Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Filtration”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

Membrane filtration of two sulphonamides in tertiary effluents and subsequent adsorption on activated carbon.

The adsorption behaviour of two polar organic micropollutants (N-n-butylbenzenesulphonamide and sulphmethoxazole) onto powdered activated carbon (PAC) under competitive conditions prior to and after filtration with a tight ultrafiltration membrane was examined. The sulphonamides were spiked into microfiltered tertiary municipal effluent in microg L(-1) quantities. Ultrafiltration of these effluents resulted in better adsorbability for both the micropollutants and the background organic matter in the permeates compared to the feed waters. This behaviour seems to be caused by a reduced blocking of micropores by lower concentrations of high molecular weight compounds in membrane filtrates. A combined treatment of ultrafiltration prior to adsorption can therefore reduce the carbon demand for potentially harmful micropollutants in effluents.

Adsorption↗

Fluorescent dye labeled bacteriophages--a new tracer for the investigation of viral transport in porous media: 2. Studies of deep-bed filtration.

Viral transport in deep-bed sand filters was studied by a new method that enables rapid and simple quantitation of labeled viruses. The residence time distribution (RTD) of viruses in the bed was compared to the RTD of a fluorescein dye under conditions that simulate a filter run. The characteristics of the RTD curves for the free dye and the labeled bacteriophages followed very different trends during the filter run. While the retention time of free dye was practically independent of the filtration stage, the average retention time of the labeled bacteriophage depended in a non-linear way on filtration time. Average virus retention time as well as virus-removal efficiency were minimal at the ripening stage, increased during the operational stage and then decreased again towards the turbidity breakthrough stage. This complex trend reflects two opposing mechanisms that dominate the behavior of the filter. During the ripening stage the accumulation of the kaolin-alum material in the filter increases the adsorption surface area and retards virus mobility. After sufficient kaolin-alum deposit is accumulated in the filter, aging and densification of the alum deposit induces size exclusion phenomenon giving faster apparent mobility of viruses in the filter bed.

Bacteriophages↗

Soil phosphorus fractions in solution: influence of fertiliser and manure, filtration and method of determination.

This study investigated the forms of soil P released to solution, accuracy of their determination, and influence of colloids on P sorption/desorption dynamics. A Hagerstown silt loam, amended with dairy and poultry manure or superphosphate at five rates (0, 25, 50, 100, and 200 kg P ha(-1)), was extracted at two soil:solution ratios (1:5 and 1:100) and filtered at three pore sizes (0.8, 0.45, and 0.22 microm). Results showed that relative to the proportion of dissolved organic P (DOP, determined as the difference between total dissolved P [TDP] and P detected by ion chromatography), DRP increased with amendment rate. Relative to Mehlich-3 extractable P, DRP exhibited a power relationship with a much greater potential for soil P release at concentrations in excess of ca. 50 mg Mehlich-3 P kg(-1). Concentrations of DRP, determined by the acid molybdate method, were on average 12.5% greater than P detected by ion chromatography indicating P was solubilised during colorimetric determination. A linear relationship was found between total Al and DRP, which could indicate acid mediated hydrolysis of A1-humic-P substances, although acid mediated desorption of P from colloids cannot be discounted. No difference in solubilised P was found between solutions filtered at 0.22 and 0.45 microm, but was found between 0.8 microm and smaller filter sizes. Organic P extracted from manured soils was more recalcitrant than that extracted from soils amended with superphosphate, the later attributed to its accumulation in more labile pools. The sorption/desorption of P by colloids in solution were greatly affected by the rate of amendment and the soil:solution extraction ratio. More P was sorbed by superphosphate solutions compared to dairy manure amended soil solutions and was attributed to the saturation of colloidal P sorption sites by organic matter. In order to minimise the effects of colloids on P dynamics and the potential for hydrolysis in solution, filtration to at least 0.45 microm is required. However, soils with a lesser aggregate stability may require additional filtration.

Absorption↗

Bradykinin generation in RC-MAP during storage at 4 degrees C and leukocyte removal filtration.

