Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SUTURE TECHNICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77Linked to original sources

Lasso repair of SLAP or Bankart lesions: a new arthroscopic technique.

Restoring the anatomic position and securing a torn superior labrum or Bankart lesion to its bony bed on the superior or anterior glenoid is the objective of surgical repair. The following technique describes a method that we have found to be effective, reproducible, and more time-efficient in affecting this goal. This technique allows the sutures to be passed through the soft tissue in a single step and, in addition, makes suture management easier before knot tying.

Arthroscopy↗

Arthroscopic rotator interval repair: the three-step all-inside technique.

Many clinical reports have emphasized the importance of rotator interval lesions in patients with glenohumeral instability, and many investigators have described open repair techniques, either as a supplement to other capsule reconstruction or as an isolated procedure. In this article, an original arthroscopic technique for rotator interval closure is described. This technique allows the operator to accurately manage the degree of tightening of the rotator interval, the knot tying, and the suture cutting, under direct intra-articular arthroscopic vision.

Arthroscopy↗

Modified technique for arthroscopic Bankart repair using anchor sutures.

Bankart repair, or one of its modifications, is currently the gold standard procedure for treatment of anterior traumatic shoulder instability. It is now possible to perform the operation arthroscopically with the introduction of suture anchors. As described by Eugene Wolf, arthroscopic shoulder stabilization using the Mitek (Mitek Surgical Products, Ethicon, Edinburgh, U.K.) anchors requires two anterior portals and intra-articular knot tying. However, sliding the anchor on the inside limb of a suture loop could be challenging because the other limb could get tangled in the nitinol arc of the anchor. We describe a modification of the original technique to prevent that possibility and avoid any tension on the repair tissue during anchor passage. The proposed modification involves the use of a cheap, readily available silastic feeding tube to isolate the outside limb of the suture loop and stabilize labral tissues while the anchor is being passed. This tube also serves as a stent for knot tying. By allowing the whole operation to be performed through one anterior portal, the modified technique reduces possible morbidity associated with a second portal and further reduces cost.

Arthroscopy↗

Superior labrum anterior posterior (SLAP) repair using the Neviaser portal.

Superior labrum anterior posterior (SLAP) repair using suture anchors requires successful passing of sutures through the labrum. The optimal angle for passing a penetrating suture retriever is perpendicular to the superior labrum. The Neviaser (superior-medial) portal, without a cannula, is ideally suited for this procedure. The authors demonstrate their technique and review the anatomy of this portal. The Neviaser portal is illustrated as an important working portal and not merely for inflow or outflow. The authors demonstrate that this is a safe and easy technique for SLAP repair.

Arthroscopy↗

Minimally invasive "crescentic" imbrication of the medial patellofemoral ligament for chronic patellar subluxation.

Chronic patellar subluxation is one of the many causes of anterior knee pain. Nonoperative management of this disorder is successful in many patients, but surgical intervention may be necessary for refractory cases. We present a surgical technique for chronic patellar subluxation that is minimally invasive and is focused specifically on the medial patellofemoral ligament.

Arthroscopy↗

Running suture for vesicourethral anastomosis in minilaparotomy radical retropubic prostatectomy.

INTRODUCTION: We used a running suture method for vesicourethral anastomosis in patients undergoing minilaparotomy radical retropubic prostatectomy. TECHNICAL CONSIDERATIONS: The vesicourethral anastomosis using a single knot at the 6:30-o'clock position is created with two steps of semicircular running suture. A total of 21 consecutive patients underwent this running suture method using the Endostitch in the hands of a single surgeon (T.M.) between March and November 2004. The running suture procedure was completed in 15 minutes on average. After surgery, no urinary leakage at the anastomotic site was found. Satisfactory continence was achieved in the short term in 100% (0 to 1 pad per day) of cases. However, dilation at the anastomosis using a metal dilator was required in 2 patients immediately after surgery. CONCLUSIONS: The running suture method is considered a feasible alternative in minilaparotomy radical retropubic prostatectomy.

Anastomosis, Surgical↗

Esophageal atresia: a simple technical detail aiding the mobilization and circular myotomy of the proximal segment.

A simple technical detail in placing the upper pouch holding suture to facilitate proximal segment mobilization in esophageal atresia is described. The suture is passed through both walls of the upper segment and the tip of the Foley catheter. If circular myotomy is needed, the Foley catheter balloon is inflated to fill the lumen of the upper pouch to facilitate dissection. This technique has been successfully used in 32 patients, eight with myotomy.

Esophageal Atresia↗

The Romano drill: a new surgical curved drill system.

