Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

Amplification of xenon NMR and MRI by remote detection.

A technique is proposed in which an NMR spectrum or MRI is encoded and stored as spin polarization and is then moved to a different physical location to be detected. Remote detection allows the separate optimization of the encoding and detection steps, permitting the independent choice of experimental conditions and excitation and detection methodologies. In the initial experimental demonstration of this technique, we show that taking dilute 129Xe from a porous sample placed inside a large encoding coil and concentrating it into a smaller detection coil can amplify NMR signal. In general, the study of NMR active molecules at low concentration that have low physical filling factor is facilitated by remote detection. In the second experimental demonstration, MRI information encoded in a very low-field magnet (4-7 mT) is transferred to a high-field magnet (4.2 T) to be detected under optimized conditions. Furthermore, remote detection allows the utilization of ultrasensitive optical or superconducting quantum interference device detection techniques, which broadens the horizon of NMR experimentation.

Lasers↗

Preliminary study of potential for rapid prototype and surface scanned radiotherapy facemask production technique.

Preliminary investigations into the potential of an elegant technique to create a rudimentary facemask for patient immobilization during radiotherapy treatment are presented. This method combines modern technology to cause the patientfar less discomfort compared with current plaster of Paris (POP) face mould procedures. Near instantaneous patient face scanning is accomplished with charge-coupled devices for imaging in an optical surface scanning system. The surface generated data is input to a rapid prototype (RP) system that creates a life-size model of the patient's face topology. As proof of principle a basic prototype facemask was successfully constructed using this technique and some qualitative comparison measurements for position and surface dose were made. These initial results confirm the validity of this technique and justify the need for further quantitative studies to fully investigate the potential of RP facemasks over POP based methods for mask production.

Acrylic Resins↗

Telescopic eyepieces in indirect ophthalmoscopy.

A new attachment that can be used with optimized ophthalmoscopes is described. Readily removable and interchangeable eyepieces containing small, lightweight Galilean telescopes approximately double the magnification. The influence of this device on some of the optical properties of binocular indirect ophthalmoscopy including magnification, field of view, brightness of the fundus image, and stereopsis, are reviewed briefly.

Humans↗

Lattice Boltzmann algorithm for three-dimensional liquid-crystal hydrodynamics.

We describe a lattice Boltzmann algorithm to simulate liquid-crystal hydrodynamics in three dimensions. The equations of motion are written in terms of a tensor order parameter. This allows both the isotropic and the nematic phases to be considered. Backflow effects and the hydrodynamics of topological defects are naturally included in the simulations, as are viscoelastic effects such as shear-thinning and shear-banding. We describe the implementation of velocity boundary conditions and show that the algorithm can be used to describe optical bounce in twisted nematic devices and secondary flow in sheared nematics with an imposed twist.

Journal Article↗

Nonlinear optical effects in a two-dimensional photonic crystal containing one-dimensional Kerr defects.

The nonlinear optical effects induced by a one-dimensional (1D) line defect, made of Kerr material, in a 2D photonic crystal are studied. Comprehensive ab initio numerical simulations based on the finite-difference time-domain method show efficient third-harmonic generation in a photonic crystal waveguide consisting of the 1D defect line. The relationship between the third harmonic generation process and the nonlinear modal properties of the waveguide is discussed. We investigate optical limiting in such a device, that is, control of the transmitted power as a function of the Kerr-induced variation of the refractive index. Power dependent spectral changes in such a device and its use as a frequency selector are also examined.

Journal Article↗

3,3,4,4,5,5-Hexafluoro-1,2-bis(5-hydroxymethyl-2-methyl-3-thienyl)cyclopent-1-ene.

The title compound, C(17)H(14)F(6)O(2)S(2), a photochromic diarylethene, is one of the most promising materials for optical memories and other optoelectronic devices. The hexafluorocyclopentene group and the two thiophene rings are all planar, and the dihedral angles between the cyclopentene ring and the adjacent thiophene rings are 46.4 (1) and 49.5 (1) degrees.

Journal Article↗

1,2-Bis[5-(1,3-dioxolan-2-yl)-2-ethyl-3-thienyl]-3,3,4,4,5,5-hexafluorocyclopent-1-ene, a photochromic dithienylethene.

