Prosthetic rehabilitation of a patient after partial rhinectomy: a clinical report.

Carcinoma of the nasal vestibule often requires radical surgical excision, which results in total or partial loss of the nose followed by radiation therapy. A noninvasive, cost-effective technique for rehabilitation of a patient with squamous cell carcinoma of the nasal vestibule following partial rhinectomy and radiation therapy using heat-polymerizing clear acrylic resin is presented.

Acrylic Resins↗

Effect of a heat-treatment on the linear dimensional change of a hard chairside reline resin.

STATEMENT OF PROBLEM: Little data are available regarding the effect of heat-treatments on the dimensional stability of hard chairside reline resins. PURPOSE: The objective of this in vitro study was to evaluate whether a heat-treatment improves the dimensional stability of the reline resin Duraliner II and to compare the linear dimensional changes of this material with the heat-polymerized acrylic resin Lucitone 550. MATERIALS AND METHODS: The materials were mixed according to the manufacturer's instructions and packed into a stainless steel split mold (50.0 mm diameter and 0.5 mm thickness) with reference points (A, B, C, and D). Duraliner II specimens were polymerized for 12 minutes in water at 37 degrees C and bench cooled to room temperature before being removed from the mold. Twelve specimens were made and divided into 2 groups: group 1 specimens (n=6) were left untreated, and group 2 specimens (n=6) were submitted to a heat-treatment in a water bath at 55 degrees C for 10 minutes and then bench cooled to room temperature. The 6 Lucitone specimens (control group) were polymerized in a water bath for 9 hours at 71 degrees C. The specimens were removed after the mold reached the room temperature. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold (baseline readings) and on the specimens to the nearest 0.001 mm. Measurements were made after processing and after the specimens had been stored in distilled water at 37 degrees C for 8 different periods of time. Data were subjected to analysis of variance with repeated measures, followed by Tukey's multiple comparison test (P<.05). RESULTS: All specimens exhibited shrinkage after processing (control, -0.41%; group 1, -0.26%; and group 2, -0.51%). Group 1 specimens showed greater shrinkage (-1.23%) than the control (-0.23%) and group 2 (-0.81%) specimens after 60 days of storage in water (P<.05). CONCLUSIONS: Within the limitations of this study, a significant improvement of the long-term dimensional stability of the Duraliner II reline resin was observed when the specimens were heat-treated. However, the shrinkage remained considerably higher than the denture base resin Lucitone 550.

Acrylic Resins↗

Mechanical properties of calcium phosphate based dental filling and regeneration materials.

The objective of this study was to compare the mechanical properties of calcium phosphate cements (CPC) for possible dental applications with varied liquid and powder compositions under the same testing condition. Cements studied in this experiment were divided into two groups of CPC not containing polymer and polymeric CPC (PCPC). Cement powder was formed by combining equimolar amounts of dicalcium phosphate anhydrous and tetracalcium phosphate, or acrylic resin polymer powder mixture. The CPC specimens for the compressive strength (CS) and diametral tensile strength (DTS) measurements were prepared by mixing powder and liquid for 30 s with a powder/liquid ratio of 3:1, and subsequently packing the paste into a brass mould. The specimens were kept at 37 degrees C and 100% relative humidity for 24 h before measurements were conducted on a Universal Testing Machine with a cross-head speed of 1 mm min-1. The CS of CPC was 0.14-10.29 MPa and that of PCPC was 0.26-117.58 MPa. The DTS of CPC was 0.10-4.56 MPa and that of PCPC was 0.07-22.54 MPa. The CS and DTS were very diverse depending on the composition of powder and liquid. Some compositions showed higher values than commercial liners. Thus compositions of 2% carboxymethyl cellulose + 35% citric acid in phosphate buffered saline (PBS), 20% gelatin in PBS, 2% sodium alginate in PBS, 20-40% aqueous acrylic-maleic copolymer solution, and some of the HPMC and PMVE-Ma solutions exhibited promising formulae for dentine regenerating materials. Acrylic resin-PCPC group showed generally higher CS and DTS values. Based on this study, further studies on the reaction with odontoblast and resultant dentine regeneration should be performed using promising compositions.

