Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 degrees C. Studies for direct bilirubin analysis show that the serum sample should be preincubated with the HCI reagent before the diazo reagent is added to minimize the false reaction with unconjugated bilirubin. With a preincubation of 15 min and a reaction interval of 15 min a 250 mg/L unconjugated bilirubin standard gave only 1 mg of apparent conjugated bilirubin per liter. Day-to-day precision studies gave CVs of 3.3% at 12.4 mg/l, 2.1% at 41.2 mg/l, and 1.0% at 197.4 mg/L for total bilirubin and 1.6% at 61.2 mg/L for direct bilirubin, the latter based on a serum pool stored at -80 degrees C. Lipemic sera caused negligible errors. Hemolysis caused slightly larger errors for total bilirubin but much smaller errors for direct bilirubin when measured at 600 nm rather than 550 nm. Comparison of results with the Rotochem (y) to those with a manual Jendrassik--Grof method (x) for total bilirubin gave y = 0.9009x - 0.04 mg/L, Sy/x = 1.3 mg/L, r = 0.9987 when different calibrators were used for each method and y = 0.9813x - 2.9 mg/L, Sy/x = 1.5 mg/L, r = 0.9997 when the same calibrators were used. For direct-bilirubin comparisons, y = 1.2762x + 0.2 mg/L, Sy/x = 1.3 mg/L, r = 0.9926.

Bilirubin↗

Isotachophoretic determination of urea-ammonium in plasma: a candidate reference method.

Separation and determination of sample constituents by capillary isotachophoresis are entirely based on physical phenomena. The method has therefore been proposed as a universal reference method for ionic constituents. The present paper shows that even neutral species can be adequately determined after suitable preceding reactions. Urea was completely hydrolysed by urease (EC 3.5.1.5) to ammonia and bicarbonate, followed by direct measurement of the ammonium ion concentration by capillary isotachophoresis. Standard Reference Material No. 912a urea (National Bureau of Standards) was used as a primary standard. The analytical linear range of the method extends to 64 mmol urea per litre. The precision of the method was in the range of 1.05-2.64% (CV) and the analytical recovery of added urea was excellent (99.4%, SD 1.13%). Further proof of accuracy was obtained by analysing the NBS human reference serum (standard reference material 909). The mean result by the capillary isotachophoretic method, 9.52 +/- 0.085 mmol/l, agrees well with the reference value, 9.64 mmol/l. The results obtained by capillary isotachophoresis showed good agreement with those obtained by the coupled-enzyme method (r = 0.995).

Ammonia↗

Special report. The Second International Anti-cardiolipin Standardization Workshop/the Kingston Anti-Phospholipid Antibody Study (KAPS) group.

Forty-three laboratories in 13 countries participated in a workshop to determine the degree of agreement between laboratories performing anticardiolipin tests. Each laboratory received freeze-dried aliquots of three samples labeled G1 (107 GPL units), G2 (20 GPL units), and G3 (6 GPL units) to be used as reference standards in the IgG assay, and three samples labeled M1 (106 MPL units), M2 (21 MPL units), and M3 (5 MPL units) as references for the IgM assay. Participating laboratories were divided into 8 groups and serum samples were exchanged between laboratories in each group. For IgG anticardiolipin, results were reported as: high, IgG positive for samples with optical absorbance readings exceeding G1; medium, IgG positive for samples with readings between G1 and G2; low, IgG positive between G2 and G3, and negative, if less than G3. In like manner, samples were defined as high-, medium-, or low-IgM positive, with reference to standards M1, M2, and M3. An index of agreement was computed to determine the degree of agreement between laboratories in each group. Interlaboratory agreement was excellent in each category assessed. For high positive and negative IgG and IgM results, the index of agreement exceeded 90%, and for medium and low positive results, agreement exceeded 75%. The overall index of agreement between laboratories exceeded 90%. The researchers conclude that the use of these six standards to obtain a semiquantitative measure of anticardiolipin positivity will enable good interlaboratory agreement in reporting anticardiolipin results.

