Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Miniaturization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.

The performance of an amperometric biosensor, consisting of a subcutaneously implanted miniature (0.29 mm diameter, 5 x 10(-4) cm2 mass transporting area), 90 s 10-90% rise/decay time glucose electrode, and an on-the-skin electrocardiogram Ag/AgCl electrode was tested in an unconstrained, naturally diabetic, brittle, type I, insulin-dependent chimpanzee. The chimpanzee was trained to wear on her wrist a small electronic package and to present her heel for capillary blood samples. In five sets of measurements, averaging 5 h each, 82 capillary blood samples were assayed, their concentrations ranging from 35 to 400 mg/dl. The current readings were translated to blood glucose concentration by assaying, at t = 1 h, one blood sample for each implanted sensor. The rms error in the correlation between the sensor-measured glucose concentration and that in capillary blood was 17.2%, 4.9% above the intrinsic 12.3% rms error of the Accu-Chek II reference, through which the illness of the chimpanzee was routinely managed. Linear regression analysis of the data points taken at t>1 h yielded the relationship (Accu-Chek) = 0. 98 x (implanted sensor) + 4.2 mg/dl, r2 = 0.94. The capillary blood and the subcutaneous glucose concentrations were statistically indistinguishable when the rate of change was less than 1 mg/(dl. min). However, when the rate of decline exceeded 1.8 mg/(dl.min) after insulin injection, the subcutaneous glucose concentration was transiently higher.

Animals↗

Recent, extensive, and preferential insertion of members of the miniature inverted-repeat transposable element family Heartbreaker into genic regions of maize.

A 314-bp DNA element called Heartbreaker-hm1 (Hbr-hm1) was previously identified in the 3' untranslated region of a mutant allele of the maize disease resistance gene HM1. This element has structural features of miniature inverted-repeat transposable elements (MITEs) and is a member of a large family of approximately 4,000 copies in the maize genome. Unlike previously described MITEs, most members of the Hbr family display over 90% sequence identity. This, coupled with the insertion of an Hbr element into an allele of the HM1 gene, suggested that this family might have spread recently throughout the genome. Consistent with this view is the finding that Hbr insertion sites are remarkably polymorphic. Ten of ten loci containing Hbr elements were found to be polymorphic for the presence or absence of Hbr among a collection of maize inbred lines and teosinte strains. Despite the fact that over 80% of the maize genome contain moderate to highly repetitive DNA, we find that randomly chosen Hbr elements are predominantly in single or low copy regions. Furthermore, when used to query both the public and private databases of plant genes, over 50% of the sequences flanking these Hbr elements resulted in significant "hits." Taken together, these data indicate that the presence or absence of Hbr elements is a significant contributory factor to the high level of polymorphism associated with maize genic regions.

Base Sequence↗

Eight novel families of miniature inverted repeat transposable elements in the African malaria mosquito, Anopheles gambiae.

Eight novel families of miniature inverted repeat transposable elements (MITEs) were discovered in the African malaria mosquito, Anopheles gambiae, by using new software designed to rapidly identify MITE-like sequences based on their structural characteristics. Divergent subfamilies have been found in two families. Past mobility was demonstrated by evidence of MITE insertions that resulted in the duplication of specific TA, TAA, or 8-bp targets. Some of these MITEs share the same target duplications and similar terminal sequences with MITEs and other DNA transposons in human and other organisms. MITEs in A. gambiae range from 40 to 1340 copies per genome, much less abundant than MITEs in the yellow fever mosquito, Aedes aegypti. Statistical analyses suggest that most A. gambiae MITEs are in highly AT-rich regions, many of which are closely associated with each other. The analyses of these novel MITEs underscored interesting questions regarding their diversity, origin, evolution, and relationships to the host genomes. The discovery of diverse families of MITEs in A. gambiae has important practical implications in light of current efforts to control malaria by replacing vector mosquitoes with genetically modified refractory mosquitoes. Finally, the systematic approach to rapidly identify novel MITEs should have broad applications for the analysis of the ever-growing sequence databases of a wide range of organisms.

