Chord-based versus voxel-based methods of electron transport in the skeletal tissues.

Anatomic models needed for internal dose assessment have traditionally been developed using mathematical surface equations to define organ boundaries, shapes, and their positions within the body. Many researchers, however, are now advocating the use of tomographic models created from segmented patient computed tomography (CT) or magnetic resonance (MR) scans. In the skeleton, however, the tissue structures of the bone trabeculae, marrow cavities, and endosteal layer are exceedingly small and of complex shape, and thus do not lend themselves easily to either stylistic representations or in-vivo CT imaging. Historically, the problem of modeling the skeletal tissues has been addressed through the development of chord-based methods of radiation particle transport, as given by studies at the University of Leeds (Leeds, U.K.) using a 44-year male subject. We have proposed an alternative approach to skeletal dosimetry in which excised sections of marrow-intact cadaver spongiosa are imaged directly via microCT scanning. The cadaver selected for initial investigation of this technique was a 66-year male subject of nominal body mass index (22.7 kg m(-2)). The objectives of the present study were to compare chord-based versus voxel-based methods of skeletal dosimetry using data from the UF 66-year male subject. Good agreement between chord-based and voxel-based transport was noted for marrow irradiation by either bone surface or bone volume sources up to 500-1000 keV (depending upon the skeletal site). In contrast, chord-based models of electron transport yielded consistently lower values of the self-absorbed fraction to marrow tissues than seen under voxel-based transport at energies above 100 keV, a feature directly attributed to the inability of chord-based models to account for nonlinear electron trajectories. Significant differences were also noted in the dosimetry of the endosteal layer (for all source tissues), with chord-based transport predicting a higher fraction of energy deposition than given by voxel-based transport (average factor of about 1.6). The study supports future use of voxel-based skeletal models which (1) permit nonlinear electron trajectories across the skeletal tissues, (2) do not rely on mathematical algorithms for treating the endosteal tissue layer, and (3) do not implicitly assume independence of marrow and bone trajectories as is the case for chord-based skeletal models.

Aged↗

Examination of the factors Ac and Aeq for cylindrical ion chambers used in cobalt-60 beams.

The calibration of a cobalt-60 beam in a phantom with an ion chamber, which has been calibrated with respect to exposure, requires the use of a displacement correction factor which essentially corrects the photon fluence for the attenuation and scatter when the chamber with buildup cap is removed and replaced by phantom material. To determine the displacement factor, Ac, a special set of cylindrical ionization chambers with various volumes were constructed out of polystyrene. Tissue-air ratios were measured with these chambers for cobalt-60 gamma rays in a polystyrene phantom, and the ratio Ac/Aeq was experimentally determined. In order to calculate Ac from this ratio, Aeq was determined also. It was found that Ac depended on chamber diameter only, and not on field size or depth. A value of 0.990 for Aeq is recommended and a table of Ac for chambers of different outer diameters is included.

Cobalt Radioisotopes↗

Systmatic method of formulating liquid phantoms with a given elemental composition and density.

A general method of formulating tissue equivalent liquid mixtures of a given chemical composition and density using the technique of linear programming is described. It is used to generate mixtures with equivalent atomic composition as ICRP Standard Man and mammalian muscle (NBS Handbook 85) using eight compounds to cover the range of densities from 1.0 to 1.13. Use of the method to handle other parameters of a mixture is also described.

Body Burden↗

The effects of motion on quantitative vessel measurements.

Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demonstrated experimentally. Although the densitometric cross-sectional area is shown to be independent of motion, densitometric thickness (contrast) decreases and the apparent width (distance between edges) and densitometric width both increase with motion. Knowledge of the velocity allows the apparent width but not the densitometric width to be corrected. It is also shown that current limitations which result in tradeoffs between kVp and x-ray pulse duration seriously compromise the advantages of using small focal spots in coronary artery imaging.

Coronary Angiography↗

The extended net fractional depth dose: correction for inhomogeneities, including effects of electron transport in photon beam dose calculation.

