Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulsatile Flow”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

Concentration polarization of low density lipoproteins (LDL) in the arterial system.

The atherogenic lipid concentration at the luminal surface of a blood vessel may vary according to its location in the arterial tree because of regional differences in wall shear rate, blood pressure, and vascular permeability. We therefore hypothesized that these local variations in the luminal surface lipid concentration may contribute to the localization of atherosclerosis. To verify this hypothesis, the transport of low-density lipoproteins from flowing blood to the arterial wall was studied numerically under both steady-state and pulsatile flow conditions. Numerical analysis predicted that "concentration polarization" of LDL may occur in the arterial system under these conditions. In contrast to steady-state flow conditions, the luminal surface LDL concentration varied with time in a cardiac cycle. However, its time-average value was slightly higher than the corresponding value under steady-state flow conditions. The time-average value of the luminal surface LDL concentration was 5 to 14% greater than the bulk concentration in a straight segment of an artery. The luminal surface LDL concentration at the arterial wall was flow-dependent, varying linearly with the filtration rate through the vessel wall and inversely with wall shear rate. This may therefore have some significant implications for the pathogenesis and localization of vascular disorders.

Animals↗

Advantages of continuous measurement of cardiac output 24 h a day.

To test the hypothesis that continuous measurement of cardiac output 24 h a day would provide a better day-by-day reproducibility of the daily average cardiac output than acute measurements, we developed a computer-assisted method to monitor cardiac output continuously using an electromagnetic flow transducer. Because the diastolic aortic flow, which is used as a zero-flow reference, can drift significantly with electromagnetic flow probes, automatic tracking of the diastolic flow baseline was considered essential for long-term measurements. To accomplish this, the analog pulsatile flow signal was digitally converted and processed by an IBM PC to correct for signal drift on a beat-per-beat basis. Using this computerized system in 19 chronically instrumented dogs, we compared the values of cardiac output during 5 consecutive control days, measured either for 20 h each day (allowed 4 h for special care) or for 30 min in the morning when the trained dogs were required to lie quietly in their cages. The results show that the coefficient of variation of the five daily averages in cardiac output for each individual dog was three times smaller when cardiac output was measured 20 h each day (2.9 +/- 0.3 vs. 9.7 +/- 1.0%). Whole-day coefficients of variation were also smaller for mean arterial pressure, heart rate, stroke volume, and total peripheral resistance. Because of this greater day-by-day reproducibility, continuous monitoring of cardiac output is likely to be more sensitive to small changes in cardiac output induced by experimental protocols.

Animals↗

Studies in vitro of the relationship between ultrasound and laser Doppler velocimetry and applicability to the simplified Bernoulli relationship.

While there has been wide general acceptance of Doppler methods that use the simplified Bernoulii relationship to estimate pressure gradients across stenotic orifices, there is still ongoing controversy related to potential sources of error in the method. In this study we tested accuracy o ultrasound Doppler measurements of flow velocity when compared with the gold standard of laser light Doppler anemometry in a pulsatile flow model of pulmonic stenosis in vitro. We tested two commercially available Doppler systems and examined steered and nonsteered, parallel and off-axis and angle-corrected velocity determinations using continuous-wave and high-pulse repetition frequency (HPRF) methods. We also examined the potential range of error in the simplified Bernoulli method. One hundred and twenty individual flow states were examined with three stenotic valve orifices (3.0, 1.0, and 0.5 cm2 flow area) to measure velocities up to 620 cn/sec. A very high correlation coefficient was obtained for the comparison of laser Doppler anemometric and ultrasound velocity recordings by the nonsteered continuous-wave technique (r= .99, SEE = 17.9 cn/sec), but there was a tendency for underestimation of higher velocities when the transducer was positioned at 30 degrees and the ultrasound beam was steered so as to be parallel to the visualized flow jet (r = .98, SEE = 29.6 cn/sec). The HPRF ultrasound Doppler technique was also highly accurate in this optimized setting for measuring velocities (r = .99, SEE = 17 cm/sec), but also slightly underestimated the highest velocities. Our results also verified the accuracy of the simplified Bernoulli equation for converting instantaneous velocity measurements to estimated peak instantaneous gradient (r = .97, SEE = 8.4 mm Hg).

Blood Flow Velocity↗

Cerebrospinal fluid pulse waveform as an indicator of cerebral autoregulation.