Africa↗

Role of modified CDC miniature light-traps as an alternative method for sampling adult anophelines (Diptera: Culicidae) in the National Mosquito Surveillance Programme in India.

The efficiency of modified CDC miniature light-traps for sampling adult mosquitoes was evaluated in comparison with indoor resting, outdoor resting, indoor man-landing and outdoor man-landing collections in the hilly district of Koraput, Orissa, India. Overall, light-traps captured 78% of adult mosquitoes collected by all methods. Of the 16 anopheline species recorded in the study area, light-traps effectively sampled 13, contributing about 72% of the total anophelines collected by all methods. Light-traps also caught a large number of female Culex vishnui Theobald (96%). As fully-fed mosquitoes were predominant (82%) and caught alive, light-traps can be used to catch large numbers of vector mosquitoes for studies on vector prevalence, distribution, vector incrimination and also for laboratory bioassays. Light-trap and indoor resting collections revealed similar seasonal trends in numbers of Anopheles culicifacies Giles, A. fluviatilis James, A. jeyporiensis James, A. vagus Doenitz, and A. splendidus Koidzumi. Age-structure of the samples did not vary significantly between the two methods. Light-traps could be used as an alternative to daytime indoor resting collections to monitor the seasonal fluctuations in the abundance and parity rates of these species. The light-trap collections correlated with indoor and outdoor man-landing collections of A. jeyporiensis and the outdoor man-landing collections of A. maculatusTheobald in measuring seasonal trends. Light-trap collections can thus be used as a substitute for man-landing collections of A. jeyporiensis and A. maculatus.

Animals↗

A miniature and mobile intermittent pneumatic compression device for the prevention of deep-vein thrombosis after joint replacement.

The WizAir-DVT is a miniature, lightweight (690 g), battery-operated and mobile intermittent pneumatic compression device (ICD), which enables continuous intraoperative use and immediate patient mobilization postoperatively. We compared its efficacy with a commonly used ICD, the Kendall SCD. Peak femoral vein flow velocity was measured in 20 apparently healthy volunteers at rest and with each device: we found no significant differences between them. A second prospective, randomized, clinical trial was used to compare the efficiency of the device in preventing deep venous thrombosis (DVT) after joint replacement in 50 patients (n=25/group). None developed DVT. Doppler ultrasonography revealed no significant differences. The WizAir-DVT antithrombotic compression device is as safe and effective as the Kendall SCD.

Arthroplasty, Replacement↗

Cobalt metal inhalation studies on miniature swine.

Cobalt is considered to be the chief component in the tungsten carbide mixture responsible for hard-metal disease. An animal inhalation study was undertaken simulating conditions under which these workers in the tungsten carbide industry are exposed to cobalt. In this semichronic study, miniature swine were exposed to an inhalation of pure cobalt metal powder at concentrations of 0.1% mg/m3 (present TLV) and 1.0 m/m3. At peroidic intervals, the following studies were performed: pulmonary function tests, electrocardiograms, x-ray examinations, blood and urine tests, electron microscopy, and light microscopic pathology. Early detection of pulmonary disease is apparent from the pulmonary function tests showing a mark decrease in lung compliance, and from electron microscopy showing an increase in the amount of septal collagen. This study demonstrates that the present TLV of 0.1 mg/3 for cobalt seems to be too high, even at this relatively brief duration of exposure.

Airway Resistance↗

Evaluation of esophageal motility by endosonography using a miniature ultrasonographic probe in patients with reflux esophagitis.

