Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Computers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79Linked to original sources

Should computed tomography scanning replace lumbar puncture in the diagnostic process in suspected subarachnoid hemorrhage?

The role of lumbar puncture and computed tomography scanning for initial diagnosis of subarachnoid hemorrhage has been evaluated in a retrospective survey of 283 consecutive cases. The material has been divided into early-and late-diagnosed cases with 72 hours after bleeding as the demarcation line between groups. The early-diagnosed cases have been further subdivided into patients exhibiting contraindications for lumbar puncture, patients with a typical history of apoplectic headache, and patients presenting with a diffuse noncharacteristic history. Four initially alert patients suffered neurological deterioration associated with the performance of lumbar puncture, which corresponds to a complication rate of 2.2%. It is concluded that all cases of suspected intracranial hemorrhage in the pediatric age group should be immediately investigated by computed tomography. In old age, individual factors determining the patient's operability overshadows all other aspects. In the intermediate age group lumbar puncture is preferable to diagnose subarachnoid hemorrhage in cases first seen in a late stage, due to both the high rate of falsely suspected cases as well as the poor visualization of degenerating blood in the cerebrospinal fluid by computed tomography. In patients suffering severe apoplectic headache with nuchal rigidity, lumbar puncture is without question superfluous. If neck stiffness is not considered, 4.68 computed tomography investigations per 100,000 individuals would be performed yearly in falsely suspected cases, a diminishingly small cost corresponding to less than 1% of all cranial computed tomography scans performed in this region. Early-diagnosed patients with a diffuse atypical history constitute a small, low risk group for lumbar puncture. It may be acceptable in such patients to diagnose subarachnoid hemorrhage either by means of computed tomography or lumbar puncture, depending on the availability of local computed tomography resources.

Humans↗

Computed tomography of septic joints.

Twenty-six patients with suspected or known septic joints who had been studied by computed tomography were retrospectively reviewed. Eighteen patients (20 joints) proved to have septic arthritis. Computed tomography was advantageous in patients with acute septic arthritis of deep-seated axial joints, such as the hip and sacroiliac, where it demonstrated particular soft tissue swelling as early as 36 hours after the onset of symptoms. In three patients, this finding on computed tomography was helpful in accurately localizing the disease process and facilitating a diagnostic closed needle aspiration biopsy procedure. Four patients had a primary osseous focus of infection in an adjacent epiphyseal region that was documented by computed tomography. Computed tomography was superior to conventional radiology in revealing early articular bone erosion in joints with curved and overlapping articular surfaces in five patients, and resulted in alteration of their treatment. Fat-fluid levels within the suprapatellar bursae were noted in one patient (two joints). Computed tomography is a valuable modality for evaluation of patients with suspected septic arthritis of axial joints, particularly in the acute stage. Furthermore, it is helpful for evaluation of possible periarticular abscess formation and can serve as a guide for a percutaneous drainage procedure. Computed tomography can also be used when articular bone erosion or medullary extension of osteomyelitis is suspected but not fully documented by conventional radiography.

Adult↗

A computational model of reasoning from the clinical literature.

This paper explores the premise that a formalized representation of empirical studies can play a central role in computer-based decision support. The specific motivations underlying this research include the following propositions: Reasoning from experimental evidence contained in the clinical literature is central to the decisions physicians make in patient care. A computational model, based upon a declarative representation for published reports of clinical studies, can drive a computer program that selectively tailors knowledge of the clinical literature as it is applied to a particular case. The development of such a computational model is an important first step toward filling a void in computer-based decision support systems. Furthermore, the model may help us better understand the general principles of reasoning from experimental evidence both in medicine and other domains. Roundsman is a developmental computer system which draws upon structured representations of the clinical literature in order to critique plans for the management of primary breast cancer. Roundsman is able to produce patient-specific analyses of breast cancer management options based on the 24 clinical studies currently encoded in its knowledge base. The Roundsman system is a first step in exploring how the computer can help to bring a critical analysis of the relevant literature to the physician, structured around a particular patient and treatment decision.

Artificial Intelligence↗

Patient reactions to doctors' computer use in general practice consultations.