We investigated contact system activation in red cell concentrate in mannitol-adenine-phosphate (MAP) solution (RC-MAP) during storage and leukocyte removal filtration. The contact system activation was assessed in terms of bradykinin (BK) generation. The BK level in the RC-MAP transiently but significantly (p < 0.05) increased at 7 to 14 days of storage. Moreover, the BK level in 21-day-stored RC-MAP was approximately 10 times higher than that in other blood components. The BK level in mannitol-containing MAP solutions, but not that in mannitol-free MAP solution, saline or whole blood, increased during storage. The plasma angiotensin-converting enzyme (ACE) activity decreased significantly only in mannitol-containing MAP solutions. These findings suggest that mannitol plays an essential role in the increase in BK level in RC-MAP. Furthermore, the BK level in RC-MAP increased 10 minutes after the start of filtration through a negatively charged filter, either a BPF-4 or an RN-40, and reached a maximum of 6,000 pg/ml. Hypotensive reactions are rare in RC-MAP transfusion in comparison to their incidence in platelet concentrate (PC) transfusion in spite of the higher BK level in RC-MAP than in PC. Therefore, BK generation in various blood components is not likely to be the main cause of hypotensive reactions. However, the level of BK in RC-MAP is sufficiently high to cause site pain. Further investigation on the clinical significance of a high BK level in blood components is necessary.

Adenine↗

Effect of dissolved organic matter and bacteria on contaminant transport in riverbank filtration.

A mathematical model for the transport of hydrophobic organic contaminants in an aquifer under simplistic riverbank filtration conditions is developed. The model considers a situation where contaminants are present together with dissolved organic matter (DOM) and bacteria. The aquifer is conceptualized as a four-phase system: two mobile colloidal phases, an aqueous phase, and a stationary solid phase. An equilibrium approach is used to describe the interactions of contaminants with DOM, bacteria, and solid matrix. The model is composed of bacterial transport equation and contaminant transport equation. Numerical simulations are performed to examine the contaminant transport behavior in the presence of DOM and bacteria. The simulation results illustrate that contaminant transport is enhanced markedly in the presence of DOM and bacteria, and the impact of DOM on contaminant mobility is greater than that of bacteria under examined conditions. Sensitivity analysis demonstrates that the model is sensitive to changes of three lumped parameters: K+1 (total affinity of stationary solid phase to contaminants), K+2 (total affinity of DOM to contaminants), and K+3 (total affinity of bacteria to contaminants). In a situation where contaminants exist simultaneously with DOM and bacteria, contaminant transport is mainly affected by a ratio of K+1/K+2/K+3, which can vary with changes of equilibrium distribution coefficient of contaminants and/or colloidal concentrations. In riverbank filtration, the influence of DOM and bacteria on the transport behavior of contaminants should be accounted to accurately predict the contaminant mobility.

Bacteria↗

Following an initial decline, glomerular filtration rate stabilizes in heart transplant patients on chronic cyclosporine.

We previously reported that heart transplant patients given cyclosporine for more than 2 years (short-term evaluation) had severe renal lesions and markedly reduced glomerular filtration rate and renal plasma flow (Kidney Int 40:243-250, 1991). We report the analysis of renal function in the same patients after 3 additional years of follow-up (long-term evaluation) while they continued to take cyclosporine. Since the previous evaluation, the dose of cyclosporine was adjusted to maintain stable trough levels and antihypertensive therapy was unchanged. The mean time-averaged dose of cyclosporine during the follow-up was 4.5 +/- 2.1 mg/kg/d. The systolic blood pressure at long-term evaluation (146 +/- 16 mm Hg) was increased (P < 0.05) compared with that at short-term evaluation (140 +/- 13 mm Hg), whereas diastolic blood pressure (long-term 91 +/- 9 mm Hg v short-term 88 +/- 9 mm Hg) and mean blood pressure (long-term 110 +/- 12 mm Hg v short-term 108 +/- 11 mm Hg) did not change significantly. Serum creatinine concentrations at long-term (1.7 +/- 0.3 mg/dL) and at short-term (1.7 +/- 0.4 mg/dL) evaluations were similar. At long-term evaluation the renal plasma flow (300 +/- 64 mL/min/1.73 m2) was not decreased compared with that at short-term evaluation (325 +/- 94 mL/min/1.73 m2), while the glomerular filtration rate increased significantly (43 +/- 15 mL/min/1.73 m2 v 36 +/- 8 mL/min/1.73 m2, respectively; P < 0.05). None of the patients became proteinuric after short-term evaluation; in those patients who were already proteinuric, urinary protein excretion did not increase over time.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Long-term treatment with either enalapril or nitrendipine stabilizes albuminuria and increases glomerular filtration rate in non-insulin-dependent diabetic patients.

