Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

Separation of C19 and C21 dihydroxysteroids by open-hole tubular glass columns and lipophilic gel chromatography.

The combination of lipophilic gel chromatography and high-resolution glass capillary chromatography has been shown to be an important means of identification and quantification of steroid urinary metabolites. Some problems in the use of capillary columns, such as coating with polar and apolar stationary phases, column performance, thermal stability and injection systems have been investigated and this type of chromatography has been used in the analysis of 33 dihydroxysteroids. Gel chromatography is a method complementary to high-efficiency gas chromatography. The steroids are eluted according to the number of hydroxyl groups in the molecules.

Androstane-3,17-diol↗

Separation of tricyclic psychosedative drugs by high-speed ion-pair partition and liquid-solid adsorption chromatography.

The application of high-speed ion-pair partition and liquid-solid adsorption chromatography to the separation of twenty common tricyclic tranquilizers and antidepressant drugs is described. In the ion-pair system, amine-perchlorate ion-pairs were extracted from an aqueous stationary phase supported on 10-mum silica gel by organic eluents containing a chloromethane and a higher aliphatic alcohol, and chromatographic parameters for elution by eight eluent mixtures are presented. Using 5 mm times 120 mm columns good separations, according to chemical class, were achieved. For adsorption chromatography, the components were eluted from 20-mum spherical alumina using eluents containing methylene chloride, n-hexane or n-pentane, and acetic acid. Chromatographic parameters are given for eight eluent compositions. Components differing little in structure are well separated by liquid-solid adsorption chromatography. Compared with ion-pair partition chromatography, adsorption chromatography is much more selective for compounds of the same chemical type. The two methods are therefore complementary. Both methods gave plate heights in the range of 0.1 to 0.3 mm.

Adsorption↗

Derivatization and chromatography of nucleosides and nucleotides.

The aims of this study were to determine the effect of levels of various substances and reaction by-products, which are formed during hydrolysis of nucleic acids, on the derivatization and chromatography of nucleosides; and to investigate the silylation of mono- and dinucleotides. The effect of NaCl, KCl, MgCl2, NH4Cl, and (NH4)2SO4 on silylation and chromatography of nucleosides was studies at various molar excesses of salt. The response values for all nucleosides were studied at various molar excesses of salt. The response values for all nucleosides were significantly affected at molar excess salt present values (MSP) between 1 and 10 for KCl, NaCl, NH4Cl, (NH4)2SO4 and between 0.1 and 1 for MgCl2. It was noted that thymidine was more sensitive than other nucleosides if silylated in presence of these salts. Two chromatographic peaks at retention temperatures (RT) 240 and 251 were obtained for cytidine at MSP values of 10(-3) for NaCl, KCl, and MgCl2, and 10(-4) for NH4Cl and (NH4)2SO4. In a mixture of nucleosides the RT = 251 peak was used for quantitative analysis of cytidine as the RT = 240 peak elutes with guanosine. Thus, these salts have a significant effect on the gas-liquid chromatography of trimethylsilyl (TMS) cytidine in a mixture of nucleosides, especially the RT = 241 peak. The effect of salts on derivatization can be explained in part as follows: (a) reduced derivatization of nucleosides due to a decreased solubility in the solvent system; (b) formation of TMS anion derivatives, e.g. TMS-SO4, TMS-PO4, with a reduced molar excess of BSTFA; (c) metal chelation by Mg ions or other divalent cations with nucleosides or BSTFA; and/or (d) an increased breakdown of TMS derivatives in presence of salt in the sample or on the top 3 in. of the column packing. Also, experiments were made on the effect of other substances such as Tris, phosphate, alkaline phosphatase, and KCl on completeness of silylation. The individual impurities showed no significant effect on the relative weight response (RWR) values of nucleosides; however, when a mixture was used, significantly lower RWR values were observed for all nucleosides except thymidine when using 1000 molar excess of BSTFA greater than 1000 should be used for silylation and chromatography of nucleosides in an RNA hydrolysate. As reported earlier the best derivatization of nucleosides was achieved using closed tube silylation at 150 degrees for 15 min with 225 molar excess BSTFA and chromatography on 4% OV-11 on Supelcoport. In general, the presence of salts and other substances can be significant in quantitative work, thus it is suggested that they be removed using chromatographic cleanup methods. The stability of nucleosides as a function of concentration of HCl, at room temperature was studied and very low RWR values for nucleosides were obtained when stored for 48 h in greater than 0.001 N HCl. Trimethylsilylation of various nucleotides and dinucleotides were made at 15 min as a function of temperature, and at 150 degrees at different times...