Systems analysis of the systemic arterial (SAPW), cerebrospinal fluid (CSFPW), and sagittal sinus (SSPW) pulse waves was carried out in 13 dogs during hypercapnia (5% CO2), intracranial normotension (inhalation of 100% O2), and intracranial hypertension (inhalation of 100% O2 plus an intraventricular infusion). Power amplitude and phase spectra were determined for each wave, and the power amplitude and phase transfer functions calculated between the cerebrospinal fluid (CSF) pressure and systemic arterial pressures, and between the sagittal sinus pressure and CSF pressure. The study indicates that the CSFPW and SSPW were virtually identical when impedance between the cerebral veins and sagittal sinus was minimal, which argues that the CSF pulse was derived from the cerebral venous bed. During inhalation of 100% O2, transmission of the SAPW across the precapillary resistance vessels into the cerebral venous pulse (as represented by the CSFPW) was nonlinear, while transmission across the lateral lacunae into the sagittal sinus was linear. During intracranial hypertension, wave transmission across the precapillary resistance vessels was linear, and across the lateral lacunae was nonlinear. During hypercapnia, wave transmission across the precapillary resistance vessels and the lateral lacunae was linear. When the wave transmission was nonlinear, there was also suppression in transmission of the lower harmonics, particularly the fundamental frequency, and a more positive phase transfer function, suggesting an inertial effect or decrease in acceleration of the pulse. Conversion from a nonlinear to linear transmission across the precapillary resistance vessels is evidence of loss of vasomotor tone, and is accompanied by rounding of the CSFPW. A vascular model which encompasses the above data and is based on flow in collapsible tubes and changes in vasomotor tone is posited to explain control of pulsatile flow and pulse waveform changes in the cerebrovascular bed. The model helps to clarify the strong interrelationship between intracranial pressure, cerebral blood flow, and cerebral autoregulation.

Animals↗

[Artificial hearts--toward future technologies].

What are the most essential technologies for developing the implantable artificial heart in future? The first is the development of autonomic and dispersed micro actuators for acting as sarcomeres of the heart muscle. An electric motor driven artificial heart transmitted the power with belts had been developed as a preliminary mechanism. A micro actuation using noise energy has been developed for simulating the structure and the function of striate-muscle sarcomeres. The chemical energy conversion mechanism must be applied instead of the conventional electro-mechanical mechanisms, when we implant the total artificial heart permanently. As a implantable assisted artificial heart using tentatively, we have developed an axial flow pump system. The pump system acts as a systemic and a pulmonary pump produced pulsatile flow switching an axial pump output. The second is the search of biocompatible materials, which do not only mean blood compatibility but also tissue compatibility. The great masses in chest cavity have inevitably occurred infection. The autonomic and dispersed control system is the third item. We have developed a jellyfish valve with low fluid dynamical resistances for improving the pump dynamic characteristics.

Heart, Artificial↗

Pulsatile ocular blood flow in eyes with untreated choroidal melanoma.

PURPOSE: To investigate the effect of choroidal melanoma on pulsatile ocular blood flow (POBF). METHODS: Seventeen patients (10 men and 7 women) with unilateral untreated choroidal melanoma and 22 controls matched for age and sex were studied. Intraocular pressure (IOP), pulse amplitude (PA) and POBF were measured using the OBF Tonograph. In each patient, mean inter-ocular differences were analysed using the paired t-test. The correlation coefficient between tumour thickness and POBF was calculated. To assess the variation of this parameter, the coefficient of variation for three repeated readings was determined for healthy and affected eyes. RESULTS: In the control group, there was no significant difference between eyes in any parameter. In patients with melanoma, there was no significant difference in IOP and PA between affected and unaffected eyes. Mean POBF was significantly higher in affected eyes (1040 microliters min-1) than unaffected eyes (876 microliters min-1) (p = 0.003). There was no correlation between tumour thickness and absolute POBF (r = -0.24) or between tumour thickness and inter-ocular difference in POBF between affected and unaffected eyes (r = -0.17). Mean coefficient of variation of three repeated readings of POBF was 7.76% in healthy eyes and 8.97% in affected eyes. CONCLUSIONS: These findings suggest a high tumour blood flow or a global increase in choroidal blood flow in the presence of melanoma. POBF measurement may be useful in the clinical assessment of eyes with choroidal melanoma.

Aged↗

Comparison of pulsatile and non-pulsatile cardiopulmonary bypass in patients with chronic obstructive pulmonary disease.