The effect of short- (98 days) and long-term (1 year) treatment with nitrendipine (10 to 40 mg/d) and enalapril (5 to 20 mg/d) on kidney function was studied prospectively in a parallel group design in 16 microalbuminuric non-insulin-dependent diabetic patients with mild hypertension and biopsy-proven diabetic glomerulopathy. At the end of the short-term treatment period diastolic blood pressure significantly decreased from 95.4 +/- 2.5 mm Hg to 83.5 +/- 3.5 mm Hg (P < 0.001) in the nitrendipine group and from 96.7 +/- 2.5 to 86.7 +/- 5.6 mm Hg (P < 0.001) in the enalapril group. Both overnight urinary albumin excretion rate and albumin fractional clearance tended to increase in the nitrendipine group and to decrease in the enalapril group, whereas the glomerular filtration rate and the renal plasma flow were similar to baseline in both study groups. At the end of the long-term treatment period diastolic blood pressure significantly decreased from 95.4 +/- 2.5 mm Hg to 86.0 +/- 6 mm Hg (P < 0.005) in the nitrendipine group and from 96.7 +/- 2.1 to 90.8 +/- 4.3 mm Hg (P < 0.05) in the enalapril group. Overnight urinary albumin excretion and albumin fractional clearance were similar to baseline in both study groups. The glomerular filtration rate significantly increased from 70.2 +/- 14.2 to 96.8 +/- 20.4 (P < 0.05) in the nitrendipine group and from 58.9 +/- 10.7 to 78.5 +/- 11.0 (P < 0.05) in the enalapril group. The renal plasma flow also significantly increased from 456.6 +/- 165.3 to 597.2 +/- 178.9 (P < 0.01) in the nitrendipine group.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The plasma creatinine concentration is not an accurate reflection of the glomerular filtration rate in stable renal transplant patients receiving cyclosporine.

We studied 31 stable renal cadaver kidney transplant patients receiving cyclosporine (CyA) and prednisone for immunosuppression to determine what reduction in true glomerular filtration rate (GFR) was reflected by their mild elevation in plasma creatinine concentration (1.8 +/- 0.11 mg/dL). We measured both the creatinine clearance (60 +/- 4.32 mL/min/1.73 m2) and the true GFR using Technetium 99m-DTPA (44 +/- 2.72 mL/min/1.73 m2). The creatinine clearance overestimated true GRF by a mean of 38%, indicating that this percentage of creatinine reached the urine by tubular secretion rather than glomerular filtration. A similar degree of overestimation was found in a separate group of 14 patients receiving imuran for immunosuppression. In 23 patients receiving CyA in whom the serum creatinine concentration was less than 2.0 mg/dL, the mean DTPA clearance was 49.5 +/- 2.83 mL/min/1.73 m2. In stable renal transplant patients receiving CyA, a serum creatinine concentration at, or close to, the upper limit of the normal range may reflect markedly impaired renal function.

Adult↗

[Initial personal results of a technic of removing leukocytes by filtration on cotton fibers (Imugard Ig 500, Terumo)].

The technical parameters of blood filtration through cotton Imugard IG 500 filters were evaluated. Sixty units of red cell concentrates were filtered. The mean value of the residual leukocytes indicated a leukocyte depletion greater than 98%, disregarding the unit age and the filtration temperature. The number of residual leukocytes was below 1 X 10(8) in 94% of the filtered units and less than 0.3 X 10(8) in 68%. The number of residual platelets was less than 1 X 10(10) in 92% of these units.

Blood Platelets↗

An investigation of the fluidity of concentration polarisation layers in crossflow membrane filtration of an oil-water emulsion using chemical shift selective flow imaging.

