Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

Influence of superstructure materials on strain around an implant under 2 loading conditions: a technical investigation.

PURPOSE: This investigation was concerned with the effect of 3 superstructure materials on the strain around an implant under static and nonimpact dynamic loading. MATERIALS AND METHODS: Five highly filled composite resin-veneered crown analogs, 5 autopolymerized acrylic resin-veneered crown analogs, and 5 gold-alloy full cast crown analogs were prepared. The resin veneers were applied to gold-alloy frameworks. These crown analogs were prepared to fit an ITI implant-abutment assembly, which was screwed into a block of acrylic resin to simulate implantation in bone. The crown analogs were successively placed on the abutment, and a lateral load of 100 N was applied to the superstructure by a lever-type testing machine. Strains were recorded under static and dynamic loading by a 2mm-long strain gauge bonded to the surface of the bone simulant tangential to the implant. The dynamic load simulated masticatory cycles (75 strokes/min). RESULTS: Although the strain values differed significantly between the static and dynamic loading (P < .05), there was no significant difference among the superstructure materials under either loading condition (P > .05). DISCUSSION: These findings are in agreement with in vivo measurements, thus suggesting that cyclic rather than impact loading should be used in the investigation of occlusal material behavior under functional loading. CONCLUSION: Under static and nonimpact dynamic loading, the 3 superstructure materials tested (highly filled composite resin, acrylic resin, and gold alloy) had the same influence on the strain transmitted to a bone simulant that surrounded a single implant.

Acrylic Resins↗

Cytotoxicity of hard chairside reline resins: effect of microwave irradiation and water bath postpolymerization treatments.

PURPOSE: To evaluate the influence of water bath and microwave postpolymerization treatments on the cytotoxicity of 6 hard reline acrylic resins. MATERIALS AND METHODS: The materials tested were Tokuso Rebase Fast (TR), Ufi Gel Hard (UGH), Duraliner II (D), Kooliner (K), New Truliner (NT), and Light Liner (LL). LL resin was additionally tested with an air-barrier coating (LLABC). Nine disks of each material (10 x 1 mm) were made and divided into 3 groups: group 1 (no postpolymerization treatment); group 2 (postpolymerization in microwave oven); group 3 (postpolymerization in water bath at 55 degrees C for 10 minutes). L929 cells were cultured in 96-well plates and incubated for 24 hours in Eagle's medium. Eluates prepared from the disks or medium without disks (control) replaced the medium. Cytotoxicity was assessed by both dehydrogenase succinic activity (MTT) assay and incorporation of radioactive 3H-thymidine assay. Tests were carried out in quadruplicate and repeated twice. Differences between groups were determined by analysis of variance with Tukey multiple-comparison intervals (alpha = .05). RESULTS: For MTT assay, the postpolymerization treatments had no effect on the cytotoxicity of all materials (P > .05). For 3H-thymidine assay, the postpolymerization treatments significantly decreased the cytotoxicity of UGH (P < .05). The cytotoxicity of K, NT, LL, and LLABC increased after microwave irradiation (P < .05). TR, NT, and LLABC showed an increase in cytotoxicity after water bath (P < .05). CONCLUSION: When assessed by MTT assay, the cytotoxicity of the materials was not affected by postpolymerization treatments. 3H-Thymidine assay showed that the cytotoxicity of the resins was not improved by the postpolymerization treatments, with the exception of UGH.

Acrylic Resins↗

Transfer copings made of a visible light-cured resin.

The treatment of complex fixed partial dentures and multiple-unit castings often requires intermediate procedures for the transfer of tooth relationships from the patient's mouth to the working model. Transfer copings used when multiple teeth have been prepared and the individual dies require accurate seating on the working cast. Transfer copings are commonly made of autopolymerizing acrylic resins. The use of these materials may present difficulty. A technique for making transfer copings by use of a visible light-cured resin is presented.

Acrylic Resins↗

Treatment of temporomandibular joint dysfunction with a visible light-cured resin overlay denture: a case report.

A woman presented with temporomandibular dysfunction caused by a marked overclosure of her mandible. She complained of pain and clicking noises in her temporomandibular joint. After initial assessment and treatment with a provisional occlusal acrylic resin splint, the patient was provided with a definitive overlay denture with visible light-cured resin as occlusal overlays. The denture was stable in the mouth and the occlusal resin material showed some occlusal wear at the 2-year examination.

