Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Failure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

Secondary aortoenteric fistula: contemporary outcome with use of extraanatomic bypass and infected graft excision.

PURPOSE: The standard treatment for secondary aortoenteric fistula (SAEF) has been infected graft removal (IGR) and extraanatomic bypass (EAB), an approach criticized for its high rate of death, amputation, and disruption of aortic closure. Recently, graft excision and in situ graft replacement has been proposed as a safer treatment alternative. Because the current outcome that can be achieved by use of the standard treatment of SAEF has really not been established, we reviewed the records of 33 patients treated for SAEF at our institution during a contemporary time interval (1980 to 1992). METHODS: Thirteen patients (39.4%) were admitted with evidence of gastrointestinal bleeding and infection, whereas nine (27.3%) only had bleeding, 10 (30.3%) only had signs of infection, and one SAEF was entirely occult (graft thrombosis). Four patients required emergency operation. The fistula type was anastomotic in 13 (39.4%) patients, paraprosthetic in 15 (45.5%), and not specified in 4 cases. Thirty-two patients underwent EAB followed immediately by IGR (n = 16, 48.5%) or followed by IGR after a short interval, averaging 3.9 days (n = 16, 48.5%). The final patient underwent IGR, followed by EAB. RESULTS: Follow-up on 31 patients (93.9%) averaged 4.4 +/- 3.7 years. There were nine deaths (27.3%) resulting from the SAEF, six perioperative and three late. Three patients (9.1%) had disrupted aortic closure. There were four amputations in three patients (9.1%), two perioperative and two late. Late EAB infection occurred in five patients (15.2%), leading to one death and one amputation. EAB failure occurred in six patients, two during operation and four late, leading to one amputation. The cumulative cure rate for this SAEF group was 70% at 3 years and thereafter. Compared with our earlier SAEF experience, this is a decline of 21% in the mortality rate, 19% in aortic disruption, and 27% in limb loss. CONCLUSIONS: We conclude that outcome reports based on SAEF series extending over long time intervals do not accurately represent the results that are currently achieved with standard SAEF treatment with use of EAB plus IGR. This improved outcome is attributed to wide debridement of infected tissue beds, reduced intervals of lower body ischemia, and advances in perioperative management. To determine whether any new treatment approach actually offers improved outcome in the management of SAEF, comparison with EAB plus IGR should be limited to patients treated within the last decade at most.

Aged↗

The long-term outcome of artificial urinary sphincters.

PURPOSE: We reviewed the outcome of artificial urinary sphincters inserted more than 10 years ago. MATERIALS AND METHODS: We analyzed the records of 100 patients and mailed a questionnaire to those without recent followup. RESULTS: Overall 84 patients were continent, including 36 with the original artificial urinary sphincter in place who were dry at a median followup of 11 years and 27 in whom the device was successfully replaced due to mechanical failure who were previously continent for a median of 7 years. In 21 patients it was removed due to infection or erosion and reimplantation was successful 3 to 6 months later or they remained dry without another artificial urinary sphincter. Of the male patients with a bulbar and bladder neck sphincter 92% and 84%, respectively, were continent at 10 years as well as 73% of the females. Device survival was 66% at 10 years. Overall 37% of the prostheses were removed due to infection or erosion in the 10-year period with the highest risk in females (56%) and lowest in males with a bulbar sphincter (23%). CONCLUSIONS: The artificial urinary sphincter is effective long-term treatment for incontinence in male patients. In female patients the risk of erosion is high, although overall long-term continence is satisfactory.

Adolescent↗

Nasal defects and osseointegrated implants: UCLA experience.

A clinical study of 23 craniofacial implants placed in 11 nasal defects was conducted over a 7-year period. Implant-retained nasal prostheses were fabricated, implant success rate was determined, and the soft tissue responses were recorded at 6-month intervals. No data were gathered on two implants because of patient death. The implant success rate was 71.4% (15/21) but varied significantly by anatomic site. The implant success rate in the glabella was 0% (0/4), whereas the success rate in the anterior nasal floor was 88.1% (15/17). All implant failures occurred within the first year of loading. A five-point scale was used to record the health of the peri-implant soft tissues, and the patients were followed up from 6 to 74 months. The unit of measure was a visit/site, and a unit was assigned for each instance an implant site was evaluated. Evaluations were conducted at 6-month intervals for a total of 76 visit/sites for the study period. The results revealed that 85.5% (65/76) of the visit/sites demonstrated an absence of inflammation; 10.5% (8/76) of the visit/sites demonstrated slight redness; 1.3% (1/76) demonstrated peri-implant red and moist tissues; 2.6% (2/76) demonstrated granulation tissue associated with the implants; and 0% (0/76) demonstrated infection of the peri-implant soft tissues. Severe soft tissue reactions around implants placed in the anterior nasal floor are rare.

