Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “intercept”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

The Schild regression in the process of receptor classification.

The history and derivation of the Schild equation is reviewed as well as the conditions under which the intercept of a Schild regression (the pA2, an empirical quantity) can be considered to be an estimate of the equilibrium dissociation constant of the antagonist for the receptor (KB). This parameter is of value in the classification of receptors. To be considered competitive (and, therefore, to be described in molecular terms by a KB), an antagonist must produce parallel displacement of agonist concentration-response curves with no alteration in the maximal response and thereby yield unambiguous dose ratios of agonist which are independent of agonist concentration. These dose ratios (dr) then can be utilized in the Schild equation (log (dr = 1) = n . log [B] - log KB, where [B] is the molar concentration of antagonist) in the form of a regression of log (dr - 1) on log [B]. If the regression is linear and has a slope of unity, the blockade is consistent with simple competitive antagonism and the intercept can be considered an estimate of the KB. Experimentally, the slope is a parameter critical to the assessment of competitivity. While a slope significantly different from unity may indicate that an antagonist is not competitive, it also may indicate that nonequilibrium exist in the experimental procedures. The importance of uptake mechanisms for agonists, with regards to producing underestimations of antagonist potency, are reviewed along with a concise model by Furchgott which conveniently incorporates these concepts. The possible significance of Schild regression slopes less than 1 and greater than 1 are discussed along with caveats regarding Schild regressions with slopes of unity but erroneous estimates at KB. Short discussions of the use of selective agonists, experiments in vivo, and the assessments of receptor differences from estimates of KB also are given.

Animals↗

Time/dose relationships in experimental radiation cataractogenesis.

The response of the mammalian lens to fractionated radiation exposures was evaluated as a model system for predicting delayed radiation effects on normal tissue. Only the heads of male Ha/ICR mice were irradiated with 14 different time-dose schedules and followed for cataractous changes. A log-log plot of dose vs time yielded a line with a slope of 0.303 and ordinate intercept of 1050 R; a similar plot for dose vs fraction number yielded a slope of 0.382 and ordinate intercept of 835 R. Results suggest that the lenticular response to radiation may be a useful model for studying late effects.

Animals↗

Two-compartment, two-sample technique for accurate estimation of effective renal plasma flow: theoretical development and comparison with other methods.

Discordance between effective renal plasma flow (ERPF) measurements from radionuclide techniques that use single versus multiple plasma samples was investigated. In particular, the authors determined whether effects of variations in distribution volume (Vd) of iodine-131 iodohippurate on measurement of ERPF could be ignored, an assumption implicit in the single-sample technique. The influence of Vd on ERPF was found to be significant, a factor indicating an important and previously unappreciated source of error in the single-sample technique. Therefore, a new two-compartment, two-plasma-sample technique was developed on the basis of the observations that while variations in Vd occur from patient to patient, the relationship between intravascular and extravascular components of Vd and the rate of iodohippurate exchange between the components are stable throughout a wide range of physiologic and pathologic conditions. The new technique was applied in a series of 30 studies in 19 patients. Results were compared with those achieved with the reference, single-sample, and slope-intercept techniques. The new two-compartment, two-sample technique yielded estimates of ERPF that more closely agreed with the reference multiple-sample method than either the single-sample or slope-intercept techniques.

Humans↗

Oxygen saturation of blood in the superior mesenteric vein: in vivo verification of MR imaging measurements in a canine model. Work in progress.

PURPOSE: To evaluate the accuracy of magnetic resonance (MR) imaging in estimating oxygen saturation of blood (%HbO2) in the superior mesenteric vein (SMV) of a canine model in vivo. MATERIALS AND METHODS: MR imaging was used to measure the T2 of blood in samples obtained via a catheter placed in the SMV in seven mongrel dogs. %HbO2 was measured with a reflectance oximeter. These measurements were obtained at the resting state, during superior mesenteric artery occlusion, and after reperfusion. MR imaging and oximeter measurements were then compared by using linear regression analysis. RESULTS: Refocusing intervals (tau 180) of 12 and 24 msec were used for 17 and 18 %HbO2 measurements with MR imaging, respectively. With tau 180 of 12 msec, there was an excellent correlation between MR imaging measurements and oximeter measurements (r = .969). The intercept was 5.3% and the slope was 0.959. With tau 180 of 24 msec, r = .953, the intercept was 15.4%, and the slope was 0.817. CONCLUSION: Estimates of %HbO2 in the SMV with MR imaging are accurate in the range of most clinical interest.