This paper describes an experimental field study of patient reactions to computer use by doctors during general practice consultations. The computer system offered facilities for the review of medical histories and the entry of individual encounter notes. Questionnaire assessments of patient reactions were obtained from 127 patients who had just consulted a doctor who was using the computer and from 216 control patients for whom conventional procedures had been retained. Contrary to many doctors' concerns no overall negative effects were recorded for patient reactions. There were no differences between the experimental and control conditions with respect to patients' perceptions of the doctors' attentiveness and rapport, patients' satisfaction with information received, their confidence in the treatment received, their expected compliance or post-consultation stress. A relation was however apparent between post-consultation stress and attitudes to the idea of doctors using computers in the consulting room, in which unfavourable attitudes were associated with reports of higher stress, and conversely. The results suggest that patient reactions to the consultation are more affected by which doctor they see than by whether or not the doctor is using a computer. However, the findings relate to only a short period of computer use in an experimental context and the effects of more established computer use remain a matter for further enquiry.

Attitude↗

Computed tomography evaluation of neck node metastases from nasopharyngeal carcinoma.

PURPOSE: To study the role of computed tomography in the pre-therapy evaluation of nasopharyngeal carcinoma. METHODS AND MATERIALS: The computed tomography of 119 new patients of nasopharyngeal carcinoma were evaluated independent of clinical findings for neck node metastases, and then compared with clinical findings. Contrast enhanced axial scans were obtained at 5 mm intervals with the infraorbitomeatal line parallel to the gantry. Scans were obtained from the supra-sellar cistern to the C5 or C6 vertebra for the evaluation of the base of skull, nasopharynx, paranasopharyngeal space and the upper and mid neck. RESULT: The present study confirmed the disparity of nodal extent documented by clinical palpation and computed tomography. Of the 37 patients who have no clinically palpable node (N0), computed tomography showed nodal involvement in 11 (29.7%) of them, and they were up-staged from N0 to N1. Computed tomography showed multiple or bilateral nodes in seven (58.3%) of the 12 patients with AJC N1 disease and they were hence up-staged to N2. All together, there were 28 (23.5%) patients who have no computed tomography evidence of nodal involvement by tumor. In agreement with clinical experience, the most commonly involved nodal groups were the upper internal jugular and upper spinoaccessary, followed by the lateral retropharyngeal. The percentage of nodes which were not clinically palpable was roughly the same for different regions (15-30%), except, as expected, that all the retropharyngeal nodes were not palpable. The risk of harboring retropharyngeal node was proportional to the size of the largest node in the ipsilateral neck. CONCLUSION: A significant proportion of patients with clinically negative neck (N0) or AJC N1 disease will be upstaged by computed tomography, thus supporting its routine use in pre-therapy evaluation of nasopharyngeal carcinoma.

Head and Neck Neoplasms↗

Initial clinical experience with computer-controlled conformal radiotherapy of the prostate using a 50-MeV medical microtron.

PURPOSE: We have described previously a model for delivering computer-controlled radiation treatments. We report here on the implementation and first year's clinical experience with such treatments using a 50 MeV medical microtron. METHODS AND MATERIALS: The microtron is equipped with a multileaf collimator and is capable of setting up and treating a sequence of fixed fields called segments, under computer control. An external computer derives machine parameters for the segments from a three-dimensional treatment planning system, transfers them to the microtron control computer, checks the machine settings before allowing dose delivery to begin, and records the treatment. We describe the patient treatment methodology, portal film acquisition, electronic portal imaging, and quality assurance. RESULTS: Patient treatments began in July 1992, comprising six-segment conformal treatments of the prostate. Using the recorded treatment data, the system performance has been examined and compared to other treatment machines. The average treatment time is 10 min, of which 4 min is for computer-controlled setup and irradiation; the remaining time is for patient positioning and checking of clearances. Long-term reproducibility of computer-controlled setup of the gantry and multileaf position is better than 0.5 degrees and 1 mm, respectively. Termination due to a machine fault has occurred in 5.5% of treatments, improving to 2.5% in recent months. CONCLUSION: Our initial experience indicates that computer-controlled segmental therapy can be performed reliably on a routine basis. Treatment times with the microtron are significantly shorter than with conventional linacs, and setup accuracy is consistent with that needed for conformal therapy. We believe that treatment times can be further improved through software upgrades and integration of electronic portal imaging.

Humans↗

A computer-controlled conformal radiotherapy system. I: Overview.