Aged↗

Experience with the Mitroflow aortic bioprosthesis.

From October 1985 to May 1990, the Mitroflow bovine pericardial valve was placed in the aortic position in 168 patients (97 men, 71 women) with a mean age of 69.7 years. Eighty-nine patients had isolated aortic valve replacement, and 79 had aortic valve replacement and additional procedures. Follow-up over 7 1/2 years includes 781 patient years (426 for isolated aortic valve replacement). Mean follow-up time is 56 months. Peak-to-peak gradients (in millimeters of mercury) measured in the intraoperative period averaged 11.0 +/- 8.7, 11.8 +/- 10.8, and 8.6 +/- 8.2 for 19 mm, 21 mm, and 23 mm valves, respectively. Hospital mortality was 7.3% (14 patients); all deaths were non-valve related. Late mortality of 20.1% in 31 patients resulted from cardiac failure (n = 8), sepsis (n = 4), valve reoperation (n = 1), non-cardiac causes (n = 15) and sudden, unknown causes (n = 3). Fifteen thromboembolic episodes occurred, but only three late thromboembolic episodes occurred in isolated aortic valve replacement without other risk factors. Four early and four late episodes of endocarditis occurred. Seven patients had clinical valve dysfunction, and five others required reoperation for structural deterioration, with one death. At 94 months, overall survival was 64% +/- 5%. Freedom from thromboembolic episode was 87% +/- 3% and 90% +/- 4% for isolated aortic valve replacement. Freedom from combined reoperation or clinical dysfunction was 75% +/- 8%: 64% +/- 15% for those under 70 years of age, and 87% +/- 7% for those 70 years of age and older. The valve has favorable hemodynamics. Durability begins to decline during the sixth year after implantation, possibly at a slower rate in patients older than 70 years of age.

Adolescent↗

Survival analysis of the Harris-Galante I acetabular cup.

We reviewed 264 consecutive primary total hip replacements in 244 patients in which the Harris-Galante I porous-coated acetabular component had been used. The mean follow-up was 95 months (69 to 132). In 221 arthroplasties a 32 mm ceramic head had been used, and in the other 43 one of cobalt-chrome alloy. There were 124 women and 120 men with a mean age at operation of 56.8 years (21 to 83). Survival analysis of the acetabular components was performed using the following definitions of failure: 1) infection; 2) removal because of aseptic loosening; 3) removal for any cause; and 4) a worst-case analysis including removal of the cup or infection or loss to follow-up. Two well-fixed cups had been removed because of deep infection and three, similarly sound cups had been exchanged at the time of femoral revision. None of the acetabular components had required revision for aseptic loosening. After 11 years survival was 97.7% using the worst-case criterion. Radiological analysis of 187 acetabular components at a mean of 82 months (41 to 132) revealed no case of aseptic loosening. Pelvic osteolysis was seen in only one patient, but was not progressive and showed signs of regression. The results using these acetabular components are encouraging but the need for regular follow-up remains since complications such as significant wear of the liner, massive osteolysis of the pelvis, aseptic loosening and late infection may increase in the second decade.

Acetabulum↗

Failure of a carbon fiber implant. A case report.

STUDY DESIGN: Case report. OBJECTIVES: Failure of a carbon fiber implant. SUMMARY OF BACKGROUND DATA: To simplify the procedure of posterior lumbar interbody fusion, a carbon-fiber-reinforced polymer implant has been developed. The implant has ridges to resist retropulsion, struts to support weight, and a hollow area to allow packing of autologous bone graft. So far, no complications have been reported from the use of carbon implant as a fusion aid in spine surgery. METHODS: A patient with postoperative infection has been followed with computed tomography images and histologic examination from a reoperation. RESULTS: An entire nonunion across the width of the disc space and a clearly broken cage was visualized with computed tomography. The spinal canal was explored during a reoperation and the tissue surrounding the dura and nerves were all black. Microscopic examination showed a large quantity of carbon particulate debris. The authors have operated on approximately 100 patients so far and no other carbon cage has broken, to their knowledge. CONCLUSIONS: Carbon cages can break if a nonunion occurs and as a result free carbon particles move out to the spinal canal.

