Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77Linked to original sources

Mass spectrometric studies of cisplatin-induced changes of hemoglobin.

This study reports on structural changes of hemoglobin (Hb) that were induced by cisplatin binding. Two techniques, nanoelectrospray quadrupole time-of-flight mass spectrometry (nanoES-MS) and high-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC/ICPMS), were developed to facilitate this study. Nanospray MS analyses of cisplatin and Hb reaction mixtures demonstrated that the ion at m/z 616.5, the heme group, increased with an increase of cisplatin concentration, indicating the loss of heme groups from the intact protein. This conclusion was also supported by the increase of cisplatin-alpha or -beta complex formation. The change of the Hb-bound Fe was further investigated by monitoring Fe signals using size-exclusion HPLC/ICPMS. After incubation with cisplatin at clinically relevant concentrations, under physiological conditions, the amount of Fe bound to Hb was reduced while formation of cisplatin-Hb complexes increased. Flow-injection ICPMS analysis of the Fe contents in the low molecular weight fraction (<3000 Da) of the reaction mixtures after size fractionation further demonstrated a corresponding increase of Fe with the increase of cisplatin concentrations. HPLC/ICPMS detected three Hb-cisplatin complexes, one of which eluted at the same retention time as Hb while the other two complexes eluted later than Hb. With clinically relevant concentrations of cisplatin (0.05-1.0 microM) and 10 microM of Hb, the concentrations of the Hb-cisplatin complexes were determined in the range 0.1-64 nM. These results, obtained from nanoES-MS, HPLC/ICPMS, and FIA-ICPMS, demonstrate that cisplatin binding to Hb resulted in the dissociation of the heme group from the intact protein.

Binding Sites↗

Ionization enhancement in atmospheric pressure chemical ionization and suppression in electrospray ionization between target drugs and stable-isotope-labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry.

The phenomena of ionization suppression in electrospray ionization (ESI) and enhancement in atmospheric pressure chemical ionization (APCI) were investigated in selected-ion monitoring and selected-reaction monitoring modes for nine drugs and their corresponding stable-isotope-labeled internal standards (IS). The results showed that all investigated target drugs and their co-eluting isotope-labeled IS suppress each other's ionization responses in ESI. The factors affecting the extent of suppression in ESI were investigated, including structures and concentrations of drugs, matrix effects, and flow rate. In contrast to the ESI results, APCI caused seven of the nine investigated target drugs and their co-eluting isotope-labeled IS to enhance each other's ionization responses. The mutual ionization suppression or enhancement between drugs and their isotope-labeled IS could possibly influence assay sensitivity, reproducibility, accuracy and linearity in quantitative liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, calibration curves were linear if an appropriate IS concentration was selected for a desired calibration range to keep the response factors constant.

Artifacts↗

Segmented post-column analyte addition; a concept for continuous response control of liquid chromatography/mass spectrometry peaks affected by signal suppression/enhancement.

A novel technique, "segmented post-column analyte addition", is proposed to visualize and compensate signal suppression/enhancement effects in electrospray ionization tandem mass spectrometry (ESI-MS/MS). Instead of delivering a constant flow of analyte solution between the liquid chromatography (LC) column exit and the ESI interface into the eluent resulting from LC separation of analyte-free matrix in order to determine retention time widows in which suppression/enhancement is unimportant (King et al., J. Am. Soc. Mass Spectrom. 2000; 11: 942), segmented packets of analyte-containing solvent and analyte-free solvent were infused into an LC eluent resulting from separation of an analyte-containing sample. The obtained, superimposed, periodic spikes are much narrower than the analyte peak eluting from the column. The height of the spikes is affected by signal suppression phenomena to the same extent as the analyte signal, and hence variations of the spike height can be used to correct the peak area of analyte peaks affected by signal suppression/enhancement.

Algorithms↗

Reliable determination of oxygen and hydrogen isotope ratios in atmospheric water vapour adsorbed on 3A molecular sieve.