BACKGROUND: Patients with chronic obstructive pulmonary disease have an increased risk of mortality and morbidity after open-heart surgery. This is mostly due to a dysfunction of the pulmonary system during and after non-pulsatile cardiopulmonary bypass. The purpose of this study was to compare the pulsatile and non-pulsatile blood flows during cardiopulmonary bypass in patients with chronic obstructive pulmonary disease. MATERIAL/METHODS: This is a prospective study. Ten patients with chronic obstructive pulmonary disease had open-heart surgery with pulsatile flow, and another 9 patients with non-pulsatile flow. We compared clinical, hemodynamic, biochemical and hematological parameters and arterial and venous blood gases before initiating cardiopulmonary bypass, at aortic cross-clamping and de-clamping, and 1 and 24 hours postoperative. RESULTS: In the pulsatile flow group, systemic vascular resistance at the time of aortic cross clamping (p=0.041), pulmonary vascular resistance 1 hour postoperative (p=0.05), and the percentage of neutrophils 1 hour postoperative (p=0.034) were significantly lower than those of the non-pulsatile group. Though white blood cell count was significantly high in the pulsatile group 1 hour postoperative, absolute neutrophil count was significantly low (p=0.034). The postoperative mechanical ventilation period was significantly shorter in the pulsatile flow group (p=0.016). CONCLUSIONS: Pulsatile blood flow during cardiopulmonary bypass has a favorable influence on patients with chronic obstructive pulmonary disease, who have high risk in open-heart surgery.

Blood Gas Analysis↗

Pulsatile ocular blood flow: changes associated with scleral buckling procedures.

PURPOSE: To determine the changes in the pulse amplitude (PA) and the pulsatile ocular blood flow (POBF) after scleral buckling (SB). METHODS: Retrospectively, we studied 24 patients (average age, 52 years) who had undergone SB to repair a retinal detachment in one eye. The patients were divided into two groups: those in whom SB had been performed less than 6 months earlier (n = 10), and those in whom the procedure had been performed more than 6 months previously (n = 14). In each group, the PA and the POBF were determined with a computerized tonometry system, and the values in the SB eyes were compared with those in the control fellow eyes. RESULTS: Within 6 months postoperatively, the mean PA in the SB eyes (0.66 +/- 0.30 mmHg) was significantly lower than that in the control eyes (1.43 +/- 0.34 mmHg; P < 0.05). The mean POBF in the SB eyes (349.5 +/- 154.1 microl/min) was also significantly lower than that in the control eyes (631.0 +/- 226.6 microl/min; P < 0.05). After more than 6 months postoperatively, there were no significant differences in the PA or the POBF between the SB eyes (1.08 +/- 0.49 mmHg and 612.4 +/- 341.2 microl/min, respectively) and the control eyes (1.50 +/- 0.51 mmHg and 589.5 +/- 278.4 microl/min, respectively). CONCLUSIONS: These results indicate that the choroidal blood flow decreases after SB but returns to normal levels after 6 months.

Blood Flow Velocity↗

Estimation of aortic and pulmonary blood flow in a paediatric population using Doppler ultrasound: an in-vitro study.

The noninvasive measurement of blood flow using ultrasound has been attempted by numerous workers. In order to evaluate the technique of duplex scanning applied to the problem of noninvasive assessment of aortic and pulmonary blood flow in a paediatric population with ventricular septal defect, we attempted an in-vitro simulation of these flow conditions. The factors which have been considered in the design of the apparatus include the availability of a range of tube diameters, an aortic-"like" waveform, laminar flow, variable downstream peripheral resistance, a compliance factor and viscosity of the flow medium. The ultrasound probe beam characteristics, sample volume size and shape were also determined. From the results of the beam plots it was apparent that the region of sensitivity of the CW Doppler probes were inappropriate for the measurement of blood flow in neonates. In order to simulate physiological parameters in a paediatric population as closely as possible, five tubes of diameters ranging from 9-18 mm were used, in each tube a range of flow values from 0.8 L min-1 to 5 L min-1 were measured. The flow values were measured by both "bucket and stopwatch" and duplex scanner for both steady and pulsatile flow conditions. The results are presented as correlations between the direct and noninvasive pulsed Doppler assessment of flow measurement and are in the range 0.92-0.99 significant at p less than .001. A discussion of the reliability of flow measurements made using a conventional duplex scanner is given.