Adult↗

Preoperative evaluations in revision total knee arthroplasty.

UNLABELLED: There are many causes of total knee arthroplasty failure, and an accurate preoperative diagnosis is essential to optimize the results of revision surgery. We discuss our standard pre-operative evaluation routine and we retrospectively reviewed the last 295 patients who underwent revision total knee arthroplasty to establish the clinical value of the most commonly performed investigations used to diagnose sepsis. Routinely performed preoperative investigations include erythrocyte sedimentation rate, C-reactive protein, microbiology, bacteriology cultures of preoperative knee aspirations, and intraoperative tissue bacteriology cultures. Each investigation was compared with the reason for revision (eg, septic or aseptic) to establish the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of each. 79 cases (26.8%) were revised for infection. Of the investigations, the ESR had a sensitivity of 0.63, a specificity of 0.55, a positive predictive value of 0.39, a negative predictive value of 0.77, and an accuracy of 0.57. The respective values for C-reactive protein were 0.6, 0.63, 0.45, 0.76, and 0.62, and 0.53, 0.94, 0.75, 0.85, and 0.83 for intraoperative tissue culture. There was no preoperative investigation accurate enough to be solely relied on for diagnosing infection. We believe that clinical findings and the routine use of simple tests such as C-reactive protein, ESR, and knee aspiration yield predictable results. LEVEL OF EVIDENCE: Prognostic study, level II-1 (retrospective study). See the Guidelines for Authors for a complete description of levels of evidence.

Arthroplasty, Replacement, Knee↗

Treatment of an early implant failure according to the principles of guided tissue regeneration (GTR).

The present case report demonstrates the application of guided tissue regeneration (GTR) in combination with antimicrobial therapy for the treatment of an early implant failure. This treatment approach both prevented further loss of bone as well as led to the regeneration of lost bone. By means of color-converted digital subtraction images, remodelling of the tissues adjacent to the defect was documented as early as one month postsurgically. The images demonstrated "bone-fill" in the apical portion of the defect and resorptive changes at the bone crest. This case report demonstrates that combined regenerative and antimicrobial therapy may be a successful treatment approach restoring osseointegration of dental implants following loss of bone due to infection. Continuously increasing bone-fill inside the defect was documented when comparing the radiograph obtained immediately before the GTR procedure and at months 1, 2, 4, 5 and 6 of the healing period, respectively. Clinical measurement obtained at the time of the surgery and at the time of the membrane removal confirmed the radiographic evidence of bone-fill by demonstrating new tissue resistant to probing in close contact to the implant surface at the site of the previous defect. Antimicrobial therapy included an antibiotic regimen during the 1st month of healing as well as topical rinses with an antiseptic (chlorhexidine) over the entire healing period of 6 months. As a result of this treatment approach, the implant was saved and could be used as an abutment for a bridge reconstruction.

Alveolar Bone Loss↗

Customised hinged knee replacements as a salvage procedure for failed total knee arthroplasty.

BACKGROUND: Failure of knee arthroplasty can lead to significant pain and functional disability. In a small number of patients with fracture, sepsis or massive bone loss they are considered for arthrodesis or above knee amputation. The purpose of this study was to investigate the results and complications of using customised hinged knee replacements in their place. METHODS: Since 1993, 30 of the 280 (10.7%) revision knee replacements in the Avon Orthopaedic Centre, Bristol have used Endo customised hinged knee prostheses (21 rotating, nine fixed) for salvage of limb threatening situations in elderly patients. Surgical indications were 22 low periprosthetic fractures (with or without aseptic loosening), five massive aseptic osteolyses, and three deep infections. RESULTS: The mean length of post-operative hospital stay was just 14.6 days and all patients were discharged walking with aids. At follow up (mean 3.0 years, range 0.5-9.3 years) nine patients had died with their prostheses in situ and functioning. Six patients developed deep sepsis, two of which underwent above knee amputation, and two had received further surgery for septic problems. Two patients required further surgery for prosthetic disarticulation and one patient had successful on table vascular repair. Twenty-five patients had mid- or long- term follow up. Their mean American Knee scores (AKS) were 69.8 for knee and 35.6 for function (maximum 100), with mean total knee flexion 83 degrees. Mean Oxford knee scores (OKS) and WOMAC scores (both scored between 12 and 60 with low score indicating less difficulties) were 34.0 and 30.5, respectively. CONCLUSIONS: Customised hinge revision knee replacements gave rapid rehabilitation and hospital discharge. Complications were high but at mid- and long-term review, no prostheses had failed from an aseptic cause and most of the knees of this challenging group were providing both stability and flexion.