Acrylic Resins↗

Shear bond strength of several new core materials.

This study compared the shear bond strengths of three core materials: a light activated glass-ionomer cement (VariGlass VLC), a fluoride-release dual cure composite resin (Fluoro Core), and a conventional silver-reinforced glass-ionomer cement (Miracle Mix) when cured to dentin. Fifty-four noncarious molar teeth were extracted, cleaned, mounted in acrylic resin, and sectioned horizontally to expose the dentin surface. Each material was mixed according to manufacturer's instructions, applied in a premade mold to the exposed dentin, and then cured. The specimens were randomized into three group (six teeth from each material) and stored (37 degrees C, 100% humidity) for 15 minutes, 24 hours, and 24 hours and were then thermocycled (5 degrees to 55 degrees C) for 125 cycles. The specimens were tested for shear bond strength with the Instron universal testing machine. The differences among time groups were not statistically significant except for Miracle Mix and VariGlass VLC cements, which showed a greater improvement with thermocycling. This study indicated that the FluoroCore resin exhibited the greatest shear bond strength of the core materials and that VariGlass VLC cement had greater bond strength than Miracle Mix cement except after thermocycling, when VariGlass VLC cement and FluoroCore resin were not significantly different.

Acrylic Resins↗

Wear of composite resin in vitro: a testing machine with rubber plate. Preliminary results.

A new machine was developed to study the wear of dental filling materials in vitro. Four products: amalgam, Adaptic, Clearfil and acrylic resin were tested. Wear was measured quantitatively by weighing the specimen, and the wear pattern was studied qualitatively with a scanning electron microscope (SEM). A comparison was made with materials that were placed in the mouth for a prolonged period. It was found that the in vitro wear pattern was comparable to that found in vivo.

Acrylic Resins↗

Tensile bond strengths of hard chairside reline resins as influenced by water storage.

Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550(R)) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550(R) denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II(R) reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II(R) reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner(R) material. Both hard chairside reline materials failed adhesively across Lucitone 550(R) denture base resin, in both periods of time.

Acrylic Resins↗

Repairability of polyacid-modified composite resin.

The purpose of this study was to evaluate the effect of time and surface treatment on the resulting shear bond strength of a repaired polyacid-modified composite resin restorative material (VariGlass VLC). Seventy-two specimens of VariGlass were prepared in cavities (2 mm X 7 mm) cut into acrylic resin cylinders. The specimens were then divided into three groups of 24. For each of the three groups, 12 of the specimens were repaired 5 minutes after the cavities were initially filled, while 12 specimens were repaired 1 week after the initial fill. The VariGlass surfaces were treated in one of the following ways: no treatment; primer (30 seconds) and adhesive (light activated for 10 seconds); or 37% phosphoric acid etchant (30 seconds), primer (30 seconds), and adhesive (light activated for 10 seconds). Repairs were made using a split polytetrafluoroethylene mold (3 mm X 5 mm) mounted over the exposed VariGlass surface. After bonding a cylinder of VariGlass to the treated surfaces, the specimens were thermocycled 500 times (5 degrees C and 55 degrees C water baths), stored in distilled water for 1 week, and loaded to failure in shear at 0.5 mm/min. Data were analyzed using two-way ANOVA and a Student-Newman-Keuls multiple comparison test. Results indicated that the bond strength of specimens repaired at 5 minutes was significantly higher when no surface treatment was used prior to repair. Bond strength of specimens repaired at 1 week was unaffected by surface treatment. Time of repair significantly affected the no-treatment and the primer-adhesive groups.

Acrylic Resins↗

Porosity of resin veneer materials.

The present investigation has studied the effects of different types of resins and different processing and curing methods on the number and size of pores occurring in resin facing materials. The mean number of pores per square millimeter varied between 0.5 and 4. The highest numbers occurred in unfilled heat-polymerized acrylic resin and in light-activated resin, whereas the lowest numbers were found in heat-polymerized micro-filled resin. Specimens processed in accordance with the free technique and cured under pressure consistently obtained lower numbers of pores than the corresponding specimens processed in a flask. Most of the pores were less than 50 micron diameter in all test groups. From a clinical point of view, a dense resin with a limited content of pores may give the most favorable results in terms of mechanical, esthetic, and hygienic properties of the veneer.