Chromatography, Gas↗

Tandem separation schemes for preparative high-performance liquid chromatography of proteins.

Preparative chromatography of protein mixtures was carried out by tandem separation schemes involving frontal chromatography followed by stepwise desorption or displacement. In this way, with columns and instruments generally employed in analytical high-performance liquid chromatography, proteins could be purified in quantities similar to those typically separated by a preparative-scale system. A mixture of beta-lactoglobulin A and B was loaded onto an anion-exchange column, and, in the process, a large fraction of the less-retained beta-lactoglobulin B was recovered in pure form. The column was then flushed with the carrier, and subsequent desorption of the substances bound on the stationary phase was carried out by single-step desorption, two-step desorption, or displacement. With this mixture, the last two methods yielded approximately the same results in terms of the amount of product obtained per unit column volume. Whereas stepwise desorption is a simpler technique than displacement, the latter is required for the separation of components having similar adsorption behavior. In another set of experiments, a protein mixture obtained by heat treatment of human growth hormone was fractionated on a reversed-phase column. After loading the column by frontal chromatography, which separated a large fraction of the main product from the other components retained by the column, four desorption steps were applied to recover the individual components. These separation schemes offer an approach to preparative chromatography of proteins that is superior to conventional linear elution in terms of column load capacity, low mobile phase consumption, simultaneous separation and concentration, as well as enrichment of trace components.

Chromatography, High Pressure Liquid↗

High-capacity cation-exchange column for enhanced resolution of adjacent peaks of cations in ion chromatography.

One of the advantages of ion chromatography [Anal Chem. 47 (1975) 1801] as compared to other analytical techniques is that several ions may be analyzed simultaneously. One of the most important contributions of cation-exchange chromatography is its sensitivity to ammonium ion, which is difficult to analyze by other techniques [J. Weiss, in: E.L. Johnson (Ed.), Handbook of Ion Chromatography, Dionex, Sunnyvale, CA, USA]. The determination of low concentrations of ammonium ion in the presence of high concentrations of sodium poses a challenge in cation-exchange chromatography [J. Weiss, Ion Chromatography, VCH, 2nd Edition, Weinheim, 1995], as both cations have similar selectivities for the common stationary phases containing either sulfonate or carboxylate functional groups. The task was to develop a new cation-exchange stationary phase (for diverse concentration ratios of adjacent peaks) to overcome limitations experienced in previous trails. Various cation-exchange capacities and column body formats were investigated to optimize this application and others. The advantages and disadvantages of two carboxylic acid columns of different cation-exchange capacities and different column formats will be discussed.

Amines↗

On-line coupling of micro-enzyme reactor with micro-membrane chromatography for protein digestion, peptide separation, and protein identification using electrospray ionization mass spectrometry.

To miniaturize high-performance membrane chromatography, a poly(vinylidene fluoride) membrane medium, employed as the stationary phase, is sandwiched between two poly(dimethylsiloxane) substrates containing the microchannels. The microchannels are fabricated by the capillary molding technique, involving the use of capillaries as the channel template and the fluid inlet/outlet. The micro(micro)-membrane chromatography system is coupled with a micro-enzyme reactor containing immobilized trypsins for performing rapid protein digestion, peptide separation, and protein identification using electrospray ionization mass spectrometry. Separation performance of cytochrome c digest in micro-membrane chromatography is compared with the results obtained from a regular reversed-phase micro-liquid chromatography. The efficacy and the potentials of micro-membrane chromatography in tryptic mapping are reported. On-line integration of the micro-enzyme reactor with micro-chromatographic separation techniques and electrospray ionization mass spectrometry clearly provides a microanalytical platform for automated sample handling, minimized sample loss, and reduced sample consumption. It also provides enhanced detection sensitivity and dynamic range for the analysis of complex protein mixtures such as cell lysates in proteomics research.

Amino Acid Sequence↗

Techniques for gas chromatography of volatile terpenoids from a range of matrices.

The commercial importance of the volatile mono- and sesqui-terpenoids has resulted in a wide range of techiques being used for extraction, concentration, chromatography, and characterisation of constituents. The major chromatographic technique is gas chromatography, and tandem techniques of chromatography linked to further chromatography and spectroscopy, allow much increased resolution, and greater ease of characterisation of terpenes. A wide range of extraction techniques are discussed, and suitability for particular matrices and sample sizes outlined. Chromatography operating conditions and stationary phases, and techniques for solute identification are laid out. A number of applications of terpene analysis in many different matrices are discussed.