The title compound, C23H22F6O4S2, a photochromic dithienylethene, is a promising material for optical storage and other optoelectrical devices. The molecule adopts a photoactive antiparallel conformation in the crystalline state. The distance between the two reactive C atoms which are involved in potential ring closure is 3.829 (4) A. The dihedral angles between the central cyclopentene ring and the adjacent thiophene rings are 55.38 (7) and 54.81 (9) degrees. The colourless crystals turn magenta when exposed to UV radiation and the process is reversible.

Journal Article↗

1-(2-Methyl-5-phenyl-3-thienyl)-2-(3-methyl-5-phenyl-2-thienyl)-3,3,4,4,5,5-hexafluorocyclopent-1-ene: a novel photochromic hybrid diarylethene.

The title compound, C27H18F6S2, a novel photochromic hybrid diarylethene derivative containing 2- and 3-thienyl substituents, is one of the most promising photochromic candidates with shorter wavelength for optical storage and other optoelectronic devices. In the crystal structure, the molecule adopts a photoactive antiparallel conformation. The distance between the two reactive C atoms, i.e. the ring C atoms to which the methyl groups are attached, is 3.430 (4) A. The dihedral angles between the thienyl and adjacent phenyl rings are 26.8 (2) and 33.98 (9) degrees.

Journal Article↗

Recent developments in X-ray imaging with micrometer spatial resolution.

X-ray detectors for imaging with a spatial resolution in the micrometer and submicrometer range have been developed at synchrotron radiation sources since 1996. The detectors consist of a scintillator, a light microscopy optic and a charge-coupled device (CCD). The scintillator converts part of the X-ray stopped by a material into a visible-light image which is projected onto the CCD by the light optics. A resolution of 0.5 microm FWHM has been achieved using a 1 microm-thick europium-doped Lu3Al5O12 film. The detective quantum efficiency of the detector is mainly limited by the low absorption of X-rays in the thin layer of the scintillator. To increase the absorption, and therefore reduce the exposure time, new scintillators (Lu2O3:Eu3+, Gd2O3:Eu3+, Lu2SiO5:Ce, Gd3Ga5O12:Eu3+, CdWO4) have been investigated. These were fabricated using sol-gel and liquid-phase epitaxy processes. Finally, the first fast microtomography experiment including radiation hardness of the optic is shown. This detector uses a high-intensity white beam with 60 keV effective energy and a fast CCD camera at up to 60 frames s(-1).

Journal Article↗

The application of fibre optics in self-teaching programmes in anatomy.

Self-teaching programmes in the form of tape/slide sequences have been used in the Department of Anatomy and Experimental Pathology, University of St Andrews, Scotland for a number of years and provide students with taped text and colour projections of two-dimensional drawings or diagrams. Such presentations are intended to replicate the lectures. Like anatomy departments elsewhere, anatomical and pathological specimens in museum pots have a fully-labelled photograph alongside to help identify specific anatomical structures. Recently, fibre optics have been introduced to illustrate anatomical features in prosections or museum specimens as a means of overcoming the drawbacks of a two dimensional illustration. A labelled push-button device has been constructed to illuminate optical fibres in order to identify and pinpoint anatomical structures in wet or dry specimens. Pinpoints of bright light are more readily seen than pin labels which also proved to be unsuitable in certain situations, such as within the skull foramina.

Anatomy↗

Material properties of the human lumbar facet joint capsule.

The human facet joint capsule is one of the structures in the lumbar spine that constrains motions of vertebrae during global spine loading (e.g., physiological flexion). Computational models of the spine have not been able to include accurate nonlinear and viscoelastic material properties, as they have not previously been measured. Capsules were tested using a uniaxial ramp-hold protocol or a haversine displacement protocol using a commercially available materials testing device. Plane strain was measured optically. Capsules were tested both parallel and perpendicular to the dominant orientation of the collagen fibers in the capsules. Viscoelastic material properties were determined. Parallel to the dominant orientation of the collagen fibers, the complex modulus of elasticity was E*=1.63MPa, with a storage modulus of E'=1.25MPa and a loss modulus of: E" =0.39MPa. The mean stress relaxation rates for static and dynamic loading were best fit with first-order polynomials: B(epsilon) = 0.1110epsilon-0.0733 and B(epsilon)= -0.1249epsilon + 0.0190, respectively. Perpendicular to the collagen fiber orientation, the viscous and elastic secant moduli were 1.81 and 1.00 MPa, respectively. The mean stress relaxation rate for static loading was best fit with a first-order polynomial: B (epsilon) = -0.04epsilon - 0.06. Capsule strength parallel and perpendicular to collagen fiber orientation was 1.90 and 0.95 MPa, respectively, and extensibility was 0.65 and 0.60, respectively. Poisson's ratio parallel and perpendicular to fiber orientation was 0.299 and 0.488, respectively. The elasticity moduli were nonlinear and anisotropic, and capsule strength was larger aligned parallel to the collagen fibers. The phase lag between stress and strain increased with haversine frequency, but the storage modulus remained large relative to the complex modulus. The stress relaxation rate was strain dependent parallel to the collagen fibers, but was strain independent perpendicularly.