PURPOSE: Equipment developed for use with computer-controlled conformal radiotherapy (CCRT) treatment techniques, including multileaf collimators and/or computer-control systems for treatment machines, are now available. The purpose of this work is to develop a system that will allow the safe, efficient, and accurate delivery of CCRT treatments as routine clinical treatments, and permit modifications of the system so that the delivery process can be optimized. METHODS AND MATERIALS: The needs and requirements for a system that can fully support modern computer-controlled treatment machines equipped with multileaf collimators and segmental or dynamic conformal therapy capabilities have been analyzed and evaluated. This analysis has been used to design and then implement a complete approach to the delivery of CCRT treatments. RESULTS: The computer-controlled conformal radiotherapy system (CCRS) described here consists of a process for the delivery of CCRT treatments, and a complex software system that implements the treatment process. The CCRS system described here includes systems for plan transfer, treatment delivery planning, sequencing of the actual treatment delivery process, graphical simulation and verification tools, as well as an electronic chart that is an integral part of the system. The CCRS system has been implemented for use with a number of different treatment machines. The system has been used clinically for more than 2 years to perform CCRT treatments for more than 200 patients. CONCLUSIONS: A comprehensive system for the implementation and delivery of computer-controlled conformal radiation therapy (CCRT) plans has been designed and implemented for routine clinical use with multisegment, computer-controlled, multileaf-collimated conformal therapy. The CCRS system has been successfully implemented to perform these complex treatments, and is considered quite important to the clinical use of modern computer-controlled treatment techniques.

Equipment Design↗

Efficiency of a computer network in the administrative and medical field of cardiac surgery. Concept of and experience with a departmental system.

We report on a pilot project implementing electronic data processing (EDP) in the Department of Cardiac Surgery of the University of Heidelberg, based on a concept of complete integration of a medical database system into everyday clinical routine. A computer network was installed and has been in use since August 1988 as a department system supporting both the administrative and the medical side of the department (documentation, information, research, archives, organization, secretarial office, billing, statistics and communication). With a computer-assisted documentation system and standardized data acquisition, nearly 80% of letters and reports on operations are written automatically without any further need for dictation. Automatic computer controlled follow-up has been initiated to cover all patients operated on in our hospital. The complete integration of a new method of clinical documentation and EDP into everyday clinical routine and the extensive use of computer-derived information have proved to be significant advances. Our practice of computer-assisted information management and departmental organization serves the patient by; (1) providing up-to-date valid information for the clinical staff; (2) establishing and stabilizing contact and communication with physicians elsewhere, e.g. cardiologists; (3) facilitating pre- and postoperative contact with patients; (4) helping to optimize medical treatment by routine statistical data analysis (quality assurance); (5) creating a clear and logical computer-assisted departmental organizational structure; (6) permitting long-term evaluation of operative results based on a standardized computer-controlled follow-up procedure; (7) improving the quality of medical and administrative data.

Cardiac Surgical Procedures↗

Detection of coronary artery stenosis using 40-channel computed tomography with multi-segment reconstruction.

Coronary angiographic studies performed with 16-channel multidetector computer tomographic scanners have demonstrated accurate detection of coronary vessel stenosis but are limited by a significant number of non-evaluable segments. To date, only single-center experience with multidetector computer tomography has been reported. We performed a prospective, blinded study at 2 institutions to determine the feasibility and diagnostic accuracy of coronary angiography using 40-channel multidetector computer tomography with multi-segment reconstruction for the detection of obstructive coronary artery disease (CAD). Multidetector computer tomographic studies were performed in 85 patients who were referred for invasive coronary angiography with clinically suspected CAD. Datasets were analyzed by blinded, independent review. Of 1,145 segments that were suitable for analysis as determined by angiography, 1,045 (91.3%) were evaluable on multidetector computer tomography. Segment-based sensitivity, specificity, and positive and negative predictive values for detecting > or =50% luminal stenoses were 86%, 97%, 75%, and 97%, respectively. The area under the receiver-operating characteristic curves for the detection of > or =50% angiographic stenosis by multidetector computer tomography was 0.94. In a patient-based analysis, the sensitivity, specificity, and positive and negative predictive values for detecting subjects with > or =1 segment with > or =50% stenosis were 98%, 93%, 94% and 93%, respectively. In conclusion, coronary angiography using 40-channel multidetector computer tomography with multi-segment reconstruction accurately detects coronary segments and patients with obstructive CAD, with a small number of non-evaluable cases.

Coronary Angiography↗

Membrane computing: brief introduction, recent results and applications.