Chromatography, Gas↗

Studies on steroids. CCXXIX. Separation and characterization of catechol oestrogen glucuronides in urine of pregnant women by high-performance liquid chromatography.

The separation and characterization of catechol oestrogen glucuronides in the urine of pregnant women by high-performance liquid chromatography with electrochemical detection is described. The urine samples from pregnant women were passed through Amberlite XAD-2 and Sep-Pak C18 columns and subsequented to ion-exchange chromatography on piperidinohydroxypropyl Sephadex LH-20 to isolate the oestrogen glucuronide fraction. The subsequent resolution into individual oestrogen glucuronides was achieved by high-performance liquid chromatography on a reversed-phase column. 2-Hydroxyoestrone 2-glucuronide and 4-hydroxyoestrone 4-glucuronide were identified on the basis of their behaviour in high-performance liquid chromatography with three different mobile phases. Derivatization of two glucuronides with 2-ferrocenylethylamine, followed by chromatographic separation and measurement of hydrodynamic voltammograms with an electrochemical detector was carried out for unequivocal identification. Enzymatic cleavage of the glucuronoside linkage followed by the identification of deconjugated catechol oestrogens by high-performance liquid chromatography with electrochemical detection further supported the structural assignment of these metabolites. The ratio between the amounts of 2-hydroxyoestrone 2-glucuronide and 4-hydroxyoestrone 4-glucuronide excreted in the urine of pregnant women was found to be ca. 5:1.

Chromatography, High Pressure Liquid↗

Trace detection of modified DNA bases via moving-belt liquid chromatography-mass spectrometry using electrophoric derivatization and negative chemical ionization.

Electrophoric derivatives of 5-methylcytosine and 5-hydroxymethyluracil nucleobases are determined using high-performance liquid chromatography-mass spectrometry coupled via a moving-belt interface. Standards as well as samples derived from DNA are analysed. As little as 9.9 pg (signal-to-noise ratio 5) and 180 fg (signal-to-noise ratio 10) of the respective nucleobases are detected in the electron-capture negative chemical ionization mode, and linear responses are observed over a moderate dynamic range. In a comparison study, liquid chromatography-electron-capture negative chemical ionization mass spectrometry is found to have a sensitivity comparable to gas chromatography-electron-capture negative chemical ionization mass spectrometry for 5-hydroxymethyluracil. A detection limit of 60 fg (signal-to-noise ratio 5) by gas chromatography-mass spectrometry is only three-fold better than the amount detected by liquid chromatography-mass spectrometry using the same mass spectrometer.

5-Methylcytosine↗

(Micellar) electrokinetic chromatography: an interesting solution for the liquid phase separation dilemma.

High-performance liquid chromatography (HPLC) is a well-established method in modern analysis. The method is simple, very robust and is applicable to the majority of components to be analyzed in contrast to gas chromatography. Low efficiency and small peak capacity are sore points of HPLC when complex mixtures have to be separated. The reason for this dilemma is the small diffusion coefficient of the analytes in the liquid mobile phase compared to a gaseous phase. This review, complemented by exemplary calculated data and some latest results of our own research, illustrates the dilemma of liquid phase chromatography to achieve high efficiencies under reasonable conditions. It is shown that (micellar) electrokinetic chromatography, offering fast and efficient separations, is a very promising solution for this dilemma. Additional features of this method are possibilities of on-line analyte concentration, coupling to mass spectrometry and the easy change of selectivities by applying various separation additives. The pros and cons of electrokinetic chromatography are pointed out and some application examples are given.

Chromatography, Micellar Electrokinetic Capillary↗

Comparing the optimum performance of the different modes of preparative liquid chromatography.

A comparative study of the optimization of the different modes of the preparative separation of binary mixtures by liquid chromatography is presented. Band profiles were calculated by means of the equilibrium-dispersive model of chromatography in the cases of isocratic elution, gradient elution, and displacement chromatography. The objective function to be maximized was the product of the production rate and the recovery yield. The production rate was calculated using the same definition of the cycle time in all cases. This common definition accounts for column regeneration after each run in each mode of the separation. The calculations reveal that the number of experimental parameters to be adjusted to achieve optimum separations is relatively small. The major parameters are the loading factor and the number of theoretical plates, besides the displacer concentration in displacement chromatography, or the gradient steepness in gradient elution. The relative advantages of the different modes of preparative chromatography are discussed.

Chromatography, Liquid↗

Transcription factor-green fluorescent protein chimeric fusion proteins and their use in studies of DNA affinity chromatography.

