replicas due to the mechanics of the fracturing process. Freeze-fracture misses gap junctions in regions of plasma membrane which are highly contoured, such as the overlapping basal cell processes of Drosophila imaginal wing discs and the interdigitating lateral membrane plications of intercalated discs in cardiac tissue. If the missed gap junctions are relatively large, as they are in both of these examples, freeze-fracture significantly underestimates the total gap-junctional area. Thin sections may miss small gap junctions, but in tissues which contain a range of gap-junction sizes the lost junctions constitute a relatively small fraction of the total junctional area. In neoplastic imaginal wing discs, thin sections were as efficient as freeze-fracture replicas in identifying even the smallest gap junctions. Although freeze-fracture may be the better technique for the qualitative and quantitative documentation of small gap junctions in tissues with relatively flat to gently contoured plasma membranes and thin sections may be the superior method for gap-junction quantification in tissues containing a range of gap-junctional sizes and highly contoured cellular processes, the data suggest that a combination of the two approaches should be utilized whenever possible.

Animals↗

The quantification of fluorescent emission from biological samples using analysis of polarization.

The quantification of fluorescent emission from biological specimens can only be carried out in cellular regions where the relationship between fluorophore concentration and fluorescent emission is linear. Using a confocal scanning laser microscope, we show that quantification of fluorescent emission from biological samples labelled with fluorescein and fluorescein analogues mounted in a viscous medium can be readily achieved. Where the distribution of fluorophore is highly localized, for example in cells labelled for immunofluorescence analysis, we demonstrate that analysis of fluorescence depolarization can identify regions in which fluorophore concentration exceeds the range in which the relationship to fluorescent emission is linear. We also demonstrate that, under the conditions examined, depth-dependent effects, fading and quenching are either small enough to be ignored or can be corrected for mathematically when quantifying fluorescent emission.

Animals↗

Signal standardization of the secondary ion mass spectrometry (SIMS) microscope for quantification of halogens and calcium in biological applications.

The secondary ion mass spectrometry (SIMS) microscope is able to map chemical elements in tissue sections. Although absolute quantification of an element remains difficult, a relative quantitative approach is possible for soft tissue by using carbon (12C) as an internal reference present at large homogeneous and constant concentration in specimen and embedding resin. In this study, this approach is used to standardize the signal of an SIMS microscope for the quantification of halogens (9F-, 35Cl- and 79Br-) and calcium (40Ca+). Standard preparation was determined based on homogeneity and stability criteria by molecular incorporation (halogens) or mixing (calcium) in methacrylate resin. Standard measurements were performed by depth analysis on areas of 8 microns (halogens) and 150 microns (calcium) in diameter for 10-30 min, under Cs+ (halogens) or Ox+ (calcium) bombardment. Results obtained from 100-120 measurements for each standard dilution show that the relationship between the signal intensity measured and the elemental concentration (micrograms/mg of wet tissue or mM) is linear in the range of biological concentrations. This quantitative approach was applied firstly to bromine of the 5-bromo-2'-deoxyuridine (BrdU) used as nuclear marker of rat hepatocytes in proliferation. The second model concerns depletion of calcium concentration in cortical compartment in Paramecium tetraurelia during exocytosis. Then signal standardization in SIMS microscopy allows us to correlate quantitative results with those obtained from other methods.

Animals↗

Hepatitis C virus RNA quantification in right and left lobes of the liver in patients with chronic hepatitis C.

Quantification of hepatitis C virus RNA in liver tissue is likely to be useful in the study of the natural history, pathogenesis, progression and treatment of hepatitis C virus-associated liver disease. Quantitative measurements of hepatitis C virus RNA in liver biopsy samples using the branched DNA (bDNA) signal amplification assay were carried out. The aims of this study were threefold: first, to assess the level of hepatitis C virus RNA in biopsy samples from the right and left lobes of the liver; second, to evaluate the correlation between hepatitis C virus RNA levels in serum and liver; and third, to investigate the relationship between serum and liver hepatitis C virus RNA levels and the severity of hepatic histology in non-cirrhotic patients with chronic hepatitis C. There was a strong correlation (r = 0.92, P < 0.01) between hepatitis C virus RNA levels in the right and left lobes of the liver as well as a strong correlation between hepatitis C virus RNA levels in liver and serum (r = 0.82, P < 0.01). However, there was no significant correlation between the severity of hepatic histology and levels of hepatitis C virus RNA in serum and liver among patients with chronic active hepatitis classified according to Knodell's hepatic activity index (KI). Our results indicate that hepatitis C virus RNA quantification from a single liver biopsy is representative of both lobes in patients with chronic hepatitis, and suggest that serum hepatitis C virus RNA levels are a meaningful reflection of hepatitis C virus RNA levels in the liver.