The isotope ratio of atmospheric water vapour is determined by wide-ranging feedback effects from the isotope ratio of water in biological water pools, soil surface horizons, open water bodies and precipitation. Accurate determination of atmospheric water vapour isotope ratios is important for a broad range of research areas from leaf-scale to global-scale isotope studies. In spite of the importance of stable isotopic measurements of atmospheric water vapour, there is a paucity of published data available, largely because of the requirement for liquid nitrogen or dry ice for quantitative trapping of water vapour. We report results from a non-cryogenic method for quantitatively trapping atmospheric water vapour using 3A molecular sieve, although water is removed from the column using standard cryogenic methods. The molecular sieve column was conditioned with water of a known isotope ratio to 'set' the background signature of the molecular sieve. Two separate prototypes were developed, one for large collection volumes (3 mL) and one for small collection volumes (90 microL). Atmospheric water vapour was adsorbed to the column by pulling air through the column for several days to reach the desired final volume. Water was recovered from the column by baking at 250 degrees C in a dry helium or nitrogen air stream and cryogenically trapped. For the large-volume apparatus, the recovered water differed from water that was simultaneously trapped by liquid nitrogen (the experimental control) by 2.6 per thousand with a standard deviation (SD) of 1.5 per thousand for delta(2)H and by 0.3 per thousand with a SD of 0.2 per thousand for delta(18)O. Water-vapour recovery was not satisfactory for the small volume apparatus.

Adsorption↗

High-throughput direct-infusion ion trap mass spectrometry: a new method for metabolomics.

A fast method was developed to directly infuse raw plant extracts into a linear ion trap mass spectrometer, using the ion trap to isolate and fragment as many ions as possible from the extract. The full mass spectra can be analysed by multivariate statistics to determine discriminating ions, and the fragmentation data allows rapid classification or identification of these ions. The methodology was used to screen a wide range of strains of endophytic fungi in perennial ryegrass seeds for differences in metabolic profiles. The results show that this newly developed methodology is able to determine discriminating ions that can be present in very low concentrations. It also yielded sufficient fragmentation data to classify or identify the discriminating ions.

Ascomycota↗

Characterization and sequence confirmation of unnatural amino acid containing peptide libraries using electrospray ionization mass spectrometry.

The content of 24 12-membered heptapeptide libraries was investigated using capillary liquid chromatography coupled with an electrospray ionization quadrupole orthogonal acceleration time-of-flight mass spectrometer. Adjustment of the chromatographic parameters led to the separation of most of the components. Extraction of the [M + 2H]2+ ions allowed us to demonstrate the presence of all expected species in the library and to evaluate their relative abundance in the mixture. Rapid sequence confirmation was achieved by subtraction of product ion spectra, a way to eliminate common ions and to simplify the spectra for interpretation. This technique can also easily be applied to other libraries consisting of components with a common core.

Amino Acid Sequence↗

Rapid quantitation of globotriaosylceramide in human plasma and urine: a potential application for monitoring enzyme replacement therapy in Anderson-Fabry disease.

A method for measuring globotriaosylceramide (Gb3, or GL3) levels in plasma and urine of humans affected by Anderson-Fabry disease has been developed. The analyses are performed using flow injection analysis-electrospray ionization-tandem mass spectrometry (FIA-ESI-MS/MS). The method is rapid, sensitive and hence suitable for high-throughput analyses, requiring only a simple 50-fold dilution for the preparation of plasma and urine samples. The detection of the analytes of interest was achieved using a triple quadrupole instrument operating in the multiple reaction monitoring mode. The linearity of the calibration standard responses, the intra- and inter-assay precision, the accuracy and the detection limit of the method were evaluated. The proposed method allows a rapid and accurate assessment of globotriaosylceramide in biological samples. Data obtained from healthy volunteers and Anderson-Fabry affected subjects suggest a potential role for this technique in monitoring the effectiveness of Anderson-Fabry disease therapy. The results obtained in two actual cases treated with enzyme replacement therapy are reported and discussed.