Aged↗

Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty.

BACKGROUND: First-generation cementless modular cups reproducibly achieved fixation to bone but were associated with unacceptable rates of pelvic osteolysis and mechanical failure. Consequently, second-generation cups were developed with shells that had a limited number of holes (or no holes) as well as improved locking mechanisms, a polished inner surface, and increased conformity with the liner. The purpose of the present study was to evaluate the clinical and radiographic results associated with the use of a second-generation acetabular component for primary total hip arthroplasty. METHODS: Two hundred and ninety-seven patients underwent 335 consecutive primary total hip arthroplasties that were performed by a single surgeon with a second-generation modular acetabular component. All cups were implanted with a press-fit technique. Ten patients were lost to follow-up, and sixteen died from unrelated causes. The remaining 271 patients (308 hips) were followed clinically (with the Hospital for Special Surgery hip-scoring system) and radiographically for four to seven years. RESULTS: One cup was revised because of aseptic loosening. There were seven additional revisions: five were performed because of aseptic loosening of the stem with a well-fixed cup, and two were performed because of deep infection. Among the 271 patients who were alive at the time of the last follow-up, 266 (98%) had retention of the cup and 264 (97%) had retention of both components with a good or excellent clinical result. In the group of 229 patients (262 hips) with complete radiographic follow-up, 259 cups were well fixed and the average wear rate (for the 246 hips for which this rate could be calculated) was 0.09 mm/yr. Osteolysis was detected in twelve hips (5%) and was associated with male gender (p = 0.001) and the annual wear rate (p = 0.004). The extent of calcar resorption was also associated with the annual wear rate (p < 0.001). CONCLUSIONS: This second-generation acetabular cup design predictably achieved bone fixation and was associated with low rates of revision for loosening and osteolysis after intermediate-term follow-up.

Adult↗

Outcomes analysis of revision total shoulder replacement.

BACKGROUND: The number of total shoulder arthroplasties has increased exponentially over the last ten years, creating a more prominent role for revision shoulder arthroplasty in the future. The main reasons for failure of shoulder arthroplasty can be classified as soft-tissue deficiencies, osseous deficiencies, component wear, or infection. We hypothesized that, despite appropriate surgical techniques, the outcome of revision total shoulder replacement can be predicted on the basis of the indication for the revision procedure. METHODS: We conducted a retrospective review of seventy-eight shoulders that had undergone revision shoulder arthroplasty. The shoulders were divided into two categories: (1) those with osseous or component-related problems and (2) those with soft-tissue deficiency. Category 1 consisted of four cohorts of shoulders: twenty-two treated with revision of the glenoid component, sixteen treated with conversion of a hemiarthroplasty to a total shoulder arthroplasty because of glenoid arthrosis, eight treated with revision of the humeral stem, and four treated for a periprosthetic fracture. Category 2 consisted of five cohorts of shoulders: ten treated with rotator cuff repair following total shoulder replacement, four with a failed tuberosity reconstruction, four with cuff tear arthropathy, five with instability, and five with infection. Patients were evaluated with the UCLA subjective outcome instrument, the L'Insalata shoulder questionnaire, and a subjective satisfaction scale (maximum score of 5 points). RESULTS: The average UCLA score was 21.4 points and the average L'Insalata score was 68.73 points for the seventy-eight shoulders that were analyzed. The average score on the subjective satisfaction questionnaire was 2.91 points. According to the UCLA scores, twenty-four revisions were considered to have had an excellent result; fifteen, a good result; twenty-four, a fair result; and fifteen, a poor result. The average scores for the category-1 shoulders were significantly better than those for the category-2 shoulders (p < 0.05). Of the different types of operations, revision or implantation of a glenoid component and open reduction and internal fixation of a periprosthetic fracture provided the best outcomes. Tuberosity reconstruction, hemiarthroplasty for treatment of cuff tear arthropathy, and revision due to infection had uniformly poor outcomes. CONCLUSIONS: In general, these results indicate that the outcome of revision shoulder arthroplasty can be predicted on the basis of the indication for the procedure. Component revisions, excluding humeral head revision for salvage, provide the best results, whereas soft-tissue reconstructions can be expected to yield poorer results overall. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions to Authors for a complete description of levels of evidence.

Adult↗