Acrylic Resins↗

Combined obturator and palatal-lift prosthesis: a case report.

A technique for the fabrication of a combined obturator and palatal-lift prosthesis is presented. The metal framework embodied the principles of partial denture design. A sequence of steps was used to achieve an accurate representation of the pharyngeal tissues, on which the pharyngeal extension was constructed. This extension was fabricated in an autopolymerizing acrylic resin to avoid lengthy laboratory procedures.

Acrylic Resins↗

The effect of toothbrushing on a hybrid composite resin.

This study observed the effect of various toothpastes on a hybrid composite resin to determine the difference in surface roughness as measured by a profilometer. Slurries (100 gm dentifrice/100 gm H2O) of eight toothpastes were tested by brushing composite resin samples 20,000 times and recording changes in surface smoothness with a profile meter. The surface topography of a hybrid composite resin was altered by routine toothbrushing; the effect of Colgate toothpaste was a statistically smoother surface than found with the other dentifrices; and the surface topography of acrylic resin was altered less by Colgate, Crest, Viadent, and Supersmile than the more abrasive Shane, Sensodyne, Rembrandt, and Topol dentifrices.

Acrylic Resins↗

Fracture toughness of denture base acrylics.

Two types of fracture toughness specimen, the tapered cleavage (TC) and single edge notch (SEN), are compared. Their reproducibility, accuracy, and ease of preparation are investigated. The fracture toughness of four types of acrylic resin, heat cured, autopolymerized, injection molded, and high impact resistant, has been determined by one or both of the above methods. High impact acrylic proved too ductile for either of the specimens to be used to assesss K1c; however, these deviations from brittle behavior were revealed by the tests and some insight into impact resistance was gained. The SEN specimens proved capable of distinguishing between the fracture toughness characteristics of the four types of denture base acrylics and proved easy to fabricate. The TC specimens proved difficult to fabricate requiring specialized equipment; however, once made, the specimens revealed more of the fracture process than did the SEN specimens.

Acrylic Resins↗

Abrasion resistance of a resin-impregnated type IV gypsum in comparison to conventional products.

STATEMENT OF PROBLEM: Limited abrasion resistance is one of the disadvantages of gypsum materials. One means to improve these properties may be the addition of various polymers to reinforce surface and subsurface wear resistance. PURPOSE: The purpose of this study was to evaluate the abrasion resistance of 3 types of gypsum materials with a novel abrasion wear device. MATERIAL AND METHODS: A standard test specimen (50 x 50 x 8 mm) with repeating 1 mm, 45 degrees -angle vertical ridges was used as the test surface. Three types of gypsum materials were evaluated: a type III stone, a conventional type IV stone, and a resin-impregnated type IV stone. Specimens of each material (n = 30) were poured in a vinyl polysiloxane impression of the standard test specimen with the use of an acrylic resin custom tray. Each gypsum product was mixed according to the manufacturer's instructions, poured, and separated 1 hour later. Specimens were trimmed and allowed to bench set for 24 hours (n = 15) or 7 days (n = 15). Abrasion was evaluated with the use of a reciprocal moving stage positioned below a weighted stylus. The stylus was loaded with 3 different weights (15, 50, and 75 g), and the individual gypsum specimens were moved reciprocally for 10 passes. Before and after each set of passes, the specimen was measured on an analytical balance to determine material loss. Three-way ANOVA and Scheffe's multiple comparisons test were used to analyze the data (P<.05). RESULTS: Type III gypsum at 24 hours exhibited significantly greater material loss than type IV stones at both 7 days and 24 hours (P<.001). Type III gypsum specimens exhibited significantly greater material loss at 24 hours than at 7 days (P<.001). There was no significant difference in the abrasion resistance of type IV specimens at 24 hours and 7 days. CONCLUSION: Within the limitations of this study, no significant differences in abrasion resistance were found between specimens fabricated with resin-impregnated and conventional type IV stones, although the former exhibited the least material loss.

Acrylic Resins↗

Comparison of the midline stress fields in maxillary and mandibular complete dentures: a pilot study.