Animals↗

Effects of oxytocin on cation content and electrophysiology of frog skin epithelium.

We measured effects of oxytocin on current-voltage (I-V) relations of frog (Rana catesbeiana) skins impaled with an intracellular microelectrode. In both Cl- and Cl(-)-free (SO4(2-) solutions, oxytocin caused an approximate doubling short-circuit current (Isc) and a depolarization of the cell membrane. Increase in apical membrane slope conductance, chord conductance, and permeability after oxytocin correlated with the increase in amiloride-sensitive Isc. Oxytocin also increased basolateral membrane conductance (gb). In Cl-, the shift in the voltage intercept of the apical membrane I-V relation (Ea) implied increased intracellular Na+ activity (a(Na)c) after oxytocin. In isolated frog skin epithelia, a similar increase in intracellular [Na+] after oxytocin was demonstrated by flame photometry. In SO4(2-), changes caused by oxytocin in both Ea and in flame photometrically determined cell [Na+] were minimal. The voltage intercept of the basolateral membrane I-V relations (Eb) was shifted by oxytocin in both Cl- and SO4(2-) solutions. Assuming that the basolateral membrane is selectively permeable to K+, changes in K+ obtained from Eb were in disagreement with those obtained by flame photometry. These results suggest that 1) the increase in a(Na)c caused by oxytocin is not essential to produce either the increase in gb or Isc and 2) ions other than K+ make an important contribution to basolateral membrane conductance.

Animals↗

Temperature dependence of responses of esophageal smooth muscle to electrical field stimulation.

Strips of smooth muscle, cut transversely from the smooth-muscle segment of opossum esophagus, were superfused with oxygenated Krebs-Ringer solution at 37 degrees C in a system that allowed electrical field stimulation of the intrinsic nerves. Three-to-five-second trains of rectangular pulses (0.5 ms long at 10 Hz) were delivered at 30-s intervals at supramaximal maximal current strength. In strips from the esophageal body, each train resulted in a twitch which followed after the end of train with a particular latency, the off-response. Strips from the esophagogastric sphincter relaxed during the train. Temperature was varied above and below 37 degrees C to observe the temperature dependence of the responses. Latency of the off-response varied exponentially with temperature. Amplitude of the off-response showed a linear decline with changes in temperature, both above and below 35 degrees C, the zero-intercepts being 19.6 and 42.3 degrees C, respectively. Amplitude of relaxation of strips from the junction varied little between 20 and 37 degree C but declined sharply beyond those limits, the zero-intercepts being 14.2 and 42 degrees C, respectively.

Animals↗

Heated dorsal hand vein sampling for metabolic studies: a reappraisal.

The purpose of the current study was to determine the accuracy of a given heated dorsal hand vein (HDHV) measurement in predicting a simultaneous arterial measurement and to validate this technique for use in stable isotope studies. Twenty catheterizations of the femoral artery, femoral vein, and a dorsal hand vein were performed in 13 healthy male subjects. Simultaneous blood samples were obtained from all three sites during primed continuous infusions of L-[1-13C]leucine (Leu) and L-[ring-2H5]phenylalanine (Phe) in the postabsorptive state, with or without intravenous glucose infusion. Relationships were examined by linear regression analysis, with 95% prediction intervals for femoral arterial values determined using the HDHV-derived values as independent variable. Glucose concentrations and isotopic enrichments of ketoisocaproate (KIC), Leu, and Phe were similar in HDHV- and arterial-derived blood, with slopes between 0.9414 and 1.0008, intercepts not different from zero, and r2 values of 0.7613 or greater (P < 0.05). Intercepts for KIC, Leu, and Phe concentrations all were different from zero (P < 0.05), and slopes ranged between 0.7560 and 0.8625. For each analysis the HDHV sample correlated better with the femoral arterial sample than with the femoral venous sample. These data support the use of HDHV sampling as a surrogate for direct arterial sampling but document significant limitations in the technique.