The internal organization and functioning of living cells, as well as their cooperation in tissues and higher order structures, can be a rich source of inspiration for computer science, not fully exploited at the present date. Membrane computing is an answer to this challenge, well developed at the theoretical (mathematical and computability theory) level, already having several applications (via usual computers), but without having yet a bio-lab implementation. After briefly discussing some general issues related to natural computing, this paper provides an informal introduction to membrane computing, focused on the main ideas, the main classes of results and of applications. Then, three recent achievements, of three different types, are briefly presented, with emphasis on the usefulness of membrane computing as a framework for devising models of interest for biological and medical research.

Algorithms↗

Multidetector-row computed tomography in the planning of abdominal perforator flaps.

An accurate preoperative evaluation of the vascular anatomy of the abdominal wall is extremely valuable in improving the surgical strategy in abdominal perforator flaps. The multidetector-row computer tomography offers thin slice coverage of extended volumes with an extremely high spatial resolution. From October 2003 to December 2004, 66 female patients had breast reconstruction surgery in our department using the deep inferior epigastric artery perforator flap. Our multidetector-row computer tomography studies were performed using a 16-detector-row computer tomography scanner. The image assessment was carried out using the following protocol: we first identified the best three perforators from each side of the abdomen. Then we conducted a three-dimensional reconstruction of the abdomen by identifying exactly where the three best perforators emerged from the rectus abdominis fascia. We then transferred the data obtained from the image to the patient using a coordinate system. In addition, we also placed the dominant perforators in the patient by using a conventional hand-held Doppler. During the operation we compared intra-operative findings, Doppler results and computer tomography outcomes. Neither false positive nor false negative results were found in the computer tomography outcome. Multidetector-row computer tomography provides us with an easy method of interpreting the virtual anatomic dissection in three dimensions. It has high sensitivity and specificity and provides a good quality evaluation of the perforator vessels. This information allows reduction of operating time and safer performance of surgery. The multidetector-row computer tomography is a highly effective tool in the preoperative study of abdominal perforator flaps.

Abdomen↗

Diagnostic performance of a computer-based ECG rhythm algorithm.

We examined the accuracy of computer-based rhythm interpretation from one electrocardiograph manufacturer (GE Healthcare Technologies MUSE software 005C) in 4297 consecutive recordings in a university hospital setting. Overreading was performed by either of 2 experienced cardiologists, and all disagreements with the initial computer rhythm statement were reviewed by the second cardiologist to achieve physician consensus used as the "gold standard" for rhythm diagnosis. Overall, 13.2% (565/4297) of computer-based rhythm statements required revision, but excluding tracings with pacemakers, the revision rate was 7.8% (307/3954), including 3.8% involving the primary rhythm diagnosis and 3.9% involving definition of ectopic complexes. The false-negative rate for sinus rhythm was only 1.3%, but a computer diagnosis of sinus rhythm was incorrect in 9.9% of other rhythms. The false-negative rate for atrial fibrillation was 9.2%, whereas a computer diagnosis of atrial fibrillation was incorrect in 1.1% of other rhythms, including sinus. Computer diagnosis of paced rhythms remains problematic, and physician overreading to correct computer-based electrocardiogram rhythm diagnoses remains mandatory.

Algorithms↗

Integrated computed tomography-positron emission tomography in patients with potentially resectable malignant pleural mesothelioma: Staging implications.

BACKGROUND: Integrated computed tomography-positron emission tomography imaging with coregistration of anatomic and functional imaging data may improve the accuracy of malignant pleural mesothelioma staging. We evaluate the use of integrated computed tomography-positron emission tomography in patients with malignant pleural mesothelioma who are being considered for extrapleural pneumonectomy. METHODS: Twenty-nine patients with malignant pleural mesothelioma who were judged to be candidates for extrapleural pneumonectomy after clinical and conventional radiologic evaluation underwent whole-body integrated computed tomography-positron emission tomography and pathologic staging. Two reviewers blinded to the results of clinical and pathologic staging retrospectively evaluated computed tomography, positron emission tomography, and coregistered computed tomography-positron emission tomography images. Staging was performed according to the International Mesothelioma Interest Group TNM staging system. Histopathology and/or results of further radiologic evaluation or follow-up served as the reference standard. RESULTS: Integrated computed tomography-positron emission tomography provided additional information in 11 of 29 patients that precluded extrapleural pneumonectomy. The overall tumor stage was correctly classified in 21 of 29 patients. The tumor stage was correctly determined in 15 of 24 patients, 6 of whom had T4 (nonresectable) disease. The node stage was accurately determined in 6 of 17 patients. Extrathoracic metastases not identified by routine clinical and conventional radiologic evaluation were detected in 7 of 29 patients and were found to be diffuse (n = 2) or solitary (n = 5). CONCLUSIONS: Integrated computed tomography-positron emission tomography increases the accuracy of malignant pleural mesothelioma staging and is important in determining the appropriate therapy in patients being considered for extrapleural pneumonectomy.

