Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

[Studies of dental methacrylic resin. (Part. 6) Adhesive strength of self-curing methacrylic resin to polymethylmetacrylates with various cross-linking density. (author's transl)].

The adhesive property of dental acrylic resin to resin teeth and denture base resins is an important property, in the case of preperating, repairing and rebasing denture. Then, as models of denture base resin and resin tooth, heat-curing methacrylic resins which were cross-linked with three kinds of polyethylene glycol dimethacrylate, i.e., EDMA, tri-EDMA, nona-EDMA, were prepared, and the tensile adhesive strengths of self-curing methacrylic resin to them were examined. The results were as follows. 1) The tensile adhesive strength under the dry condition was dependent on cross-linking density of adherent resin, and decreased according to the increase of concentration of cross-linking agent added in adherent resin. 2) The greater the number of chain members of cross-linking agent used to adherent resin was, the higher the adhesive strength was. In particular, the adhesive strength to adherent resin added with nona-EDMA in concentration from 16.7 to 30 mole%, agreed with the tensile strength of adherent resin itself indicating a favourable adhesion. 3) The adhesive strengths under the wet condition, that is, when specimens were immersed in water at 37 degrees C for 21 days, decreased from 30 to 50%, compared with that under the dry condition.

Acrylic Resins↗

Pin hole nasal prosthesis: a clinical report.

Atrophic rhinitis is a debilitating nasal mucosal disease characterized by foul-smelling discharge of crusts and enlargement of the nasal cavity. Numerous surgical and nonsurgical methods have been advocated for its treatment. This article describes a noninvasive technique for partial occlusion of the dilated nasal cavity in a patient with atrophic rhinitis by use of a pinhole nasal prosthesis made from clear acrylic resin.

Acrylic Resins↗

Bacterial growth on dental restorative materials in mucosal contact.

Test specimens of amalgam, gold, porcelain, heat-cured acrylic resin, and human enamel were made to fit into cavities prepared in acrylic pontics of maxillary bridges. One side of the specimen was in close contact with the mucosa. Plaque was allowed to accumulate on the specimens for 27 to 48 days, and adherent bacteria were then quantified by cultivation on selective and non-selective media. The inflammatory status of the mucosa overlying the specimens were monitored by exudation measurements. Lower total numbers of bacteria were recovered from acrylic specimens than from the other materials used, including enamel. There were also significant subject differences in bacterial recovery. Test specimens in contact with inflamed mucosa yielded less total numbers of bacteria, but higher numbers of Streptococcus mutans, than did specimens exposed to mucosa with no or negligible exudation.

Acrylic Resins↗

[Prosthetic problems after excisional surgery].

The authors present a few cases maxillary and facial reconstruction with restoration of the esthetic appearance, mastication and phonation, using the obturator muscles and prostheses made up of acrylic resin and silicone elastomers.

Acrylic Resins↗

Experimental fixation of bone cement and composite resins to bone.

The aim of this study was to ascertain whether the use of liquid acrylic resin or NeoCryl XK-53 acrylic emulsion or etching of the bone surface with phosphoric acid or the application of both these methods would improve the bonding of CMW bone cement or Concise and Silar composite resin to bone. The test materials were applied to fresh cortical bovine bone. Their bonding capacity was measured by the Instron Universal Testing Machine. The surfaces of the test materials and the bone surfaces were examined by means of optic microscope or scanning electron microscope. The bonding strength of the bone cement and composite resins as such were found to be of the same magnitude. A three- to five-fold improvement was obtained with liquid acrylic intermediary material. Acid etching impaired the bonding.

Acrylic Resins↗

Effect of microwave disinfection procedures on torsional bond strengths of two hard chairside denture reline materials.

