Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Motion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79Linked to original sources

Effects of surface markings on judgments of motion direction.

The effects of surface markings on perceived motion direction were examined for a rotating sphere in a structure-from-motion display. The markings were dot patterns representing separate line segments or intersecting line segments (crosses) covering the surface of the sphere. The orientation of the surface markings and their intersection angles affected the perceived direction of motion, suggesting that the markings were not interpreted as geodesics or planar cuts on the surface. The perceived direction of motion was biased towards the mean orientation of the markings over the visible area of the surface. A similar bias was observed for translating planar stimuli covered with crosses, suggesting that the bias is not specific to curved surfaces or motion in depth. The deviation between the simulated motion direction and the external horizontal and vertical axes also affected the perceived motion direction. These results suggest that the average orientation of surface contours with respect to an external reference frame influences the perceived direction of motion.

Depth Perception↗

Invalid cues impair auditory motion sensitivity.

Compelling lateral motion can be experienced when intensity differences between the two cars change over time. Whether our sensitivity to this dynamic interaural stimulation could be influenced by directional cues was the focus of the present study. On each trial, amplitude-modulated pure tones were presented either diotically (no-motion condition) or dichotically (motion condition), and participants indicated whether lateral motion was present or absent. Randomly across trials, the stimuli were preceded by a valid directional cue, an invalid directional cue, or no cue, while the motion to be detected was identical across these cue conditions. The data indicate that motion sensitivity was comparable in the valid-cue and no-cue conditions. Relative to each of those conditions, however, motion sensitivity was significantly lower in the invalid-cue condition, and motion was reported significantly less often. The results provide evidence that our sensitivity to dynamic interaural intensity differences can be significantly affected by a non-sensory factor, namely cue validity.

Adult↗

Colour, polarity, disparity, and texture contributions to motion segregation.

We measured how different cues are combined in motion-segregation processes by using motion stimuli where randomly distributed target dots were organised in global revolving motion while the remaining noise dots performed random motion. Target dots were cued with a different colour, polarity, disparity depth, or texture orientation than the noise dots, or they were the same as the noise dots. The stimuli were presented with a prolonged static cue preview which provided position cues to target dots or, briefly with static pre-target and post-target noise frames, which provided false position cues (no preview). All cues efficiently facilitated global motion segregation in cued-preview conditions. Colour completely failed to facilitate global motion segregation in no-preview conditions. Polarity and disparity facilitated segregation in no-preview conditions, although sensitivities were lower than in the preview conditions. Remarkably, texture orientation largely facilitated motion segregation by the same amount in both cued-preview and no-preview conditions. So, colour provides only position cues to the motion-segregation task whereas texture orientation, disparity, and to a lesser extent polarity are integrated with the segregation process.

Color Perception↗

Effects of motion parallax and perspective cues on perceived size and distance.

In three experiments we examined the relative effectiveness of motion parallax and two perspective cues for the perception of size and distance. The experimental stimuli consisted of two ellipses (a standard and a comparison) and a horizontal line that indicated the horizon. The subject's task was to report the apparent size and distance of the comparison stimulus relative to the standard stimulus. Two perspective cues were given by the relative heights of the two stimuli and the absolute height of the standard stimulus below the horizon. Motion parallax was defined by both the ratio and the difference in angular velocities between the two stimuli on the display. In experiment 1 we examined the effects of the two perspective cues and the motion parallax. In experiment 2 we eliminated the horizon line, and examined the role of the horizon in size and distance perception. In experiment 3 we separately evaluated the effects of motion parallax and the relative height cues. The results from the three experiments showed that the effect of motion parallax and the two perspective cues were different in three ways. First, the relative effectiveness of motion parallax and the two perspective cues differed for size and distance estimates. For size estimates, the motion parallax was more effective than the perspective cues (experiments 1 and 3). For distance estimates, the motion parallax was as effective as the two perspective cues (experiments 1 and 3). Second, the role of the horizon differed for size and distance estimates. The size estimates were strongly affected by the horizon, while the distance estimates were not affected much by the horizon (experiment 2). Third, the effective perspective cues differed for the size estimates and the distance estimates: size estimates were affected by the perspective cues as a combination of the horizon and relative height; distance estimates were affected by the perspective cues as an interaction between the absolute and relative heights without the horizon line.

