Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Titanium”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

A clinical study of space closure with nickel-titanium closed coil springs and an elastic module.

A previous study has shown that a 150-gram nickel-titanium closed coil spring (Sentalloy, GAC International Inc.) closed spaces more quickly and more consistently than an elastic module (Alastik, Unitec/3M). This study used the same friction sensitive sliding mechanics of pitting the six anterior teeth against the second bicuspid and first molars, to examine the rate of space closure of 100-gram and 200-gram nickel-titanium closed coil springs. The results for the three springs and elastic module were compared. The nickel-titanium closed coil springs produced a more consistent space closure than the elastic module. The 150- and 200-gram springs produced a faster rate of space closure than the elastic module or the 100-gram spring. No significant difference was noted between the rates of closure for the 150- and the 200-gram springs.

Adolescent↗

Histological findings of bone remodeling around smooth dental titanium implants inserted in rabbit's tibias.

Nowadays, there are many kinds of implants with different covering layers. The aim of these wide spectra is to discover the material that has the best possible biocompatibility. The presence of so many kinds of covering layers indicates that this aim has not been reached until now. The implant anchorage in the bone is very important for the stability of the element that has to support much pressure when under use. As it is known, the implant/bone interface does not present the ideal result expected by all professionals. In the laboratory there are possibilities of researching many kinds of implants--under different techniques of insertion. This will lead to the best methods and materials available. Titanium is the basic material used by many authors and needs no further discussion. So far it is the material with the best biocompatibility. The aim of this work is to observe and study the bone healing in the interface between a titanium implant and bone under light microscopic technique. Commercial pure titanium implants with a smooth surface were inserted in rabbit's tibias where they remained for eight weeks. The amount of bone inside the implant threads was quantified by the use of a stereologic method. The histological results indicated that an intense remodeling process of the cortical bone was found close to the implant surface and in the stereometry a higher amount of the new bone formation was also observed in the cortical tibia at the implant/bone interface.

Animals↗

Water leaching of titanium from ore flotation residue.

Copper ore tailings were tested for the stability of titanium submitted to water leaching in three different reactor systems (agitated vessel, bioreactor and percolated fixed-bed column). For each of these systems, titanium extraction did not exceed 1% of the available metal. Biomass removed from ore residue adsorbed a small part of the titanium with sorption capacities below 20-30 mg g(-1), but most of this biomass was sequestered in the ore residue. Oxygen and carbon dioxide concentrations were monitored and changes in concentration correlated with bacteria development at the initial stage of the process and to fungal development in the latter stages.

Adsorption↗

Titanium complexes in cancer treatment.

A series of complexes containing titanium, Ti, as a metal center has shown to possess a wide spectrum of antitumor properties. This series belongs to the non-platinum metal antitumor agents which has been developed mainly in the past 20 years. The bis(beta-diketonato)titanium(IV) and titanocene derivatives appear to offer a different alternative for cancer chemotherapy which do not follow the rationale and mechanism of action of the platinum complexes. The hydrolysis of these complexes in aqueous and pseudo aqueous solutions is discussed and the interaction studies of titanium complexes with biomolecules are also presented to unravel the mechanism of action at molecular levels.

Animals↗

Transcatheter manipulation of asymmetrically opened titanium Greenfield filters.

PURPOSE: The problem of asymmetric opening of the modified hook titanium Greenfield inferior vena cava filter necessitating transcatheter manipulation was evaluated in a retrospective study. PATIENTS AND METHODS: Titanium Greenfield filters were placed in 166 patients over a 36-month period. The radiographic reports of all patients were reviewed to identify cases in which the filter failed to open symmetrically after deployment and catheter or wire manipulation of the filter was performed. The reports and angiograms from these patients were reviewed with respect to the circumstances surrounding filter placement and methods to achieve more symmetric opening. RESULTS: Transcatheter manipulation of asymmetrically opened filters was performed in 15 of 166 cases (9%). In 12 of these patients, acceptable and uneventful opening of the filter was achieved with a guide wire, pigtail catheter, or occlusion balloon catheter. In one case manipulation only partly improved orientation of the limbs, while in another case successful manipulation was complicated by distal migration. In the final case, the asymmetric filter covered only part of the lumen of the vena cava despite manipulations and a second filter was placed for optimal caval interruption. No specific cause for incomplete expansion was identified in any case. CONCLUSION: Marked asymmetry in opening of the modified hook titanium Greenfield filter that warrants manipulation occurs infrequently, but recognition and proper management may be important to ensure optimal caval interruption.