Aorta↗

Non-invasive measurement of pulmonary arterial pressure: I. A haemodynamic modelling approach.

In order to monitor pulmonary arterial pressure (P) by any non-invasive imaging technique, a haemodynamic model of blood flow kinetics and wall mechanics has been developed. It is a one-dimensional model of pulsatile flow in an elastic pulmonary arterial trunk, assuming that blood is an incompressible fluid and viscous effects are negligible. The equations are P(t)-Pd = rho c2lnS(t)/Sd-1/2pw-2(t) Pd = (Sd/Ss)1/2Pp where, at any time of the ejection phase of systole, P(t), S(t) and w(t) are the pulmonary arterial pressure, cross-sectional area of the pulmonary artery and blood velocity averaged on the cross section S, respectively, PP is the pulse pressure, the difference between the peak systolic pressure and the diastolic pressure Pd; rho is blood density, c pulse wave velocity, and Ss and Sd are maximum (systolic) and minimum (diastolic) values of the cross-sectional area S. Using these equations, P(t) can be calculated if the three parameters, i.e. c, S(t) and w(t) are measured. So far, it has been impossible to measure the pulse wave velocity c non-invasively. We have investigated the calculation of c from S(t) and w(t) using the equation of continuity in the absence and presence of reflected pressure waves. The hypotheses of the haemodynamic model are discussed.

Blood Flow Velocity↗

Color Doppler sonography of benign and malignant ovarian masses.

The use of transvaginal and transabdominal color Doppler sonography for the assessment of ovarian tumor vascularity was investigated in 62 cases of surgically excised and histologically examined ovarian masses. The modality was used to differentiate tumor neovascularity from normal arterioles (which contain smooth muscle in their media) on the basis of differences in the pulsatility observed in Doppler waveforms. Of the 25 malignant tumors in the series, 20 had low-impedance flow (pulsatility index of less than 1.0), and none had the diastolic notch seen in vessels in normal tissue. Three benign lesions, including two dermoid cysts and one tubo-ovarian abscess, also had low-impedance flow. The negative predictive value of color Doppler sonography was 98%, whereas the positive predictive value was 83%. Color Doppler sonography seems to be accurate for excluding malignancy, but some misdiagnosis may occur in cases of inflammatory and metabolically active benign masses.

Female↗

In vitro evaluation of prosthetic heart valves: towards comparable testing.

The Laboratory of Biomedical Engineering (of the National Health Institute, technical body of the Italian Health Service) performs in vitro testing of prosthetic heart valves for mechanical characteristics of materials, fatigue life, and fluidodynamic performance. Testing of materials is directed towards the physicomechanical characterization of the structural components of the valves, e.g. elasticity and resistance to stress of biological tissues and stents. Long-term fatigue life tests are conducted by means of systems which make valves beat at more than 1200 cycles/min. These tests are preceded and followed by geometrical characterization and by steady flow testing in order to obtain information about stenosis and leakage. Special attention is devoted to pulsatile flow testing which is performed on two pulse duplicators: the Dynatek system and the system developed by the University of Sheffield. The same valve was tested with these systems according to their different possible set-ups within the general requirements established by ISO-DIS 5840. This paper presents significant measurements, taking into account their dependence on the systems adopted. Results show (a) the difficulties in comparing test results because of different operating conditions, and (b) the systems' sensitivity with regards to some parameters which affect measurements under comparable set-up conditions (FDA Interlaboratory Comparison Testing Protocol).

Biomechanical Phenomena↗

[Accuracy of various Doppler technics in recording blood flow velocity. Studies in vitro].

