Fracture toughness of steel-fiber-reinforced bone cement.

Fractures in the bone-cement mantle (polymethyl methacrylate) have been linked to the failure of cemented total joint prostheses. The heat generated by the curing bone cement has also been implicated in the necrosis of surrounding bone tissue, leading to loosening of the implants. The addition of reinforcements may improve the fracture properties of bone cement and decrease the peak temperatures during curing. This study investigates the changes in the fracture properties and the temperatures generated in the ASTM F451 tests by the addition of 316L stainless steel fibers to bone cement. The influence of filler volume fraction (5-15% by volume) and aspect ratios (19, 46, 57) on the fracture toughness of the acrylic bone cement was assessed. Increasing the volume fraction of the steel fibers resulted in significant increases in the fracture toughness of the steel-fiber-reinforced composite. Fracture-toughness increases of up to 2.63 times the control values were obtained with the use of steel-fiber reinforcements. No clear trend in the fracture toughness was discerned for increasing aspect ratios of the reinforcements. There is a decrease in the peak temperatures reached during the curing of the steel-fiber-reinforced bone cement, though the decrease is too small to be clinically relevant. Large increases in the fatigue life of acrylic bone cement were also obtained by the addition of steel fibers. These results indicate that the use of steel fibers may enhance the durability of cemented joint prostheses.

Biocompatible Materials↗

The role of macrophages and giant cells in loosening of joint replacement.

Macrophages and foreign-body giant cells from the bone-cement interface of loosened joint replacement were assayed for direct bone resorption in an in vitro experimental model. Human osteoclasts from giant cell tumors and experimental animal osteoclasts were not capable of resorbing the bone under experimental conditions, but osteoclasts are. It is suggested that macrophages and giant cells in loosened implants may initiate bone resorption, removing the extra-cellular barrier that normally protects mineral crystals from osteoclastic recognition.

Aged↗

Effect of loading rate on bond strength.

The purpose of this study was to examine the effect of loading rate on the bond strength of brackets bonded to enamel. Forty premolars were used and brackets were bonded with a chemically cured or a light-cured adhesive, mounted on a testing machine, and debonded under shear stress at two loading velocities: a standard 1 mm/min, and a fast 200 mm/min which better approximates the actual jaw velocity during chewing. Bond strength results (N) were analyzed with two-way analysis of variance (loading rate, adhesive) (alpha = 0.05). An increased loading rate resulted in decreased bond strength, probably due to the induction of a stiff body response and elimination of the viscoelastic properties of the resin. The results indicated a similar effect on both chemically cured and light-cured adhesives, thus emphasizing the need for standardized test conditions in bond strength protocols. The implication of loads generated during chewing must be considered when estimating the long-term survival of the bond.

Adhesiveness↗

Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation.

INTRODUCTION: Improving the longevity and reliability of cemented total knee arthroplasty (TKA) remains a major step to achieve. It is still unclear, whether a cemented tibial stem reduces micromotion of the tibial tray and produces therefore a better initial stability or not. The higher conformity of rotating platform design and the possible rotary forces to the tibial platform may produce higher micromotion when the tibial stem remains cementless (hybrid fixation). MATERIALS AND METHODS: An in vitro study was performed using the PFC mobile bearing tibial tray (DePuy, Warswa, IN, USA) to test the hypothesis that the addition of cement surrounding the tibial stem reduces micromotion of the tibial tray in cemented TKA with mobile bearing design. Ten tibial trays with mobile design were implanted in sawbones with a 3-mm cement mantle beneath the baseplate of the tibial tray and with or without the cemented stem. Tibial trays were loaded additionally in the ventral, lateral, medial and posterior positions with 2,500 N using the Zwick Z010 instrumentation and HBM pick up Hottinger Baldwin. RESULTS: In this study, a significant increased mean maximum liftoff was found when only cementing the tibial baseplate (hybrid fixation), compared to the fully cemented tibial tray (P<0.02). CONCLUSION: In conclusion, the stem of mobile bearing tibial components should be cemented to provide increased micromotion and earlier loosening.

Arthroplasty, Replacement, Knee↗

Wear of crosslinked polyethylene under different tribological conditions.