Cues↗

Unobtrusive vehicle motion prediction cues reduced simulator sickness during passive travel in a driving simulator.

This study investigated cues that permit prediction of turns during passive movement through a virtual environment. Effects on simulator sickness (SS), presence and enjoyment were examined. Subjects were exposed to complex visual motion through a cartoon-like simulated environment in a driving simulator. Forward velocity remained constant and the motion path was the same across all experimental conditions. Using a within-subject design, we examined visual paths that provided different levels of cue salience - detailed, simplified and no cues - for the upcoming simulated vehicle motion. Following each trial, participants completed questionnaires on SS, presence and enjoyment. After all of the trials were completed, a debriefing determined participants' perceptions of vehicle motion attributes and their awareness of the prediction cues. The results showed that SS in the no-cue condition was significantly greater than that in the conditions that provided vehicle motion cues. Presence and enjoyment responses were not different across the conditions. No participants reported differences between prediction cue conditions or recognized that the vehicle motion followed the same path across trials. However, participants tended to report that the motion was smoother for the detailed-cue than the no-cue condition. Participants ranked turn predictability as higher in conditions with prediction cues. The results support the hypothesis that unobtrusive and unreported motion cues may alleviate SS in a virtual environment.

Adolescent↗

Working on a moving surface--a biomechanical analysis of musculo-skeletal load due to ship motions in combination with work.

Ship motions are recognized by fishermen as a cause of high musculo-skeletal load. In the present study, the motions of a Swedish trawler at sea were registered over three degrees of freedom. Simultaneously, the working postures of a fisherman on board were registered in the sagittal plane during five different working situations: (1) standing erect in still conditions; (2) holding a load of 21 kg in still conditions; (3) standing erect during motion of the ship; (4) standing during motion of the ship, holding a load of 21 kg; and (5) repeatedly lifting and lowering a 21 kg load during motion of the ship. All registrations were sampled using a computer where data were processed in a two-dimensional, dynamic biomechanics model, developed for this particular purpose. Vertical and horizontal forces as well as moments were calculated for seven major joint systems of the body, as was compression at the L4/L5 vertebral level. In situation (3), ship motions were mainly counteracted by motions in the lower extremity and lumbar back, thus inducing increased strain in these parts of the body; other parts of the body were little affected. Holding a load considerably increased the load on most joints. Lifting the load further increased the musculo-skeletal strain and also increased the range of moments in each joint as well as the range of lumbar compression. Moment at the C7 vertebral level was relatively unaffected by ship motions and by handling external loads.

Biomechanical Phenomena↗

Influences of the perception of self-motion on postural parameters.

We examined how spatial and temporal characteristics of the perception of self-motion, generated by constant velocity visual motion, was reflected in orientation of the head and whole body of young adults standing in a CAVE, a virtual environment that presents wide field of view stereo images with context and texture. Center of pressure responses from a force plate and perception of self-motion through orientation of a hand-held wand were recorded. The influence of the perception of self-motion on postural kinematics differed depending upon the plane and complexity of visual motion. Postural behaviors generated through the perception of self-motion appeared to contain a confluence of the cortically integrated visual and vestibular signals and of other somatosensory inputs. This would suggest that spatial representation during motion in the environment is modified by both ascending and descending controls. We infer from these data that motion of the visual surround can be used as a therapeutic tool to influence posture and spatial orientation, particularly in more visually sensitive individuals following central nervous system (CNS) impairment.

Adult↗

Effect of stone motion on in vitro comminution efficiency of Storz Modulith SLX.