A chemical shift selective NMR flow imaging sequence using stimulated echoes for data acquisition is presented. The sequence was tested using a 20% (vol/vol) oil-water emulsion formed from a soluble cutting oil, which was passed through a simple flow phantom to yield two-dimensional velocity distribution maps of the oil droplets and of the water separately. It was then used to investigate the fluidity of concentration polarisation layers formed from the oil droplets during crossflow membrane filtration of a 5% (vol/vol) emulsion of the same cutting oil. A simple membrane filtration module was used for this purpose, with the feedstock emulsion fed into the lumen of a single tubular membrane at a trans-membrane pressure difference P approximately 70 kPa and crossflow Reynolds number, Re, in the range 100-1000. The results confirm a net axial flow rate < 7.5 microns/s (half digital resolution in the velocity dimension) for the oil polarisation layer. Under these conditions, the upper limit for oil flow tangential to the membrane in the polarised layer is less than 15% of the convective flow of oil towards the membrane.

Emulsions↗

Glomerular filtration and volume regulation in gravid animal models.

The gestational increase in glomerular filtration rate that occurs in the normal rat is exclusively the result of an increase in renal plasma flow and there is no sustained increase in glomerular capillary blood pressure during a normal pregnancy. The factor or factors that initiate the gestational renal vasodilatation (and plasma volume expansion) are maternal, not fetoplacental in origin. The precise nature of the initiating factors has not yet been defined, although it is unlikely that the gestational plasma volume expansion can be the sole cause of the increased glomerular filtration rate seen in pregnancy. A number of vasoactive hormones are activated in pregnancy but as yet no clear candidate has emerged as 'the renal vasodilator'. Preliminary evidence suggests that nitric oxide may play an important role in gestational vasodilatation. The normal kidney in pregnancy exhibits substantial renal reserve to amino acid infusion and unimpaired autoregulatory ability despite being already vasodilated by the gestational stimulus. There are marked and sometimes contradictory changes in the various volume sensing and control systems in pregnancy. In general, the sensors perceiving and controlling intravascular volume are reset during a normal pregnancy to enable to mother to accommodate the increased plasma volume without provoking a natriuretic response. Whether the expanded plasma volume of pregnancy is perceived as normal or underfilled is not clear at this time and may vary according to the volume regulatory system. Repetitive pregnancies do not have any cumulative, long-term deleterious effects on renal function, when the underlying function is normal, when it has been compromised by removal of renal mass or during chronic systemic hypertension in the spontaneously hypertensive rat. In the short term, pregnancy does not worsen kidney function when underlying glomerular damage is due to immune stimuli, ablation of renal mass or gentamicin, or in the spontaneously hypertensive rat. Therefore, the chronic renal vasodilatation of pregnancy does not appear to be a damaging entity, unlike other states of low preglomerular arteriolar resistance, studied in the male rat. When pregnancy is superimposed on Adriamycin nephrosis or chronic blockade of nitric oxide, hypertension occurs and renal function declines. In both situations endothelial damage/dysfunction occurs, as is also seen in pre-eclampsia. Further study of the effects of pregnancy in animal models of endothelial dysfunction will prove rewarding.

Animals↗

[Leukocyte removal in a closed system of human red-cell concentrates: a technic coupled with the automated extraction of the buffy coat using a sterile connector from a filtration kit].

A technique, integrally run in a closed system, for leucocyte depletion of human red cell concentrates is described. It associates two complementary processes: buffy-coat removal and filtration. The first step is carried out with an automated system for blood component preparation (Compomat, NPBI); its efficiency is improved by a custom made blood collection set with ACD anticoagulant solution in the primary bag. The second step is simplified by a filtration kit requiring only one sterile connection for operation (SCD 312, Dupont de Nemours) and allowing a standardised rinsing of the filter. Quality control of 33 units so prepared shows principally: --an intensive leuko-depletion (4 logs) enabling leukocyte contamination to be kept below 10(6) per unit; --a moderate red cells loss (15 ml for the first step and 20 ml for the second one). This technique provides a permanently available and very pure blood component. Moreover it offers new potential for standardisation and mastery of quality control.

Blood Cell Count↗

Filtration induces changes in activity states and leucocyte populations.