Fabry Disease↗

Determination of total urinary mercury by on-line sample microwave digestion followed by flow injection cold vapour inductively coupled plasma mass spectrometry or atomic absorption spectrometry.

The total mercury content in urine was determined by inductively coupled plasma mass spectrometry with the so-called cold vapour method after on-line oxidative treatment of the sample in a microwave oven (FI-MW-CV-ICPMS). Use of a KBr/KBrO(3) mixture, microwave digestion, and the final oxidation with KMnO(4), assure the complete recovery of the organic forms of Hg which would be difficult to determine otherwise if using only the CV-ICPMS apparatus. Quantitative recoveries were obtained for phenyl Hg chloride (PMC), dimethyl Hg (DMM), Hg acetate (MA) and methyl Hg chloride (MMC). Use of automatic flow injection microwave systems (FI-MW) for sample treatment reduces environmental contamination and allows detection limits suitable for the determination of reference values. Since no certified reference materials were commercially available in the concentration ranges of interest, the accuracy of the proposed procedure has been assessed by analysing a series of urine samples with two independent techniques, ICP-MS and AAS. When using the FI-MW-CV-ICP-MS technique, the detection limit was assessed at 0.03microg/L Hg, while with FI-MW-CV-AAS it was 0.2microg/L Hg. The precision of the method was less than 2-3% for FI-MW-CV-ICP-MS and about 3-5% for FI-MV-CV-AAS at concentrations below 1microg/L Hg. These results show that ICP-MS can be considered as a "reference technique" for the determination of total urinary Hg at very low concentrations, such as are present in non-exposed subjects.

Adult↗

Nitric oxide modulates the activity of the hemoproteins prostaglandin I2 synthase and thromboxane A2 synthase.

Nitric oxide modulates the activity of the hemoprotein isomerase enzymes that transform prostaglandin H2 into prostaglandin I2 and thromboxane A2. Two nitric oxide donors, 1-hexanamine, 6-(2hydroxy-1-methyl-2-nitrosohydrazino)-N-methyl-nitroso- hydrazine (MMNN) and 1,1-diethyl-2-hydroxy-2-nitrosohydrazine, modulated prostaglandin I2 synthase activity in a bidirectional manner. At moderate concentrations, they increased enzyme activity irreversibly and at higher concentrations they inhibited enzyme activity reversibly. We confirmed that these effects originated from nitric oxide. First, we showed that hemoglobin, a substance that sequesters nitric oxide, prevented both the activation and the inhibition of catalysis, stoichiometrically. Second, we showed that solutions depleted of nitric oxide had no effect on catalysis. Nitric oxide also modulated thromboxane A2 synthase activity; however, its effects on thromboxane A2 synthase differed from its effects on prostaglandin I2 synthase in three ways: (i) It inhibited thromboxane A2 synthase in a concentration-dependent manner. The IC50 = 4.2 +/- 0.8 microM MMNN corresponded to an IC50 congruent with 0.1-0.3 microM nitric oxide. (ii) It did not increase thromboxane A2 synthase activity at any concentration tested. (iii) Its irreversible inhibition of thromboxane A2 synthase contrasted with its reversible inhibition of prostaglandin I2 synthase. Nitric oxide also inhibited cellular formation of thromboxane A2 by intact platelets in a concentration-dependent manner. The IC50 = 267 +/- 26 microM MMNN corresponded to an IC50 congruent with 6-18 microM nitric oxide. We conclude that nitric oxide can modulate certain hemoprotein enzymes in the biosynthetic cascade that governs the formation of eicosanoid mediators of thrombosis and hemostasis.

Animals↗

Inhibition of hyaluronidase by fully O-sulfonated glycosaminoglycans.