Adult↗

Real-time quantification of human telomerase reverse transcriptase mRNA in liver tissues from patients with hepatocellular cancer and chronic viral hepatitis.

We determined, for the first time, the human telomerase reverse transcriptase (hTERT) mRNA expression, using real-time quantitative PCR, in liver tissues from patients with hepatocellular cancer (HCC; n = 13), chronic hepatitis B (n = 19) and C (n = 13). Liver tissues from the 45 patients and 17 patients without liver disease in whom liver biopsy was performed during cholecystectomy (control group), were investigated for telomerase activity (TA) and hTERT mRNA expression using the LightCycler technology. TA was detected in all HCC tissues compared with 15.6% of chronic hepatitis (P < 0.001) and none of controls (P < 0.001). TA levels and hTERT mRNA were higher in HCC compared with chronic hepatitis (P < 0.001) and normal livers (P < 0.001). hTERT mRNA expression was correlated with TA (P < 0.05). Chronic hepatitis patients who tested negative for TA and hTERT mRNA had significantly lower disease duration (58 +/- 85 months) compared with those tested positive (144 +/- 50 months; P < 0.05). Detection of TA and quantification of hTERT mRNA expression in liver tissues could be useful and additional markers for HCC diagnosis and may serve as prognostic markers for HCC development in chronic viral hepatitis patients. However, we were not able to draw general conclusions at this moment, as the number of chronic hepatitis patients positive for hTERT mRNA was relatively small. Real-time quantification of hTERT mRNA expression as a diagnostic/prognostic marker in patients with chronic hepatitis B and C and its relationship with hepatocarcinogenesis needs further evaluation.

Adult↗

Quantification of the pregnancy-specific beta1-glycoprotein (SP1) by immunoprecipitation techniques: the influence of a cross-reacting high molecular weight alpha2-protein.

Two serum proteins with SP1 determinants were separated by means of size chromatography and preparative zone electrophoresis. One of the proteins had beta1 electrophoretic mobility and an estimated molecular weight of 90,000, and the other had alpha2-mobility and a molecular weight around 400,000. When available antibody preparations to SP1 were used, the high molecular weight protein formed immunoprecipitates only when polyethyleneglycol (PEG) was added to the agarose. It is shown that the high molecular weight protein has a pronounced effect on quantification of SP1 by rocket immunoelectrophoresis, whereas the effect was less pronounced but still considerable when quantification was performed by radial immunodiffusion.

Antigens↗

Quantification of Blo t 5 in mite and dust extracts by two-site ELISA.

BACKGROUND: Blomia tropicalis is an important mite species in the tropical and sub-tropical regions of the world. Blo t 5 is the major allergen with up to 70% sensitization rates in B. tropicalis allergic populations. METHODS: Mice were immunized intramuscularly with naked plasmid DNA encoding Blo t 5 gene with in vivo electroporation. Blo t 5 monoclonal antibodies were generated using methylcellulose-based hybridoma kit. Monoclonal antibody (mAb) 4A7 was characterized by two-dimensional electrophoresis immunoblotting. A specific quantitative two-site enzyme-linked immunosorbent assay (ELISA) was developed with mAb 4A7 and guinea pigs Blo t 5 polyclonal antibody as capture and detection antibodies, respectively. This system was tested with Blo t 5 in crude extracts and dust samples. RESULTS: A high-affinity mAb 4A7 recognizing several isoforms of Blo t 5 has been generated. Monoclonal antibody 4A7 is useful for immunoblotting and two-site ELISA. The two-site ELISA developed has a high sensitivity, with a detection limit of 10 pg/ml. The assay is species-specific and recognized the same epitopes on both native and recombinant Blo t 5. The assay developed is able to detect Blo t 5 in commercial diagnostic and therapeutic B. tropicalis extract. Blo t 5 quantification in dust samples showed that Blo t 5 is present in a high quantity in Singapore dust. CONCLUSIONS: A highly sensitive and specific two-site ELISA has been developed. The assay system developed is useful for the quantification of Blo t 5 in mite and environmental dust extracts.

Allergens↗

Monoclonal antibodies to native mouse angiotensin-converting enzyme (CD143): ACE expression quantification, lung endothelial cell targeting and gene delivery.