A new plasmid, pJ22, was produced by introducing the enhanced green fluorescent protein (GFP) coding sequence into the pET28 plasmid while retaining much of the multiple cloning site. This new plasmid was then used to produce a chimeric fusion protein containing the DNA-binding region of the rat liver CAAT enhancer binding protein (C/EBP) fused to the COOH-terminus of GFP. This new GFP-C/EBP fusion protein also contains (His)6 to facilitate purification by Ni(2+)-agarose and several other useful features. The plasmid and protein were developed to allow us to more rapidly investigate the DNA-Sepharose affinity chromatography of transcription factors. The GFP-C/EBP protein is virtually identical in its DNA-binding properties to a well-characterized, bacterially expressed protein called C/EBP 62 which has been shown to mimic rat wild-type C/EBP DNA-binding. GFP-C/EBP also binds to DNA-Sepharose which contains the CAAT element and is eluted by a salt gradient. Salt-dependent elution was highly temperature-dependent over the range of 4-19 degrees C. Since temperature-dependent DNA-binding has also been reported for other DNA-binding proteins, this may also occur with other transcription factors. DNA-affinity chromatography gave higher purity than that obtained by Ni(2+)-agarose chromatography and chromatography on the same DNA-Sepharose column at two different temperatures resulted in the greatest purification, to near homogeneity. This temperature-dependent affinity chromatography provides an important new approach to transcription factor purification.

Amino Acid Sequence↗

Use of compact, porous units with immobilized ligands with high molecular masses in affinity chromatography and enzymatic conversion of substrates with high and low molecular masses.

Different ligands with high molecular masses are immobilized on compact, porous separation units and used for affinity chromatography. In subsequent experiments different enzymes are immobilized and used for converting substrates with low and high molecular masses. Disk or tube with immobilized concanavalin A (ConA) are used as model systems for lectin affinity chromatography. The enzyme glucose oxidase is used as a standard protein to test the ConA units. Subsequently glycoproteins from plasma membranes of rat liver are separated, using units with immobilized ConA. The enzyme dipeptidyl peptidase i.v., which is used as a model protein in the experiments, is enriched about 40-fold in a single step, with a yield of over 90%. The results are only slightly better than those obtained with ConA when it is immobilized on bulk supports. The important improvement lies in the reduction of separation time to only 1 h. Experiments concerning the isolation of monoclonal antibodies against clotting factor VIII (FVIII) are carried out on disks, combining anion-exchange chromatography and protein A affinity chromatography as a model for multidimensional chromatography. Both IgG (bound to the protein A disk) and accompanying proteins (bound to the anion-exchange disk) from mouse ascites fluid are retarded and eluted separately. With the immobilized enzymes invertase and glucose oxidase (GOX) the corresponding substrates with low molecular masses, saccharose and glucose, are converted. It is shown that the amount of immobilized enzyme and the concentration of the substrate are responsible for the extent of the conversion, whereas the flow-rates used in the experiments have no effect at all. The influence of immobilization chemistry was investigated with GOX. Indirect immobilization with ConA as spacer proved to be the best alternative. With trypsin, immobilized on a disk, substrates with high molecular masses are digested in flow-through. For optimal digestion the proteins have to be denatured in the buffer for sodium dodecyl sulfate-polyacrlyamide gel electrophoresis prior to application. In contrast to the conversion of substrates with low molecular masses, flow-rates play an important part in conversion of substrates with high molecular masses. With lower flow-rates a higher degree of digestion is achieved.

Animals↗

Planar chromatography at the turn of the century.

An overview of the state-of-the-art of modern thin-layer chromatography (planar chromatography) is presented with emphasis on the complementary features of thin-layer and column liquid chromatographic separations. The reasons for selecting thin-layer chromatography for a particular analysis are identified by its attributes: a disposable stationary phase; simultaneous parallel separations; static detection free of time constraints; storage device for chromatographic information; all sample components are observed in the chromatogram. Future prospects for improved separation performance in TLC using zone refocusing, forced flow and electroosmotic flow methods are discussed as well as increasing zone capacity by using two-dimensional development and coupling to column chromatographic methods. Advances in coupling thin-layer chromatography with spectroscopic methods for structural elucidation are also considered. Finally, some predictions are made for how thin-layer chromatography will be practiced in the future.

Chromatography, Thin Layer↗

Analysis and purification of nucleic acids by ion-pair reversed-phase high-performance liquid chromatography.