Adult↗

Preload-adjusted right ventricular maximal power: concept and validation.

Right ventricular (RV) maximal power (PWR(mx)) is dependent on preload. The objective of this study was to test our hypothesis that the PWR(mx) versus end-diastolic volume (EDV) relationship, analogous to the load-independent stroke work (SW) versus EDV relationship (preload-recruitable SW, PRSW), is linear, with the PWR x-axis intercept (V(0PWR)) corresponding to the PRSW intercept (V(0SW)). If our hypothesis is correct, the preload sensitivity of PWR(mx) could be eliminated by adjusting for EDV and V(0PWR). Ten dogs were instrumented with a pulmonary flow probe, micromanometers, and RV conductance catheter. Data were obtained during bicaval occlusions under various conditions and fitted to PWR(mx) = a.(EDV - V(0PWR))(beta), where a is the slope of the relationship. The PWR(mx) versus EDV relationship did not deviate from linearity (beta = 1.09, P = not significant vs. 1), and V(0PWR) correlated with V(0SW) (r = 0.93, P <0.0001). V(0PRW) was related to steady-state EDV and left ventricular end-diastolic pressure, allowing for estimation of V(0PWR) (V(0Est)) and single-beat PWR(mx) preload adjustment. Dividing PWR(mx) by the difference of EDV and V(0PWR) (PAMP(V0PWR)) eliminated preload dependency down to 50% of the baseline EDV. PWR(mx) adjustment using V(0Est) (PAMP(V0Est)) showed similar preload independency. Enhancing contractility increased PAMP(V0PWR) and PAMP(V0Est) from 176 +/- 52 to 394 +/- 205 W/ml x 10(4) and 145 +/- 51 to 404 +/- 261 W/ml x 10(4), respectively, accompanied by an increase of PRSW from 13.0 +/- 4.5 to 29.7 +/- 16.4 mmHg (all P <0.01). PAMP(V0PWR) and PAMP(V0Est) correlated with PRSW (r = 0.85; r = 0.77; both P <0.001). Numerical modeling confirmed the accuracy of our experimental data. Thus preload adjustment of PWR(mx) should consider a linear PWR(mx) versus EDV relationship with distinct V(0PWR). PAMP(V0PWR) is a preload-independent estimate of RV contractility that may eventually be determined noninvasively.

Animals↗

Na+/Ca2+ exchange inhibition protects the rat heart from ischemia-reperfusion injury by blocking energy-wasting processes.

We have recently reported that exposure of rat hearts to high Ca(2+) produces a Ca(2+) overload-induced contractile failure in rat hearts, which was associated with proteolysis of alpha-fodrin. We hypothesized that contractile failure after ischemia-reperfusion (I/R) is similar to that after high Ca(2+) infusion. To test this hypothesis, we investigated left ventricular (LV) mechanical work and energetics in the cross-circulated rat hearts, which were subjected to 15 min global ischemia and 60 min reperfusion. Sixty minutes after I/R, mean systolic pressure-volume area (PVA; a total mechanical energy per beat) at midrange LV volume (mLVV) (PVA(mLVV)) was significantly decreased from 5.89 +/- 1.55 to 3.83 +/- 1.16 mmHg.ml.beat(-1).g(-1) (n = 6). Mean myocardial oxygen consumption per beat (Vo(2)) intercept of (Vo(2)-PVA linear relation was significantly decreased from 0.21 +/- 0.05 to 0.15 +/- 0.03 microl O(2).beat(-1).g(-1) without change in its slope. Initial 30-min reperfusion with a Na(+)/Ca(2+) exchanger (NCX) inhibitor KB-R7943 (KBR; 10 micromol/l) significantly reduced the decrease in mean PVA(mLVV) and Vo(2) intercept (n = 6). Although Vo(2) for the Ca(2+) handling was finally decreased, it transiently but significantly increased from the control for 10-15 min after I/R. This increase in Vo(2) for the Ca(2+) handling was completely blocked by KBR, suggesting an inhibition of reverse-mode NCX by KBR. alpha-Fodrin proteolysis, which was significantly increased after I/R, was also significantly reduced by KBR. Our study shows that the contractile failure after I/R is similar to that after high Ca(2+) infusion, although the contribution of reverse-mode NCX to the contractile failure is different. An inhibition of reverse-mode NCX during initial reperfusion protects the heart against reperfusion injury.