Catheterization, Central Venous↗

IVC filter tilt and asymmetry: comparison of the over-the-wire stainless-steel and titanium Greenfield IVC filters.

PURPOSE: A comparison of tilting, caval coverage, asymmetry, and insertion problems with the over-the-wire stainless-steel and titanium versions of the Greenfield filter. MATERIALS AND METHODS: The study compared 104 stainless-steel and 141 titanium Greenfield inferior vena cava (IVC) filter insertions. The angle the sheath and deployed filter made relative to the cava, as well as filter strut distribution, were determined from spot films. The proportionate caval coverage was computed from the cavogram (anteroposterior projection). Mean filter tilts, subgrouped by insertion site, and caval coverage were compared with the Student t test, whereas strut patterns were analyzed with a contingency table. RESULTS: The filter caval and sheath caval angles correlated. The filter caval angles varied with insertion site, but were lowest with a right jugular approach. Caval coverage was identical with both designs. The stainless-steel version resulted in a more uniform distribution of struts in comparison with the titanium version. The incidence of insertion problems was not significantly different between the filter types. CONCLUSIONS: While IVC filter tilting was not improved with the newer design, the pattern of struts was more uniformly symmetric with the stainless-steel device. The right jugular insertion site was associated with the lowest filter caval angles and the most symmetric pattern of struts.

Chi-Square Distribution↗

Morphologic effects on L929 fibroblasts of titanium tetrafluoride application.

OBJECTIVE: The aim of this study was to investigate the effect of titanium tetrafluoride solution on L929 fibroblasts by scanning electron microscopy. Titanium tetrafluoride was then compared with sodium fluoride and acidulated phosphate fluoride. STUDY DESIGN: Cells were treated with fluoride solutions for 1 minute either directly, through a filter membrane with a pore size of 0.4-micron, or indirectly, through dentin disks; they were then investigated at an electron microscopic level. RESULTS: Fluoride application on smeared dentin disks showed fewer cytotoxic effects on fibroblasts than application on nonsmeared dentin disks. Acidulated phosphate fluoride and titanium tetrafluoride appeared to be more cytotoxic than sodium fluoride. Because all fluoride solutions used in this study contained the same fluoride concentration, pH was considered to be the main factor causing the higher toxicity. CONCLUSION: Because these solutions demonstrated toxicity in vitro, they must be further evaluated under in vivo conditions to ascertain their clinical safety.

Acidulated Phosphate Fluoride↗

Failure of posterior titanium atlantoaxial cable fixation.

BACKGROUND CONTEXT: The operative treatment of rotatory atlantoaxial instability remains controversial. The use of cable fixation has largely replaced the use of wire for interlaminar fixation. Although cable fixation offers biomechanical advantages over wire fixation, it is still at risk of fatigue failure. The authors were unable to locate any published reports of fatigue failure of titanium cables in the fixation of atlantoaxial instability. PURPOSE: The purpose of this case study is to describe an unusual case of fatigue failure of a titanium cable used to aid in atlantoaxial fusion for the treatment of rotatory atlantoaxial instability. STUDY DESIGN: Case study. METHODS: We reviewed the medical records and X-rays of a patient with rotatory atlantoaxial instability treated with posterior C1-C2 fusion and atlantoaxial fixation with a titanium multistranded cable, who developed fracture of the cable and migration of the cable into the spinal canal. RESULTS: The patient was revised with removal of the broken cable, repair of the pseudarthrosis and fixation with atlantoaxial screws. CONCLUSION: Interlaminar fixation with cables or wires is at risk for failure with potential migration of the wire or cable into the spinal canal. The authors found that failure of the cables or wire can be salvaged with application of transarticular screws.