Ultra high molecular weight polyethylene (UHMWPE) wear debris has been shown to be a major cause of long term failure of total joint replacements. Recently, crosslinking has been extensively introduced to reduce the wear of UHMWPE. In this study the wear of non-crosslinked and crosslinked UHMWPE were compared under a range of conditions. The materials examined were UHMWPE GUR 1050, non-crosslinked, moderately crosslinked--5MRad, and highly crosslinked--10MRad. The wear was examined on a multidirectional pin on plate rig. The effect of counterface roughness on wear under different kinematics was examined. The results from the different counterface conditions showed that highly crosslinked UHMWPE had significantly lower wear against both smooth and scratched counterfaces. However the reduction in wear for crosslinked polyethylene was less for scratched counterfaces. The second part of the study showed that all the UHMWPE's produced lower wear rates under lower multidirectionality because of reduced cross shear frictional forces and work. These findings are relevant to the consideration of the use of crosslinked polyethylene in the knee, where the kinematics have lower levels of cross shear and in the hip and knee against roughened metallic counterfaces.

Biomechanical Phenomena↗

Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation.

Alloys based on Ni-Ti intermetallics generally exhibit special shape memory and pseudoelastic properties, which make them desirable for use in the dental field as orthodontic wires. The possibility of nickel release from these materials is of high concern, because the allergenicity of this element. The aim of this study was to test pseudoelastic Ni-Ti wires in simulated physiological conditions, investigating the combined effect of strain and fluoridated media: the wires were examined both under strained (5% tensile strain) and unstrained conditions, in fluoridated artificial saliva at 37 degrees C. Real time electrochemical nickel release testing was performed using a novel application of a radiotracer based method, thin layer activation (TLA). TLA was validated, in unstrained conditions, against adsorptive stripping voltammetry methodology. Control tests were also performed in non-fluoridated artificial saliva. From our research it transpired that the corrosion behaviour of Ni-Ti alloy is highly affected by the fluoride content, showing a release of 4.79+/-0.10 microg/cm2/day, but, differently from other biomaterials, it does not seem to be affected by elastic tensile strain. The application of the TLA method in the biomedical field appears a suitable technique to monitor in real time the corrosion behaviour of biomedical devices.

Biomimetic Materials↗

Role of silicon contamination on calcification of hydrophilic acrylic intraocular lenses.

PURPOSE: To verify the presence of the element silicon on hydrophilic acrylic intraocular lenses (IOLs) explanted because of calcification. DESIGN: Interventional case series with clinicopathological correlation. METHODS: Twenty explanted IOLs with surface deposits (MemoryLens), and 20 with deposits mostly within their optic substance (SC60B-OUV and Aqua-Sense; 10 each) were used. After gross, microscopic, and histochemical analyses to confirm the presence of deposits, the lenses underwent scanning electron microscopy (SEM) with energy dispersive x-ray spectroscopy (EDS) for elemental composition, on the external surface of MemoryLens IOLs, and on the surface and internal substance of SC60B-OUV and Aqua-Sense IOLs. The weight percentage of the element silicon was obtained at the level of deposits, and at adjacent deposit-free areas in all lenses. RESULTS: Scanning electron microscopy (SEM) coupled with EDS confirmed that the composition of the deposits was calcium/phosphate in all cases. The element silicon was found in all 40 lenses, on all areas analyzed. The silicon weight percentage was higher at the level of the deposits. The presence of aluminum on five MemoryLens IOLs, and in most of the SC60B-OUV and Aqua-Sense lenses might be related to scattering from the aluminum mounting stubs used for surface analyses. CONCLUSIONS: Silicone compounds have been implicated in the calcification of another hydrophilic acrylic design (Hydroview). They may also have a role in the calcification of other hydrophilic acrylic IOLs. Further investigation on the relationship between the presence of the element silicon and the silicone compounds found on calcified hydrophilic acrylic lenses is necessary.

Acrylic Resins↗

A 10-year comparison of explanted Hancock-II and Carpentier-Edwards supraannular bioprostheses.