A new surgical curved drill system that drills curved holes into bone is presented, along with several examples of its use in foot and ankle surgery. The technical information involving soft tissue fixation, wiring, or suturing around a bone bridge, by drilling a curved tunnel for tendon, capsule, and ligament reconstruction is also reviewed.

Ankle↗

A method for all-inside arthroscopic repair of Palmer 1B triangular fibrocartilage complex tears.

There have been different descriptions of arthroscopic repair of the Palmer 1B tear of the triangular fibrocartilage complex (TFCC). Both outside-in and inside-out techniques are in common use, but both have the disadvantage of an extra incision to tie the knots and they are time consuming. We present a technique for all-inside repair of Palmer 1B TFCC tears using a technique known from meniscal repair in the knee joint.

Arthroscopy↗

Pitfalls associated with FasT-Fix meniscal repair.

There are several devices currently available for all-inside meniscal repair. One of the newest of these devices, the FasT-Fix (Smith & Nephew, Endoscopic Division, Andover, MA), is attractive because it combines advantages of traditional inside-out meniscal repair with an all-inside technique. We chose to critically evaluate these devices in a cadaver model. FasT-Fix devices were inserted arthroscopically in 8 fresh-frozen cadaveric knees at 5 to 7 mm intervals. A total of 45 devices were placed (24 laterally, 21 medially), and the knees were subsequently dissected to determine the location of the inserted devices. Several potential pitfalls were identified during the evaluation. When using the depth penetration limiter that comes preset with the device (to a depth of 22 mm), superficial structures, including the iliotibial tract and even the skin, were at risk for penetration with the needle. The device could not effectively be inserted into the anterior meniscus or the extreme posterior horn. Other potential pitfalls seen during insertion of the FasT-Fix meniscal repair devices include suture tensioning issues (including failure of the suture during tightening), intra-articular deployment of the implants, premature deployment of both the first and second implants, difficulty in advancing the trigger for deployment of the second implant, and difficulty in placing vertical-mattress sutures. Although the FasT-Fix is already in clinical use, additional modifications would likely enhance meniscal repair using this device.

Arthroscopes↗

Use of vein-patch angioplasty in microvascular tissue transfers.

Vein-patch angioplasty is a well-established technique in vascular surgery to reduce the critical narrowing of the arteriotomy site. In microsurgical end-to-side anastomosis, although the arteriotomy is not closed, it is not known if anastomosis through a sclerotic segment contributes to narrowing at the anastomotic site. It is certainly technically difficult to perform a microanastomosis with fine sutures through a sclerotic segment. Two cases are illustrated in which vein-patch angioplasties were successfully used for microsurgical anastomoses.

Aged↗

Filter-protected carotid stenting via a minimal cervical access with transitory aspirated reversed flow during initial passage of the target lesion.

PURPOSE: To evaluate the preliminary results of filter-protected carotid artery stenting (CAS) via a minimal cervical access, with temporary common carotid artery (CCA) occlusion and aspiration in selected high-risk candidates for carotid endarterectomy. METHODS: Since February 2002, 26 patients (17 men; mean age 73.7 years, range 54-98) at high surgical risk according to the SAPPHIRE eligibility criteria underwent 29 transcervical CAS procedures under filter protection. Under general anesthesia, a 6-F short introducer sheath was directly mounted in the CCA through a small (2-4 cm) laterocervical cutdown. The CCA was briefly clamped, and blood was aspirated while the filter device was positioned above the target lesion. With the filter in place and the clamp released, nitinol stents were deployed under filter protection. Hemostasis was achieved by direct suture. RESULTS: Twenty-eight (96%) interventions were technically successful; 1 complex lesion could not be crossed and was converted to surgery. Mean clamping time was 1.7 (range 1.0-3.5) minutes. Combined 30-day stroke/mortality was 0%. Ultrasound surveillance demonstrated a < 60% asymptomatic in-stent restenosis in 1 (4%) patient with radiation-induced arteritis after 28 months. During a mean follow-up of 11.6 months (range 3-38), 1 (4%) minor ipsilateral stroke was noted at 6 months in a patient whose antiplatelet therapy was transitorily interrupted. CONCLUSION: Our preliminary observations from this small early experience suggest that this variant CAS technique is feasible and probably diminishes the neuroembolic risk during initial navigation of the ICA target stenosis.

Aged↗

[Treatment of complex hypospadias by the Snodgrass technique].