Adult↗

Centered reduced moments and associate density functions applied to alkaline comet assay.

The single cell gel electrophoresis assay is a sensitive, rapid, and visual technique for deoxyribonucleic acid (DNA) strand-break detection in individual mammalian cells, whose application has significantly increased in the past few years. The cells are embedded in agarose on glass slides followed by lyses of the cell membrane. Thereafter, damaged DNA strands are electrophoresed away from the nucleus towards the anode giving the appearance of a comet tail. Nowadays, charge coupled device cameras are attached at optical microscopes for recording the images of the cells, and digital image processing is applied for obtaining quantitative descriptors. However, the conventional software is usually expensive, inflexible and, in many cases, can only provide low-order descriptors based in image segmentation, determination of centers of mass, and Euclidean distances. Associated density functions and centered reduced moments offer an effective and flexible alternative for quantitative analysis of the comet cells. We will show how the position of the center of mass, the lengths and orientation of the main semiaxes, and the eccentricity of such images can be accurately determined by this method.

Algorithms↗

Evaluation of a device for indirect assessment of automatic exposure control systems.

A test device which can indirectly measure the performance of an automatic exposure control system and which offers the potential to reduce the time and film requirements for such tests has been evaluated. Evaluation results demonstrate that the device can successfully predict image optical density to within +/- 0.10 optical density units over a wide range of imaging technical factors and image optical densities.

Biophysical Phenomena↗

Sub-diffraction-limited optical imaging with a silver superlens.

Recent theory has predicted a superlens that is capable of producing sub-diffraction-limited images. This superlens would allow the recovery of evanescent waves in an image via the excitation of surface plasmons. Using silver as a natural optical superlens, we demonstrated sub-diffraction-limited imaging with 60-nanometer half-pitch resolution, or one-sixth of the illumination wavelength. By proper design of the working wavelength and the thickness of silver that allows access to a broad spectrum of subwavelength features, we also showed that arbitrary nanostructures can be imaged with good fidelity. The optical superlens promises exciting avenues to nanoscale optical imaging and ultrasmall optoelectronic devices.

Journal Article↗

Effect of carbogen, oxygen and intraocular pressure on Heidelberg retina flowmeter parameter 'flow' measured at the papilla.

The aim of the study was to evaluate whether the Heidelberg retina flowmeter (HRF), a new device for retinal and anterior optic nerve blood flow assessment, can gauge, at least semiquantitatively, a known effect such as an increase in optic nerve blood flow by hypercapnia or a decrease in optic nerve blood flow by hyperoxia or high intraocular pressure (IOP). Measurements with the HRF were obtained at the papilla of three groups of 5 young healthy subjects (1) at baseline and after breathing 5% carbogen, (2) at baseline and after breathing 100% oxygen and (3) at baseline and after increasing IOP to 20 and 50 mm Hg. The changes in the value of the HRF parameter 'flow' were analyzed by means of a paired Student's t test. Breathing 100% oxygen for 7 min resulted in a statistically significant decrease of 34.7+/-2.5% (mean+/-SEM) in HR parameter 'flow' (p < 0.01) at the papilla. Breathing 5% carbogen for 7 min resulted in a statistically significant increase of 18.3+/-2.6% in HRF parameter 'flow' (p = 0.024). Increasing IOP to 20 mm Hg did not result in a statistically significant change in HRF parameter 'flow' (-9.6+/-7.4%; p = 0.13). Increasing IOP from 20 to 50 mm Hg, however, resulted in a statistically significant decrease of 40.1+/-6.6% in HRF parameter 'flow' (p = 0.003). With the applied stimuli, the HRF parameter 'flow' changed in the expected direction, i.e. an increase with hypercapnia and a decrease with hyperoxia or high IOP. The simplicity of use of the HRF instrument suggests that it might be well suited for a non-invasive, at least semiquantitative, assessment of changes in blood flow at the papilla.