STATEMENT OF PROBLEM: Complete dentures typically fracture along the midline due to crack initiation and propagation from stressed areas. Therefore, it is important to characterize the magnitude and direction of maximum stresses developed in the midline of dentures. PURPOSE: The purpose of this pilot study was to determine the midline stress field of a mandibular complete denture under different loading conditions, and to compare this with the corresponding field of a maxillary denture to identify whether significant differences in maximum stresses between these 2 stress fields are responsible for the higher rate of failure seen clinically in maxillary dentures. MATERIAL AND METHODS: The identical casts used in this study were fabricated with commercial molds. Two complete acrylic resin dentures (1 maxillary and 1 mandibular) that were used in a previous study were selected as prototype dentures for this study. The mandibular acrylic denture was used to fabricate a 2-piece mold from silicone (upper half) and polymethyl methacrylate (PMMA) sheets (lower half) that was subsequently used to produce 3 identical mandibular complete dentures. The single maxillary acrylic denture was used to load the mandibular dentures. A rosette strain gauge was cemented onto the midline of each of the 3 mandibular dentures. The test conditions, including the fabrication of the casts used to induce loads, simulation of oral mucosa, loading procedure, strain measurement, and stress calculations, were identical to those used in a previous investigation of maxillary complete dentures to allow a direct comparison between maxillary and mandibular dentures. The Mann-Whitney test (alpha=.05) was used to quantify the differences in the stress magnitudes between maxillary and mandibular complete dentures. RESULTS: The stresses in the mandibular denture differed both qualitatively and quantitatively from those in the maxillary denture. The midline stress field of the mandibular complete denture was characterized by 2 low compressive principal stresses and a low maximum shear stress, whereas the corresponding stress field of the maxillary complete denture was characterized by a high principal tensile stress and a high shear stress. These differences between the stresses of maxillary and mandibular dentures were statistically significant (P<.001). CONCLUSION: The differences in stress patterns between mandibular and maxillary complete dentures as determined by this study, which also used data from a previous study, may be the primary reason why maxillary dentures fracture more often than mandibular dentures.

Acrylic Resins↗

Acrylic prosthesis of the fifth cervical vertebra in cervical chordoma. Case report and review of the literature.

Description of a two-stage surgical treatment of a case of chordoma of the fifth cervical vertebra mainly affecting the vertebral body. In the first stage the cervical column was immobilized employing a posterior approach and a small portion of the tumour in the right lamina was removed. In the second stage the whole of the body of C5 was removed by an anterior route and replaced with an acrylic prosthesis. The advantages of acrylic resin and the literature on vertebral prostheses are discussed.

Acrylic Resins↗

A radiographic assessment of progressive loading on bone around single osseointegrated implants in the posterior maxilla.

OBJECTIVES: The aim of this clinical study was to determine the effectiveness of progressive loading procedures on preserving crestal bone height and improving peri-implant bone density around maxillary implants restored with single premolar crowns by an accurate longitudinal radiographic assessment technique. MATERIALS AND METHODS: Twenty-three HA-coated, endosseous dental implants were placed in 20 subjects and permitted to heal for 5 months before surgical uncovering. The implants were randomly assigned to either an experimental or control group. Following a conventional healing period, the control group implants were restored with a metal ceramic crown and the experimental group implants underwent a progressive loading protocol. The experimental group was progressively loaded by increasing the height of the occlusal table in increments from a state of infraocclusion to full occlusion by adding acrylic resin to a heat-processed acrylic crown. The progressively loaded crowns were placed in infraocclusion for the first 2 months, light occlusion for the second 2 months, and full occlusion for the third 2 months. At this point, a metal ceramic crown replaced the acrylic crown. Standardized radiographs of each implant were made at the time of restoration, then after 2, 4, 6, 9, and 12 months of function. Digital image analysis and digital subtraction radiography were used to measure changes in crestal bone height and peri-implant bone density. RESULTS: The mean values of crestal bone height loss at 12 months were 0.2+/-0.27 mm for the progressively loaded implants and 0.59+/-0.27 for the conventionally loaded implants, and when tested with repeated-measure ANOVA across the time periods, the differences were statistically significant (P< or =0.05). The progressively loaded group showed a trend for higher bone density gain in the crestal area than the conventionally loaded group, but the conventionally loaded group showed a trend for higher bone density gain at the apex of the implants. CONCLUSION: The peri-implant bone around progressively loaded implants demonstrates less crestal bone loss than the bone around implants placed conventionally into full function. The peri-implant density measurements of the progressively loaded implants show continuous increase in peri-implant bone density by time.

Alveolar Process↗