PURPOSE: Successful use of the Snodgrass modification of Tiersch-Duplay urethroplasty for repair of distal hypospadias has been reported. Given the features of the repair: technical simplicity, preservation of the urethral plate, single suture line in the urethroplasty and no need for vascularized pedicle graft, we felt that the technique could be applied to the treatment of proximal hypospadias. METHODS: A retrospective review of the records of 35 patients with either midshaft or penoscrotal hypospadias who underwent a Snodgrass type of hypospadias repair was carried out. Age at surgery was 3 to 54 months (mean age: 8.4 months). No patients with significant chordee were included. All patients had indwelling urethral stents for 5 to 7 days postoperatively. Follow-up ranged from 6 months to 3 years. RESULTS: There were no immediate postoperative complications. Four patients experienced a urethrocutaneous fistula in association with meatal stenosis. After meatal dilatation, 2 of these fistulae closed spontaneously for an overall fistula rate of 5.7%. The overall cosmetic result of the glans and urethral meatus was noted to be excellent. Urinary stream was normal in all cases. CONCLUSION: Our results indicate that the Snodgrass modification of Tiersch-Duplay hypospadias repair provides satisfactory cosmetic and functional results in the treatment of proximal hypospadias with a low surgical complication rate. In young patients, it is our procedure of choice for penile and penoscrotal hypospadias without major degrees of chordee.

Child, Preschool↗

Securing cochlear implants to the skull: two alternate methods.

In view of the various problems encountered with the traditional methods of securing cochlear implants--including dural tear and suture dissolution following infection--we devised two alternate methods of performing this procedure. We use a titanium mesh or a Gore-Tex patch secured with two 4-mm screws to fix the receiver to the skull. No patient who has undergone either of these procedures at our institution has experienced any of the complications that are associated with the older silk, nylon, and Dacron sutures. Moreover, our two alternate methods are less technically difficult and can be performed in a shorter period of time.

Cochlear Implantation↗

Total laparoscopic abdominal aortic aneurysms repair.

AIM: The aim of the study was to describe our experience of total laparoscopic abdominal aortic aneurysm (AAA) repair. METHODS: Between February 2002 and September 2004, we performed 49 total laparoscopic AAA repair in 45 men and 4 women. Median age was 73 years (range, 46-85 years). Median aneurysm size was 52 mm (range, 30-95 mm). ASA class of patients was II, III and IV in 16, 32 and 1 cases, respectively. We used the laparoscopic transperitoneal left retrocolic approach in 47 patients. Seven patients were operated via a tranperitoneal left retrorenal approach and one patient via a retroperitoneoscopic approach. RESULTS: We implanted tube grafts and bifurcated grafts in 19 and 30 patients, respectively. Median operative time was 290 min (range, 160-420 min). Median clamping time was 81.5 min (range, 35-230 min). Median blood loss was 1800 cc (range, 300-6900 cc). Mortality was 6.1% (3 patients). In our early experience, two patients died of myocardial infarction. The 3rd death was due to a multiple organ failure. Thirteen major non lethal postoperative complications were observed in 9 patients (18%). Four patients had local/vascular complications, which required reintervention (8%). Nasogastric tube is now removed at the end of procedure. Median duration of ileus, return to general diet, ambulation and hospital stay were 2, 3, 3 and 10 days. With a median follow-up of 19 months (range, 8-39 months), complete recovery with patent graft was observed in 44 patients. Two patients needed a crossover femoral graft for one iliac dissection and one graft limb occlusion. CONCLUSIONS: These results show that total laparoscopic AAA repair is feasible and worthwhile for patients once the learning curve is overcome. It remains technically demanding and a previous training in videoscopic sutures is essential. Initial learning curve in laparoscopic aortic surgery with aortoiliac occlusive lesions is preferable before to begin laparoscopic AAA repair.

Aged↗

[Can resorbable suture material be used in surgery of the supra-aortic branches?].

The experience with the use of monofilament absorbable suture (5/0 USP) in supraaortal vessels shows the same results related to neurological complication. The postoperative technical complications (bleeding, occlusion, restenosis) could be significantly reduced (p less than or equal to 0.05). Suture ruptures of aneurysms were not observed after resorbable vascular suture. The resorbable monofilament suture material is useful in high pressure vessel system.

Blood Vessel Prosthesis↗

[Section of the pancreas in left-side pancreatectomy and cephalic duodenopancreatectomy. Two technical details (author's transl)].

An oblique section of the pancreatic isthmus, directed internally and posteriorly, facilitates anastomosis between the pancreatic stump and the jejunal loop in cephalic duodenopancreatectomy. In left-side pancreatectomy a bevelled section makde it possible for the pancreatic edge to fold in easily. Such technical details may contribute to easier and safer sutures after excision of pancreatic tissue.

Duodenum↗