Antibodies↗

Determination of biotin and folate in infant formula and milk by optical biosensor-based immunoassay.

Biomolecular interaction analysis was evaluated for the automated analysis of biotin- and folate-supplemented infant formulas and milk powders. The technique was configured as a biosensor-based, nonlabeled inhibition immunoassay using monoclonal antibodies raised against analyte-conjugate. Sample extraction conditions were optimized and antibodies were evaluated for cross-reactivity. Performance parameters included a quantitation range of 2-70 ng/mL, recoveries of 86-102%, agreement against assigned reference values for National Institute of Standards and Technology Standard Reference Material 1846, between-laboratory reproducibility relative standard deviation of 9.1% for biotin and 8.1% for folate, respectively, and equivalence against reference microbiological assay methods for both analytes.

Animals↗

Reduction of interlaboratory variability in flow cytometric immunophenotyping by standardization of instrument set-up and calibration, and standard list mode data analysis.

Two workshops addressed the question to which degree standardization of instrument set-up and calibration, and standard list mode data analysis would reduce interlaboratory variability of flow cytometric results on prestained peripheral blood mononuclear cells (PBMC). Standard instrument set-up included uniform positioning of the "windows of analysis" for the forward and sideward light scatter and fluorescence (FL) 1 (i.e., fluorescein isothiocyanate [FITC]) and 2 (i.e., phycoerythrin [PE]) parameters. Reference standards and PBMC, double-stained with FITC- and PE-conjugated monoclonal antibodies covering a wide range of FL intensities and coexpression patterns, were sent out to 25 laboratories in Workshop 1 and to 35 laboratories in Workshop 2 with the following requests: a) to set up instruments according to local and standard protocols, b) to acquire list mode data on the PBMC with both instrument settings, and c) to analyze both datasets according to local protocols. Standard analysis of the list mode data acquired with uniform instrument settings was performed centrally using so-called "latent class model" software (Van Putten et al., Cytometry 14:86-96, 1993). This software provides an automated, "no-gating" analytical method of lymphocyte immunophenotypes and employs fixed FL marker settings as defined prior to each analytical run. In Workshop 1, these markers were set in identical histogram channels for all instruments based on results obtained with a reference instrument. Standard analysis of list mode data acquired after uniform instrument set-up led only to a 13% reduction of interlaboratory variability of results as compared to data analysis using local protocols. The standard protocol for instrument set-up led to uniform positioning of relatively strong FL signals but variable positioning of unstained cells on the FL histogram scales. Hence, standard FL marker settings were inappropriate for some instruments. Therefore, instrument responses to FITC and PE signals in Workshop 2 were calibrated using microbeads labeled with FITC or PE in a range of predefined FL intensities expressed in MESF units (molecules of equivalent soluble fluorochrome). That approach allowed the positioning of the FL markers for the standard analysis on the basis of identical FL1 and FL2 intensities, expressed in MESF units, for all instruments. Standard analysis of list mode data acquired after uniform instrument set-up and calibrated FL marker settings led to a 43% reduction of interlaboratory variability as compared to data analysis to local protocols. We conclude that standard list mode data analysis using fixed FL marker settings reduces the interlaboratory variability of flow cytometric results on prestained PBMC, provided that the instruments have been set up in a uniform way and that FL markers have been standardized on the basis of calibration of each instrument's response to the corresponding FL signals.

Antigens, CD↗

Fingerprint chromatogram analysis of Pseudostellaria heterophylla (Miq.) Pax root by high performance liquid chromatography.