The extended net fractional depth dose (ENFD) is developed from the net fractional depth dose (NFD) previously described for unit-density media, basically by scaling the two geometric parameters, the side of the equivalent square field, and the depth along the ray by the relative electron density. Specifically, in the analytical description for the NFD, the geometric depth is replaced by the radiologic depth and, along the ray path, the geometric field side is scaled by the relative electron density. Interface effects on the electron and scattered-photon fluences are accounted for. In addition, a simple function is developed to correct for the effect of lateral as well as longitudinal electron transport at the central ray. In the present work the inhomogeneities are assumed to be of planar parallel shape and to extend across the entire beam. The treatment of smaller inhomogeneities is outlined but will be treated in detail separately. Calculated results are compared to measured and calculated data from the literature for 60Co and 10-MV x-rays, and to 15-MV data measured at the NCI.

Biophysical Phenomena↗

Calculation of the dose delivered to organs outside the radiation beams.

An organ dose calculation based on measurements is described which models the total dose delivered outside a beam from 10 to 50 cm from the field edge. The dose distribution is parametrized for each beam energy as a function of depth, distance from the edge, and field size and shape. The algorithm also takes into account the organ location relative to the beam. Comparisons with measurements in an Alderson phantom using thermoluminescent dosimetry are given for various typical treatments.

Cobalt Radioisotopes↗

Two algorithms for the three-dimensional reconstruction of tomograms.

Three-dimensional (3-D) surface reconstructions provide a method to view complex anatomy contained in a set of computed tomography (CT), magnetic resonance imaging (MRI), or single photon emission computed tomography tomograms. Existing methods of 3-D display generate images based on the distance from an imaginary observation point to a patch on the surface and on the surface normal of the patch. We believe that the normalized gradient of the original values in the CT or MRI tomograms provides a better estimate for the surface normal and hence results in higher quality 3-D images. Then two algorithms that generate 3-D surface models are presented. The new methods use polygon and point primitives to interface with computer-aided design equipment. Finally, several 3-D images of both bony and soft tissue show the skull, spine, internal air cavities of the head and abdomen, and the abdominal aorta in detail.

Algorithms↗

Investigation of basic imaging properties in digital radiography. 12. Effect of matrix configuration on spatial resolution.

We investigated the effects of three matrix configurations (a conventional 512 X 512 matrix, a double-sampling matrix, and a high-resolution 1024 X 1024 matrix) on the resolution properties of an image intensifier (II)-TV digital radiographic imaging system. Expressions for the optical transfer function were derived theoretically for each of the three matrix configurations, and the corresponding digital modulation transfer functions (MTF's) were calculated using the measured MTF's of the presampling analog components and the parameters of the digital system. In addition, digital images of a star pattern phantom and a hand phantom were obtained with the II-TV system for each matrix type. From our results, we conclude that, in order to increase the resolution of an II-TV digital imaging system, it is necessary not only to increase the matrix size, but also to improve the resolution capabilities of analog components such as the II and/or TV camera. In addition, if the system cannot be upgraded to a 1024 X 1024 matrix configuration, a double-sampling technique with an 512 X 512 matrix may be employed.

Hand↗

An evaluation of four methods of 111In planar image quantification.

The accurate quantification of the in vivo distribution of 111In labeled platelets, other cells, and proteins with a scintillation camera is important in clinical and experimental medicine. Planar techniques of image quantification were therefore evaluated with the aim of improving on the accuracy, and simplifying the techniques currently in use. The attenuation of the 172- and 247-keV photons of 111In, singly and in combination, was determined for varying diameter flat sources (3.4 to 16.9 cm). The influence of region of interest (ROI) selection on the shape of the attenuation curves was also determined for five different ROI's. Defining the attenuation curves mathematically generated parameters of fit for three approaches to in vivo quantification, namely: a single exponential geometric mean approach that takes into account source size, depth-dependent, and depth-independent buildup factor approaches to account for the contribution of scatter. The accuracy of these techniques was ascertained and compared to the classical geometric mean method. This was done in a waxen phantom of a human thorax with a hollow liver and spleen. The results indicated that the depth-independent buildup factor is the best method; the error for quantification in the spleen was 0.8% +/- 2.2%. The classical geometric mean approach gave a corresponding error of 43.3% +/- 3.4%. Since the attenuation of the two energies of 111In differ, their ratio changes with depth. This phenomenon was investigated with the goal of determining whether the depth of an object can be estimated from one set of planar images. This was not successful.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Platelets↗