The distribution of leucocyte subpopulations in platelet concentrates (PC) derived from pre-storage filtered platelet-rich plasma (PRP), the cell suspension obtained by reverse filter washing and the post-filtered PC, were monitored by immunophenotyping analysis using CD3, CD20 and CD33. Leucocyte activation analysis with the CD11b marker revealed that this molecule is up regulated in neutrophils taken from the filter. This, together with the loss of cell viability during the enrichment process, suggests that contact with the filter matrix and processing and storage of samples containing leucocytes may lead to activation and loss of leucocyte viability. These changes were found to be more pronounced in less stable myeloid cells and account for the differences reported among various authors which in some cases related to operational conditions such as the enrichment process used and the length of time between filtration and analysis of samples. Finally, statistical analysis of the results obtained by immunophenotypic studies indicate that post-filter samples (S) contain significantly higher numbers of CD33+ myeloid cells when compared to (PF) the pre-filter samples (65.03%+/-12.6 and 24.56%+/-14.73, p<0.0000), with a decrease in T cells (50.72%+/-14.80 in PF and 24.05+/-9.48 in the cell suspension (S), p<0.0007) and B cells (14.96+/-9.31 in PF and 9.9+/-5.22 in S, p<0.201). A new strategy for assessing the influence of the filtration process on residual leucocyte activation and viability is described. This has direct relevance to collection, processing, storage and quality monitoring of PC.

Antigens, CD↗

Membrane filtration media for the enumeration of coliform organisms and Escherichia coli in water: comparison of Tergitol 7 and lauryl sulphate with Teepol 610.

In a multi-laboratory trial with the membrane filtration technique, three surfactants--Teepol 610 (T610), Tergitol 7 (T7) and sodium lauryl sulphate (LS)--were compared in media for the enumeration of coliform organisms and Escherichia coli in water. A total of 179 samples of water (87 raw and 92 marginally chlorinated) were examined for colony counts of coliform organisms, and 185 water samples (94 raw and 91 marginally chlorinated) for E. coli. Slight differences in the confirmed colony counts between the three media were noted, but few of these were observed consistently in every laboratory. In most laboratories, T7 gave slightly higher counts of E. coli than LS with chlorinated waters; a higher incidence of false-positive results for E. coli at 44 degrees C was also noted with T7. As there were no outstanding differences in the trial, sodium lauryl sulphate, which is chemically defined, cheap and readily available, is therefore recommended for use at a concentration of 0 . 1% instead of Teepol 610 in the standard medium for the enumeration of coliform organisms and E. coli in water by the membrane filtration technique.

Bacteriological Techniques↗

Legionella pneumophila: comparison of isolation from water specimens by centrifugation and filtration.

A comparison was made between membrane filtration and centrifugation for the isolation of Legionella pneumophila from seeded water samples. Using samples of varying concentration, the optimum speed and time of centrifugation were determined and the relationship between the number of organisms present in the water and the proportion recovered was examined. Following this, sequential routine environmental waters were filtered and centrifuged in parallel. Centrifugation and filtration using nitrocellulose filters were found to be comparable. The optimum speed and time of centrifugation was approximately 6000 g for 10 min. There was a constant proportion of viable organisms recovered irrespective of the concentration in the unspun samples.

Centrifugation↗

Rapid filtration analysis of nucleotide binding to Na,K-ATPase.

Transient kinetic analysis of nucleotide binding to pig kidney Na,K-ATPase using a rapid filtration technique shows that the interaction between nucleotide and enzyme apparently follows simple first-order kinetics both for ATP in the absence of Mg(2+) and for ADP in the presence or absence of Mg(2+). Rapid filtration experiments with Na,K-ATPase membrane sheets may nevertheless suffer from a problem of accessibility for a fraction of the ATPase binding sites. Accordingly, we estimate from these data that for ATP binding in the absence of Mg(2+) and the presence of 35 mM Na(+) at pH 7.0 at 20 degrees C, the bimolecular binding rate constant k(on) is about 30 microM(-1) x s(-1) and the dissociation rate constant k(off) is about 8 s(-1). In the presence of 10 mM Mg(2+), the binding rate constant is the same as that in the absence of Mg(2+). For ADP or MgADP the binding rate constant is about 20 microM(-1) x s(-1) and the dissociation rate constant is about 12 s(-1). Results of rapid-mixing stopped-flow experiments with the fluorescent dye eosin are also consistent with a one-step mechanism of binding of eosin to the ATPase nucleotide site. The implication of these results is that nucleotide binding to Na,K-ATPase both in the absence and presence of Mg(2+) appears to be a single-step event, at least on the time scale accessible in these experiments.

Adenosine Diphosphate↗

Continuous ethanol production from concentrated wood hydrolysates in an internal membrane-filtration bioreactor.