Conventional and color-coded Doppler techniques were studied as to their accuracy in displaying flow and velocity using an in vitro model and a Laser-Doppler-anemometer. Furthermore, the estimation of pressure gradients as determined by Doppler ultrasound was compared to measurements by manometers under a variety of hemodynamic conditions. Pulsed and continuous wave Doppler had good reproducibility. There was an excellent correlation for measurements of flow velocity as determined by Doppler ultrasound and by Laser-Doppler anemometer (r = 0.98, SEE = 3 cm/s). The well-known underestimation of flow velocity due to an increasing angle of incidence (greater than 25 degrees) was confirmed in vitro. However this error was smaller than the actual overestimation resulting from angle correction for the apparent cosine. Doppler gradients correlated strongly with manometer gradients for orifice areas 12-80 mm2 and flow volumes 0.9-12.8 l/min (r = 0.98, SEE = 7 mm Hg) using continuous as well as pulsatile flow. Some overestimation of the Doppler gradient occurred with increasing flow rates (r = 0.66). Color-Doppler has poor spatial resolution. Display of velocities was therefore assessed using a qualitative score (0-5), the variability of which was 13 +/- 30% of the initial value. Display of faintest quality (score 1) was useless for clinical assessment in color-Doppler technique, but allowed quantitative measurement of velocity in conventional Doppler. Reduction of flow velocities limited display in color-Doppler (5-20 cm/s) but not in pulsed-Doppler technique. Thus, conventional Doppler has better sensitivity and accuracy of displaying flow when compared to color-Doppler, particularly in conditions of poor imaging. As reproducibility and accuracy of velocity determination are excellent, this technique should be used in all diagnostic procedures involving ultrasound. The Doppler gradient as derived from the modified Bernoulli equation provides accurate results in vitro which may also be concluded for use in the clinical situation.

Blood Flow Velocity↗

Pulsatile cardiopulmonary bypass. A review.

Pulsatile perfusion during cardiopulmonary bypass has recently been introduced into clinical practice. In this paper the experimental basis for the superiority of pulsatile perfusion is reviewed. In particular, the haemodynamic and metabolic superiority of pulsatile perfusion is outlined. In addition, more practical aspects of pulsatile pump systems are discussed. The mechanism of pulsatile flow generation and the type of arterial wave form produced, are considered in relation to the pulsatile systems presently available for clinical use. Studies on haemolysis during pulsatile perfusion are also discussed and the overall suitability of current systems for routine clinical use is assessed. The author concludes that presently available pulsatile pump systems may confidently be incorporated into routine open-heart surgical practice without compromising the reliability or the safety of the perfusion credit.

Cardiopulmonary Bypass↗

In vitro assessment of prosthetic valve function in mitral valve replacement with chordal preservation techniques.

BACKGROUND AND AIM OF THE STUDY: The importance of chordal preservation techniques in maintaining improved left ventricular function after mitral valve replacement has been well documented clinically. Currently, the choice of prosthetic valve used in chordal preservation is dependent upon the surgeon's preference. However, the transvalvular flow characteristics of common, clinically used prosthetic valves may be influenced by the mitral subvalvular apparatus, and may result in degraded valve function. The goal of this study was to perform an in vitro evaluation of the influence of chordal preservation on the transvalvular and left ventricular flow patterns of common valve prostheses. METHODS: Tissue and mechanical valves have been evaluated under physiologic pulsatile flow with anterior and/or posterior chordal preservation. Flow patterns were assessed by 2-D planar flow visualization, pulsed wave Doppler velocity measurements, 2-D echocardiography, and selected color Doppler flow mapping. Based on changes in transvalvular and left ventricular flow patterns, favorable prosthetic valve/chordal preservation combinations were identified. Additionally, valve orientation was varied to determine optimal orientation. RESULTS: Baseline results without chordal preservation indicate that the anti-anatomic orientation is preferred for the bileaflet valve design while the tilting disc valve should be oriented with the major axis toward the posterior (free) wall of the ventricle, corroborating published conclusions by other investigators. Some form of flow restriction is observed in all test cases with chordal preservation due to the presence of the subvalvular tissue. In general, bioprostheses showed less flow restriction then the mechanical valves, particularly with lateral flow expansion. This flow restriction may influence pressure recovery downstream of the mechanical valves tested. Increased flow constriction is observed with anterior and posterior chordal preservation. CONCLUSIONS: This study favors the use of the St. Jude Medical bileaflet valve orientated in the anti-anatomic position, or the Carpentier-Edwards pericardial valve with chordal preservation.

Bioprosthesis↗

Value and limitations of proximal jet dimensions for the quantitation of valvular regurgitation: an in vitro study using Doppler flow imaging.

