Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79Linked to original sources

Allergic contact dermatitis to artificial fingernails prepared from UV light-cured acrylates.

BACKGROUND: Contact dermatitis from artificial nails made from self-curing acrylic resins is occasionally reported. Recently, UV light-cured products introducing new acrylics have become available. OBJECTIVE: Our purpose was to identify relevant allergens in commercial light-curing products by patch tests and to evaluate the efficacy of "hypoallergenic" products by inclusion into the test series. METHODS: Patients wearing photobonded acrylic nails who had perionychial and subonychial eczema were patch tested with an acrylate battery and "hypoallergenic" commercial products. RESULTS: Triethyleneglycol dimethacrylate, hydroxyfunctional methacrylates, and (meth)-acrylated urethanes proved to be relevant allergens in photobonded nail preparations. Methacrylated epoxy resin sensitization was not observed. All "hypoallergenic" products provoked positive reactions. CONCLUSION: The omission of irritant methacrylic acid in UV-curable products does not reduce the high sensitizing potential of new acrylates. In contrast to the manufacturers' declarations, all "hypoallergenic" products continue to include acrylate functional monomers and therefore continue to cause allergic sensitization.

Acrylates↗

Surface quality achieved by polishing and by varnishing of temporary crown and fixed partial denture resins.

STATEMENT OF PROBLEM: Studies have suggested that coating a temporary restoration with varnish material could replace time-consuming polishing procedures needed for achieving an optimally smooth surface. PURPOSE: This study examined the surface roughness of acrylic resins after having been polished or coated with different varnish materials. MATERIAL AND METHODS: A total of 360 cylindrical specimens were fabricated from 9 brands of resin. One surface on each specimen was machined flat and subsequently either polished with rubber polishers or coated with 1 of 9 varnishes. Selected specimens were subjected to thermal cycling (5 degrees C to 55 degrees C, 2000 cycles). Surface quality was assessed by means of a profilometer and by SEM examination. RESULTS: Polished specimens had average surface roughness values (Ra) of 0.8 microm; differences in roughness between materials were small, but statistically significant. Type of coating had a significant influence on surface quality. Depending on the combination of materials used, the coating produced both smoother and rougher surfaces than polishing (0.4 microm < Ra < 4.6 microm). Five coatings were deemed not to be clinically applicable because of poor wetting properties. Thermal cycling did not significantly influence surface quality, but caused minute cracks in the cyanoacrylate coating. CONCLUSION: In regard to surface quality and applicability, the use of varnishes on temporary restorations is not advisable.

Acrylic Resins↗

Custom stent fabrication for free gingival grafts around osseointegrated abutment fixtures.

The Branemark system of osseointegrated dental implants offers a viable treatment alternative for patients whose conventional prostheses have not been successful. However, the unkeratinized, loosely attached nature of the oral mucosa through which the fixtures may pass often presents a region of easy trauma. A free gingival graft of keratinized tissue from the hard palate can be substituted for these tissues. The success of the graft is dependent upon early healing and protection of the recipient site. This protection can be accomplished by fabrication and use of a custom acrylic resin tissue stent extended beyond the borders of the surgical site.

Acrylic Resins↗

Investing procedures for immediate laboratory remounting of removable partial dentures.

Remounting removable partial dentures in the laboratory after deflasking and before clinical placement has several advantages. This modified investment procedure makes it easy to remount partial dentures after processing. Preliminary adjustments of laboratory errors and inaccuracies caused by dimensional changes in heart processing of acrylic resin may be made before the appointment with the patient.

Acrylic Resins↗

Assessment of uncertainty in mechanical testing of dental materials.

A generally valid and commonly accepted model for assessing the reliability of measurements in the field of medical and dental materials is hard to establish. The results obtained in different laboratories sometimes are difficult to compare. We therefore discuss different assessors of the quality of measurements from both conceptual and operational perspectives. Especially addressed are the customary terms accuracy, error and uncertainty, these terms that often are mixed rather confusingly in expressing the quality of experiments. The aim of this work is to present the advantages of choosing uncertainty rather than error as the appropriate assessor of the reliability of measurements. The transverse deflection testing of four denture-base acrylic resins served as an experimental basis for the analysis.

Acrylic Resins↗

Effect of flexural load cycling on microleakage of extended root caries restorations.