BACKGROUND AND PURPOSE: During SWL, stone motion secondary to ventilatory motion can be as much as 50 mm. This is much larger than the 4- to 15-mm diameter of the focal regions on most clinical machines. The goal of this study was to determine the effect of stone motion on the fragmentation efficiency of a clinical lithotripter with a small (4-mm) focal spot. MATERIALS AND METHODS: A model stone (6.5 x 7.5 mm) made of gypsum cement was used as an in vitro target for a Storz Modulith SLX lithotripter with a custom-designed waterbath. A motorized positioner was used to translate the stone in order to simulate ventilatory motion. The excursion was variable up to 48 mm (+/- 24 mm about the focus). After treatment by 400 shockwaves, the remnants (> 2 mm) were dried and weighed. RESULTS: Fragmentation efficiency was reduced (P < 0.05) for motion of > or = 10 mm. Similar results were found with different energy levels and firing rates. The reduction in fragmentation efficiency was consistent with calculations of the time the stone was outside the focal region. CONCLUSIONS: Clinically relevant stone motion has a dramatic effect on in vitro comminution. Motion of 10 mm led to a significant reduction in comminution, and for motion > 20 mm, it appeared that three-quarters of the shockwaves missed the stone. These data imply that ventilatory gating or stone tracking may result in fewer shockwaves being required for successful treatment with this lithotripter.

Electromagnetic Phenomena↗

Motion perception following lesions of the superior temporal sulcus in the monkey.

We examined the effect of bilateral ibotenic acid lesions, aimed at areas MT/MST in three macaques, on their perception of motion. The medial boundary of the lesions in the three monkeys was near the dorsal end of the STS, but the lesions extended different lengths ventrally along the STS. The lesions extended the shortest distance ventrally monkeys 1 and 2, covering most of MST but possibly sparing a portion of lateral MT. That in monkey 3 damaged all of MT and MST bilaterally and extended through most of FST. All three lesions caused a temporary disruption, followed by at least partial recovery, of most motion thresholds. Permanent effects of the lesions on visual sensitivity were graded with lesion extent. Contrast sensitivity for detecting low-spatial-frequency (1 cycle/degree) drifting gratings over a wide range of drift rates, as well as for identifying their direction of motion, was slightly affected only in monkey 3. Only monkeys 2 and 3 showed a deficit in discriminating stimulus speed, and the size of the loss was two- to fourfold. Discrimination of opposite directions of dot pattern motion, which required integration of local motion signals, was mildly affected in monkeys 2 and 3, and not affected in monkey 1. However, addition of directional noise to this discrimination caused the performance of all monkeys to be permanently disrupted, especially that of monkeys 2 and 3. Finally, direction difference thresholds were elevated by a factor of 2-4 after the lesions in all three monkeys. Many of these deficits were more pronounced during the first 2 months of testing following the lesion. Thus, our results demonstrate that areas within dorsal STS make an important contribution to the performance of various motion perception tasks including the discrimination of small differences in direction and speed, and the perception of global motion in the presence of directional noise. The residual motion perception, even in the monkey with virtually complete removal of areas MT/MST, may suggest either that these tasks are normally mediated in part by cortical areas outside of areas MT and MST, or that the disrupted functions were partially assumed by other cortical areas after lesions.

Animals↗

Opposite dependencies on visual motion coherence in human area MT+ and early visual cortex.

In order to understand the relationship between brain activity and visual motion perception, knowledge of the cortical areas participating in signal processing alone is insufficient. Rather knowledge on how responses vary with the characteristics of visual motion is necessary. In this study, we measured whole brain activity using magnetoencephalography in humans discriminating the global motion direction of a random dot kinematogram whose strength was systematically varied by the percentage of coherently moving dot elements. Spectral analysis revealed 2 components correlating with motion coherence. A first component in the low-frequency domain ( approximately 3 Hz), linearly increasing with motion coherence, could be attributed to visual cortex including human area middle temporal (MT) +. A second component oscillating in the alpha frequency range and emerging after stimulus offset showed the inverse dependence on motion coherence and arose from early visual cortex. Based on these results, we first of all conclude that motion coherence is reflected in the population response of human extrastriate cortex. Second, we suggest that the occipital alpha activity represents a gating mechanism protecting visual motion integration in later cortical areas from disturbing upcoming signals.

Adult↗

Is precise discrimination of low level motion needed for heading discrimination?

Normal observers judge heading well both when moving in a straight line and when moving along a curved path. Judgments of curved path motion require depth variations in the scene while judgments of straight line heading (pure translation) do not. Here we show that a stroke patient who is impaired in low level 2D motion discrimination tasks and cannot accurately judge 3D structure from motion can accurately judge heading for straight line self-motion. This patient is impaired in judgments of curved path self-motion. This suggests that accurate heading judgments for observer translation do not require accurate 2D motion perception or 3D reconstruction of the scene. Judgments of curved path motion appear more dependent on accurate 2D motion perception.

