Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77Linked to original sources

Fluorescence imaging of light absorption for axial-beam geometry in capillary electrophoresis.

A new method for investigation of axial-beam absorption detection for improved detection limits in microcolumn separations is reported. The method is based on fluorescence imaging of light absorption along a separation capillary. The probing UV light is introduced at one end of the capillary and shows an exponential fall-off along the capillary. As the UV light propagates through the sample peaks, an additional loss in intensity will be observed. In order to view the absorption profile along the capillary, a background fluorophore is added to the buffer. A charge-coupled device (CCD) detector and imaging optics are placed beside the capillary to view the capillary in a direction perpendicular to the capillary. Signal integration is employed for consecutive exposures as well as for neighboring detector pixels in order to increase the signal-to-noise ratio. Measurements for stilbene 3 with sulforhodamine B as a background fluorophore are presented. The characteristics of the detection method and potential improvements are discussed.

Electrophoresis, Capillary↗

Influence of the reamer shape on intraosseus pressure during closed intramedullary nailing of the unbroken femur: a preliminary report.

The generation of intramedullary pressure during reaming of the femur was compared for two different reamer systems: the AO/ASIF universal reamer and the Gray flexible reamer system (Howmedica), while reaming in 9 oncologic patients undergoing prophylactic nailing of metastatic femora as indicated by impending fractures (unbroken femora). An intracranial fibre optic catheter pressure-monitoring device inserted through the distal supracondylar cortex was used to perform measurements. Preliminary data are presented. Maximum pressures of up to 450 mmHg were recorded during reaming with the smaller 9.0 and 9.5 mm theta reamers. Rapid penetration of the reamer in both proximal and distal metaphyses caused much higher pressures than reaming the cortex of the diaphysis. Speed of penetration and volume of the reaming shaft were found to be important parameters. No significant differences between maximal pressures generated by the two types of reamers could be observed.

Adult↗

CCD line-scan image sensor for the measurement of red cell velocity in microvessels.

A device for measuring red cell velocities in transilluminated microvessels has been developed using a 256 element charge-coupled device (CCD) line scan sensor. An image of the moving red cells is focussed on the device so that it senses optical data along the flow axis. Paired sets of data, separated by a fixed time interval, are sampled by an A/D converter operating at 1 MHz, and transferred to a dedicated microcomputer employing the MC68000 (Motorola Inc.) microprocessor. Velocity is computed from the detected spatial shift occurring in the time between data sets. The computed velocity is converted to an analogue voltage. Calibration is linear, the system is direction-sensitive and it can detect zero motion.

Animals↗

A simple device for the computer quantification of depth measurements in thick light microscope sections.

The use of computerized techniques to characterize quantitatively the anatomy of individual neurons has been increasing. One difficulty has been the quantification of the z-axis or depth measurements within thick light microscopic sections. In the present report we describe a simple device which employs an incremental optical encoder to transduce the movements of the focusing knob of the microscope so that depth information can be recorded directly by a computer. A resolution of 0.13 micron over a range of approximately 8.5 cm is achieved. The mechanical interface to the microscope is simple and applicable to a wide variety of microscopes. Interfacing circuits which allow the optical encoder to be used with an IBM-PC compatible computer are presented and described. The accuracy of the depth measurements is limited only by the mechanical tolerances of the focusing mechanism and by the optics of the microscope.

Electric Wiring↗

[Laparoscopic pelvic lymphadenectomy: role of the surgeon assistant].

Laparoscopy has emerged as a valid alternative to open surgery. Surgery assistance is a full part within the learning of Laparoscopy. Even more than in open surgery, efficient assistance facilitates the surgeon's work and helps shortening the intervention duration. Basic principles are detailed, such as the number and the position of trocars, or how to adequately manipulate optic and camera or suction devices. Specific gesture of the assistant during a pelvic Laparoscopic Lymphadenectomy is presented step by step, with the procedure undertaken by intra- or extra-peritoneal approach.

General Surgery↗

An fMRI study of the Trail Making Test.