BACKGROUND: Although there are several established methods used to evaluate esophageal motility, none allows for direct observation of esophageal wall motion. Esophageal dysmotility is thought to contribute to reflux esophagitis (RE). The aim of this study was to evaluate esophageal wall motility by endosonography using a miniature ultrasonographic probe (MUP) in patients with RE. METHODS: The subjects consisted of 10 healthy controls (10 men with a mean age of 31.5 years) and 9 patients with RE (4 men and 5 women with a mean age of 51.5 years). High-frequency endoluminal sonography was performed using a 20-MHz transducer through a 16F gastric tube to evaluate esophageal wall motion. Four sonographic phases of an esophageal peristaltic sequence were identified. In the resting phase, the esophageal wall was in direct contact with the transducer. In the passive distention phase, the esophageal lumen was stretched maximally; in the contraction phase, it contracted; and in the relaxation phase, it returned to baseline. The baseline thickness of the muscle layers of the esophageal wall was measured at rest. The width decreased during the passive distention phase, increased and reached a maximum during the contraction phase, and returned to baseline during the relaxation phase. RESULTS: The contractility index of the circular smooth muscle (CSM) in the distal esophagus and of the longitudinal smooth muscle (LSM) in the proximal esophagus were significantly lower in patients with RE. The duration of contraction in the distal esophagus was significantly longer in RE. CONCLUSIONS: We used a MUP to demonstrate abnormalities in esophageal wall motility in patients with RE. We conclude that the MUP is a potentially useful technique for evaluating esophageal dysmotility.

Adult↗

Use of miniature ultrasonic probe system for intravesical ultrasonography for transitional cell cancer of the urinary tract.

OBJECTIVE: We describe the use of a miniature ultrasonic probe (MUP) system for intravesical ultrasonography for staging of urinary bladder and/or ureteral tumors. MATERIAL AND METHODS: Seventeen patients with bladder tumors were enrolled in this study. Probes (8 F; 15 and 20 MHz) were inserted through a channel in a 22 F rigid cystoscopy sheath. RESULTS: Using the MUP, each tumor could be scanned under simultaneous cystoscopic observation to choose the optimal probe position. However, in 4 of 17 patients optimal scanning could not be obtained because of large tumors and poor ultrasound penetration or because of tumor localization at the anterior dome which did not allow an appropriate scanning plane for staging. Of 13 evaluable patients, 5 with no interruption or folding of the low-echoic muscle layer were diagnosed as having a superficial tumor, and this was confirmed histopathologically in all but one case. All 8 cases evaluated as having invasive tumors demonstrated muscle invasion histologically. CONCLUSION: The MUP can be more easily manipulated than a conventional probe.

Adult↗

Endocrine alopecia in a miniature poodle.

Hypothyroidism and concurrent sex hormone imbalance associated with alopecia was diagnosed in a 5 year-old entire male Miniature Poodle. The dog had a 3-year history of alopecia, seborrhoea and recurrent superficial pyoderma. Abnormal thyrotropin releasing hormone stimulation test results supported a diagnosis of hypothyroidism. Partial hair regrowth occurred after interstitial cell tumours, which were present in both testicles, were removed by castration. Complete hair regrowth, however, occurred only after thyroid hormone supplementation. This case highlighted difficulties which may be encountered when interpreting serum hormone concentrations and endocrine function tests.

Journal Article↗

Evaluation of a miniature antimony electrode for measurement of myocardial pH.