Adult↗

Titanium-catalyzed enantioselective additions of alkyl groups to aldehydes: mechanistic studies and new concepts in asymmetric catalysis.

The catalytic asymmetric addition of alkyl groups to aldehydes is an important reaction in the enantioselective synthesis of secondary alcohols. This reaction can be catalyzed by zinc- or titanium-based catalysts. While the mechanism of the zinc/amino alcohol catalysts has received significant attention, the titanium-based catalysts have been less studied. This Account summarizes our mechanistic studies with bis(sulfonamide) and BINOL-derived titanium catalysts. It also describes our use of this reaction in the development of new approaches to asymmetric catalysis, including applications of diastereomeric catalysts and optimization of asymmetric catalysts with achiral and meso ligands.

Alcohols↗

Structural characterization of self-assembled polypeptide films on titanium and glass surfaces by atomic force microscopy.

Chemically modified biomaterial surfaces (titanium and glass) covered with polyelectrolyte self-assembled films formed by the alternating adsorption of cationic poly-L-lysine (PLL) and anionic poly-L-glutamic acid (PGA) were structurally characterized by atomic force microscopy. Complementary information concerning the thickness and layer-by-layer growth of the films was provided by optical waveguide light-mode spectroscopy. The frequently used ex situ and the rarely used in situ build-up methods were compared. Important aspects of the industrial applicability of these films, their stability in time, and possible differences in their morphology were investigated. The films revealed a granular pattern, with grain diameters of 270 +/- 87 nm for glass (up to 8 bilayers) and 303 +/- 89 nm for titanium (up to 10 bilayers), independently of the build-up procedure. Both surfaces displayed a rehydration capability, the titanium surface exhibiting a better stability in time. The high roughness values observed at acidic or basic pH are related to the degree of ionization of PGA and PLL.

Adsorption↗

Synthesis and characterization of biocompatible polymer interlayers on titanium implant materials.

A bifunctional copolymer series of (4-vinylbenzyl)phosphonic acid diethylester and N-acryloxysuccinimide was developed as an interlayer with the aim of immobilizing proteins on titanium surfaces. Copolymers with varying compositions were synthesized, and an alternating copolymerization of the two monomers was found. The copolymers form ultrathin films of about 2-8 nm on titanium surfaces in a simple dipping process, as estimated from the attenuation of the titanium X-ray photoelectron spectroscopy (Ti-XPS) signal. The films were characterized by infrared spectroscopy, XPS, and time-of-flight secondary ion mass spectrometry. The results indicate that the immobilization is due to phosphonate groups, and thus the phosphonate content of the copolymers is decisive for the final film thickness. These polymer films were examined for their potential protein binding capacity by using trifluoroethylamine derivatization and subsequent XPS analysis as a reactivity assay.

Biocompatible Materials↗

Selective separation of La3+ and lanthanum organic complexes with nanometer-sized titanium dioxide and their detection by using fluorination-assisted electrothermal vaporization ICP-AES with in-situ matrix removal.

A new method for the determination of free La3+ and La organic complexes in solution using a nanometer-sized titanium dioxide as solid-phase extractant and fluorination-assisted electrothermal vaporization (FETV)-ICP-AES as sensitive detector has been developed. The effect of pH on the adsorption characteristics of La3+ and La complexes of citric acid, 2-hydroxyisobutyric acid (HIBA), and humic acid on nanometer-sized TiO2 was investigated and optimized. On the basis of the difference in volatility between fluoride of analyte (lanthanum) and the fluoride of matrix (titanium), an in-situ removal of the adsorbent matrix (TiO2) from a graphite furnace was realized. Therefore, the free La3+ and adsorbed La complexes on nanometer-sized titanium dioxide could be determined respectively by FETV-ICP-AES without any other chemical pretreatment. The proposed method was applied for the determination of free ion (La3+) and La complexes in synthetic solutions and soil extracts with satisfactory results.