We demonstrated previously that the monoclonal antibody 9B9 to angiotensin-converting enzyme (ACE), which accumulates very selectively into the rat lung after systemic injection, is a powerful tool for immunotargeting of therapeutic agents or genes to the rat lung vascular bed. Bearing in mind a high research and therapeutic potential of lung targeting via ACE, we obtained a new set of rat monoclonal antibodies to different epitopes of mouse ACE in order to expand this approach to mice. Nine new monoclonal antibodies, recognizing epitopes on the N- and C-domains of catalytically active mouse ACE, were obtained and examined for their efficacy to bind ACE both in vitro and in vivo. This set of monoclonal antibodies was proved to be useful for ACE quantification (by flow cytometry and cell enzyme-linked immunosorbent assay) on the surface of different mouse ACE-expressing cells: endothelial cells, monocytes, macrophages, dendritic cells and spermatozoa. Moreover, gene delivery into mouse ACE-expressing cells using adenoviruses increased 40-fold after redirecting of these viruses to ACE (by coating these viruses with anti-ACE monoclonal antibodies). Radiolabelled (I(125)) monoclonal antibodies specifically accumulated in the mouse lung after systemic injection. Monoclonal antibodies 3G8.17, 4B10.5 and 4B10.17 demonstrated the highest level of lung uptake, 40-50% of injected dose, and high selectivity of lung uptake. Influence of monoclonal antibodies on ACE shedding was negligible, except monoclonal antibody 1D10.11. None of the tested monoclonal antibodies inhibited ACE activity in vitro. In conclusion, a new set of rat monoclonal antibodies to mouse ACE was obtained suitable to study ACE biology in mice and for ACE expression quantification on mouse cells in particular. These monoclonal antibodies also demonstrated highly efficient and selective lung accumulation and thus has the potential for targeting drugs/genes to the pulmonary vasculature in different mouse models of human lung diseases, including numerous knockout models.

Adenoviridae↗

Colorimetric microtiter plate based assay for detection and quantification of amplified Actinobacillus actinomycetemcomitans DNA.

We developed a colorimetric microtiter plate-based assay for the detection and quantification of polymerase chain reaction-amplified DNA fragment specific for Actinobacillus actinomycetemcomitans. We amplified the 396-bp leukotoxin-specific DNA fragment by using two oligonucleotide primers, one carrying a biotin group at the 5' end and another one with a digoxigenin at the 5' end. Following amplification, the biotinylated polymerase chain reaction products were applied to a microtiter well precoated with avidin. The colorimetric detection and quantification were achieved by an enzyme-linked immunosorbent assay using alkaline phosphatase-conjugated anti-digoxigenin antibody. The detection limit of the colorimetric assay was found to be as little as 500 fg of purified A. actinomycetemcomitans DNA and as few as 50 A. actinomycetemcomitans. Therefore, this colorimetric assay was able to estimate the amount of A. actinomycetemcomitans in subgingival plaque samples. We concluded that the colorimetric assay of the PCR product is a very useful method not only to detect the presence of A. actinomycetemcomitans but also to quantify the amount of A. actinomycetemcomitans in large numbers of subgingival plaque samples.

Aggregatibacter actinomycetemcomitans↗

Current status of dosing and quantification of acute renal replacement therapy. Part 2: dosing paradigms and clinical implementation.

The dosing and quantification of acute renal replacement therapy has emerged as one of the most pressing issues in the management of critically-ill patients with acute kidney injury. Although there is ongoing debate as to the best marker of uraemic injury in this setting, several landmark studies have identified clearance-related expressions of acute renal replacement therapy dose as important determinants of survival. Part 1 of this review examined the factors affecting the delivery of prescribed acute renal replacement therapy dose. Part 2 summarises and contextualises findings from recent dose-outcome studies, and reviews clinical tools to assist in the prescription and quantification of acute renal replacement therapy dose.

Acute Kidney Injury↗

Detection and quantification of Listeria monocytogenes by 5'-nuclease polymerase chain reaction targeting the actA gene.

AIMS: The aim of this study was to develop a 5'-nuclease polymerase chain reaction (PCR) for the rapid detection and quantification of Listeria monocytogenes. METHODS AND RESULTS: Specific primers and a fluorogenic probe were designed, which target a specific sequence of the actA gene encoding for a protein involved in the actin filament assembly. The PCR system was highly sensitive and specific for L. monocytogenes (inclusivity, 100%; exclusivity, 100%), which was determined using 46 L. monocytogenes and 28 non-L. monocytogenes strains. Detection limits of 10(4) cfu ml(-1) after 35 cycles and 10(2) cfu ml(-1) after 45 cycles were achieved by PCR in both real-time and end-point fluorescence measurement modes. Linear calibration lines were obtained in the range from 10(2) to 10(9) cfu ml(-1) for three L. monocytogenes strains in real-time PCR with 45 cycles. CONCLUSIONS: The developed 5'-nuclease PCR of the actA gene provides a new target for the rapid detection and quantification of L. monocytogenes. SIGNIFICANCE AND IMPACT OF THE STUDY: In conjunction with enrichment or with an appropriate quantitative sample preparation technique, the method is suitable for food safety applications.

Bacterial Proteins↗