BACKGROUND: Bioprosthetic heart valves are more frequently being used in valve replacement procedures today. Although second-generation bioprosthetic valves have improved functionality over their first-generation counterparts, they still often fail due to primary tissue degeneration. METHODS: This study examines two second-generation porcine valves after surgical explantation, the Hancock-II (HAN; Medtronic Heart Valve Division, Irvine, CA, USA) and the Carpentier-Edwards supraannular (CE-SAV; Baxter Healthcare Corporation, now Edwards LifeSciences, Irvine, CA, USA), with special attention to morphological/histological changes and reasons for valve failure. A total of 98 HAN and 65 CE-SAV valves were explanted and seen over a 10-year period. RESULTS: CE-SAV valves had a longer average implant duration than HAN valves (13.9+/-3.9 years vs. 10.0+/-5.1 years). Compared with HAN valves, CE-SAV valves also had a higher incidence of stent deformation (41.5% vs. 14.3%), calcification (75.4% vs. 54.1%), and pannus (100% vs. 91.8%). CONCLUSIONS: The greater degenerative changes seen with CE-SAV valves over HAN valves may be due to the longer implant duration of CE-SAV valves in this series. To our knowledge, the present study is the first direct morphological comparison of these two valve models.

Adult↗

A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures.

BACKGROUND: Periprosthetic femoral fractures with well-fixed femoral components can be difficult to manage and internal fixation is usually necessary. This study was designed to determine the effect of cable plate, strut allograft and combined plate and strut allograft fixations of periprosthetic femoral fractures. METHODS: A transverse fracture at the level of the tip of the femoral stem was simulated in six cadaveric femurs. The fracture was fixed with a plate-strut graft construct with and without proximal screws, a plate only construct with and without proximal screws and with both anterior and lateral struts grafts of 12 cm or 20 cm in length. The intact femur and the six constructs were tested using anteroposterior and axial loads to simulate the forces at the hip during gait. The interfragmentary motions were measured with an optoelectronic camera system. FINDINGS: The highest median interfragmentary translations were observed with the plate only construct without proximal screws. No significant differences in median translations were found between the combined plate-strut and the strut-graft alone constructs. Median interfragmentary rotations were largest with the plate only construct and lowest with the plate-strut constructs. INTERPRETATION: The best fracture fixation was achieved with the combined plate and strut graft constructs particularly in combination with the two unicortical screws above the fracture. The plate only constructs may not provide sufficient fixation stability in rotation for the simulated transverse fracture. The within-construct interfragmentary motions were not significantly different except for the plate only constructs. This suggests that the fixation construct type is the determining factor of interfragmentary motion.

Arthroplasty, Replacement, Hip↗

Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences.

Malalignment, in particular femoral component malrotation, is a commonly accepted failure mode in total knee arthroplasty. The general objective of this paper is twofold: firstly, it accentuates clinical observations of the effects of rotational malalignment in total knee arthroplasty. Secondly, it discusses the relevant parameters of existing knee joint models with regards to rotational malalignment and its biomechanical background, thereby setting a basis for future studies. To summarise, when modelling malalignment in total knee arthroplasty, the following aspects should be considered: Friction between the implant components, ligamentous and capsular structures, deformable body to model the PE inlay, and an in vivo validation of the model. Because of the large variance in anthropometrical data between individuals, future knee joint models should also incorporate individual data.

Animals↗

Problematic sites of third body embedment in polyethylene for total hip wear acceleration.

A computational model was developed to identify the sites of third body particle embedment in a total hip acetabular component surface that are most problematic in terms of roughening the overpassing regions of the femoral head counterface, leading in turn to most severely accelerated polyethylene wear. The analytical approach used was to calculate loci of acetabular sites that, during the gait cycle, overpass previously documented regions of kinetically most critical femoral head roughening. Instantaneous local contact stress and sliding distance were postulated as factors contributing to the severity of the femoral head scratching/roughening which would be expected, due to otherwise-similar particles embedded along each such acetabular overpass locus. The computational results showed that the location of debris embedment was a potent determinant of the amount of polyethylene wear acceleration expected. The data also showed that the supero-lateral aspect of the acetabular cup is consistently and by far the most problematic area for third body particle embedment.