A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the fingerprinting of extracts from the root of Pseudostellaria heterophylla (Miq.) Pax. HPLC with gradient elution was performed on an authentic reference standard of powdered P. heterophylla (Miq.) Pax root and 11 plant samples of the root were collected from different geographic locations. The HPLC chromatograms have been standardized through the selection and identification of reference peaks and the normalization of retention times and peak intensities of all the common peaks. The standardized HPLC fingerprints show high stability and reproducibility, and thus can be used effectively for the screening analysis or quality assessment of the root or its derived products. Similarity index calculations based on cosine angle values or correlation methods have been performed on the HPLC fingerprints. As a group, the fingerprints of the P. heterophylla (Miq.) Pax samples studied are highly correlated with closely similar fingerprints. Within the group, the samples can be further divided into subgroups based on hierarchical clustering analysis (HCA). Sample grouping based on HCA coincides nicely with those based on the geographical origins of the samples. The HPLC fingerprinting techniques thus have high potential in authentication or source-tracing types of applications.

Caryophyllaceae↗

Plants as biomarkers for monitoring heavy metal contaminants on landfill sites using sequential extraction and inductively coupled plasma atomic emission spectrophotometry (ICP-AES).

There have been a number of studies investigating metal uptake in plants on contaminated landfill sites, but little on their role as biomarkers to identify metal mobility for continuous monitoring purposes. Vegetation can be used as a biomonitor of site pollution, by identifying the mobilisation of heavy metals and by providing an understanding of their bioavailability. Plants selected were the common nettle (Uritica Dioica), bramble (Rubus Fruticosa) and sycamore (Acer Pseudoplatanus). A study of the soil fractionation was made to investigate the soil properties that are likely to influence metal mobility and a correlation exercise was undertaken to investigate if variations in concentration of metals in vegetation can reflect variations in concentration of the metals in soil. The soil was digested using aqua regia in a microwave closed vessel. The vegetation was digested using both microwave and a hydrogen peroxide-nitric acid mixture, refluxed on a heating block and a comparison made. The certified reference materials (CRMs) used were Standard Reference Material (SRM) 1547, peach leaves for vegetation (NIST) and for soil CRM 143R, sewage sludge-amended soil (BCR). The relative standard deviations (RSDs) were 2-6% for the analyses. Our findings show evidence of phytoextraction by some plants, (especially bramble and nettle), with certain plants, (sycamore) exhibiting signs of phytostabilisation. The evidence suggests that there is a degree of selectivity in metal uptake and partitioning within the plant compartments. It was also possible to correlate mobility phases of certain metals (Pb, Cu and Zn) using the soil and plant record. Zn and Cu exhibited the greatest potential to migrate from the roots to the leaves, with Pb found principally in the roots of ground vegetation. Our results suggest that analysis of bramble leaves, nettle leaves and roots can be used to monitor the mobility of Pb in the soil with nettle, bramble and sycamore leaves to monitor Cu and Zn.

Biomarkers↗

Optimization of the USP assay for hyaluronidase.

The current USP XXII assay for hyaluronidase (EC 3.2.1.35, HAse) determines activity indirectly by measuring the amount of undegraded hyaluronic acid (HA) substrate remaining after the enzyme is allowed to react with the HA for 30 min at 37 degrees C. To be acceptable as a substrate, the HA must pass a USP suitability test. In this study, seven HA samples, which differed in their anatomical origin, their commercial supplier, and their chondroitin sulphate content, were tested as substrates. One of these did not pass the USP suitability test and therefore would not be an officially acceptable substrate; however, it was carried through the investigation along with the others in order to demonstrate its effect on the analysis. All seven HAs were used as substrates to assay testicular hyaluronidases from three different suppliers. The standard by which the other hyaluronidase activities were measured was USP hyaluronidase reference standard. The activity values calculated for a particular hyaluronidase differed significantly depending on which HA was used as substrate in its assay. Optimal results, as judged on the bases of initial purity, suitability for the assay, linearity of the standard curve, and per cent relative standard deviation of the measured activity, were obtained with a HA substrate derived from vitreous humour.

Animals↗

MR imaging of the articular cartilage of the knee with arthroscopy as gold standard: assessment of methodological quality of clinical studies.