Aged↗

All developmental dyslexic subtypes display an elevated motion coherence threshold.

PURPOSE: Psychophysical studies indicate that many dyslexics have a motion-processing deficit. The purpose of this study was to determine whether elevated motion coherence thresholds correlate with the specific dyslexic subtypes as defined by the Boder classification scheme. METHODS: Twenty-one dyslexics (seven dyseidetics, six dysphonetics, and eight dysphoneidetics) and 19 age- and gender-matched controls participated in the study. The dyslexics were identified by an exclusionary approach and then subtyped with the Adult Dyslexia Test or the Dyslexia Determination Test. Motion coherence thresholds were determined with random dot kinematograms composed of signal dots and noise dots. Signal dots moved either left or right on each trial, whereas noise dots moved in random directions. The percentage of dots that comprised the signal was varied randomly on each trial (0 to 21% in 3% increments). Subjects guessed the direction of signal dot motion on each trial (two-alternative forced-choice task). A 75% correct threshold was determined with a Weibull equation fit to the psychometric function. RESULTS: All three dyslexic subtypes had elevated motion coherence thresholds (t-test; dyseidetics p = 0.01, dysphonetics p = 0.039, dysphoneidetics p = 0.048). CONCLUSION: Motion-coherence deficits are not correlated with a specific dyslexic subtype, but, rather, are common to all subtypes. However, some individuals in each of the dyslexic subtypes were found to have normal motion coherence thresholds, suggesting that other factors must be considered to predict the motion sensitivity deficits found in dyslexia.

Adolescent↗

Studies in flexor tendon wound healing: neutralizing antibody to TGF-beta1 increases postoperative range of motion.

The postoperative outcome of hand flexor tendon repair remains limited by tendon adhesions that prevent normal range of motion. Recent studies using in situ hybridization techniques have implicated transforming growth factor beta-1 (TGF-beta1) in both intrinsic and extrinsic mechanisms of repair. TGF-beta1 is a growth factor that plays multiple roles in wound healing and has also been implicated in the pathogenesis of excessive scar formation. The purpose of this study was to examine the effect of neutralizing antibody to TGF-beta1 in a rabbit zone II flexor tendon wound-healing model. Twenty-two adult New Zealand White rabbits underwent complete transection of the middle digit flexor digitorum profundus tendon in zone II. The tendons were immediately repaired and received intraoperative infiltration of one of the following substances: (1) control phosphate-buffered saline; (2) 50 microg neutralizing antibody to TGF-beta1; (3) 50 microg each of neutralizing antibody to TGF-beta1 and to TGF-beta2. Eight rabbits that had not been operated on underwent analysis for determination of normal flexion range of motion at their proximal and distal interphalangeal joints, using a 1.2-N axial load applied to the flexor digitorum profundus tendon. All rabbits that had been operated on were placed in casts for 8 weeks to allow maximal tendon adhesion and were then killed to determine their flexion range of motion. Statistical analysis was performed using the Student's unpaired t test. When a 1.2-N load was used on rabbit forepaws that had not been operated on, normal combined flexion range of motion at the proximal and distal interphalangeal joints was 93+/-6 degrees. Previous immobilization in casts did not reduce the range of motion in these forepaws (93+/-4 degrees). In the experimental groups, complete transection and repair of the flexor digitorum profundus tendon with infiltration of control phosphate-buffered saline solution resulted in significantly decreased range of motion between the proximal and distal phalanges [15+/-6 degrees (n = 8)]. However, in the tendon repairs infiltrated with neutralizing antibody to TGF-beta1, flexion range of motion increased to 32+/-9 degrees (n = 7; p = 0.002). Interestingly, a combination of neutralizing antibody to TGF-beta1 and that to TGF-beta2 did not improve postoperative range of motion [18+/-4 degrees (n = 7; p = 0.234)]. These data demonstrate that (1) the rabbit flexor tendon repair model is useful for quantifying tendon scar formation on the basis of degrees of flexion between proximal and distal phalanges; (2) intraoperative infiltration of neutralizing antibody to TGF-beta1 improves flexor tendon excursion; and (3) simultaneous infiltration of neutralizing antibody to TGF-beta2 nullifies this effect. Because TGF-beta1 is thought to contribute to the pathogenesis of excessive scar formation, the findings presented here suggest that intraoperative biochemical modulation of TGF-beta1 levels limits flexor tendon adhesion formation.