Acrylic Resins↗

The effect of carbon fiber orientation on the fatigue resistance and bending properties of two denture resins.

The following conclusions were made concerning the effects of carbon fiber orientation on the flexural fatigue resistance and bending properties of two denture base acrylic resins. Hi-I resin, regardless of fiber presence or orientation, was more resistant to flexural fatigue than Lucitone resin. Carbon fibers placed perpendicular to the direction of applied stress produced the most favorable combination of increased resistance to bending and to flexural fatigue. Production of properly oriented fibers that are well centered within the resin is technically difficult and yields less predictable property improvements than result from randomly dispersed fibers.

Acrylic Resins↗

Accuracy of freely adapted resin record bases.

Forty autopolymerizing resin record bases were made; 10 bases were adapted by finger pressure on tray resin material dough, 10 bases by sprinkling orthodontic resin, and 10 of repair material by either of the two previous techniques. Stone casts and acrylic resin bases were sectioned at canine, premolar, and molar coronal planes. Width of the gap between base and cast and the thickness of the base were measured at the buccal sulcus, ridge crest, lateral palatal slope, and palatal midpoint. Measurements were made through the eyepiece of a microhardness tester. Statistical analysis of 760 pairs of measurements revealed that (1) sprinkled bases fit better than finger-adapted dough bases; (2) specifically formulated materials fit better than repair material with either technique; (3) gap widths differed at different areas of the same base; and (4) gap width was not related to base thickness at any point.

Acrylic Resins↗

Effect of polyaramid fiber reinforcement on the strength of 3 denture base polymethyl methacrylate resins.

PURPOSE: The interactive effects of synthetic polyaramid reinforcement fibers on the transverse strength of intact and repaired heat-polymerized denture base acrylic resins were investigated. MATERIALS AND METHODS: Three polymethylmethacrylate (PMMA) polymers were tested: Acron MC (GC International Corp, Scottsdale, AZ), Lucitone 199 (Dentsply International Inc, York, PA), and Microlon (The Hygienic Corp, Akron, OH). With each polymer, there were 2 controls and 4 experimental groups (n = 9 per group). The treatment groups were intact heat-polymerized PMMA control, PMMA with unreinforced repair, PMMA with polyaramid reinforced repair, intact polyaramid reinforced heat-polymerized PMMA control, polyaramid reinforced PMMA with unreinforced repair, and polyaramid reinforced PMMA with polyaramid reinforced repair. The transverse fracture strengths of the samples were measured with a 3-point bending test on a Zwick Universal Testing Machine (Zwick of America, Inc, East Windsor, CT). RESULTS: The highest mean strength at fracture was recorded with intact polyaramid reinforced heat-polymerized PMMA controls for all resins. Analysis of variance showed significant differences in transverse strength (p < .05) by experimental group, by material, and by interaction of group and material. Tukey HSD (honestly significant difference) Multiple Comparisons Test (alpha = 0.05) showed that intact polyaramid reinforced heat-polymerized PMMA controls were significantly stronger than intact heat-polymerized PMMA controls and all the other treatment groups. Use of polyaramid reinforcement in repair of unreinforced PMMA or polyaramid reinforced PMMA did not result in significantly increased transverse strength. CONCLUSIONS: Polyaramid reinforcement significantly increased the transverse strength of intact heat-polymerized PMMA. Polyaramid fibers did not significantly increase strength to reinforce PMMA repairs.

Acrylic Resins↗

Comparative evaluation of tensile bond strength of denture base resins to surface pretreated cobalt chromium base metal alloys--an in vitro study.

This study was undertaken to evaluate the tensile bond strength of acrylic resins to surface pretreated Cobalt-chromium base metal alloy. A total of 60 tensile bar specimens were prepared. One half of the bar was cast in cobalt-chromium alloy and the other half made of denture base resins attached to the alloy following surface pretreatment. Two denture base resins and five surface pre-treatments were used which included sandblasting, acid etching, use of metal adhesive primers and the combination of the above mentioned modes. Gradual axial loads were applied on the tensile bar specimen mounted on a Hounsfield tensometer till bond failure was evident. Statistical evaluation was done using Mann-Whitney U test. The study results indicate that the bond strength in those specimens wherein a combination of sandblasting, acid etching and priming was done as surface pretreatment, showed the maximum values as compared to the other groups.