Adult↗

Detection of coronary complications after the arterial switch operation for transposition of the great arteries: first experience with multislice computed tomography in children.

OBJECTIVE: The main cause of long-term morbidity and mortality after a successful arterial switch operation for transposition of the great arteries is complications at the ostial segments, proximal segments, or both of the retransferred coronary arteries. The purpose of this study was to investigate the clinical usefulness of multislice computed tomographic angiography in detecting ostial and proximal coronary lesions in children having undergone the arterial switch operation for transposition of the great arteries. METHODS: Forty-nine children (aged 8.5 +/- 3.9 years) operated on for transposition of the great arteries with the arterial switch operation (follow-up, 8.3 +/- 3.6 years) underwent systematic selective conventional and multislice computed tomographic angiography. The ability of multislice computed tomography in detecting stenosis and other modifications of the coronary arteries' course was analyzed by 2 independent investigators. RESULTS: Multislice computed tomography, as compared with selective conventional coronary angiography, permitted assessment of ostial and proximal coronary segments in every patient. It correctly detected the 4 (8.1%) patients with significant coronary lesions (1 with ostial and 3 with proximal coronary stenosis) that had been identified by means of conventional angiography. Multislice computed tomography clearly showed an abnormal course of the coronary artery between the great arteries with compression of the ostial (1 patient) and proximal (3 patients) segments of the retransferred coronary arteries. CONCLUSION: These results indicate that multislice computed tomographic angiography is fully accurate in detecting ostial coronary artery stenoses, proximal coronary artery stenoses, or both in pediatric patients having undergone the arterial switch operation for transposition of the great arteries. Our results suggest that multislice computed tomography could be used as a screening technique for detecting coronary complications in the follow-up of the arterial switch operation before having recourse to conventional angiography.

Child↗

Impact of graphical user interface screen features on computer task accuracy and speed in a cohort of patients with age-related macular degeneration.

PURPOSE: To investigate the impact of graphical user interface screen features on computer task performance in patients with age-related macular degeneration (AMD). DESIGN: Interventional case series. METHODS: Eighteen patients with visual impairment due to AMD were recruited from the Bascom Palmer Eye Institute Low Vision Clinic. Each patient underwent evaluation of visual acuity using the Early Treatment Diabetic Retinopathy Study protocol, contrast sensitivity using a Pelli-Robson chart, binocular simultaneous visual field using the Esterman program on an automated perimeter, and color vision using Farnsworth D-15. Each subject then completed computer icon identification tasks while the following screen features of the graphical user interface were varied: size of icons displayed, icon set size (number of icons displayed), and background color. Each patient performed all 125 computer tasks with each of five icon sizes (9.2 mm, 14.6 mm, 23.2 mm, 36.8 mm, 58.3 mm), each of five icon set sizes (2, 3, 4, 5, 6), and each of five different background colors (black, white, red, green, blue) in a randomly ordered fashion. Relationships between computer task performance (accuracy and speed) and graphical user interface screen features were studied. RESULTS: Icon size and icon set size are significantly associated with computer task accuracy (P <.001), whereas background color is not a significant predictor of task accuracy (P =.63). The impact of icon size on accuracy is nonlinear, with the data indicating that no additional improvement in accuracy is associated with increasing the icon size beyond 23.2 mm. The impact of icon set size on accuracy is linear, with a smaller icon set size significantly associated with greater computer accuracy. A larger icon size is significantly associated with a shorter time to task completion (P =.001); this relationship is largely linearly related to icon size. There was no significant impact of background color (P =.11) or set size (P =.37) on time to task completion. CONCLUSIONS: Modifications of graphical user interface design may permit improved computer task performance among patients with visual impairment due to AMD.