Animals↗

Lumbar range of motion: reliability and validity of the inclinometer technique in the clinical measurement of trunk flexibility.

STUDY DESIGN: This study examines the reliability and validity of measuring lumbar range of motion with an inclinometer. OBJECTIVES: To find out whether a manual determination of the reference points for measuring lumbar range of motion is as reliable as radiologic determination for positioning the inclinometers, lumbar range of motion was determined in degrees by evaluating radiographs and by using the inclinometer technique of Loebl. SUMMARY OF BACKGROUND DATA: Reliability and validity of the inclinometer technique as a clinical measurement of trunk flexibility were investigated. Fifty-four patients participated in the study. METHODS: Lumbar range of motion measurements were taken with and without radiologic control of the T12 and S1 vertebrae as reference points for positioning of the inclinometers. An interrater correlation was done of the inclinometer techniques of a physician and a physiotherapist. Functional radiographs were investigated in a standing position. Lumbar range of motion measurements based on radiographs and those taken using the inclinometer alone were correlated to validate the inclinometer technique. RESULTS: Lumbar range of motion measurements taken with and without radiologic determination showed a very close correlation (r = 0.93; P < 0.001). Flexion alone also demonstrated a close correlation (r = 0.95; P < 0.001), whereas extension showed a somewhat smaller correlation (r = 0.82; P < 0.001). Total lumbar range of motion (r = 0.94; P < 0.001) and flexion (r = 0.88; P < 0.001) were closely related, as indicated by the interrater correlation, whereas extension (r = 0.42; P < 0.05) showed a lesser correlation. Correlation of the measurements taken radiographically and by inclinometer demonstrated an almost linear correlation for measurements of the total lumbar range of motion (r = 0.97; P < 0.001) and flexion (r = 0.98; P < 0.001), whereas extension (r = 0.75; P < 0.001) did not correlate as well. CONCLUSIONS: The noninvasive inclinometer technique proved to be highly reliable and valid, but the measurement technique for extension needs further refinement.

Adolescent↗

Lumbar range of motion: influence of time of day and individual factors on measurements.

STUDY DESIGN: Influence of time of day and individual factors on the measurements of the lumbar range of motion was investigated. OBJECTIVES: To investigate factors that influence lumbar range of motion. SUMMARY OF BACKGROUND DATA: Twenty-nine patients with chronic low back pain participated in the study. METHODS: The lumbar range of motion was measured by inclinometer technique, Schober sign, modified-Schober sign, and fingertip-to-floor method in the morning, at noon, and in the afternoon. The lumbar range of motion was correlated with patients' gender, age, and body weight. RESULTS: Total lumbar range of motion measured by the inclinometer technique and the modified-Schober sign increased significantly throughout the day from morning to afternoon. Extension lumbar range of motion was shown to be independent of the time of measurement. There were no significant correlations between lumbar range of motion and gender, age, and body weight of the patients. CONCLUSION: For the reliability of a measurement, it is important to investigate lumbar range of motion at the same time of day.

Adolescent↗

A new technique for measuring lumbar segmental motion in vivo. Method, accuracy, and preliminary results.

STUDY DESIGN: A direct method for three-dimensional in vivo spine kinematic studies was developed and used to measure segmental motion patterns in healthy subjects. OBJECTIVES: To validate the new method, and to study the L3-L4 segmental motion patterns for complex dynamic movements. SUMMARY OF BACKGROUND DATA: Conventional two-dimensional and three-dimensional radiographic methods have been used in the past to study spine kinematics. Few studies provided a direct approach to study segmental kinematics. No dynamic recordings of three-dimensional segmental motion patterns have been reported previously. METHODS: In 16 healthy men, Kirschner wires were inserted in the spinous processes of L3 and L4. Electromagnetic tracking sensors were attached to the pins. Motion data recorded during ranging exercises were used with biplanar radiographs to calculate L3-L4 segmental motion patterns. Errors resulting from pin deformation and the dynamic accuracy of the tracking system were investigated thoroughly. RESULTS: The average range of motion for flexion-extension was 16.9 degrees, for one side lateral bending 6.3 degrees and for one side axial rotation 1.1 degrees. Large intersubject variation was found in flexion-extension with values ranging from 7.1 to 29.9 degrees. Coupled motion patterns were found to be consistent among subjects in active lateral bending and inconsistent for active axial rotation. CONCLUSIONS: This new method offers dynamic recording capabilities and a measurement error comparable with stereo radiographic methods. Repetitive ranging experiments are highly reproducible. The range of motion for axial rotation seems overestimated in previous cadaveric studies. Coupling patterns show large variations between individuals.