PURPOSE: This study evaluated the potential effects of denture base resin water storage time and an effective denture disinfection method (microwave irradiation at 650 W for 6 minutes) on the torsional bond strength between two hard chairside reline resins (GC Reline and New Truliner) and one heat-polymerizing denture base acrylic resin (Lucitone 199). MATERIALS AND METHODS: Cylindrical (30 x 3.9 mm) denture base specimens (n= 160) were stored in water at 37 degrees C (2 or 30 days) before bonding. A section (3.0 mm) was removed from the center of the specimens, surfaces prepared, and the reline materials packed into the space. After polymerization, specimens were divided into four groups (n= 10): Group 1 (G1)--tests performed after bonding; Group 2 (G2)--specimens immersed in water (200 ml) and irradiated twice (650 W for 6 minutes); Group 3 (G3)--specimens irradiated daily until seven cycles of disinfection; Group 4 (G4)-specimens immersed in water (37 degrees C) for 7 days. Specimens were submitted to a torsional test (0.1 Nm/min), and the torsional strengths (MPa) and the mode of failure were recorded. Data from each reline material were analyzed by a two-way analysis of variance, followed by Neuman-Keuls test (p= 0.05). RESULTS: For both Lucitone 199 water storage periods, before bonding to GC Reline resin, the mean torsional strengths of G2 (2 days--138 MPa; 30 days--132 MPa), G3 (2 days--126 MPa; 30 days--130 MPa), and G4 (2 days--130 MPa; 30 days--137 MPa) were significantly higher (p < 0.05) than G1 (2 days--108 MPa; 30 days--115 MPa). Similar results were found for Lucitone 199 specimens bonded to New Truliner resin, with G1 specimens (2 days-73 MPa; 30 days--71 MPa) exhibiting significantly lower mean torsional bond strength (p < 0.05) than G2 (2 day--86 MPa; 30 days--90 MPa), G3 (2 days--82 MPa; 30 days--82 MPa), and G4 specimens (2 days--78 MPa; 30 days--79 MPa). The adhesion of both materials was not affected by water storage time of Lucitone 199 (p > 0.05). GC reline showed a mixed mode of failure (adhesive/cohesive) and New Truliner failed adhesively. CONCLUSIONS: Up to seven microwave disinfection cycles did not decrease the torsional bond strengths between the hard reline resins, GC Reline and New Truliner to the denture base resin Lucitone 199. The effect of additional disinfection cycles on reline material may be clinically significant and requires further study.

Acrylic Resins↗

Effect of microwave disinfection on the flexural strength of hard chairside reline resins.

OBJECTIVES: This study investigated the effect of microwave disinfection (650W/6 min) on the flexural strength of five hard chairside reline resins (Kooliner, Duraliner II, Tokuso Rebase Fast, Ufi Gel Hard, New Truliner) and one denture base resin (Lucitone 550). METHODS: Thirty-two specimens (3.3x10x64 mm) from each acrylic resin were produced and divided into four groups of eight specimens each. The flexural test was performed after polymerization (G1), after two cycles of microwave disinfection (G2), after 7 days storage in water at 37 degrees C (G3) and after seven cycles of microwave disinfection (G4). Specimens from group G4 were microwaved daily being stored in water at 37 degrees C between exposures. The specimens were placed in three-point bend fixture in a MTS machine and loaded until failure. The flexural values (MPa) were submitted to ANOVA and Tukey's test (p=0.05). RESULTS: Two cycles of microwave disinfection promoted a significant increase in flexural strength for materials Kooliner and Lucitone 550. After seven cycles of microwave disinfection, materials Kooliner and New Truliner showed a significant increase (p<0.05) in flexural values. The flexural strength of the material Tokuso Rebase was not significantly affected by microwave irradiation. Seven cycles of microwave disinfection resulted in a significant decrease in the flexural strength of material Duraliner II. Material Ufi Gel Hard was the only resin detrimentally affected by microwave disinfection after two and seven cycles. CONCLUSIONS: Microwave disinfection did not adversely affect the flexural strength of all tested materials with the exception of material Ufi Gel Hard.

Acrylic Resins↗

Treating the cracked tooth with a full crown.

Twenty-eight teeth diagnosed as having a crack were immediately treated with full coverage acrylic resin crowns. Twenty-five of these teeth became asymptomatic after full coverage acrylic crown placement and continued to be asymptomatic one year after restoration.

Acrylic Resins↗

Changes in gloss after simulated generalized wear of composite resins.

STATEMENT OF PROBLEM: Generalized wear of composite resins in the noncontact area may result in changes of gloss, which can influence esthetics of restorations. PURPOSE: The purpose of this study was to determine the changes in gloss of composite resins after generalized wear simulation. Surface roughness and amount of wear were measured for comparison. MATERIAL AND METHODS: Generalized wear simulation was performed with a wear tester for 400,000 cycles with 6 composite resins (Estelite Sigma, Esthet X improved, Filtek Supreme, Heliomolar, Renamel Microfill, and Tetric-Ceram). Composite resin was placed into a mold (8 mm in diameter, 3 mm in depth) in an acrylic resin block, and 8 specimens were prepared per group. A flat-planed stylus made with polyacetal was loaded perpendicularly. Gloss was measured after every 100,000 cycles with a glossmeter in gloss units (GU). Average surface roughness (R(a)) of each specimen before and after 400,000 cycles of wear was determined. The amount of wear was measured with a 3-dimensional profilometer. Changes in gloss were analyzed by repeated-measures analysis of variance, and mean values were compared by Fisher's PLSD interval (alpha=.05). RESULTS: Gloss was influenced by the number of wear cycles and the composite resin, and there was a significant interaction (P=.000) between the number of wear cycles and the brand of composite resin. There were no significant correlations between the wear depth and the gloss or changes in gloss after 400,000 cycles. CONCLUSION: Generalized wear simulation for approximately 3 years of clinical use resulted in gloss changes of 36 to 64 GU, and maximum wear depth was in the range of 35 to 75 mum. Change in gloss varied among the composite resins, but average surface roughness was not influenced by the various composite resins.