This study investigated the cerebral correlates of the Trail Making Test (TMT), used commonly as a measure of frontal lobe function. Such work sheds additional light on the known shortcomings of the TMT as a localizing instrument, as indicated, for example, by studies of patients with focal brain lesions. Functional magnetic resonance imaging (fMRI) was used to record brain activity while participants performed the TMT using a custom-built, fiber-optic fMRI-compatible writing device, the "virtual stylus". Unlike in a previous fMRI study that used a verbal adaptation of the TMT, the virtual stylus enabled a closer depiction of the brain regions engaged by the actual paper-and-pencil task. Twelve, right-handed healthy young adults participated. In Part A of the task, participants were required to link in ascending order numbers (1-2-3 ...) that were randomly distributed on a computer screen. In Part B, participants were required to link alternately between numbers and letters (1-A-2-B ...). Although behavioral performance was somewhat less than typically obtained with the TMT due to use of the virtual stylus, distinct left-sided dorsolateral and medial frontal activity was revealed when comparing Part B versus Part A. These findings agree with existing literature showing sensitivity of the TMT to frontal regions in the left hemisphere. However, other activity was also observed (left middle and superior temporal gyrus) reinforcing that the brain-behavior correlations for the TMT are multifaceted and not restricted to the frontal lobe.

Adult↗

Fabrication of calcium fluoride capillary electrophoresis microdevices for on-chip infrared detection.

In this paper, we demonstrate microfluidic capillary electrophoresis (CE) devices made in CaF2 , for optical detection in a broad spectral range. We have designed methods for micromachining and enclosing capillaries in CaF2. The utility of these microdevices has been shown through CE analysis of fluorescently labeled amino acids. We have also performed infrared spectroscopy for analyte identification in microfluidic CaF2 channels. These CaF2 microdevices open the door to microchip separations with optical detection in the ultraviolet, visible, and infrared spectral regions.

Calcium Fluoride↗

Bioencapsulation within synthetic polymers (Part 1): sol-gel encapsulated biologicals.

Since its inception a decade ago, sol-gel encapsulation has opened up an intriguing new way to immobilize biological materials. An array of substances, including catalytic antibodies, DNA, RNA, antigens, live bacterial, fungal, plant and animal cells and whole protozoa, have been encapsulated in silica, metal-oxide, organosiloxane and hybrid sol-gel polymers. The advantages of these 'living ceramics' might give them applications as optical and electrochemical sensors, diagnostic devices, catalysts, and even bioartificial organs. With rapid advances in sol-gel precursors, nanoengineered polymers, encapsulation protocols and fabrication methods, this technology promises to revolutionize bioimmobilization.

Biological Factors↗

Full field digital mammography scanner.

We describe the key features of a pre-production, slot-scan digital mammography system. A number of these units have been used in clinical studies over the past year for the purpose of demonstrating their equivalence to the conventional film-screen devices. Since the clinical data has not yet been fully analyzed, it is not possible to make definitive claims. However, with hundreds of patients examined, the results appear to leave very little doubt the SenoScan digital mammography system will prove equivalent to the conventional technology. The detector developed for this system has a sensitive area 1.0 cm wide by 22 cm long. It is constructed by abutting four charge-coupled-device (CCD) chips, which are optically coupled to thallium-doped cesium iodide scintillator by means of a thin fiber optic plate. Scanning is accomplished by attaching the detector to a rigid arm that swings in an arc, with the axis of rotation collinear with the X-ray tube focal spot. The total scan time for the 30 cm image width is less than 6 s, with an effective exposure time of either 0.2 or 0.4 s. Two resolution modes are available: 0.054 mm or 0.027 mm square pixel size; in the latter mode both the image length and width are halved, as is the scan velocity, so that the scan time remains the same. To compensate for the low X-ray utilization efficiency of the slot geometry, a tungsten rhenium target X-ray tube is employed. It is rated at 8 kW on the 0.3 mm focal spot; when used with a heat exchanger, it has been found to provide the patient throughput needed in a busy clinical practice.

Breast Diseases↗

Multiwavelength spectrophotometric determination of acid dissociation constants of ionizable drugs.

A multiwavelength spectrophotometric approach has been developed to determine acid dissociation constants (pKa values) of sparingly soluble drug compounds. UV absorption spectra of the drug solution are acquired using a versatile device based on a fiber optics dip probe, a light source and a photodiode array (PDA) detector while the PH and the ionic strength of the chemical system is manipulated precisely by means of a commercially available titrator. Target factor analysis (TFA) has been applied to deduce the pKa values from the multiwavelength UV absorption data recorded at different pH values. We have called this multiwavelength approach the WApH technique because the pKa results are determined from changes in Wavelength and Absorbance as a function of pH (WApH). The WApH technique is exemplified by using several pure drugs, namely, niflumic acid, nitrazepam, pyridoxine, quinine and terbutaline. The pKa values obtained agree well with those derived from pH-metric titrations. It has been demonstrated that the WApH technique is able to deduce pKa values with high accuracy even if the absorption spectra of the reacting species are very similar.