This study evaluated the microleakage of resin-modified glass ionomer, flowable compomer and flowable resin composite restorations on a Class V cavity of simulated advanced root caries under a flexural load cycling condition. Thirty-six non-carious human maxillary premolars were mounted in cylindrical acrylic resin molds. The cavities were prepared in the proximal root surface, from the middle of the buccal surface to the middle of the lingual surface, approximately 1 mm below the cemento-enamel junction, 2 mm axial width and 1.2 mm in depth. The teeth were randomly assigned to one of three groups with 12 teeth in each group: Group 1: Cavity conditioner and Fuji II LC (GC America), Group 2: Prime & Bond NT and Dyract Flow (Caulk-Dentsply), Group 3: Excite and Tetric flow (Ivoclar/Vivadent). Specimens were settled laterally on a fatigue-testing machine that was adjusted to deliver a force of 60N. The specimens were load cycled at 1 Hz for 5000 cycles, placed in a staining solution and sectioned to evaluate microleakage penetration. Results indicate that the coronal and gingival margins showed significant microleakage differences among the three restorations (p<0.05). At the coronal margin, there was no significant difference between Groups 2 and 3. At the gingival margin, there was no significant difference between Groups 1 and 2. It was concluded that the marginal sealing ability of a flowable resin composite under a flexural cycling load was better than in other selected materials and that flowable resin composite with dentin adhesive was a desirable alternative for root caries restorations extended to the proximal surface.

Acrylic Resins↗

Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments.

PURPOSE: This study evaluated the deformation of a metallic framework connected to 15 stone casts fabricated using 3 transfer techniques to determine the most accurate impression procedure. MATERIALS AND METHODS: Five stone casts were made from polyether impressions of an epoxy resin master model for each transfer technique. Group 1 samples were created by the direct splinted technique (square transfer copings splinted with carbon steel pins and autopolymerizing acrylic resin, custom tray); group 2 samples were made by the direct nonsplinted technique (square transfer copings, custom tray); and group 3 samples were fabricated using the indirect technique (tapered transfer copings, custom tray). Sixteen strain gauges were fixed on the framework to measure the degree of framework deformation for each stone cast. Pairs of strain gauges placed opposite each other constituted 1 channel to read deformation (half Wheatstone bridge). Deformation readings were collected at the 4 segments between abutments in 4 directions (anterior, posterior, superior, and inferior). Deformation data were analyzed using analysis of variance and the Tukey test at the .05 and .01 levels of significance. RESULTS: Group 1 samples allowed the most accurate reproduction of analog position compared to the samples made using the other techniques. No significant difference was found between the direct nonsplinted (group 2) and indirect (group 3) techniques. DISCUSSION: Although some studies have evaluated transfer techniques with similar methodology, this study demonstrated the most suitable strain gauge setup to record framework deformations in all directions and simultaneously offset the effects of temperature variation. CONCLUSIONS: The direct splinted technique was the most accurate transfer method for multiple abutments compared to direct nonsplinted and indirect techniques.

Acrylic Resins↗

A clinical evaluation of materials used in registering interjaw relationships.

Three recording media used to relate stone casts for 15 dentate patients were compared for accuracy. Interjaw relationships at the maximum intercuspation position and the retruded contact position were recorded using impression plaster, wax, and Duralay acrylic resin. A Lucia programming jig was used in the retruded contact position. The vertical distance and horizontal deviation between the casts were measured from reference points on the casts using each recording material. The average percentage differences between the recording materials were calculated. Hand articulation was the most accurate method of relating the casts at maximum intercuspation. The most accurate recording medium was impression plaster, followed by dental wax and Duralay resin at the maximum intercuspation and retruded contact positions.

Acrylic Resins↗

A survey of the pre-bonding preparation of denture teeth and the efficiency of dewaxing methods.

OBJECTIVES: Denture tooth debonding remains a significant problem, with the surface condition of the tooth playing a pivotal role. The purpose of this investigation was to determine the methods used in tooth preparation. The efficiency of wax removal from teeth using a range of water temperatures was also investigated. METHODS: (a) A postal survey on the methods of denture tooth preparation, prior to denture processing, was conducted amongst dental instructors in prosthodontic departments of dental schools in Great Britain and Ireland. (b) Tooth surfaces contaminated with fluorescence wax were subjected to agitation in water at a range of temperatures and the surfaces examined under ultraviolet radiation. RESULTS: (a) The majority of operators did not use a solvent for the removal of the wax film from the teeth. Modification of the tooth ridge lap surface was carried out by 52% of the respondents on initial processing but increased to 85% when rebonding teeth. (b) Dewaxing denture teeth at a range of water temperatures showed wax retention on the tooth surfaces up to 90 degrees C. Rough surfaces retained more wax than smooth surfaces. Wax eliminator was shown to be necessary for complete wax removal. CONCLUSIONS: No standard technique exists amongst dental instructors for the preparation of denture teeth prior to acrylic resin polymerization. The use of a wax solvent is to be recommended.

