Visualization of hypoattenuation clots on unenhanced CT of the thorax.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Wide resection in 12 cases of malignant or potentially malignant lesions of the chest wall resulted in full-thickness loss of skeleton and frequently of overlying soft tissues (defect greater than or equal to 15 cm in its smallest diameter or at least 90% of the sternum resected). In reconstruction of the defect, steel bars were used to replace lost ribs and a double layer of Marlex mesh for intercostal spaces. Soft-tissue coverage and primary closure were accomplished with current plastic surgical procedures and good stability of the chest wall was achieved. Protracted respiratory support was required in only one case. Postoperative pain was managed with epidural anesthesia and routine analgesics. Functionally and cosmetically satisfactory long-term results were obtained, with no infection and no need for removal of prosthetic material. The overall 5-year and 10-year actuarial survival rates were 60% and 37.5%. If lesions are radically resectable, the extent of thoracic wall resection need not be restricted because of inability to close the defects.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
INTRODUCTION: We compared the image quality of the chest radiograph obtained with a digital selenium detector and with a conventional system and investigated the possible improvements in the digital technique resulting from kilovoltage (kV) lowering, antiscattering grid addition and image format reduction. MATERIAL AND METHODS: 150 subjects in the first series were submitted to posteroanterior chest radiography with both the selenium and the conventional systems. Image quality was compared by giving a score to the depiction of anatominal and pathologic findings. Thirty-two and 31 subjects from two other series were submitted to two digital chest radiographs each: the former at high (150) and low (90) kV, and the latter at 150 kV with the antiscattering grid and at 90 kV without the grid. Comparisons were made by choosing the better of the two images of each subjects. A score was given to the depiction quality of several difficult-to-detect findings in full-size and small-size format digital images obtained in another series of 27 subjects. RESULTS: As for anatomical detailing, digital selenium images were of much better quality than conventional images: the mean scores given by 3 observers to digital images (5.32; 5.55; 6.68) are higher than those given to the corresponding conventional images (4.49; 5.02; 5.81) and the difference is statistically significant (p < 0.001 in all cases). The advantage of digital over conventional images is also significant with reference to diagnostic confidence in the identification of pathologic findings (p < 0.001; p < 0.005; p < 0.01), but to a lessere extent (mean scores: 3.98; 4.22; 3.60 for the digital system, versus 3.43; 3.69; 3.38 for the conventional system). The digital images acquired at lower kV (90 kV) were much more frequently chosen by the two observes (87.5% and 96.8% of cases) than the images acquired at 150 kV; the entry dose at lower energies (91 muGy using an anthropomorphic phantom) is not significantly higher than the dose given at 150 kV (85 muGy). No significant difference was found in the two observers' choice between the digital images taken at 90 kV without antiscattering grid and those taken at 150 kV with the grid, the former being preferred in 38.7% and 58% of cases. The level of diagnostic confidence in the detailing of difficult-to-detect findings was slightly higher in full-size digital images (mean scores: 5.33 and 6.77) than in small-size ones (4.88 and 5.96). DISCUSSION AND CONCLUSIONS: Digital selenium images always exibit better quality than conventional images: the difference is very marked relative to anatomical detailing and not so striking, though still significant, in showing pathologic findings. Digital selenium image quality can be improved relative to the manufacturer's guidelines (150 kV exposure with no grid), by lowering the kV and adding the antiscattering grid, without increasing patient exposure too much. Digital image format reduction allows cost containment without affecting diagnostic reliability.
Explore the source record for details and available documents.
Contrast-enhanced 3D MR angiography permits comprehensive assessment of the arterial system in the chest, abdomen und lower extremities. The method combines intravenous bolus application of a non-nephrotoxic, paramagnetic, extracellular contrast agent with the acquisition of a fast 3D data set. High contrast between the vascular lumen and surrounding tissues, inherent three-dimensionality and the ability to collect image data in the chest and abdomen under apnea conditions all contribute to excellent image quality. Contrast-enhanced 3D MRA is being employed in many centers throughout the world for the evaluation of various arterial pathologies. This review provides a technical overview and critically discusses the clinical applications in the chest, abdomen and lower extremities based upon the available literature and several clinical examples.
In 55 closed injuries of the abdominal cavity and the thoracic cage 4 ruptures of the diaphragm occurred. Due to the noncharacteristic symptoms the rupture of the diaphragm is frequently mistaken. In many cases it is possible to close the rupture from the abdominal cavity.
Explore the source record for details and available documents.
Explore the source record for details and available documents.