Physical performance characteristics of spiral CT scanning.

CT scanning in spiral geometry is achieved by continuously transporting the patient through the gantry in synchrony with continuous data acquisition over a multitude of 360-deg scans. Data for reconstruction of images in planar geometry are estimated from the spiral data by interpolation. The influence of spiral scanning on image quality is investigated. Most of the standard physical performance parameters, e.g., spatial resolution, image uniformity, and contrast, are not affected; results differ for pixel noise and slice sensitivity profiles. For linear interpolation, pixel noise is expected to be reduced by a factor of 0.82; reduction factors of 0.81 to 0.83 were measured. Slice sensitivity profiles are changed as a function of table feed d, measured in millimeters per 360-deg scan; they are smoothed as the original profile is convolved with the object motion function. The motion function is derived for linear interpolation that constitutes a triangle with a base line width of 2d and a maximal height equal to 1/d. Calculations of both the full width at half-maximum and the shape of the profiles were in good agreement with experimental results. The effect of the widened profiles, in particular of their extended tail ends, on image quality is demonstrated in phantom measurements.

Humans↗

A modified power-law formula for inhomogeneity corrections in beams of high-energy x rays.

The Batho power-law formula is in common use in many treatment planning systems to correct for the presence of lungs and other inhomogeneities. While giving excellent agreement with measurement for Cobalt-60 radiation, it tends to underestimate the lung correction required for higher energy x rays and is undefined for distances beyond an interface less than the buildup distance. This paper suggests a simple modification that greatly improves the agreement with measured data and gives a continuously defined function at all depths. Measurements have been made in a polystyrene and cork phantom to simulate the effects of lung; data are presented for beams of 8-MV x rays, 16-MV x rays, and Cobalt-60 gamma rays.

Cobalt Radioisotopes↗

Backscatter coefficient imaging using a clinical scanner.

A clinical ultrasound scanner has been integrated with a digital data acquisition system to record echo signals for off-line processing of quantitative acoustic backscatter images. The method used to determine backscatter coefficients accounts for experimental factors related to the beam directivity function, the transmitting and receiving electronics, and the attenuation path of the beam. After characterization and calibration of the ultrasound scanner according to the data processing requirements, the quantitative backscatter coefficient for tissue-mimicking phantoms are within 14% of a value predicted by scattering theory. On five normal volunteers, preliminary in vivo liver images of the acoustic backscatter coefficient are obtained. Results from this study are compared to previously published in vitro results.

Humans↗

Two-radiograph reconstruction using six geometrical solution sets and least-squares method.

When two radiographic projections are available for reconstruction, it was found that six different combinations of equations could be used to obtain the geometrical solutions for the position of any point. No errors in the image coordinates read from the radiographs resulted in identical solutions for the six equations. Inaccuracies or errors present in the image coordinates generated differences among the six solutions. In this case, a least-squares method could be used to determine the optimum position. The utility of such a least-squares optimizing approach is presented in the context of a clinical example.

Brachytherapy↗

A simulation of emission and transmission noise propagation in cardiac SPECT imaging with nonuniform attenuation correction.