We report a new flow injection assay (FIA) method for determining hyaluronidase activity and the inhibitory effects of chemical fully O-sulfonated glycosaminoglycans on this enzyme. The products of enzymatic action on hyaluronidase can be detected by FIA using fluorometric detection with the fluorogenic reagent 2-cyanoacetamide. The major products derived from hyaluronan by the action of mammalian testicular hyaluronidase (a hydrolyase) were confirmed by (1)H NMR spectroscopy and capillary electrophoresis. The FIA method was next applied to the assay of hyman urinary hyaluronidase activity and the screening of hyaluronidase inhibitors. The human urinary hyaluronidase activity measured ranged from 46 to 59 turbidity reducing units/mg protein. Among the glycosaminoglycans only heparin showed hyaluronidase inhibition. Chemically O-sulfonated glycosaminoglycans showed IC(50) values of hyaluronidase inhibition that correlated with the degree of O-sulfonation. Heparin was found to inhibit hyaluronidase activity noncompetitively, while chemically O-sulfonated HA strongly inhibited hyaluronidase through both competitive and noncompetitive effects.

Enzyme Inhibitors↗

On the oxidation of cytochrome c by hypohalous acids.

Oxidation of cytochrome c, a key protein in mitochondrial electron transport and a mediator of apoptotic cell death, by reactive halogen species (HOX, X2), i.e., metabolites of activated neutrophils, was investigated by stopped-flow. The fast initial reactions between FeIIIcytc and HOX species, with rate constants (at pH 7.6) of k > 3 x 10(6) M(-1) s(-1) for HOBr, k > 3 x 10(5) M(-1) s(-1) for HOCl, and k = (6.1+/-0.3) x 10(2) M(-1) s(-1) for HOI, are followed by slower intramolecular processes. All HOX species lead to a blue shift of the Soret absorption band and loss of the 695-nm absorption band, which is an indicator for the intact iron to Met-80 bond, and of the reducibility of FeIIIcytc. All HOX species do, in fact, persistently impair the ability of FeIIIcytc to act as electron acceptor, e.g., in reaction with ascorbate or O2*-. I2 selectively oxidizes the iron center of FeIIcytc, with a stoichiometry of 2 per I2, and with k(FeIIcytc + I2) approximately 4.6 x 10(4) M(-1) s(-1) and k(FeIIcytc + I2*-) = (2.9+/-0.4) x 10(8) M(-1) s(-1). Oxidation of FeIIcytc by HOX species is not selectively directed toward the iron center; HOBr and HOCl are considered to react primarily by N-halogenation of side chain amino groups, and HOI mainly by sulfoxidation. There is some evidence for the generation of HO* radicals upon reaction of HOCl with FeIIcytc. Chloramines (e.g., NH2Cl), bromamine (NH2Br), and cyclo-Gly2 chloramide oxidize FeIIcytc slowly and unselectively, but iodide efficiently catalyzes reactions of these N-halogens to yield fast selective oxidation of the iron center; this is due to generation of I2 by reaction of I- with the N-halogen and recycling of I- by reaction of I2 with FeIIcytc. Iodide also catalyzes methionine sulfoxidation and thiol oxidation by NH2Cl. The possible biological relevance of these findings is discussed.

Bromates↗

Effects of lipids on the interaction of SecA with model membranes.

The effects of nonlamellar-prone lipids, diacylglycerol and phosphatidylethanolamine (PE), on the kinetic association of SecA with model membranes were examined by measuring changes in the intrinsic emission fluorescence with a stopped-flow apparatus. Upon interaction with standard liposomes composed of 50 mol% dioleolyphosphatidylcholine (DOPC) and 50 mol% of dioleoylphosphatidylglycerol (DOPG), the intrinsic fluorescence intensity of SecA was decreased after a lapse of time with a rate constant of 0.0049 s(-1). When the DOPC of the standard vesicles was gradually replaced with either dioeloyl PE (DOPE) or Escherichia coli (E. coli) PE, the rate constant increased appreciably as a function of PE concentration, in the order DOPE > E. coli PE. In addition, when the PE of E. coli PE/DOPG (50/50) vesicles was replaced with more than 5 mol% dioleoylglycerol (DOG), the rate constant further increased by 40%. The incorporation of nonlamellar-prone lipids in the vesicles also enhanced the binding of SecA to model membranes in the order DOPE > or = E. coli PE/DOG > E. coli PE > DOPC. These results provide the first kinetic evidence for the importance of nonlamellar-prone phospholipids for the association rate of SecA with membranes.