Adsorption↗

Asymmetric synthesis of anti-homopropargylic alcohols from aldehydes and chiral sulfonimidoyl substituted bis(allyl)titanium complexes through generation and elimination of novel chiral alkylidenecarbene (dimethylamino)sulfoxonium ylides.

A new method for the asymmetric synthesis of anti-configured homopropargylic alcohols 1 is described, which features the addition of chiral sulfonimidoyl substituted bis(allyl)titanium complexes 3 to aldehydes, the methylation of sulfonimidoyl substituted homoallylic alcohols 2 at the N-atom, and the elimination of alkenyl (dimethylamino)sulfoxonium salts 7 with LiN(H)tBu. The reaction of isopropyl, cyclohexyl, and methyl substituted allylic titanium complexes 3a-c with benzaldehyde, p-bromobenzaldehyde, p-chlorobenzaldehyde, p-methoxybenzaldehyde, (E)-3-phenylpropenal, and phenylpropynal afforded with high regio- and diastereoselectivities the anti-configured sulfonimidoyl substituted homoallylic alcohols 2a-j, respectively. Only one allylic unit of the titanium complexes 3a-c was transferred in the case of unsaturated aldehydes, and the starting allylic sulfoximines 2a-g were recovered in approximately 50% yield. The methylation of the silyl protected alkenyl sulfoximines 6a-j with Me(3)OBF(4) gave in practically quantitative yields the (dimethylamino)sulfoxonium salts 7a-j, respectively. Salts 7a-e, 7g, 7h, and 7j delivered upon treatment with 2 equiv of LiN(H)tBu the enantio- and diastereomerically pure saturated and unsaturated alkynes 9a-e, 9g, 9h, and 9j, respectively, in high yields. Besides the alkynes the sulfinamide 8 (96% ee) was isolated. Aminosulfoxonium salts 9f and 9i, which carry a CC triple bond, also suffered an elimination under these conditions but did not yield the corresponding diynes. Elimination of salts 7a-e, 7g, 7h, and 7j proceeds most likely through deprotonation at the alpha-position with formation of the novel alkylidenecarbene aminosulfoxonium ylides 19a-e, 19g, 19h, and 19j, respectively. The ylides 19a-e, 19g, 19h, and 19j presumably eliminate sulfinamide 8 with generation of the chiral nonracemic (beta-siloxyalkylidene)carbenes 20a-e, 20g, 20h, and 20j, which suffer a 1,2-H-shift with formation of alkynes 9. Support for the formation of the putative alkylidenecarbenes 20 as intermediates comes from the elimination of the beta-methyl substituted aminosulfoxonium salt 24, which delivered the enantio- and diastereomerically pure 2,3-dihydrofuran derivative 28 upon treatment with LiN(H)tBu in high yield. Here, the putative (beta-siloxyalkylidene)carbene 26 suffers a 1,5-O,Si bond insertion rather than a 1,2-Me shift. Methylation of the alkenyl sulfoximine 6a at the alpha-position with formation of 13 was achieved through deprotonation of the former with formation of the alpha-lithioalkenyl sulfoximine 11a and its treatment MeI. Reaction of the alpha-methylated alkenyl aminosulfoxonium salt 14a with LiNiPr(2) at low temperatures gave the enantio- and diastereomerically pure anti-configured homoallenylic alcohol derivative 15, while reaction of the salt with LiNiPr(2) or LiN(H)tBu at higher temperatures afforded the enantio- and diastereomerically pure nonterminal homopropargylic alcohol derivative 17. Deprotonation of the alkenyl (dimethylamino)sulfoxonium salts 7a and 7b with nBuLi afforded the novel alkylidenecarbene aminosulfoxonium ylides 19a and 19b, respectively, which upon treatment with MeI yielded the methylated aminosulfoxonium salts 14a and 14b, respectively.