Myocardial pH reflects the metabolic status of the heart and pH monitoring is an invaluable way to monitor the efficacy of myocardial protection during cardiac surgery. We developed a miniature antimony electrode for pH measurement in the heart. We examined the sensitivity, accuracy and the effects of temperature and oxygen tension on pH readings with this electrode in standard buffers and in anaesthetized dogs. In buffers the antimony electrode exhibited a gradient of -50.3 +/- 1.8 mV pH-1 at 25 degrees C, close to the Nernstian slope and showed a high correlation with conventional glass electrode readings (mean difference 0.027 +/- 0.0035 pH, r2 = 0.97). With increasing temperature the antimony electrode pH readings increased by 0.03 +/- 0.002 pH degree C(-1). With increasing PO2 the pH reading decreased (-0.73 pH/log PO2 mm Hg, r2 = 0.96). In the dog heart the antimony electrode showed a decrease in myocardial pH with increasing PCO2, and an increase in pH when NaHCO3 was given intravenously. Coronary occlusion resulted in paradoxically higher pH readings with the antimony electrode due to the effect of lowered myocardial PO2 interfering with pH measurement. The dissolution of antimony from the electrode in blood plasma was tested and found to be low. These studies suggest that antimony electrodes have low toxicity and provide accurate pH determinations under conditions of constant PO2. For more widespread clinical application, the problem of oxygen interference needs to be solved.

Animals↗

Prenatal protein malnutrition results in increased frequency of miniature inhibitory postsynaptic currents in rat CA3 interneurons.

Electrophysiological studies have revealed an increase in the level of tonic inhibition in the hippocampus following prenatal protein malnutrition in rats. In the present study, whole cell patch clamp recordings of bipolar interneurons in the stratum radiatum of the CA3 subfield were used to determine whether this increase in inhibition can be accounted for by a change in the electrophysiological properties of GABAergic interneurons. Hippocampal slices were prepared from juvenile rats whose dams were fed either a normal (25% casein) or low (6% casein) protein diet throughout pregnancy. Intrinsic membrane and action potential properties were unaltered by the prenatal nutritional insult. In most respects the characteristics of GABAA receptor-mediated inhibitory postsynaptic currents (IPSCs) and the modulation of such currents by the benzodiazepine agonist zolpidem were also similar in cells from the two nutritional groups. While the frequency of spontaneous inhibitory currents was unaltered, miniature (Tetrodotoxin resistant) inhibitory currents occurred at a significantly increased frequency in interneurons from prenatally protein malnourished rats. Thus, while the basic membrane properties of interneurons are preserved, there is a significant increase in the probability of GABA release from interneurons following prenatal protein malnutrition.

Action Potentials↗

Comparison of the Fourier transform infrared (FTIR) spectrophotometer and the Miniature Infrared Analyzer (MIRAN) for the determination of trichloroethylene (TCE) in the presence of Freon-113 in workplace air.

Results obtained using the Fourier transform infrared spectrophotometer (FTIR) and the Miniature Infrared Analyzer (MIRAN) for samples of workplace air containing trichloroethylene (TCE) were evaluated through comparison with results obtained when using a gas chromatography (GC). The effects of instrument resolution, relative humidity, and sample storage stability were studied. Relative humidity was found to have no effect on the performance of the FTIR over the range studied. The effect of changing resolution is complex but is explained. The linear range of the FTIR is more than adequate for the concentrations encountered in the samples reported in this study. Interference from Freon caused the TCE values to be high when the MIRAN was operated in the single-wavelength mode.

Air Pollutants, Occupational↗

Miniature anechoic chamber for chronic exposure of small animals to plane-wave microwave fields.

A system of miniature anechoic chambers for chronically exposing a sizeable number of animals to microwave radiation was developed in which each animal can be individually exposed to microwaves or sham-exposed under controlled environmental conditions. Each animal is supplied with food and water by means designed to eliminate undesirable perturbations of the field. Field patterns in each chamber correspond closely to those made in large anechoic chambers; measurements indicate that a power density of 169 microW/cm2 per watt of input power can be provided, which results in peak SAR levels of 0.37 W/kg in cadavers of exposed rats.

Animals↗

A new miniature hydrostatic pressure chamber for microscopy. Strain-free optical glass windows facilitate phase-contrast and polarized-light microscopy of living cells. Optional fixture permits simultaneous control of pressure and temperature.