Electromagnetic Phenomena↗

Noninvasive three-dimensional analysis of cervical spine motion in normal subjects in relation to age and sex. An experimental examination.

STUDY DESIGN: Experimental examination in vivo. OBJECTIVES: To determine the precision of the ultrasound-based Coordinate Measuring System (CMS 50; Zebris Medizintechnik GmbH, D-88316, Isny, Germany) and then to establish a reference range for the active range of motion of the cervical spine in normal test subjects grouped according to age and sex. SUMMARY OF BACKGROUND DATA: Many different devices such as inclinometers, goniometers, potentiometers, computer-aided devices, and radiographic procedures have been developed to examine the range of motion of the cervical spine. All of them have more or less inherent limitations. METHODS: To assess the precision of this examination method, preliminary experiments were performed including intraobserver retest and two-observer repeatability, intraindividual variability, a daily profile, and a comparison between active and passive motions. In the subsequent main experiment 157 persons (86 women and 71 men) were examined during active motion. The sex groups were further subdivided into age groups of 10 years each. A comparison of weight and athletic activity was also performed. RESULTS: The range of motion decreased with increasing age, increasing body weight, and decreasing athletic activity. The rotation in the upper cervical spine increases with age to compensate for the reduced range of motion in the lower levels. Women showed significantly better mobility than men of the same age, only above the age of 70. CONCLUSIONS: The CMS 50 device provides precise reproducible measurements of the active range of motion of the cervical spine in all three planes. Criteria such as age, sex, body weight, and athletic activity influence the range of motion of the cervical spine.

Adult↗

Effects of specimen length on the monosegmental motion behavior of the lumbar spine.

STUDY DESIGN: An in vitro biomechanical analysis of the segmental motion behavior of the same segments in polysegmental (five segments), bisegmental, and monosegmental specimens using sheep lumbosacral spines. OBJECTIVES: To investigate the effect of specimen length on monosegmental motion behavior. These data may be helpful in planning in vitro tests and in comparing results of studies using specimens of different lengths. SUMMARY OF BACKGROUND DATA: The length of spinal specimens used for in vitro stability tests varies greatly, depending on the purpose of the study. Some investigators prefer testing specimens with one adjacent segment on either end of the region of interest. Others favor specimens as short as possible. METHODS: In a first step, seven sheep spine specimens, L3-S1 (note that sheep spines normally have seven lumbar vertebrae), each were tested without preload in a spine-loading apparatus. Alternating sequences of pure lateral bending, flexion/extension, and axial rotation moments (+/-3.75 Nm) were applied continuously. The motion in each single segment was measured simultaneously. Then, these polysegmental specimens were cut into two bisegmental specimens, L3-L5 and L6-S1, and tested in the same way. Finally, another vertebra was removed to obtain two monosegmental specimens, L3-L4 and L7-S1, and to test them as described. RESULTS: In general, the range of motion at L3-L4 and L7-S1 was smaller when tested in polysegmental than in monosegmental specimens. In polysegmental specimens (five segments), the range of motion at L3-L4 and L7-S1 was approximately 80% (range, 70.6-92.5%) and in bisegmental specimens approximately 95% (range, 66.7-100%) of their range of motion measured in monosegmental specimens. Neutral zone and coupled motions showed the inverse behavior. Significant differences were found. However, they were not consistent with either the loading direction or with the specimen length. CONCLUSIONS: For comparison of results, the specimen length should be kept constant within one experiment. Segmental motion behavior of specimens with different lengths should be compared only qualitatively.

Animals↗