Hydrogen-Ion Concentration↗

An automated, handheld biosensor for aflatoxin.

A new immunoaffinity fluorometric biosensor has been developed for detecting and quantifying aflatoxins, a family of potent fungi-produced carcinogens that are commonly found in a variety of agriculture products. They have also been cited as a biological agent under weapons development. The handheld, self-contained biosensor is fully automatic, highly sensitive, quick, quantitative, and requires no special storage. Approximately 100 measurements can be made before refurbishment is required, and concentrations from 0.1 parts per billion (ppb) to 50 ppb can be determined in <2 min with a 1 ml sample volume. The device operates on the principles of immunoaffinity for specificity and fluorescence for a quantitative assay. The analytic procedure is flexible so that other chemical and biological analytes could be detected with minor modifications to the current device. Advances in electro-optical components, electronics, and miniaturized fluidics were combined to produce this reliable, small, and versatile instrument.

Aflatoxins↗

Contrast-detail detectability analysis: comparison of a digital spot mammography system and an analog screen-film mammography system.

RATIONALE AND OBJECTIVES: The authors compared the contrast-detail detectability properties of an optically coupled charge-coupled device (CCD) digital mammography system with those of a conventional analog screen-film mammography system. METHODS: A proprietary contrast-detail phantom was imaged with both systems. Twelve observers viewed analog and digital images obtained at seven different mean glandular doses. Contrast-detail-dose curves were generated on the basis of the readers' visual perceptions. Interobserver errors were also calculated. In addition, the authors applied a theoretical model for lesion detectability to calculate and compare the digital and analog mammography systems. RESULTS: The readers' contrast-detail detectability was significantly superior with the digital system in the detail and contrast ranges evaluated (P < .001). CONCLUSION: The performance of the readers paralleled the performance predicted by the theoretical model for the two imaging systems. The following features account for the superior performance of the digital mammography system: (a) higher quantum efficiency of the phosphor, (b) wider dynamic range, (c) better contrast transfer characteristics, and, most important, (d) greater photon flux at the phosphor entrance.

Contrast Sensitivity↗

Bisdioxaborine polymethines with large third-order nonlinearities for all-optical signal processing.

Organic materials with large third-order nonlinearities in the near-infrared spectral regime are critical in the development of photonic devices to be utilized in all-optical signal processing. We have developed polymethine materials, specifically bisdioxaborine-terminated polymethine dyes, which possess large ultrafast third-order nonlinearities and low nonlinear loss all in the near-infrared spectral regime. An extended bisdioxaborine polymethine anion exhibited the largest value of gamma (third-order microscopic nonlinearity) at 1.3 mum (|gamma| = 5.7 x 10-32 esu) and showed no characteristics of symmetry breaking, unlike other polymethines of similar lengths. A neat film of this molecule maintained relatively low linear loss in the near-infrared and showed a large third-order macroscopic nonlinearity at 1.3 mum (|chi(3)| = 3.6 x 10-10 esu), with a temporal response of less than 8 ps. Furthermore, the real part of chi(3) was nearly an order-of-magnitude larger than the imaginary component. Consequently, this material exhibited good figures of merit for all-optical signal processing throughout the entire telecommunications band.

Journal Article↗

Dark-field oxidative addition-based chemosensing: new bis-cyclometalated PtII complexes and phosphorescent detection of cyanogen halides.

Heavy metal complexes that are phosphorescent at room temperature are becoming increasingly important in materials chemistry, principally due to their use in phosphorescent organic light-emitting devices (OLEDs). Their use in optical sensory schemes, however, has not been heavily explored. Homoleptic bis-cyclometalated Pt(II) complexes are known to undergo oxidative addition with appropriate electrophiles (principally alkyl halides) by either thermal or photochemical activation. We have applied this general reaction scheme to the development of a phosphorescence-based sensing system for cyanogen halides. To carry out structure-property relationship studies, a series of previously unreported Pt(II) complexes was prepared. Most of the complexes (excluding those that incorporated substituents on the ligands that forced steric crowding in the square plane) were strongly orange-red phosphorescent (Phi = 0.2-0.3) in a room-temperature oxygen-free solution. These sterically demanding ligands also accelerated the addition of cyanogen bromide to these complexes but slowed the addition of methyl iodide, indicating that the oxidative addition mechanisms for these two electrophiles is different. The lack of solvent-polarity effect on the addition of BrCN suggests a radical mechanism. Oxidative addition of BrCN to the metal complexes in solution or dispersed in poly(methyl methacrylate) gave blue-shifted emissive Pt(IV) complexes. The blue-shifted products give a dark-field sensing scheme that is in sharp contrast to energy transfer-based sensing schemes, which have limited signal-to-noise because of the presence of lower-energy vibronic bands of the energy donor that can overlap with the emission of the acceptor.