This paper describes the development of a miniature, temperature-controlled, stainless steel pressure chamber which uses strain-free optical glass for windows. It is directly adaptable to standard phase-contrast and polarized-light microscopes and requires a minimum amount of equipment to generate and measure pressure. Birefringence retardation (BR) og 0.1 nm up to 3,000 psi, 0.4 nm up to 5,000 psi and 1.0 nm up to 10,000 psi can be detected over a 0.75-mm central field with two strain-free Leitz 20 times UM objectives, one used as a condenser. In phase-contrast studies a Nikon DML 40 times phase objective and Zeiss model IS long working-distance phase condenser were used, with little deterioration of image quality or contrast at pressures as high as 12,000 psi. The actual design process required a synthesis of various criteria which may be categorized under four main areas of consideration: (a) specimen physiology; (b) constraints imposed by available optical equipment and standard microscope systems; (c) mechanical strength and methods for generating pressure; and (d) optical requirements of the chamber windows. Procedures for using the chambers, as well as methods for shifting and controlling the temperature within the chamber, are included.

Atmosphere Exposure Chambers↗

Mechanism of generation of spontaneous miniature outward currents (SMOCs) in retinal amacrine cells.

A subtype of retinal amacrine cells displayed a distinctive array of K(+) currents. Spontaneous miniature outward currents (SMOCs) were observed in the narrow voltage range of -60 to -40 mV. Depolarizations above approximately -40 mV were associated with the disappearance of SMOCs and the appearance of transient (I(to)) and sustained (I(so)) outward K(+) currents. I(to) appeared at about -40 mV and its apparent magnitude was biphasic with voltage, whereas I(so) appeared near -30 mV and increased linearly. SMOCs, I(to), and a component of I(so) were Ca(2+) dependent. SMOCs were spike shaped, occurred randomly, and had decay times appreciably longer than the time to peak. In the presence of cadmium or cobalt, SMOCs with pharmacologic properties identical to those seen in normal Ringer's could be generated at voltages of -20 mV and above. Their mean amplitude was Nernstian with respect to [K(+)](ext) and they were blocked by tetraethylammonium. SMOCs were inhibited by iberiotoxin, were insensitive to apamin, and eliminated by nominally Ca(2+)-free solutions, indicative of BK-type Ca(2+)-activated K(+) currents. Dihydropyridine Ca(2+) channel antagonists and agonists decreased and increased SMOC frequencies, respectively. Ca(2+) permeation through the kainic acid receptor had no effect. Blockade of organelle Ca(2+) channels by ryanodine, or intracellular Ca(2+) store depletion with caffeine, eradicated SMOCs. Internal Ca(2+) chelation with 10 mM BAPTA eliminated SMOCs, whereas 10 mM EGTA had no effect. These results suggest a mechanism whereby Ca(2+) influx through L-type Ca(2+) channels and its subsequent amplification by Ca(2+)-induced Ca(2+) release via the ryanodine receptor leads to a localized elevation of internal Ca(2+). This amplified Ca(2+) signal in turn activates BK channels in a discontinuous fashion, resulting in randomly occurring SMOCs.

3-Pyridinecarboxylic acid, 1,4-dihydro-2,6-dimethy↗

Calcium-induced transitions between the spontaneous miniature outward and the transient outward currents in retinal amacrine cells.

Spontaneous miniature outward currents (SMOCs) occur in a subset of retinal amacrine cells at membrane potentials between -60 and -40 mV. At more depolarized potentials, a transient outward current (I(to)) appears and SMOCs disappear. Both SMOCs and the I(to) are K(+) currents carried by BK channels. They both arise from Ca(2+) influx through high voltage-activated (HVA) Ca(2+) channels, which stimulates release of internal Ca(2+) from caffeine- and ryanodine-sensitive stores. An increase in Ca(2+) influx resulted in an increase in SMOC frequency, but also led to a decline in SMOC mean amplitude. This reduction showed a temporal dependence: the effect being greater in the latter part of a voltage step. Thus, Ca(2+) influx, although required to generate SMOCs, also produced a negative modulation of their amplitudes. Increasing Ca(2+) influx also led to a decline in the first latency to SMOC occurrence. A combination of these effects resulted in the disappearance of SMOCs, along with the concomitant appearance of the I(to) at high levels of Ca(2+) influx. Therefore, low levels of Ca(2+) influx, arising from low levels of activation of the HVA Ca(2+) channels, produce randomly occurring SMOCs within the range of -60 to -40 mV. Further depolarization leads to greater activation of the HVA Ca(2+) channels, larger Ca(2+) influx, and the disappearance of discontinuous SMOCs, along with the appearance of the I(to). Based on their characteristics, SMOCs in retinal neurons may function as synaptic noise suppressors at quiescent glutamatergic synapses.