To evaluate usefulness and limitations of proximal jet dimensions for the quantitation of valvular regurgitation, fluid jets were created in a pulsatile flow model, and proximal jet width and cross-sectional area were measured by means of color Doppler flow imaging. When circular orifices with diameters from 1 to 6 mm were studied, jet width and cross-sectional jet area measured as close as possible to the orifice were directly related to the orifice diameter (r = 0.97; standard error of the estimate, 0.4 mm; y = 0.5 + 0.97x) and the orifice area (r = 0.97; standard error of the estimate, 5.7 mm2; y = 0.22 + 2.47x), respectively. No significant dependence on flow rate or pressure gradient was found for these measurements. Jet width was measured with color M-mode Doppler by use of the smallest sample volume size (1 mm) and was slightly greater than the orifice diameter (4.2 +/- 1.7 mm versus 3.8 +/- 1.7 mm). However, cross-sectional areas were approximately fourfold the orifice areas, on average (52.5 +/- 24.6 mm2 versus 12.3 +/- 9.7 mm2), with a range of twelvefold (smallest orifice) to threefold (largest orifice). When the sample volume size was reduced from 2.4 to 1.0 mm, color areas decreased by 25.6 +/- 6.0%. Slit-shaped orifices were studied with two different orientations of the slit-parallel and perpendicular to the ultrasound beam: Color M-mode measurements were again slightly greater than length and width of the slit, but cross-sectional areas were substantially larger than the orifice areas and increased between 44% and 115% when changing the orientation of the slit from perpendicular to parallel. This, again, reflected problems with lateral resolution. When cross-sectional areas were measured at increasing distances from the orifice, the cross-sectional jet area increased significantly within a few millimeters. This increase was greater with higher gradients and smaller orifice sizes. In case of a small orifice (2 mm) and a high gradient (130 to 160 mm Hg), increase in area was as great as 122% within a distance of only 5 mm. Thus, proximal jet width and cross-sectional area were directly related to the orifice size, which could be a valuable parameter for the evaluation of valvular regurgitation. Measurements of jet width by color M-mode seemed to be most accurate but are limited by the fact that in vivo valvular defects may be irregular rather than of circular shape.(ABSTRACT TRUNCATED AT 400 WORDS)

Aortic Valve Insufficiency↗

Correlation of the cardiogenic air flow in the respiratory airway (i.e. the pneumocardiogram) with left ventricular stroke volume in dogs.

The pneumocardiogram (PNCG) is a record of the pulsatile flow of air in the trachea coincident with each heart beat. In 5 anesthetized mongrel dogs, the cardiogenic air flow through an endotracheal tube was measured with a research pneumotachograph. The correlation between the pneumocardiographic volume of air, obtained by integrating the PNCG over the period of ventricular ejection, and stroke volume (SV), measured by the saline-dilution method, was determined for a physiologic range of SV. Although the pneumocardiographic volume tracked measured SV, the former was always less. The range of correlation coefficients was 0.60 to 0.91. The results suggest that the PNCG may be suitable for continuous tracking of changes in SV on a noninvasive, beat-by-beat basis. The technique is ideally applicable to intubated human subjects, particularly those undergoing closed-chest surgical procedures.

Animals↗

The effect of myopic axial elongation and posture on the pulsatile ocular blood flow in young normal subjects.

PURPOSE: This study investigated the effect of myopic axial elongation on pulsatile ocular blood flow (POBF) in young normal subjects. A regression equation was derived to quantify the effect. The effect of posture in POBF for eyes with different axial lengths was studied to determine if axial myopia, with different ocular volumes, would result in a change in POBF with various postures. METHODS: Seventy-nine normal subjects (38 males and 41 females) with different refractive errors were recruited. The mean age of the subjects was 22 years, and only the right eye was used for analysis. The axial length (AL) was measured, followed by Perkins intraocular pressure (IOP) and POBF with an OBF tonometer (OBF Labs [UK] Ltd) in a sitting posture. An "erected arm" blood pressure (BP) was measured with an automatic sphygmomanometer for the calculation of ocular perfusion pressure (OPP), using the formula: mean BP IOP, where the mean BP was calculated as one third of the systolic blood pressure plus two thirds of the diastolic blood pressure. The measurements of IOP, POBF, and BP were repeated in a supine posture. RESULTS: The POBF was negatively correlated with AL (r = -0.57, p < 0.01). The regression line was in the form of POBF (microl/min) = -78.5 x AL (mm) + 2655.7. There was a significant reduction (17%) in POBF in a supine posture (p < 0.01). The reduction was not significantly correlated with AL. The pulse amplitude also demonstrated a 10% reduction from postural variation (p < 0.01). The OPP increased significantly (33%) in the supine posture (p < 0.01). CONCLUSIONS: The POBF was significantly influenced by AL. Therefore, AL should be measured in determining the POBF, especially in young myopic subjects. The amount of postural variation in POBF was similar to previous studies with young subjects and was not affected by AL.

Adult↗