The purpose of this study was to assess the methodological quality of articles addressing the value of MR imaging of the knee cartilage with arthroscopy as a standard. Relevant papers were selected after Medline review (MEDLINE database search including the terms "cartilage" "knee", "MR" and "arthroscopy"). Two observers reviewed independently 29 selected articles to determine how each study had met 15 individual standards that had been previously developed to assess the methodological quality of clinical investigations. The following criteria were met in variable percentage of articles including adequate definition of purpose (100%), statistical analysis (90%), avoidance of verification bias (86%), patient population description (83%), reference standard (79%), review bias (79%), study design (66%), inclusion criteria (41%) and method of analysis (41.5%), avoidance of diagnostic-review bias (24%), exclusion criteria (21%), indeterminate examination results (17%), analysis criteria (14%), interobserver reliability (14%) and intraobserver reliability (7%). The assessment of the methodological quality of clinical investigations addressing the value of MR imaging in the evaluation of the articular cartilage of the knee with arthroscopy as the standard of reference demonstrated that several standards were rarely met in the literature. Efforts should be made to rely on clearly defined lesion criteria and to determine reliability of the observations.

Arthroscopy↗

Criteria for determining purity of Fusarium mycotoxins.

Physical and chemical properties that may be used to determine the purity of several Fusarium mycotoxins have been investigated. A combination of analytical procedures, which include high performance thin-layer chromatography (HPTLC), liquid chromatography (LC), gas chromatography (GC), gas chromatography/mass spectrometry (GC/MS), ultraviolet spectrometry (UV), and nuclear magnetic resonance (NMR) spectrometry have been used to examine mycotoxin standards obtained from commercial sources and from laboratory fermentations. Results of this investigation indicate that commercially available standards are greater than 90% pure, but the label weight of purchased reference standards in individual containers should be verified. Mycotoxin standards, determined to be greater than 98% pure by HPTLC, LC, and GC/MS, were examined by UV spectrometry and the coefficients of extinction were determined. An interlaboratory study, involving 5 collaborators who determined coefficients of extinction (in methanol) for identical samples, gave the following results: alpha-zearalenol (lambda 236 = 28 538 +/- 558); beta-zearalenol (lambda 238 = 24 963 +/- 747); deoxynivalenol (lambda 219 = 6395 +/- 349, lot 1), (6020 +/- 228, lot 2); and T-2 toxin (lambda 202 = 3681 +/- 255). UV maxima and coefficients of extinction are also reported for HT-2 toxin (lambda 202 = 1959), diacetoxyscirpenol (lambda 203 = 2487), neosolaniol (lambda 203 = 2644), nivalenol (lambda 220 = 5142), and fusarenon-X (lambda 217 = 5997).

Chromatography, Gas↗

Assignment of weight-based immunoglobulin G1 (IgG1) and IgG2 units in antipneumococcal reference serum lot 89-S(F) for pneumococcal polysaccharide serotypes 1, 4, 5, 7F, 9V, and 18C.

Weight-based assignments for immunoglobulin G1 (IgG1) and IgG2 subclass antibodies to Streptococcus pneumoniae capsular polysaccharides (PnPs) in antipneumococcal standard reference serum lot 89-S (lot 89-S), also known as lot 89-SF, have been determined for serotypes 1, 4, 5, 7F, 9V, and 18C. This extends the usefulness of lot 89-S beyond the IgG1 and IgG2 subclass assignments for serotypes 3, 6B, 14, 19F, and 23F made previously (A. Soininen, H. Kayhty, I. Seppala, and T. Wuorimaa, Clin. Diagn. Lab. Immunol. 5:561-566, 1998) to cover 11 major serotypes associated with the highest percentage of pneumococcal disease worldwide. A method of equivalence of absorbances in enzyme immunosorbent assays was used to determine the IgG1 and IgG2 antibody concentrations for the additional serotypes in lot 89-S, based on the subclass values previously assigned for PnPs serotypes 6B, 14, and 23F. This cross-standardization method assures consistency with previous antibody assignments in that reference serum. The newly assigned subclass values for serotype 9V, and previously assigned values for serotype 14, were used to quantitate PnPs antibodies in sera from adult and pediatric subjects immunized with a pneumococcal conjugate vaccine. There was a predominance of IgG1 anti-PnPs antibodies in pediatric sera and IgG2 anti-PnPs antibodies in the adult sera. The IgG1 and IgG2 subclass assignments for the 11 PnPs serotypes in antipneumococcal standard reference serum lot 89-S are useful for quantitating and characterizing immune responses to pneumococcal infection and vaccination regimens.