3-Pyridinecarboxylic acid, 1,4-dihydro-2,6-dimethy↗

Multimodal distribution of frog miniature endplate potentials in adult denervated and tadpole leg muscle.

Amplitude histograms of spontaneous miniature endplate potentials (MEPPs) from adult sartorius muscle cells show a definite bimodality with the mean amplitude of the larger mode five to seven times that of the smaller mode which accounted for 2-5 % of the total MEPPs. Histograms were plotted after high frequency MEPP generation induced by increasing temperature, increasing external calcium or nerve stimulation. These plots showed a reversible left-shift of the major mode as well as a reversible increase in the proportion of small mode MEPPs. Repeated challenges shifted almost all MEPPs into the small mode. An increase in the percentage of small mode MEPPs also occurred spontaneously during the course of denervation before the quiescent period and some of the histogram profiles showed multiple modes whose means were integer multiples of the small mode mean. In the early stages of hind leg development the greatest proportion of MEPPs were of the small mode size; as metamorphosis progressed, the histograms showed a definite multimodality with the mean of each mode being an integer multiple of the small mode mean and with the proportion of MEPPs in each mode about the same. During tail resorption the percentage of larger MEPPs increased until the adult histogram profile was reached. Thus, the changes in MEPP amplitude histograms over the course of metamorphosis are the reverse of those found with denervation.

Animals↗

Changes in miniature endplate potential frequency during repetitive nerve stimulation in the presence of Ca2+, Ba2+, and Sr2+ at the frog neuromuscular junction.

Miniature endplate potentials (MEPPs) were recorded from frog sartorious neuromuscular junctions under conditions of reduced quantal contents to study the effect of repetitive nerve stimulation on asynchronous (tonic) quantal transmitter release. MEPP frequency increased during repetitive stimulation and then decayed back to the control level after the conditioning trains. The decay of the increased MEPP frequency after 100-to 200-impulse conditioning trains can be described by four components that decayed exponentially with time constants of about 50 ms, 500 ms, 7 s, and 80 s. These time constants are similar to those for the decay of stimulation-induced changes in synchronous (phasic) transmitter release, as measured by endplate potential (EPP) amplitudes, corresponding, respectively, to the first and second components of facilitation, augmentation, and potentiation. The addition of small amounts of Ca2+ or Ba2+ to the Ca2+-containing bathing solution, or the replacement of Ca2+ with Sr2+, led to a greater increase in the stimulation-induced increases in MEPP frequency. The Sr-induced increase in MEPP frequency was associated with an increase in the second component of facilitation of MEPP frequency; the Ba-induced increase with an increase in augmentation. These effects of Sr2+ and Ba2+ on stimulation-induced changes in MEPP frequency are similar to the effects of these ions on stimulation-induced changes in EPP amplitude. These ionic similarities and the similar kinetics of decay suggest that stimulation induced changes in MEPP frequency and EPP amplitude have some similar underlying mechanisms. Calculations are presented which show that a fourth power residual calcium model for stimulation-induced changes in transmitter release cannot readily account for the observation that stimulation-induced changes in MEPP frequency and EPP amplitude have similar time-courses.

Animals↗