Sizing of DNA fragments is a routine analysis traditionally performed on agarose or polyacrylamide gels. Electrophoretic analysis is labor-intensive with only limited potential for automation. Recovery of DNA fragments from gels is cumbersome. We present data on automated, size-based separation of DNA fragments by ion-pair reversed-phase high performance liquid chromatography (IP RP HPLC) - DNA chromatography - on the WAVE DNA Fragment Analysis System with the DNASep cartridge. This system is suitable for accurate and rapid sizing of double-stranded (ds) DNA fragments from 50 to ca. 2000 base pairs (bp). Fluorescently labeled DNA fragments are compatible with the technology. Length-dependent separation of dsDNA fragments is sequence independent and retention times are highly reproducible. The resolving capabilities of DNA chromatography are illustrated by the analysis of multiple DNA size markers. Resolved dsDNA fragments are easily collected and are suitable for downstream applications such as sequencing and cloning. DNA chromatography under denaturing conditions with fluorescently labeled DNA fragments offers a means for the separation and purification of individual strands of dsDNA. Analysis of DNA fragments on the WAVE System is highly automated and requires minimal manual intervention. DNA chromatography offers a reliable and automated alternative to gel electrophoresis for the analysis of DNA fragments.

Automation↗

Quantitative affinity chromatography.

The objective of this review is to summarize developments in the use of quantitative affinity chromatography to determine equilibrium constants for solute interactions of biological interest. Affinity chromatography is an extremely versatile method for characterizing interactions between dissimilar reactants because the biospecificity incorporated into the design of the affinity matrix ensures applicability of the method regardless of the relative sizes of the two reacting solutes. Adoption of different experimental strategies, such as column chromatography, simple partition equilibrium experiments, solid-phase immunoassay, and biosensor technology, has led to a situation whereby affinity chromatography affords a means of characterizing interactions governed by an extremely broad range of binding affinities--relatively weak interactions (binding constants below 10(3) M(-1)) through to interactions with binding constants in excess of 10(9) M(-1). In addition to its important role in solute separation and purification, affinity chromatography thus also possesses considerable potential for investigating the functional roles of the reactants thereby purified.

Biosensing Techniques↗

Mathematical analysis of frontal affinity chromatography in particle and membrane configurations.

The scaleup and optimization of large-scale affinity-chromatographic operations in the recovery, separation and purification of biochemical components is of major industrial importance. The development of mathematical models to describe affinity-chromatographic processes, and the use of these models in computer programs to predict column performance is an engineering approach that can help to attain these bioprocess engineering tasks successfully. Most affinity-chromatographic separations are operated in the frontal mode, using fixed-bed columns. Purely diffusive and perfusion particles and membrane-based affinity chromatography are among the main commercially available technologies for these separations. For a particular application, a basic understanding of the main similarities and differences between particle and membrane frontal affinity chromatography and how these characteristics are reflected in the transport models is of fundamental relevance. This review presents the basic theoretical considerations used in the development of particle and membrane affinity chromatography models that can be applied in the design and operation of large-scale affinity separations in fixed-bed columns. A transport model for column affinity chromatography that considers column dispersion, particle internal convection, external film resistance, finite kinetic rate, plus macropore and micropore resistances is analyzed as a framework for exploring further the mathematical analysis. Such models provide a general realistic description of almost all practical systems. Specific mathematical models that take into account geometric considerations and transport effects have been developed for both particle and membrane affinity chromatography systems. Some of the most common simplified models, based on linear driving-force (LDF) and equilibrium assumptions, are emphasized. Analytical solutions of the corresponding simplified dimensionless affinity models are presented. Particular methods for estimating the parameters that characterize the mass-transfer and adsorption mechanisms in affinity systems are described.

Chromatography, Affinity↗

Affinity chromatography in the industrial purification of plasma proteins for therapeutic use.

Affinity chromatography is a powerful technique for the purification of many proteins in human plasma. Applications cover the isolation of proteins for research purposes but also, to a large extent, for the production of therapeutic products. In industrial plasma fractionation, affinity chromatography has been found to be particularly advantageous for fine and rapid capture of plasma proteins from industrial plasma fractions pre-purified by ethanol fractionation or by ion-exchange chromatography. To date, affinity chromatography is being used in the production of various licensed therapeutic plasma products, such as the concentrates of Factor VIII, Factor IX, von Willebrand Factor, Protein C, Antithrombin III, and Factor XI. Most commonly used ligands are heparin, gelatin, murine antibodies, and, to a lesser extent, Cu(2+). Possible development of the use of affinity chromatography in industrial plasma fractionation should be associated to the current development of phage display and combinatorial chemistry. Both approaches may lead to the development of tailor-made synthetic ligands that would allow implementation of protein capture technology, providing improved productivity and yield for plasma products.

Anticoagulants↗