Aldehydes↗

Neutral and zwitterionic low-coordinate titanium complexes bearing the terminal phosphinidene functionality. Structural, spectroscopic, theoretical, and catalytic studies addressing the Ti-P multiple bond.

Alpha-hydrogen abstraction and alpha-hydrogen migration reactions yield novel titanium(IV) complexes bearing terminal phosphinidene ligands. Via an alpha-H migration reaction, the phosphinidene ((tBu)nacnac)Ti=P[Trip](CH(2)(tBu) ((tBu)nacnac(-) = [Ar]NC((t)Bu)CHC((t)Bu)N[Ar], Ar = 2,6-(CHMe2)(2C6H3, Trip = 2,4,6-(i)Pr3C6H2) was prepared by the addition of the primary phosphide LiPH[Trip] to the nucleophilic alkylidene triflato complex ((tBu)nacnac)Ti=CH(t)Bu(OTf), while alpha-H abstraction was promoted by the addition of LiPH[Trip] to the dimethyl triflato precursor ((tBu)nacnac)Ti(CH)(2)(OTf) to afford ((tBu)nacnac)Ti=P[Trip](CH3). Treatment of ((tBu)nacnac)Ti=P[Trip](CH3) with B(C6F5)(3) induces methide abstraction concurrent with formation of the first titanium(IV) phosphinidene zwitterion complex ((tBu)nacnac)Ti=P[Trip]{CH3B(C6F5)(3)}. Complex ((tBu)nacnac)Ti=P[Trip]{CH3B(C6F5)(3)} [2 + 2] cycloadds readily PhCCPh to afford the phosphametallacyclobutene [((tBu)nacnac)Ti(P[Trip]PhCCPh)][CH3B(C6F5)(3)]. These titanium(IV) phosphinidene complexes possess the shortest Ti=P bonds reported, have linear phosphinidene groups, and reveal significantly upfielded solution 31P NMR spectroscopic resonances for the phosphinidene phosphorus. Solid state 31P NMR spectroscopic data also corroborate with all three complexes possessing considerably shielded chemical shifts for the linear and terminal phosphinidene functionality. In addition, high-level DFT studies on the phosphinidenes suggest the terminal phosphinidene linkage to be stabilized via a pseudo Ti[triple bond]P bond. Linearity about the Ti-P-C(ipso) linkage is highly dependent on the sterically encumbering substituents protecting the phosphinidene. Complex ((tBu)nacnac)Ti=P[Trip]{CH3B(C6F5))(3)} can catalyze the hydrophosphination of PhCCPh with H(2)PPh to produce the secondary vinylphosphine HP[Ph]PhC=CHPh. In addition, we demonstrate that this zwitterion is a powerful phospha-Staudinger reagent and can therefore act as a carboamination precatalyst of diphenylacetylene with aldimines.

Acetylene↗

The effect of titanium dioxide alumina beads on the photocatalytic degradation of picloram in water.

Photocatalytic degradation of pesticides with titanium dioxide (TiO(2)) and other catalysts has shown promise as a potential water remediation method. Titanium-based powders have been used in photocatalytic degradation studies but have limitations. The objective of this study was to determine picloram degradation in water using various UV light sources and low-pressure metal organic chemical vapor deposition titanium dioxide alumina beads (TDABs) as a catalyst. A triple-annular, flow-through photoreactor was used as a degradation chamber. A picloram test solution of 50 microg/mL was introduced to the photoreactor inlet and recycled for 10 h at a flow rate of 50 mL/min. Three ultraviolet light sources were compared for their photocatalytic capacity (UV-A, UV-B, and UV-C) both with and without TDABs. TDABs were added to the photoreactor at 1.8 g/cm(3). Dark treatments with and without TDABs were included to quantify hydrolysis or adsorption. A 500-microL aliquot was taken from the test solution 14 times during the 10-h recycling period. Sampling times ranged from 0 to 600 min (10 h). These aliquots were placed in a vial and analyzed by high performance liquid chromatography equipped with a photodiode array detector. Picloram was not significantly hydrolyzed or adsorbed to TDABs during the experiment. The picloram degradation rate with UV-A and TDABs (t(1/2) = 119.5 min) was greater than the degradation rate of UV-A alone (t(1/2)=2288 min). Picloram degradation was not enhanced by the presence of TDABs with either UV-B or UV-C. This may be attributed to inadequate TDAB densities and/or poor light penetration in the photoreactor. Rapid picloram degradation occurred with both UV-B and UV-C, regardless of the presence of TDABs with mean half-lives ranging from 7 to 18 min. These rates were 8 to 16 times faster than picloram degradation using UV-A with TDABs. TDABs' greatest photocatalytic effect was with the lowest energy light source (UV-A). However, picloram degradation was not enhanced when TDABs were combined with more powerful, shorter wavelength light.