Acetabulum↗

Primary stability of an anatomical cementless hip stem: a statistical analysis.

The primary stability that the surgeon can achieve during surgery is a determinant of the clinical success of cementless implants. Thus, estimating what level of primary stability can be obtained with a new design is an important aspect of pre-clinical evaluation. The primary stability of a cementless hip stem is not only affected by the implant design, but also by other factors such as the mechanical quality of the host bone, the presence of gaps around the bone-implant interface, the body weight of the patient, and the size of the implant. Even the most extensive experimental study can only explore a small sub-set of all possible combinations found in vivo. To overcome this limitation, we propose a combination of experimental and numerical methods. The primary stability of a cementless anatomical stem is assessed in vitro. A finite element model is developed to accurately replicate the same experiment. The model is then parameterised over the various factors that affect the primary stability, and used in a Monte Carlo scheme to assess the primary stability over a simulated population. In this study, the method was used to investigate the mechanical stability of an anatomical cementless stem over more than 1000 simulated cases. Twenty cases were found macroscopically unstable, due to a combination of unfavourable conditions. The rest of the Monte Carlo sample showed on average a peak micromotion under stair climbing loading of 206 +/- 159 microm. The proposed method can be used to evaluate new designs in conditions more representative of the variability in clinical practice.

Arthroplasty, Replacement, Hip↗

Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms.

BACKGROUND: Structural valve deterioration is the major cause of bioprosthetic valve failure. Because of the unique design features and anti-calcification treatment of the Freestyle (Medtronic Inc, Minneapolis, Minn) stentless bioprosthesis, development of structural valve deterioration may differ in comparison with other bioprosthetic valves. This study evaluates the mechanisms and clinical presentation of structural valve deterioration in the Freestyle stentless bioprosthesis. METHODS: Between January 1993 and August 2005, 608 patients underwent aortic valve replacement with a Freestyle stentless bioprosthesis. The implantation technique was subcoronary in 475 patients and a root replacement in 133 patients. Mean overall follow-up was 5.6 +/- 3.4 years. Follow-up was complete in all patients. Clinical and echocardiographic follow-ups were conducted prospectively. RESULTS: Freedom from structural valve deterioration was 95.8% at 10 years. Twelve patients showed evidence of structural valve deterioration and underwent reoperation for aortic regurgitation (n = 10) or aortic stenosis (n = 2). The mean age of patients with structural valve deterioration was significantly lower than patients without structural valve deterioration (62.6 +/- 8.2 years vs 68.6 +/- 8.3 years, P = .02). The median time between implantation and explantation was 8.7 years (range: 1.9-13.3 years). Eleven structural valve deteriorations occurred after subcoronary implantation, and 1 structural valve deterioration occurred after root implantation (P = .4). The mechanisms of structural valve deterioration were leaflet tears in 10 patients (6 in the left coronary cusp and 4 in the right coronary cusp), severe valve calcification in 1 patient, and cusp fibrosis in 1 patient. The interval between onset of symptoms and reoperation was acute or subacute in 10 patients. CONCLUSION: At 10 years, the Freestyle stentless bioprosthesis shows excellent freedom from structural valve deterioration. Structural valve deterioration in the Freestyle stentless bioprosthesis relates to leaflet tear with minimal calcification in the majority of cases. Because of the fast onset of symptoms with leaflet tear, patients with a Freestyle stentless bioprosthesis should be informed of the preferential mode of failure and time-frame of symptoms.

Aged↗

Hydrogen peroxide as an irrigation solution in arthroplasty - a potential contributing factor to the development of aseptic loosening.

The reason for revision of primary total hip arthroplasty is quoted as aseptic loosening in 60.6% of cases between 1979 and 2003 in the Swedish National Hip Arthroplasty Registry. Much research effort has been directed toward enhancing the bone-cement interface of total joint arthroplasties, in an attempt to reduce this complication. Haemostatic agents have been popularized as effective means of retarding the development of potentially harmful debris interposition adjacent to, and blood lamination patterns within, the methylmethacrylate. Such agents include hydrogen peroxide (H(2)O(2)), local freezing saline, saline at room temperature and adrenaline solution. One main concern with the use of hydrogen peroxide is whether it affects the material properties of bone cement such that in the long term it contributes to aseptic loosening. This would have enormous clinical consequences. Preliminary studies indicate that porosity increases and that the tensile strength and yield stresses are reduced by up to a factor of 10 by contaminating samples with increasing concentrations of hydrogen peroxide. We postulate that the current use of hydrogen peroxide as an irrigation solution in arthroplasty contributes to the development of aseptic loosening.