Acid Etching, Dental↗

The comparison of denture-base processing techniques. Part I. Material characteristics.

Some of the physical properties for three techniques for processing acrylic resin were tested. Tests included: (1) thickness changes from a standard die which simulated the palatal and flange regions of a denture, (2) relative Rockwell surface hardness, (3) color stability, and (4) surface detail. The three processing techniques under investigation were: (1) an all-stone investing technique, (2) a silicone-gypsum investing technique, and (3) a fluid-resin technique.

Acrylic Resins↗

An appliance to correct mandibular deviation in a dentulous patient with a discontinuity defect.

The mandibular discontinuity defect is one of the most difficult problems in prosthetic dentistry. This article describes an appliance that has been used successfully in reducing or correcting the deviation in dentate patients who have experienced mandibular resection. It consists of a prefabricated integrated tube and plunger that are hinged to clear acrylic resin maxillary and mandibular appliances.

Acrylic Resins↗

Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerised.

OBJECTIVES: The aim of this study is to evaluate the effect of the different conditions of curing on the residual monomer levels, hardness and impact strength of a microwave-polymerised acrylic resin. METHODS: The material was polymerised in a microwave oven in four different conditions of power and curing time. The kinetics of release of residual monomer in water was evaluated by spectrophotometric method up to 24 h. The hardness of the sample was determined by the Rockwell method and the impact strength tested by the Charpy method. The results were subjected to statistical analysis using ANOVA and Tukey's test for comparison. RESULTS: The levels of residual monomer were found dependent upon the curing conditions and they were correlated with the values of impact strength. Significant differences were observed in this property regarding the analysed conditions (p<0.001). CONCLUSIONS: From the appropriate selection of power and time of curing of the resin, it is possible to optimise the level of residual monomer and a low cytotoxicity keeping at the same time the best mechanical properties.

Acrylic Resins↗

[Application of 4-META on adhesive opaque resin. (Part 1) Adhesive strength and the stability (author's transl)].

Mechanical devices, which has been conventionally used for retaining thermo-setting acrylic resin veneers possesses disadvantage of poor marginal sealing and requires rather complicated procedure applying on the metal casting. An application of adhesive resins to overcome these disadvantages was studied. Adhesive opaque resin consisted of MMA, epoxy acrylate, TiO2 and adhesive monomer 4-META was prepared and the adhesive bonding strength between the opaque resin and Ni-Cr alloy which is for crown and bridge works, was measured. As the results, the opaque resin applied on the metal casting with proper surface treatment showed an excellent adhesive bonding strength of 260 kg/cm2. This value did not decreased even after subjected to 300 time thermal cyclings (4 degrees C and 60 degrees C). After a three months immersion in water at 37 degrees C, adhesive bonding strength decreased slightly to 190 kg/cm2.

Acrylic Resins↗

4-META opaque resin--a new resin strongly adhesive to nickel-chromium alloy.

1) A new adhesive opaque resin containing a reactive monomer, 4-methacryloxy-ethyl trimellitate anhydride (4-META), was prepared, and its application to thermosetting acrylic resin veneer crowns was studied. 2) The 4-META opaque resin was applied to a variety of nickel-chromium dental alloy specimens which had undergone different treatment, and endurance tests were conducted to evaluate the durability of adhesion. 3) Stable adhesion against water penetration was achieved with metal surfaces first etched with HCl and then oxidized with HNO3. A bond strength of 250 kg/cm2 was maintained even after immersion in water at 37 degrees C for 30 wk or at 80 degrees C for ten wk. Furthermore, this value did not decrease even after the specimens were subjected to 500 thermal cycles. 4) The 4-META opaque resin studied can eliminate the necessity for retention devices on metal castings. 5) The smooth 4-META opaque resin should have no adverse effects on gingivae.

Acrylates↗

Effect of polyethylene fiber reinforcement on the strength of denture base resins polymerized by microwave energy.