Adult↗

Lactate-to-pyruvate or pyruvate-to-lactate assay for lactate dehydrogenase: a re-examination.

The pyruvate-to-lactate assay for determining lactate dehydrogenase (EC 1.1.1.27) can now yield linearity equal to or better than that obtained by the lactate-to-pyruvate assay. In addition, there are significant advantages to the pyruvate-to-lactate reaction: (a) a greater change in absorbance per unit time, which allows more accurate spectrophotometric readout; (b) lower reactant concentrations are required, which substantially reduces the cost per assay; (c) solid reagents are used to prepare the assay solution; and (d) reagent solutions are more stable. However, impurities present in commercial NADH preparations may substantially affect measured lactated dehydrogenase activities; therefore, a Standard Reference Material for NADH is being developed for issuance by the National Bureau of Standards.

L-Lactate Dehydrogenase↗

Determination of polychlorinated biphenyls in biota samples using simultaneous pressurized liquid extraction and purification.

In order to reduce time and cost of analysis, a new pressurised liquid extraction method that automatically and rapidly achieves quantitative and selective (i.e., lipid-free) extraction of polychlorinated biphenyls (PCBs) in biota tissues was optimized. It consists of on-line clean-up by inclusion of sorbents in the extraction cell. The freeze-dried sample is dispersed with Florisil and loaded in the extraction cell containing an extra amount of Florisil. The extraction is performed under mild conditions using 55 ml of a dichloromethane-pentane (15:85) mixture, a temperature of 40 degrees C, a static extraction time of 10 min and two extraction cycles. The Florisil retains coextracted lipids from the matrix, and the extract, after pre-concentration, is clean enough for direct injection into GC-MS and GC-electron-capture detection (ECD). Quantitative recoveries (from 90 to 106%) are obtained for both native and spiked PCB congeners in samples with a high lipidic content (up to 42% dry mass, in spoonbill eggs). The reproducibility of replicate extractions was better than 11% relative standard deviation. Method detection limits were in the ranges of 0.001-0.004 and 0.002-0.07 ng g(-1) dry mass for GC-ECD and GC-MS-MS, respectively. The method was validated using the standard reference material SRM 2974 (a mussel tissue) from the US National Institute of Standards and Technology, compared to Soxhlet and matrix solid-phase dispersion extraction methods, and used to evaluate the contamination by PCBs in bivalves from South of Spain.

Animals↗

Ossification of femoral head in infancy. I. Normal standards.

Observations made in 455 Malmö infants with assumedly normal ossification of the femoral heads were used for establishing reference standards for the age at onset of the ossification and for the size of the ossification centers according to sex and age.

Age Factors↗

Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging: comparison with standard MR imaging and correlation with arthroscopy.