Animals↗

Force-length relations in cardiac muscle segments.

Using a new technique that measures the length of a segment in the central region of isolated papillaries, we have determined the force-segment length relation for ferret papillary muscles at 27 degrees C. The muscles contracted under muscle length isometric (auxotonic) and segment isometric conditions in physiological solutions containing 9.0, 4.5, 2.25, and 1.125 mM Ca2+. Force-segment length relations obtained from auxotonic and segment isometric contractions were identical in a given Ca2+ concentration. Calcium variations, however, changed the position, shape, and segment length intercept of the force-segment length relation. Force, at a given segment length, increased with increasing Ca2+ up to 9.0 mM Ca2+. The force-segment length relation changed shape from linear, in 4.5 mM Ca2+, to concave in 1.125 mM Ca2+. The segment length intercept was found by extrapolation to be 68, 69, and 74% SLmax in 4.5, 2.25, and 1.125 mM Ca2+, respectively. Two passive force corrections were used to calculate the developed force-segment length relations. Assuming passive force to be related primarily to segment length yields curves that change shape with Ca2+ concentration, suggesting length-dependent activation. On the other hand, assuming passive force to be related to muscle length results in curves for different Ca2+ concentrations that are nearly vertically shifted versions of each other, suggesting the influence of internal loads.

Animals↗

Evidence and quantitation of left ventricular systolic resistance.

Instantaneous left ventricular pressure is a function of both volume (elastic behavior) and flow (resistive behavior). However, a quantitative description of ventricular resistance and its effects on ventricular performance remains to be elucidated. Accordingly, ventricular resistive behavior was studied in six isolated canine hearts. Our experimental findings indicate 1) for a specified time (ts), volume (Vs), and contractile state (CS), the ventricular pressure-flow relation was linear (r = 0.96-0.99) within the range of flows examined (0-250 ml/s); 2) ventricular resistance increased with increments in ts, Vs, and CS, whereas the zero-pressure flow intercept was invariant; 3) resistance could be uniquely quantified as a linear function of isovolumetric pressure. In six experiments, the slope of this relationship ranged from 1.1 to 2.1 X 10(-3) s/ml while the intercept did not differ from zero; and 4) end-systolic elastance, estimated from end-systolic pressure-volume data, was in substantial error under the conditions of finite (greater than 35 ml/s) end-systolic flows. Finally, the results from a computer simulation of the coupled ventricular-arterial system indicated that ventricular resistance primarily affects the pulsatile nature of aortic flow. The unique isovolumetric pressure-resistance relation suggests that the rate-limiting properties of the contractile process may be causally related to the observed ventricular resistive behavior.

Animals↗

Changes in canine cardiac function and venous return curves by the carotid baroreflex.

Venous return curves and cardiac function relationships were simultaneously determined in 10 pentobarbital-anesthetized dogs at three different isolated carotid sinus pressures. Changing carotid sinus pressure (CSP) between 50 and 200 mmHg produced large changes in the zero flow intercept of the venous return curves from 15.37 +/- 0.97 to 11.94 +/- 1.36 mmHg (P less than 0.001) but no change in slope. These changes in the intercept of the venous return curve were due to alterations in systemic vascular capacity caused by the carotid sinus baroreceptor reflex. Changes in the cardiac function curve with baroreceptor pressure were masked by concomitant changes in arterial pressure afterload; however, when arterial pressure was controlled, there was a significant change in the slope of the cardiac function curve from 60.32 +/- 26.9 to 37.06 +/- 13.31 ml X min-1 X kg-1 X mmHg-1 as CSP was changed from 50 to 200 mmHg. We conclude that changes in vascular capacity are the primary mechanism responsible for changes in cardiac output during activation of the carotid sinus baroreflex.