Acrylic Resins↗

An easy and versatile embedding method for transverse sections.

In several research areas, transverse sections are indispensable for studying structural aspects of specimens. However, the oriented embedding of small cylindrical samples can become problematic, especially when transverse sections at right angles to the main axis of the object are desired. Here, we describe an easy and low-cost technique for oriented embedding of small (psi < 500 micro m) as well as of larger specimens (psi > 500 micro m). The usefulness of the technique is demonstrated for roots and stamens of Arabidopsis thaliana and for adventitious roots of Asplenium demerkense, as examples of small and larger cylindrical samples, respectively. Furthermore, several types of resin (glycol methacrylate, epoxy and acrylic resins) were successfully tested, showing the applicability of the technique for light and electron microscopy and for immunolocalizations. In conclusion, the principle of the technique can be extended to several resins and a wide variety of specimen types, such as stems, leaves and textile fibres. The originality of the technique lies in its simplicity combined with its high efficiency to produce well-oriented transverse sections.

Arabidopsis↗

Contact dermatitis to incontinency pads in a (meth)acrylate allergic patient.

BACKGROUND: The authors report a case of a 47-year-old woman who suffered a severe allergic contact dermatitis (ACD) in the vulvar area after using Poise thin incontinency pads. She had a past history of ACD after the use of sculptured acrylic nails and after the installation of a dental crown. OBJECTIVE: The aim of this report is to show the spectrum of (meth)acrylate allergy in one individual. METHODS: Patch testing of moistened inner and outer aspect of the pad was performed. We also patch tested with the North American Contact Dermatitis Group series of 50 allergens, the dentistry series, various catalysts and inhibitors used in acrylic resin systems, and some epoxy acrylates. RESULTS: Positive ACD reaction occurred to both sides of the pad, with the inner aspect being stronger than the outer aspect. There were also multiple (meth)acrylate allergies. CONCLUSION: This case shows a new potential source of allergy to (meth)acrylates.

Dermatitis, Allergic Contact↗

[The influence of bonding strength of denture soft reline resin by different surface treatments].

PURPOSE: This study evaluated the influence of bonding strength of heat-polymerized denture soft reline resin by 4 different surface treatments bonded to denture base resin. METHODS: Denture base resin (8mm in diameter and 15 mm in length) were fabricated from heat-polymerized acrylic resin (Densply). And heat-polymerized denture soft reline resin disks (Physio liner) were also made (4 mm thick and 10 mm diameter). Two denture base resins were bonded to the denture reline resin disk at the centure on the two sides of the disk. All the specimen were divided into 4 groups (n=10) with 3 different surface treatments: (1) no treatment(control), (2) sandblasted, (3) surface liner application, (4) surface liner application+sandblasted. Bond strength (MPa) was measured by tension bond testing at a 12.7 mm/min speed until the soft reline resin debonded from the base resin. Data were statistically analyzed by SPSS 10.0 software package for ANOVA. RESULTS: The mean bond strengths of group 1, 2, 3, 4 were 3.518, 2.834, 4.077, 3.852MPa respectively. The bonding strength of all the three groups showed significant difference (P<0.0014). The group with surface liner application showed significantly highest bonding strength, while the group with sandblasted showed the lowest bonding strength. CONCLUSIONS: The use of surface liner can significantly improve the bonding strength of heat-polymerized denture soft reline resin to the denture base resin, while the bonding strength decreased after using sandblasting.

Acrylic Resins↗

An evaluation of microwave-polymerized resin bases for removable partial dentures.

PURPOSE: The hardness, porosity, and adaptation of removable partial dentures fabricated with one heat-polymerized denture base resin and two resins designed for microwave polymerization were evaluated. MATERIALS AND METHODS: Five prostheses were evaluated for each resin. Adaptation of the denture bases to the master cast was evaluated by spatial orientation and mean weight of residual impression material. The prostheses were than embedded in epoxy resin and sectioned for evaluation of resin hardness (Knoop hardness) and microporosity. RESULTS: There were no significant differences in the adaptation of the acrylic resin bases for Acron MC and Ch Lucitone. There was no significant difference in the mean Knoop hardness values for any of the resin bases near and away from the metal. None of the denture bases showed porosity greater than 100 microns. CONCLUSIONS: Both resin bases formulated for microwave polymerization were effectively polymerized around metal frameworks without adverse effects on resin hardness or porosity. Justi Denture Base material had poorer base adaptation than the other two resins.

Acrylic Resins↗

THE ENHANCEMENT OF 19S ANTIBODY PRODUCTION BY PARTICULATE ANTIGEN.