Aluminum Oxide↗

Titanium-mediated [2 + 2 + 2] coupling of diynes with homoallylic alcohols.

[reaction: see text] In connection with the known diyne-ene [2 + 2 + 2] cycloaddition reactions mediated by titanium aryloxides, the ability of titanium alkoxides to promote coupling of a titanacyclopentadiene with an alkene has been assessed for the isomerization-free preparation of 1,3-cyclohexadienes. The successful cycloaddition by titanium alkoxides is predicated on the use of homoallylic alcohols as the olefin component. With secondary homoallylic alcohols, high 1,3-diastereoselectivity is observed, which lends itself to enantioselective preparation of functionalized 1,3-cyclohexadienes.

Alcohols↗

Gradient surface porosity in titanium dental implants: relation between processing parameters and microstructure.

To be successful, an implant should be biocompatible, strong and contain surface pores to promote osseointegration. A one-step microwave sintering procedure of titanium powders was attempted in this work. The idea was to take advantage of the peculiar way microwave couple with metallic powders, i.e. generating heat in the interior of the sample and dissipating it away through the surface. This non-conventional heating of titanium powder produced a dense core with surface porosity. The dense core provides the strength while the surface pores promote bone growth. The experiments were carried out in a semi-industrial grade microwave cavity using a alpha-SiC susceptor. Power levels of 1-1.5 kW, and soaking periods of approximately 30 min were used. Microstructural characterization was carried out by a scanning electron microscope. The sintered titanium had gradient porosity on the surface with a thickness of about 100-200 microm depending on the microwave power. The pores were interconnected with size ranging from 30 to 100 microm. This kind of microstructure is favorable for cell growth. Tensile strength values as high as 400 MPa were obtained for these samples.

Dental Implants↗

Evaluation of different methods to clean titanium abutments. A scanning electron microscopic study.

The cleaning effectiveness of different treatment methods for titanium abutments was evaluated using scanning electron microscopy (SEM). In the mandible of 4 beagle dogs, 25 titanium abutments were installed (modum Brånemark). After 16 weeks of plaque accumulation, mineralized deposits had formed on 23 abutments. Each of these abutments was subjected to one of the following treatment methods: scaling with (1) metal, (2) plastic, or (3) ultrasonic instruments; (4) air-polishing, (5) weekly rubber cup polishing or (6) daily brushing with a conventional toothbrush. Fourteen abutments were removed immediately after treatment. On 9 abutments, the scaling procedures and air-polishing were repeated after another 16 weeks of plaque accumulation. The abutments were prepared for SEM, and each of them was viewed and photographed at 3 different magnifications. The photomicrographs were evaluated by 3 examiners who, guided by reference pictures, gave each abutment a "cleanliness" score, ranking from 0 to 5. Regular rubber cup polishing and regular brushing resulted in the highest surface cleanliness, while the air-polishing procedure showed the lowest cleanliness score. None of the 3 scaling methods created a cleanliness score better than 3. The 3 scaling methods were considered equal in their cleaning effectiveness. No differences could be observed between surfaces treated 1 x or 2 x. Taken the present findings and those of other studies concerning the effects of scaling on the surface roughness and biocompatibility into consideration, it was concluded that plastic scalers may be the instruments of choice for debridement of titanium implant surfaces.

Animals↗