Adenosine Triphosphatases↗

A flow-injection biosensor system for the amperometric determination of creatinine: simultaneous compensation of endogenous interferents.

A flow-injection biosensor system was developed for the amperometric determination of creatinine based on coupled reactions of three sequentially aligned enzyme reactors, creatinine deiminase, glutamate dehydrogenase, and glutamate oxidase, using an oxygen electrode as the detector. To overcome the problem of endogenous ammonia and glutamate, the flow was split into two channels after the injector and rejoined before the glutamate dehydrogenase reactor. Double peak recording was obtained by setting a delay coil and a reference column in one of the two channels. The first peak gave the sum response of creatinine, endogenous ammonia, and glutamate, and the second that of endogenous ammonia and glutamate. By this method compensation for endogenous ammonia and glutamate, as well as for interfering ascorbic acid, was achieved simultaneously. The system gave linear calibrations up to 2 mM for the first peak and 3 mM for the second one. The lower detection limits were 0.1 and 0.02 mM for 35- and 100-microliters injection of sample, respectively. One run was completed within 2 min. The system showed good reproducibility (< 3%) and long operational stability (> 1300 runs). The assay results of creatinine in urine showed good correlation with those obtained from the chemical method of Jaffe.

Amino Acid Oxidoreductases↗

An electrochemical enzyme immunoassay for chicken luteinizing hormone: extension of the detection limit by adequate control of the nonspecific adsorption.

A noncompetitive heterogeneous enzyme immunoassay for the determination of chicken luteinizing hormone (LH) was equipped with an electrochemical endpoint in order to further enhance its sensitivity. The immunological principle of the original ELISA remained essentially unchanged, except for the fact that the peroxidase label was replaced by alkaline phosphatase, since in the upgraded version of the assay, p-aminophenyl phosphate was to be used as the substrate of alkaline phosphatase. Enzyme-generated p-aminophenol was injected into a flow-injection system and detected amperometrically in a thin-layer flow cell with a glassy carbon electrode at 0.325 V vs Ag/AgCl. A classical problem associated with this type of solid-phase immunoassay is the adsorption of proteins other than the capture antibody to the solid phase. The detection sensitivity is therefore often limited by a large background signal observed in the absence of antigen. In the present study, an experiment was designed to examine in each step of the assay the contribution of each of the potential sources of background current. It was shown that the major contribution to the background current was caused by the nonspecific adsorption of biotinylated secondary antibody. Adsorption of the secondary antibody (biotinylated goat anti-rabbit IgG) to the capture antibody (mouse anti-chicken LHbeta) was clearly a case of specific aspecificity, whereas adsorption to the solid phase itself had to be treated as a nonspecific aspecificity. Addition of 0.25% mouse serum to the secondary antibody as a source of mouse immunoglobulin could overcome the cross-reaction and markedly reduced adsorption to capture antibody. The second part of nonspecific adsorption was eliminated by using combinations of Tween 20 and bovine serum albumin as blocking agents. Controlling the adsorption of the biotinylated secondary antibody in this way decreased the detection limit from 39 pg/ml in the original assay to 2.5 pg/ml in the electrochemical version. This way, the plasma volume of samples containing on the order of 1 ng/ml LH was reduced to less than 10 microl. The linear range was 2.5-625 pg/ml. The method allowed us to measure LH in buffer and in adult and juvenile chicken plasma.

Adsorption↗