Animals↗

Relation between oxygen consumption and pressure-volume area of in situ dog heart.

We studied the relation between O2 consumption (VO2) and the systolic pressure-volume area (PVA) in the left ventricle of open-chest dogs. PVA and the slope (Emax) of the end-systolic pressure-volume line were determined by an abrupt occlusion of the ascending aorta. VO2 linearly correlated with PVA in control contractile state, where Emax was 15.8 +/- 4.4 (SD) mmHg/ml with intact reflexes and 11.5 +/- 1.2 mmHg/ml with blocked reflexes. Emax and the VO2 axis intercept of the VO2-PVA line were greater in the in situ heart than in the excised cross-circulated dog heart in our previous study. Enhancement of contractile state by dobutamine increased Emax by 60-80% and shifted the VO2-PVA line upward, increasing the VO2 axis intercept by 38% with intact reflexes and by 79% with blocked reflexes. The slope had a tendency to increase with dobutamine, but the increase was statistically insignificant. We conclude that PVA and Emax obtained by the aortic-occlusion method can account for changes in VO2 with changes in loading conditions and contractility in an in situ dog heart.

Animals↗

O2 consumption of dog heart under decreased coronary perfusion and propranolol.

We compared the effects of decreased coronary perfusion pressure (CP) and propranolol on the relation between left ventricular O2 consumption (VO2) and systolic pressure-volume area (PVA). PVA represents total mechanical energy generated by contraction and is the area under the end-systolic pressure-volume (PV) line and systolic PV trajectory. In excised cross-circulated dog hearts, a decrease in CP from 82 (mean) to 51 mmHg decreased ventricular contractility index Emax (slope of end-systolic PV relation) by 17% (P less than 0.05) and slightly (P less than 0.05 in 3 of 11 hearts) lowered the VO2-PVA relation in a parallel fashion. A further decrease in CP to 32 mmHg decreased Emax by 56% (P less than 0.05) and considerably (P less than 0.05) lowered the VO2-PVA relation by decreasing both the VO2-axis intercept by 26% (P less than 0.05) and the slope by 24% (P less than 0.05) from control. Propranolol decreased Emax by 48% (P less than 0.05) and the VO2-axis intercept by 25% (P less than 0.05) without changing the slope (P greater than 0.05). We attributed the different response of the VO2-PVA relation to the difference of the coronary O2 supply-demand balance between decreased CP and propranolol.

Animals↗

Effects of altered left atrial pressure on pulmonary vascular pressure-flow relationships.

We studied the effects of changes in pulmonary capillary wedge pressure (PCWP) on the slope (incremental resistance) and the extrapolated pressure intercept (PI) of the mean pulmonary artery pressure (PAP)-cardiac output (CO) relationship. Multipoint plots of PAP against CO were obtained in intact anesthetized dogs. Group 1 consisted of six dogs entirely in West zone 3 and group 2 of four dogs with mixed West zone 2-3. The four conditions studied were the following: 1) fixed low PCWP, 2) fixed high PCWP, 3) variable PCWP, and 4) time-control repeat of condition 1. The PI significantly exceeded PCWP at fixed low PCWP (group 1, 9.3 vs. 11.1 mmHg, group 2, 6.6 vs. 3.9 mmHg). PI became identical to PCWP only at fixed high PCWP in group 1 (19 +/- 2.0 vs. 19 +/- 1.1 mmHg). Thus PCWP reflects the effective vascular outflow pressure when PCWP is fixed and high. For both groups of dogs in condition 3, when PCWP was varied with CO, the slope of the resulting PAP-CO plot was significantly greater than when PCWP was constant. Also in 9 of 10 dogs, PI was less than PCWP when PCWP was varied. These findings demonstrate that when changes in PCWP are allowed to occur during the generation of a pulmonary artery pressure-flow plot, the resulting slope and intercept, as defined by a Starling resistor model, do not accurately represent the incremental resistance and outflow pressure of the pulmonary vasculature.

Analysis of Variance↗

Quantification of regional myocardial dysfunction after acute ischemic injury.