Transmission computed tomography provides information needed for nonuniform attenuation correction of cardiac single photon emission computed tomography (SPECT). Nonuniform attenuation correction is accomplished using an iterative ML-EM algorithm and a projection-backprojection operation that incorporates attenuation factors measured from the reconstructed transmission map. The precision and accuracy of the attenuation corrected emission reconstruction is a function of emission and transmission statistics. This paper presents an error propagation analysis that uses a mathematical cardiac chest phantom to simulate various combinations of total emission counts C and transmission flux I0 under ideal imaging conditions (without geometric response distortion and without scatter). The spatial average, spatial variance, and accuracy measures for a 4 x 4 pixel region in the heart are tabulated after 30 iterations of the ML-EM algorithm. The confidence intervals for these measures were determined from 1000 realizations of reconstructions from projections randomly generated with the same transmission and emission statistics. It can be shown empirically from the simulation results that the spatial %rms uncertainty for the simulated cardiac region has a simple expression: %rms2 = K1/C+K2/I0(2)+B2 where K1 and K2 are least-square estimates based on the simulation results, and B is the measured spatial %rms uncertainty for the simulation at infinite statistics. For a transmission incident flux of 1500 events per projection bin of 0.712 cm and typical clinical emission events totaling 1 x 10(5), the spatial %rms uncertainty is approximately 14%. At clinical transmission and emission statistics, the statistical noise in the simulated attenuation-corrected reconstructions are dominated by the emission statistics.

Algorithms↗

Computerized three-dimensional segmented human anatomy.

Manual segmentation of 129 x-ray CT transverse slices of a living male human has been done and a computerized 3-dimensional volume array modeling all major internal structures of the body has been created. Each voxel of the volume contains a index number designating it as belonging to a given organ or internal structure. The original x-ray CT images were reconstructed in a 512 x 512 matrix with a resolution of 1 mm in the x,y plane. The z-axis resolution is 1 cm from neck to midthigh and 0.5 cm from neck to crown of the head. This volume array represents a high resolution model of the human anatomy and can serve as a voxel-based anthropomorphic phantom suitable for many computer-based modeling and simulation calculations.

Computer Simulation↗

On three-dimensional dose calculation of photon beam with wedge filters.

A wedge filter is one of the most commonly used beam modifying devices. The introduction of a wedge filter alters both the distribution of the primary photon fluence and the first and second scatter patterns. The effect of the wedge filter is normally expressed in terms of an exponential attenuation function that is used to modify the primary photon fluence. This paper describes a new three-dimensional (3-D) wedged field dose calculation algorithm. This algorithm automatically takes into account (1) the scatter distribution pattern correction due to the effect of wedge filters and (2) the fixed primary photon fluence correction, by utilizing a tissue maximum ratio table calculated from the measured percent depth dose of the wedge, a measured in-plane scan and a measured cross-plane scan of the largest rectangular wedge field size. As a result, the calculation accuracy achieved by this algorithm is better than the calculation accuracy achieved by other algorithms. The results show better than 1% accuracy of the wedge central axis percent depth dose calculation and better than 3% accuracy of the off-axis dose calculation when compared with measurements.

Humans↗

Diode dosimetry of 103Pd model 200 seed in water phantom.

The relative dose distribution around the 103Pd model 200 implant seed was measured with a computerized data acquisition system employing a p-n junction silicon diode immersed in a water phantom. Data are acquired in polar coordinates by computer control of (1) the diode distance from the seed center and (2) the rotation angle of seed about a transverse axis. Transverse axis data are compared with thermoluminescent dosimeter (TLD) measurements and a Monte Carlo calculation by others.

Brachytherapy↗

An objective method for evaluating electronic portal imaging devices.

A statistical technique is described for analyzing the image of a contrast-detail phantom acquired by a radiotherapy electronic portal imaging device. By using Student's t test, the image analysis algorithm computes which holes in the contrast-detail phantom can be objectively resolved from the background signal. The specific pattern of the resolved holes and the total number of the resolved holes characterize the performance of the electronic portal imaging device. Image processing techniques are used to align the holes automatically. Because the use of this algorithm is completely automated, the procedure removes operator subjectivity from the evaluation.

Algorithms↗