Adult↗

Molecular imaging of cardiac cell transplantation in living animals using optical bioluminescence and positron emission tomography.

BACKGROUND: The current method of analyzing myocardial cell transplantation relies on postmortem histology. We sought to demonstrate the feasibility of monitoring transplanted cell survival in living animals using molecular imaging techniques. METHODS AND RESULTS: For optical bioluminescence charged-coupled device imaging, rats (n=20) underwent intramyocardial injection of embryonic rat H9c2 cardiomyoblasts (3x10(6) to 5x10(5)) expressing firefly luciferase (Fluc) reporter gene. Cardiac bioluminescence signals were present for more than 2 weeks with 3x10(6) cells: day 1 (627 000+/-15%), day 2 (346 100+/-21%), day 4 (112 800+/-20%), day 8 (78 860+/-24%), day 12 (67 780+/-12%), and day 16 (62 200+/-5% p x s(-1) x cm(2-1) x sr(-1)). For micro-positron emission tomography imaging, rats (n=20) received cardiomyoblasts (3x10(6)) expressing mutant herpes simplex type 1 thymidine kinase (HSV1-sr39tk) reporter gene. Detailed tomography of transplanted cells is shown by 9-(4-[18F]-fluoro-3hydroxymethylbutyl)guanine ([18F]-FHBG) reporter probe and nitrogen-13 ammonia ([13N]-NH3) perfusion images. Within the transplanted region, there was a 4.48+/-0.71-fold increase of in vivo [18F]-FHBG activity and a 4.01+/-0.51-fold increase of ex vivo gamma counting compared with control animals. Finally, the in vivo images of cell survival were confirmed by ex vivo autoradiography, histology, immunohistochemistry, and reporter protein assays. CONCLUSIONS: The location(s), magnitude, and survival duration of embryonic cardiomyoblasts were monitored noninvasively. With further development, molecular imaging studies should add critical insights into cardiac cell transplantation biology.

Animals↗

Fabrication of vertical ZnO nanowires on silicon (100) with epitaxial ZnO buffer layer.

Vertical ZnO nanowires were successfully grown on epitaxial ZnO (002) buffer layer/Si (100) substrate. The nanowire growth process was controlled by surface morphology and orientation of the epitaxial ZnO buffer layer, which was deposited by radio-frequency (rf) sputtering. The copper catalyzed the vapor-liquid-solid growth of ZnO nanowires with diameter of approximately 30 nm and length of approximately 5.0 microm. The perfect wurtzite epitaxial structure (HCP structure) of the ZnO (0002) nanowires synthesized on ZnO (002) buffer layer/Si (100) substrate results in excellent optical characteristics such as strong UV emission at 380 nm with potential use in nano-optical and nano-electronic devices.

Adsorption↗

Frameless stereotactic cannulation of the foramen ovale for ablative treatment of trigeminal neuralgia.

OBJECTIVE: Ablative neurosurgical treatment of trigeminal neuralgia, including percutaneous radiofrequency thermocoagulation, requires cannulation of the foramen ovale. To maximize patient security and cannulation success, a frameless stereotactic system was evaluated in a phantom study, a cadaveric study, and a preliminary clinical trial. METHODS: Frameless stereotaxy using an optical navigation system, an aiming device, and a noninvasive vacuum mouthpiece-based registration and patient fixation technique was used for the targeting of a test body based on 1-, 3-, and 5-mm axial computed tomographic slices and of the foramen ovale in three cadavers and 15 patients based on 3-mm axial computed tomographic slices. RESULTS: The mean normal (x/y) localization accuracy/standard deviation (n = 360) was 1.31/0.67 mm (1-mm slices), 1.38/0.65 mm (3-mm slices), and 1.84/0.96 mm (5-mm slices). Significantly better results were achieved with 1- and 3-mm slices when compared with 5-mm slices (P < 0.001). The foramen ovale (3 x 6 mm) was successfully cannulated at the first attempt in all cadavers and patients, which indicates clinical localization accuracies better than 1.5 mm in the anteroposterior and 3 mm in the medial-lateral directions. CONCLUSION: Based on the noninvasive Vogele-Bale-Hohner vacuum mouthpiece, there is no need for invasive head clamp fixation. Imaging, real laboratory simulation, and the actual surgical intervention can be separated in time and location. The presented data suggest that frameless stereotaxy is a predictable and reproducible procedure, which may enhance patient security and cannulation success independent of the surgeon's experience.

Aged↗