Quantification of myocardial performance after regional ischemic injury is difficult because available performance indexes are markedly dependent on concurrent load changes. To develop a more load-insensitive index of myocardial function during ischemia, eight conscious dogs were instrumented to measure left ventricular pressure with micromanometers and myocardial segment length with ultrasonic dimension transducers. Preload was varied by transient vena caval occlusion during control conditions, after 15 min of coronary occlusion, and at intervals during 24 h of reperfusion. Acute ischemia shifted the linear relationship between segmental stroke work (SW) and end-diastolic segment length (EDL) rightward, diminishing the slope and increasing the chi-intercept. Preload recruitable work area (PRWA), defined as the area under the SW-EDL curve, reflected changes in both slope and intercept. During acute ischemia, conventional performance indexes and PRWA decreased significantly and required up to 24 h of reperfusion to return to control values. Of all parameters examined, PRWA was most responsive to prolonged ischemic dysfunction after reperfusion and was insensitive to concurrent load changes. Thus PRWA provides improved precision in quantifying of myocardial dysfunction after regional ischemic injury. This parameter should be especially useful in assessing the subtle effects of acute interventions designed to modify functional recovery.

Algorithms↗

Similar normalized Emax and O2 consumption-pressure-volume area relation in rabbit and dog.

The end-systolic pressure-volume relation (ESPVR), a measure of ventricular contractile state, and systolic pressure-volume area (PVA), a primary determinant of cardiac oxygen consumption per beat (VO2), have been derived from the pressure-volume diagram of the cross-circulated dog left ventricle. The slope of the PVA-VO2 relation represents the efficiency of chemomechanical energy transduction of the contractile machinery. To see whether these relationships were similar in other animals, we studied the isovolumic ESPVR and the VO2-PVA relation in nine excised, cross-circulated rabbit left ventricles. The base-line ESPVR was linear (r = 0.94-0.99) with the slope (Emax) and volume-axis intercept (V0) equal to 83.4 +/- 18.3 mmHg/ml and 0.43 +/- 0.17 ml, respectively. When normalized for left ventricular weight, Emax (4.1 +/- 1.1 mmHg.ml-1.100 g) and V0 (8.9 +/- 3.7 ml/100 g) were similar to values reported for the dog left ventricle. The correlation between PVA and VO2 was linear (r = 0.93-1.00), and the slope (1.90 X 10(-5) +/- 0.44 X 10(-5) ml O2.mmHg-1.ml-1) and VO2-axis intercept (0.040 +/- 0.009 ml O2.beat-1.100 g-1) were similar to values found in the dog left ventricle. Hence, despite the greatly different heart size, the base-line contractile state and chemomechanical energy conversion efficiency of the excised, cross-circulated rabbit left ventricle are similar to those of the dog left ventricle.

Animals↗

Collateral influence on pressure-flow characteristics of coronary circulation.

The purpose of this study was to determine the role of the coronary collateral circulation on the shape of the coronary pressure-flow (P-F) relationship and its effects on the pressure at zero flow (PZF) or pressure intercept. We investigated the P-F characteristics of the coronary circulation under two conditions. 1) To minimize the influence of collaterals, we measured coronary flow by timed collections of coronary sinus outflow in 15 dog hearts, as perfusion pressure to all vessels was varied; 2) to maximize the effect of collaterals, we measured circumflex artery flow in six dog hearts, as perfusion pressure to only the circumflex coronary artery was varied and the pressure in the remaining vessels was maintained constant. We used an isolated heart preparation in which ventricular chamber and venous outflow pressures equalled atmospheric pressure and the vessels were maximally dilated with adenosine. In the first condition, the P-F relationship was curvilinear with a PZF of 0 mmHg; in the second condition, the P-F relationship was curvilinear with a PZF of 16 +/- 2 mmHg, and flow was retrograde at pressures below PZF. We conclude that in both conditions the curvilinearity of the coronary P-F relationship was the result of nonlinear elastic properties of blood vessels, not requiring the "waterfall" concept to be invoked, and that in the second condition the influence of collateral vessels produced the positive pressure intercept.

Animals↗