Adult↗

Orbital fracture evaluation by coronal computed tomography.

Coronal computed tomography produces orbital scans in a plane that is analogous to Caldwell-view x-ray films. Coronal computed tomography permits simultaneous visualization of the orbital walls and the orbital soft tissues, including all extraocular muscles. Using coronal computed tomography, we studied a series of patients with radiographically proven orbital floor fractures. We studied in detail three of these patients, one with a linear orbital floor fracture, one with a depressed orbital floor fracture, and one with a severely comminuted orbital floor. In two patients, coronal computed tomography showed inferior rectus muscle entrapment, which was confirmed at the time of surgery. In each patient, some bone fragments could be seen more discreetly on coronal computed tomography than on conventional polytomes. Coronal computed tomography may be used to help confirm extraocular muscle entrapment in patients with orbital floor fractures. Coronal computed tomography can also be used to examine patients with possible intraorbital foreign bodies, unexplained reduction of vision, or severely displaced bone fragments.

Adult↗

A computer education program to improve physician awareness of rehabilitation hospital charges.

OBJECTIVE: To quantify physician knowledge of hospital charges and determine if computer fiscal feedback would improve physician awareness of hospital charges. DESIGN: Comparison of physicians' knowledge of hospital charges before and 6 months after the instigation of a computer feedback educational program. PARTICIPANTS AND SETTING: All physicians (attendings, residents, and fellows) at a large academic rehabilitation hospital. INTERVENTION: After surveying physicians' knowledge of hospital charges, the billing fees for some items were placed on the computer ordering menu so that these charges were viewed when orders were made by physicians. MAIN OUTCOME MEASURES: Error in physician charge estimates before and after computer education program, and physician confidence in charge estimates. RESULTS: The baseline survey found that physicians had poor awareness of hospital charges, regardless of ordering frequency, relative charge for the item, or physician experience. Physicians expressed little confidence in their knowledge of the charges and were twice as likely to underestimate than to overestimate charges. Six months after the implementation of a computer feedback educational program, improvement was seen in the awareness of hospital charges for all imaging studies and most laboratory tests. Fiscal awareness of items that had not been included in the computer feedback also showed some small improvement. Physicians' confidence in their knowledge of fees improved. Physicians indicated the program was beneficial and should be expanded to include fiscal information on more services. CONCLUSIONS: Immediate computer feedback of hospital charges improves physicians' fiscal awareness and may lead to their practice of more cost-efficient medicine.

Computer-Assisted Instruction↗

How fibers subserve computing capabilities: similarities between brains and machines.

Can the principles underlying the design of computers help to explain the cognitive capabilities of the human brain? This chapter shows that these principles can provide insight into the capabilities of the human cerebellum, the internal structure of which bears a remarkable resemblance to the design of a versatile computer. In computers, information processing is accomplished both by the hardware in the system (its circuitry) and by the software (the communication capabilities inherent in its circuitry), which is combination can produce a versatile information-processing system, capable of performing a wide variety of functions, including motor, sensory, cognitive, and linguistic ones. Such versatility of function is achieved by computer hardware in which many modules of similar circuits are organized into parallel processing networks; this structural organization is exemplified in the cerebellum by its longitudinal modules of similar circuits, which are arrayed in parallel zones throughout the structure. On the basis of this known cerebellar "hardware," it is possible to investigate the "software" capabilities inherent in the circuitry of the modules. Each module in the lateral cerebellum seems able to communicate with the cerebral cortex by sending out signals over a segregated bundle of nerve fibers, which is a powerful way of communicating information. We show why this bundling of fibers can enable the cerebellum to communicate with the cerebral cortex (including the prefrontal cortex) at a high level of discourse by using internal languages that are capable of conveying complex information about what to do and when to do it. We propose that such communication activity is reflected in the activation obtained on functional imaging of the cerebro-cerebellar system during the performance by humans of complex motor, sensory, cognitive, linguistic, and affective tasks. Further, we propose a new way of analyzing such cerebro-cerebellar activation, in order to ascertain whether the cerebellar circuitry can (like the circuitry in a versatile computer) perform a wide repertoire of computations on this wide range of information. It seems important to ascertain whether cerebellar circuitry is versatile in its computing capabilities because the demonstration of such versatile capabilities would enable theorists to resolve many of the current controversies about cognitive processing in the mammalian brain.

Animals↗