OBJECTIVE: A preliminary study was done to prospectively compare fat-suppressed three-dimensional spoiled gradient-echo (3D SPGR) MR imaging with standard MR imaging for detection of defects in the hyaline cartilage of the knee, using arthroscopy as the reference standard. SUBJECTS AND METHODS: We studied 43 consecutive patients referred by two orthopedic surgeons for MR imaging of the knee. Twelve had arthroscopic correlation; they formed the basis of our study. Hyaline cartilage was imaged with a fat-suppressed 3D SPGR sequence with previously determined optimal imaging parameters. Our standard MR imaging study consisted of two-dimensional coronal T1-weighted spin-echo, sagittal dual-echo T2-weighted spin-echo, and axial multiplanar gradient-echo sequences. With arthroscopy as the reference standard, sensitivity and specificity of fat-suppressed 3D SPGR and standard MR images for detecting cartilage tears were determined by articular surface (eight surfaces in each patient: medial and lateral patellar facets, trochlear facets, femoral condyles, and tibial plateaus). Statistically significant differences in sensitivity and specificity were determined. RESULTS: Arthroscopy showed 15 cartilage defects in seven patients. The fat-suppressed 3D SPGR images had higher sensitivity (93%) than the standard MR images (53%, p = .03). Specificity was 94% for the fat-suppressed 3D SPGR images compared with 93% for the standard MR images (p > .05). The five false-positive articular surfaces on fat-suppressed 3D SPGR images were from focal signal change within the substance of the cartilage without a contour defect. Smoothly contoured thinning and loss of the trilaminar appearance of the hyaline cartilage at the lateral femoral notch was shown in all subjects and was considered a normal finding. CONCLUSION: Fat-suppressed 3D SPGR imaging is more sensitive than standard MR imaging for the detection of abnormalities of the hyaline cartilage in the knee. Routine use of this technique may strengthen the role of MR imaging for noninvasive evaluation of internal derangements of the knee.

Adolescent↗

Niacin. II: Identification of isonicotinic acid in niacin by liquid chromatography with diode array detection.

Isonicotinic acid impurity in bulk niacin was detected and identified by comparison with a reference material by liquid chromatography with a diode array detector. The niacin was dissolved in dilute hydrochloric acid and chromatographed on an amine column with a mobile phase of methanol and water acidified with formic acid. Isonicotinic acid has a relative retention time of 1.5 compared with niacin (nicotinic acid), and the wavelengths of maximum ultraviolet (UV) absorbance for isonicotinic acid and niacin are 270 and 260 nm, respectively. The amount of impurity found in the niacin sample was 0.3%. Twelve formulations, including sustained-release products, one bulk material, and the United States Pharmacopoeia (USP) reference standard were tested. The impurity was detected in only the bulk and USP reference material samples.

Chromatography, Liquid↗

Cross-sectional growth standards for captive baboons: I. Organ weight by chronological age.

We present the first cross-sectional organ weight reference standards for captive baboons (Papio hamadryas). Organ weight data were obtained from necropsy reports for 634 healthy, pedigreed, captive female and male baboons. From summary statistics we calculated and fit cross-sectional, sex-specific percentile curves for: adrenals, brain, eyes, heart, kidneys, liver plus gall bladder, lungs, pancreas, pituitary gland, spleen, and thyroid gland in two year age class intervals and summary statistics by sex for each organ in one year age classes.

Animals↗

Serum zinc levels in healthy subjects from southeastern Spain.

The serum zinc (Zn) concentrations of 80 healthy subjects (48 male, 32 female) from southeastern Spain were determined by atomic absorption spectrometry. The samples were digested by heating in a 4:1 mixture of nitric and perchloric acids. The concentration of Zn was determined against a Contox Trace Metal Serum Control Panel A standard reference. Zn concentrations in the standard were found to be 2.332+/-0.489 mg/L, with a mean recovery of 102.7%. In the serum samples, the relative standard deviation was <6% for the range of concentrations determined: 0.420-1.540 mg/L for women (mean value 0.947+/-0.265 mg/L) and 0.490-1.480 mg/L for men (mean value 0.951+/-0.243 mg/L). In healthy subjects, no statistically significant differences were observed in the Zn levels with respect to their sex (p > 0.05) or the location where they lived (mountainous vs coastal zones). It is concluded that the dietary Zn intake and Zn status for healthy adults in this region of Spain are within normal values.

Adolescent↗