This study investigated the effect of addition of polyethylene fibers on the transverse strength, deflection, and elastic modulus of two denture base acrylic resins polymerized by microwave irradiation. Specimens of each resin, Lucitone 199 and Acron MC, were fabricated with 0.0%, 0.5%, 1.5%, and 3.0% fiber loading. Specimens were tested with use of a three-point flexure apparatus with an Instron universal testing machine after storage in water for 10 days at 37 degrees C. The results showed that polyethylene fibers significantly decreased the transverse strength of Acron MC resin and slightly increased the transverse strength of Lucitone 199 resin at a loading of 0.5% by weight. Fiber loading did not significantly affect the deflection and the elastic modulus of either material.

Acrylic Resins↗

Effect of surface treatment on the bonding of an autopolymerizing soft denture liner to a denture base resin.

PURPOSE: This in vitro study evaluated the effects of surface treatments and thermocycling on the bonding of autopolymerizing silicone soft denture liner (Sofreliner) to denture base resin. MATERIALS AND METHODS: The bonding surfaces of denture base cylinders were polished with 600-grit silicon carbide paper and pretreated with applications of Sofreliner Primer, Sofreliner Primer after air abrasion, Reline Primer, or Reline Primer after air abrasion. Failure loads and elongation at failure were measured after subjecting specimens to 0, 10,000, 20,000, and 30,000 thermocycles. Failure modes were assessed for all specimens. Seven specimens were fabricated for each of 16 groups, including four pretreatments and four thermocycle groups. RESULTS: Failure loads of the Sofreliner Primer group were significantly higher than those of the air-abrasion group up to 20,000 thermocycles; both groups showed cohesive failures of the soft denture liner. Failure loads of the Reline Primer group were significantly higher than with Reline Primer after air abrasion up to 10,000 thermocycles. Failure mode after 10,000 thermocycles was cohesive for the Reline Primer group and mixed cohesive/adhesive for Reline Primer after air abrasion. Failure loads of the Sofreliner Primer group were significantly higher than those of the Reline Primer group at each thermocycling interval. Elongation values decreased after 10,000 thermocycles for all groups. CONCLUSION: Air abrasion on the denture base resin surface was not effective in enhancing failure load. Cyclic thermal stress is one factor degrading the bond between soft denture liner and acrylic resin denture base.

Acrylic Resins↗

Repairs with visible light-curing denture base materials.

Visible light-curing interpenetrating networks are newly developed materials suitable for several dental applications. These materials have several advantages, including versatility and good physicomechanical properties, but also present some weaknesses, such as increased water sorption and poor adhesion to plastic teeth. The suitability of a visible light-curing resin as a repair material, ie, its bending strength, was examined. Results were compared to those obtained with a self-curing acrylic resin. The visible light-curing resin led to repairs with lower strength.

Acrylic Resins↗

Augmenting retention of a removable partial denture repair.

A simple technique improves the retention of a tooth to be added to an existing removable partial denture. The procedure includes placing a small contoured wire into the space provided for the acrylic resin repairing material.

Acrylic Resins↗

Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens.

The potential of three types of separator materials found in conventional blood-collection tubes for interference in therapeutic drug measurements was assessed. None of the separators (based on acrylic, silicone, or polyester polymers) had any significant effect on the concentrations of seven drugs (theophylline, digoxin, phenytoin, phenobarbital, gentamicin, ethanol, and cyclosporine) in blood specimens that were processed and analyzed promptly. Storage of specimens for 24 h resulted in an average 2.4% increase in theophylline values in specimens collected in tubes with the acrylic separator (P = 0.024); an average 8.1% decrease in phenytoin in specimens collected in tubes with the polyester-based separator (P < 0.001); and an average 4.2% decrease in phenobarbital in specimens collected in tubes with the polyester-based separator (P = 0.02). All other drug concentrations were not significantly affected. A small decrease in phenytoin (7.9%; P < 0.01) was seen when the specimen volume in 7-mL tubes containing polyester-based separator was reduced to 1.0 mL; all other drug concentrations were unaffected by partial filling of tubes. Paired blood specimens from pediatric patients, when collected in plain tubes and tubes containing acrylic separator, yielded no significant differences for theophylline, digoxin, tobramycin, phenytoin, or phenobarbital concentrations. The three commercially available separators had only small effects on therapeutic drug concentrations, and a newly developed separator based on an acrylic resin was suitably inert.

Acrylic Resins↗