Acrylic Resins↗

Repair of denture base resin using woven metal and glass fiber: effect of methylene chloride pretreatment.

STATEMENT OF PROBLEM: A durable repairing system for denture base fracture is desired to avoid recurrent fracture. Purpose. This study evaluated the strength and modulus of elasticity of repaired acrylic specimens reinforced with various processes. MATERIAL AND METHODS: Transverse strength and modulus of elasticity of repaired acrylic denture base specimens were evaluated with a 3-point bending test and compared with a heat-polymerized control. Autopolymerizing acrylic resin was used with woven metal fiber and glass fiber with and without methylene chloride surface treatment (n = 6 per group). The specimens were cut in half and fixed in a metal mold to obtain a space for placing the repairing resin. A cavity was prepared when metal or glass fiber was used. All specimens were stored in 37 degrees C distilled water for 48 hours before the test. All data were statistically analyzed with 1-way ANOVA, and differences among groups were analyzed with Fisher test (P< or =.05). RESULTS: The mean value of the transverse strength for the control was 87.2 MPa. The specimens repaired by glass fiber with methylene chloride surface treatment exhibited the highest transverse strength (96.8 MPa), which was significantly higher than that of the control (P< or =.05). The elastic modulus of the specimens repaired by glass fiber with methylene chloride surface treatment (4189.3 MPa) was significantly greater than that of the control (2683.7 MPa) at a 95% level of confidence. The values of transverse strength and elastic modulus were highest when the surface treatment was combined with a reinforcing glass fiber. CONCLUSION: Reinforcement with glass fiber and methylene chloride pretreatment produced transverse strength and a modulus of elasticity higher than the control.

Acrylic Resins↗

Stabilizing a removable partial denture framework on the master cast.

This technique aids the dentist in obtaining stable removable partial dentures. Failure to fill the space between the tissue stops of the retention mesh and the dental cast with cold-cure acrylic resin may result in the distortion and displacement of the removable partial denture framework during processing.

Acrylic Resins↗

Ability of enzymes to remove Candida.

Infection by C. albicans is a significant cause of denture stomatitis. Therefore, the results of this study, which demonstrated that yeast lytic enzymes and proteolytic enzymes removed C. albicans from acrylic resin surfaces, suggest that these compounds are potentially useful denture cleansers.

Acrylic Resins↗

Interim esthetic restorations in conjunction with anterior implants.

This article describes 2 procedures that can be used to provide acceptable anterior esthetics from the time of extraction, through implant placement and uncovering, until the completed implant-supported and retained crown is inserted. The first procedure presents a simple treatment option to prevent esthetic embarrassment immediately after implant placement. The second procedure uses a claspless, acrylic resin temporary removable partial denture to overcome many of the esthetic problems attendant with immediate replacement.

Acrylic Resins↗

[Polymerization exothermal reaction of dental prosthetic resin for temporary crowns. A comparative evaluation].

BACKGROUND: The aim of the present study is to evaluate the risk of a possible thermal stress of the pulpal tissue during the fabrication of a temporary crown when using the direct technique. METHODS: For this study, 7 different brands of acrylic resin including Acrylic type and Bis-Gma type have been tested. At this purpose one series of in vitro experimental trials were performed. The trials have evaluated the temperature increase inside the pulp chamber of an extracted tooth during the fabrication of a provisional crown. The temperatures reached by the resins tested were measured using a digital thermometer connected with a thermal probe. RESULTS: The temperatures measured during the experimental trials show a different ability by the 7 tested resins to produce heat. Indeed, while the polymethylmethacrylate resins show higher increments rate of temperature, the Bis-Gma resins produce less dramatic increase along with lower temperatures peaks. CONCLUSIONS: Testing the 7 different resins has proved that there is an actual risk to cause lesions to the pulpal tissue during the placement of a provisional crown when using the direct technique. The materials which show a reduced exothermal reaction are: IsoTemp and Protemp II.

Crowns↗

Resin registration for interocclusal records.

An ideal material for registering interocclusal records should (1) have reproductive accuracy, (2) be easy to handle, (3) offer no resistance to closure during the registration, (4) be rigid when set, and (5) have a fair degree of hardness when set. The acrylic resin, Duralay, has these qualities. Techniques for utilizing Duralay to register interocclusal records for unilateral restorations, bilateral restorations, full-arch restorations, as well as fixed and removable restorations in the same arch have been demonstrated.

Acrylic Resins↗