Continuous culture for the production of ethanol from wood hydrolysate was carried out in an internal membrane-filtration bioreactor. The hydrolysate medium was sterilized at a relatively low temperature of 60 degrees C with the intention of reducing the formation of inhibitory compounds during the sterilization. The maximum ethanol concentration and productivity obtained in this study were 76.9 g/L and 16.9 g/L-h, respectively, which were much higher than those (57.2-67 g/L and 0.3-1.0 g/L-h) obtained in batch cultures using hydrolysate media sterilized at 60 degrees C. The productivity was also found to be much higher than that (6.7 g/L-h) obtained in a continuous cell retention culture using a wood hydrolysate sterilized at 121 degrees C. These results show that the internal membrane-filtration bioreactor in combination with low-temperature sterilization could be very effective for ethanol production from wood hydrolysate.

Bioreactors↗

Polynuclear aromatic hydrocarbon and particulate emissions from two-stage combustion of polystyrene: the effects of the secondary furnace (afterburner) temperature and soot filtration.

Laboratory experiments were conducted in a two-stage horizontal muffle furnace in order to monitor emissions from batch combustion of polystyrene (PS) and identify conditions that minimize them. PS is a dominant component of municipal and hospital waste streams. Bench-scale combustion of small samples (0.5 g) of shredded styrofoam cups was conducted in air, using an electrically heated horizontal muffle furnace, kept at Tgas = 1000 degrees C. Upon devolatilization, combustion of the polymer took place in a diffusion flame over the sample. The gaseous combustion products were mixed with additional air in a venturi and were channeled to a secondary muffle furnace (afterburner) kept at Tgas = 900-1100 degrees C; residence time therein varied between 0.6 and 0.8 s. At the exits of the primary and the secondary furnace the emissions of CO, CO2, O2, NOx, particulates as well as volatile and semivolatile hydrocarbons, such as polycyclic aromatic hydrocarbons (PAH), were monitored. Online analyzers, gravimetric techniques, and gas chromatography coupled to mass spectrometry (GC-MS) were used. Experiments were also conducted with a high-temperature barrier filter, placed just before the exit of the primary furnace to prevent the particulates from entering into the secondary furnace. Results demonstrated the beneficial effect of the afterburner in reducing PAH concentrations, including those of mutagenic species such as benzo[a]pyrene. Concentrations of individual PAH exhibited a pronounced after burner temperature dependence, typically ranging from a small decrease at 900 degrees C to a larger degree of consumption at 1100 degrees C. Consumption of PAH was observed to be the dominant feature at 900 degrees C, while significant quantities of benzene and some of its derivatives, captured by means of carbosieve/Carbotrap adsorbents, were formed in the afterburner at a temperature of 1000 degrees C. In the primary furnace, about 30% of the mass of the initial polystyrene was converted into soot, while the total mass of PAH represented about 3% of the initial mass of combustible. The afterburner reduced the particulate (soot) emissions by only 20-30%, which indicates that once soot is formed its destruction is rather difficult because its oxidation kinetics are slow undertypical furnace conditions. Moreover, increasing the afterburnertemperature resulted in an increasing trend of soot emissions therefrom, which might indicate competition between soot oxidation and formation, with some additional formation occurring at the higher temperatures. Contrary to the limited effect of the afterburner, high-temperature filtration of the combustion effluent prior to the exit of the primary furnace allowed for effective soot oxidation inside of the ceramic filter. Filtration drastically reduced soot emissions, by more than 90%. Limited soot formation in the afterburner was again observed with increasing temperatures. The yields of both CO and CO2 were largely unaffected by the temperature of the afterburner but increased at the presence of the filter indicating oxidation therein. A previously developed kinetic model was used to identify major chemical reaction pathways involving PAH in the afterburner. The experimental data at the exit of the primary furnace was used as input to these model computations. A first evaluation of the predictive capability of the model was conducted for the case with ceramic filter and a temperature of 900 degrees C. The afterburner was approximated as a plug-flow reactor, and model predictions at a residence time of 0.8 s were compared to experimental data collected at its exit. In agreement with the experimental PAH concentration, only a minor impact of the afterburner treatment was observed for most species at 900 degrees C. OH was deduced to be the major reactant with a mole fraction about 4 orders of magnitudes higher than that of hydrogen radicals. Evidence for the need of further work on the quantitative assessment of oxidation of PAH and their radicals is given.

Air Pollutants↗