Adhesiveness↗

Effect of atrial overdrive pacing on obstructive sleep apnea in patients with systolic heart failure.

BACKGROUND AND PURPOSE: Obstructive sleep apnea (OSA) is associated with cardiovascular disease. Preliminary studies suggested breathing improvement in patients with apnea and heart disease when atrial overdrive pacing was applied during sleep. However, more recent studies do not show significant beneficial effect for atrial overdrive pacing in OSA. To further investigate this relationship, we conducted a randomized clinical trial evaluating the effect of atrial overdrive pacing on sleep-related breathing events in subjects with OSA and systolic heart failure. PATIENTS AND METHODS: We screened 33 subjects with symptoms consistent with OSA. On a screening overnight polysomnography (PSG), 15 subjects with mean age of 74 years (standard deviation (SD) 6.6) and ejection fraction of 38% (SD 14.4%) had OSA defined as having an apnea/hypopnea index (AHI) of > or =15 per hour of sleep. These subjects underwent additional PSGs including a night with atrial overdrive pacing (O), a night with pacemaker rate set at 40-50 beats per minutes (N), and a positive airway pressure titration night. The O and N nights were consecutive and the order was randomized. For O, the pacemaker rate was set at 15 beats higher than the average nightly heart rate (determined from the screening night). RESULTS: At baseline, mean AHI was 34.8 (15.5) and mean SaO(2) nadir was 85% (3.2%). Average heart rate was significantly higher on O nights compared to N nights (p<0.005). The apnea index (AI) was statistically lower on O nights compared to N nights (18+/-16.6 vs. 24+/-18.9, p<0.05). However, AHI and minimum and average O(2) saturations did not differ significantly between O and N nights. Interestingly, AHI improved statistically significantly on O nights in younger subjects. CONCLUSIONS: While statistically reliable, the small pacing-related reduction in sleep-disordered breathing (SDB) events is of unknown clinical significance. By contrast, continuous positive airway pressure (CPAP) dramatically improved AHI, AI, respiratory arousal index, and O(2) saturation. Thus our data suggest that overdrive pacing exerts a mild effect on respiratory events in some heart failure patients with OSA; however, atrial overdrive pacing was not therapeutically effective for improving airway patency and sleep-related respiratory function.

Adult↗

Influence of the stiffness of bone defect implants on the mechanical conditions at the interface--a finite element analysis with contact.

The study focused on the influence of the implant material stiffness on stress distribution and micromotion at the interface of bone defect implants. We hypothesized that a low-stiffness implant with a modulus closer to that of the surrounding trabecular bone would yield a more homogeneous stress distribution and less micromotion at the interface with the bony bed. To prove this hypothesis we generated a three-dimensional, non-linear, anisotropic finite element (FE) model. The FE model corresponded to a previously developed animal model in sheep. A prismatic implant filled a standardized defect in the load-bearing area of the trabecular bone beneath the tibial plateau. The interface was described by face-to-face contact elements, which allow press fits, friction, sliding, and gapping. We assumed a physiological load condition and calculated contact pressures, shear stresses, and shear movements at the interface for two implants of different stiffness (titanium: E=110GPa; composite: E=2.2GPa). The FE model showed that the stress distribution was more homogeneous for the low-stiffness implant. The maximum pressure for the composite implant (2.1 MPa) was lower than for the titanium implant (5.6 MPa). Contrary to our hypothesis, we found more micromotion for the composite (up to 6 microm) than for the titanium implant (up to 4.5 microm). However, for both implants peak stresses and micromotion were in a range that predicts adequate conditions for the osseointegration. This was confirmed by the histological results from the animal studies.

Animals↗