Injection of human thyroglobulin solution into rabbits gave rise to a transient 19S antibody response which could however be maintained by repeated administration of antigen. When the antigen was coated onto acrylic resin particles, the titre of 19S antibodies was increased nearly 20-fold whereas 7S antibody levels were unchanged. This selective enhancement of 19S antibody synthesis by particulate antigen was also seen using human gamma-globulin. "Intermediate" sedimenting and 7S gamma(1)-antibodies were also increased in animals given particulate antigen. These phenomena may be due to prolonged persistence of the antigen in appropriate macrophages or perhaps to an increased uptake into these cells. The results are discussed in terms of the relationship between 19S and 7S globulin-producing cells.

Acrylic Resins↗

In vitro evaluation of the influence of repairing condition of denture base resin on the bonding of autopolymerizing resins.

STATEMENT OF PROBLEM: Bonding failures of repair resin to denture base resin occurs when denture base resin is wet, however, little is known of how water relates to failures. PURPOSE: This study evaluated the influence of water absorbed in denture base resin on the bond strength and resistance to cyclic thermal stresses of autopolymerizing resins bonded to denture base resin. MATERIAL AND METHODS: Denture base resin disks (n = 180; 12 mm diameter and 3 mm thick) were fabricated from heat-polymerized acrylic resin (Lucitone 199). The disks were divided into groups (n = 60) with 3 conditions of water content: (1) complete water saturation (control), (2) superficial desiccation by blowing air on the specimen, or (3) complete desiccation. Each denture base specimen received 1 of 3 surface treatments (n = 20) including: (1) no treatment, (2) airborne-particle abrasion, or (3) methylene chloride application. An autopolymerizing repair resin (Repair Material, n = 10) or reline resin (Tokuso Rebase Normal set, n = 10) was applied to the bonding area (5 mm diameter) and polymerized at 37 degrees C for 10 minutes. The resistance to cyclic thermal stress was determined after subjecting the specimens to 50,000 thermal cycles between 4 degrees C and 60 degrees C water baths with a 1-minute dwell time (n = 5 per group). Bond strength (MPa) was measured by shear bond testing at a 1.0 mm/min crosshead speed until the applied resin debonded from denture base resin. Data were statistically analyzed by 3-way analysis of variance and multiple comparisons among the groups were performed with Bonferroni test (alpha = .05). RESULTS: The mean bond strengths of repair resin to airborne-particle-abraded denture base specimens were not significantly influenced by either thermal cycling or water content. The mean bond strengths of reline resin significantly decreased after thermal cycling (P < .0001) regardless of the conditions of surface treatment and water content. For methylene chloride treated specimens, bond strengths of both repair and reline resins to completely water saturated specimens were significantly higher than those of completely desiccated specimens (P = .0048 for repair resin, P < .0001 for reline resin) after thermal cycling. CONCLUSIONS: Bond strengths of autopolymerizing resin to denture base resin were not significantly influenced by water content of denture base resin but were significantly influenced by resin type, thermal cycling, and surface treatment.

Absorption↗

Effect of disinfection of custom tray materials on adhesive properties of several impression material systems.

The effects of impression tray disinfection procedures on the bond strength of impression-material adhesives to two types of resin trays were evaluated with a tensile test. Autopolymerizing acrylic resin and a visible light-curing resin were formed into one-half inch cubes. A screw eye was attached to each cube before polymerization. Perforated trays were fabricated with stops to maintain an even one-eighth inch of impression material over the resin block. Hooks on the opposite side permitted attachment of the metal plate to a mechanical testing machine. Before adhesive was applied, one third of the resin specimens were immersed in a 1:213 iodophor solution; one third in a 10% sodium hypochlorite solution, and one third were kept in the "as fabricated" condition. Polysulfide, polyether, and polyvinyl siloxane impression material-adhesive systems were evaluated. The resin-impression material-metal plate couples were attached to a mechanical testing machine and tensile forces were applied at a separation rate of 5 inches per minute. Mean values for adhesive strength ranged from 3.49 kg/cm2 for the autopolymerizing acrylic resin/iodophor/polyether combination to 10.55 kg/cm2 for the autopolymerizing acrylic resin/untreated/polyvinyl siloxane combination. Differences were detected among materials and disinfecting procedure. Clinically, disinfection of resin trays may adversely affect retention of the impression material to the tray.

Acrylic Resins↗

The effect of gypsum products and separating materials on the typography of denture base materials.

The typography of polymethyl methacrylate processed against various gypsum products coated with various separating materials was studied under an SEM. Tinfoil and two commercial tin foil substitutes were used as separating material during processing, and the surfaces of the resulting acrylic resin forms were studied for topographical differences. Tinfoil and alpha 2 hemihydrates produced the smoothest surfaces. As a practical solution, a good quality tinfoil substitute and alpha 1 hemihydrate could be used when processing polymethyl methacrylate resin.

Acrylic Resins↗