Crystallography, X-Ray↗

Nondestructive monitoring of the photochromic state of dithienylethene monolayers by surface plasmon resonance.

The use of surface plasmon resonance (SPR) as a nondestructive, nonerasing readout of the isomerization state of a photochromic dithienylethene covalently linked to a chemically modified gold surface was investigated. Four different binding layers were examined: 11-mercaptoundecanol (MUO), an amine-modified 11-mercaptoundecanol (MUO-NH2), dextran, and an amine-modified dextran. The binding of dithienylethene to the modified gold surface and photoisomerization of the photochrome in the bound state were established by FTIR. Solvent effects were measured for every layer tested using ethanol and hexanes. In general, large, easily measurable SPR signal changes could be detected under conditions where photoisomerization of the dithienylethene photochrome was not quenched by the gold plasmon, establishing SPR as a viable form of readout for potential dithienylethene-based optical data storage or processing devices. Dextran-bound photochrome in ethanol exhibited the largest SPR response upon photoisomerization, but is more prone to time-dependent fluctuations resulting from swelling of the dextran layer (caused by slow diffusion of the solvent) than the other layers. Large responses are also provided by MUO-NH2 and MUO, and the signal is much more stable than that for dextran.

Journal Article↗

Metallic photonic crystals based on solution-processible gold nanoparticles.

We demonstrate the fabrication of metallic photonic crystals, in the form of a periodic array of gold nanowires on a waveguide, by spin-coating a colloidal gold suspension onto a photoresist mask and subsequent annealing. The photoresist mask with a period below 500 nm is manufactured by interference lithography on an indium tin oxide (ITO) glass substrate, where the ITO layer has a thickness around 210 nm and acts as the waveguide. The width of the nanowires can be controlled from 100 to 300 nm by changing the duty cycle of the mask. During evaporation of solvent, the gold nanoparticles are drawn to the grooves of the grating with apparently complete dewetting off the photoresist for channels less than 2 microm in width, which therefore form nanowires after the annealing process. Strong coupling between the waveguide mode and the plasmon resonance of the nanowires, which is dependent on the polarization and incidence angle of the light wave, is demonstrated by optical extinction measurements. Continuity of the nanowires is confirmed by conductivity properties. Simplicity, high processing speed, and low cost are the main advantages of this method, which may have a plethora of applications in telecommunication, all-optical switching, sensors, and semiconductor devices.

Crystallization↗

Embossed polymer leaky waveguide devices for spectroscopic analysis.

A combination of UV embossing, hot embossing and laminating techniques have been exploited during the fabrication of grating-coupled waveguiding devices in which the flow channel materials and geometry are designed for the effective support of light condenser modes through a sample solution. Used in conjunction with LED sources, these devices have been employed as optical platforms to obtain fluorescence emission and molecular absorption spectra in aqueous media for microTAS (micro total analytical system) applications.

Journal Article↗

Design for an optical cw atom laser.

A new type of optical cw atom laser design is proposed that should operate at high intensity and high coherence and possibly record low temperatures. It is based on an "optical-shepherd" technique, in which far-off-resonance blue-detuned swept sheet laser beams are used to make new types of high-density traps, atom waveguides, and other components for achieving very efficient Bose-Einstein condensation and cw atom laser operation. A shepherd-enhanced trap is proposed that should be superior to conventional magneto-optic traps for the initial collection of molasses-cooled atoms. A type of dark-spot optical trap is devised that can cool large numbers of atoms to polarization-gradient temperatures at densities limited only by three-body collisional loss. A scheme is designed to use shepherd beams to capture and recycle essentially all of the escaped atoms in evaporative cooling, thereby increasing the condensate output by several orders of magnitude. Condensate atoms are stored in a shepherd trap, protected from absorbing light, under effectively zero-gravity conditions, and coupled out directly into an optical waveguide. Many experiments and devices may be possible with this cw atom laser.

Journal Article↗