Noninvasive ventilation in patients with hypoxemic acute respiratory failure.

PURPOSE OF REVIEW: To discuss the recent literature concerning the use of noninvasive ventilation for hypoxemic acute respiratory failure. RECENT FINDINGS: The benefits of noninvasive ventilation for patients with hypoxemic acute respiratory failure are unclear. In immunocompromised patients and following thoracic surgery, there is a strong rationale for using noninvasive ventilation to treat acute respiratory failure. Prophylactic continuous positive airway pressure after abdominal or thoracic surgery and prophylactic noninvasive ventilation in patients at risk of extubation failure have proved beneficial. Recent studies show that noninvasive ventilation has a favourable impact in immunocompetent patients with acute lung injury/acute respiratory distress syndrome, but caution is required. In hypoxemic acute respiratory failure after extubation, one study reported excess mortality in patients treated with noninvasive ventilation, possibly related to the delay for intubation. A major issue is avoiding undue noninvasive ventilation prolongation and staying alert for predictors of early noninvasive ventilation failure. Caution, close monitoring, and broad experience are required. SUMMARY: Hypoxemic acute respiratory failure may benefit from noninvasive ventilation or continuous positive airway pressure, but undue prolongation should be avoided. In postextubation respiratory failure there is no evidence for routine use of noninvasive ventilation.

Acute Disease↗

Apneic diffusion oxygenation and continuous flow apneic ventilation. A review.

Evolution of life coincides with the most rapid rate of rise in atmospheric oxygen concentration during Devonian time. Oxygen is essential for life, but at the same time is a cellular poison if present in tensions considerably higher than those the particular cellular milieu has become adapted to. Animals exposed to low oxygen tensions breathe continuously, e.g. most species of fish obtain their oxygen from a continuous flow of water at low oxygen tensions. Evolution from water to land breathing generally is associated with intermittent breathing, mass movement of gas in one direction, i.e. inhalation and exhalation. Intermittent breathing is part of this evolutionary process and reduces the inspired oxygen tension from 150 mmHg (19.95 kPa) to approximately 100 mmHg (13.3 kPa) at the alveolar blood interface. Perhaps evolution from continuous ventilation to intermittent breathing may be protecting the body against the high atmospheric oxygen tension. Therefore, it is not surprising that mammals can have adequate oxygen uptake with apneic diffusion oxygenation (ADO) and continuous flow apneic ventilation (CFAV). Mechanical ventilation classic techniques, i.e. intermittent positive-pressure ventilation and continuous positive-pressure ventilation, employ ventilatory frequencies close to the resting breathing rate of the adult. Utilizing low-compression patient circuits has made mechanical ventilation with higher frequencies possible. 60 to 400 breaths per min is used for high-frequency positive-pressure ventilation and high-frequency jet ventilation, and up to 40 Hz is used for high-frequency oscillation (HFO). The two extremes of artificial ventilation - ADO, i.e. supply of O2 by continuous flow, and HFO, i.e. supply of O2 by oscillatory changes - both primarily involve diffusion, even though convection (also secondary to cardiac oscillations) obviously is important in the process of gas exchange. Some recent experimental findings favor continued development and evaluation of CFAV as an additional alternative to artificial ventilation.

Animals↗

International randomised controlled trial of patient triggered ventilation in neonatal respiratory distress syndrome.

AIM: To compare the effects of patient triggered ventilation (PTV) with conventional ventilation (IMV) in preterm infants ventilated for respiratory distress syndrome (RDS). METHODS: Nine hundred and twenty four babies from 22 neonatal intensive care units were assessed. They were under 32 weeks of gestation and had been ventilated for respiratory distress syndrome (RDS) for less than 6 hours within 72 hours of birth. The infants were randomly allocated to receive either PTV or IMV. Analysis was on an "intention to treat" basis. Death before discharge home or oxygen therapy at 36 weeks of gestation; pneumothorax while ventilated; cerebral ultrasound abnormality nearest to 6 weeks; and duration of ventilation in survivors were the main outcome measures. RESULTS: There was no significant difference in outcome between the two groups. Unadjusted rates for death or oxygen dependency at 36 weeks of gestation were 47.4% and 48.7%, for PTV and IMV, respectively; for pneumothorax these were 13.4% and 10.3%; and for cerebral ultrasound abnormality nearest to 6 weeks these were 35.4% and 36.9%. Median duration of ventilation for survivors in both groups was 6 days. Overall, 79% of babies received only their assigned ventilation. PTV babies were more likely to depart from their intended ventilation (27% vs 15%). The trend towards higher pneumothorax rates with PTV occurred only in infants below 28 weeks of gestation (18.8% vs 11.8%). CONCLUSIONS: There was no observed benefit from the use of PTV, with a trend towards a higher rate of pneumothorax under 28 weeks of gestation. Although PTV has a similar outcome to IMV for treatment of RDS in infants of 28 weeks or more gestation, within 72 hours of birth, it was abandoned more often. It cannot be recommended for infants of less than 28 weeks' gestation with the ventilators used in this study.

Brain Diseases↗

Haemodynamic effects of pressure support and PEEP ventilation by nasal route in patients with stable chronic obstructive pulmonary disease.

BACKGROUND: Intermittent positive pressure ventilation applied through a nasal mask has been shown to be useful in the treatment of chronic respiratory insufficiency. Pressure support ventilation is an assisted mode of ventilation which is being increasingly used. Invasive ventilation with intermittent positive pressure, with or without positive end expiratory pressure (PEEP), has been found to affect venous return and cardiac output. This study evaluated the acute haemodynamic support ventilation by nasal mask, with and without the application of PEEP, in patients with severe stable chronic obstructive pulmonary disease and hypercapnia. METHODS: Nine patients with severe stable chronic obstructive pulmonary disease performed sessions lasting 10 minutes each of pressure support ventilation by nasal mask while undergoing right heart catheterisation for clinical evaluation. In random order, four sessions of nasal pressure support ventilation were applied consisting of: (1) peak inspiratory pressure (PIP) 10 cm H2O, PEEP 0 cm H2O; (2) PIP 10 cm H2O, PEEP 5 cm H2O; (3) PIP 20 cm H2O, PEEP 0 cm H2O; (4) PIP 20 cm H2O, PEEP 5 cm H2O. RESULTS: Significant increases in arterial oxygen tension (Pao2) and saturation (Sao2) and significant reductions in arterial carbon dioxide tension (PaCO2) and changes in pH were observed with a PIP of 20 cm H2O. Statistical analysis showed that the addition of 5 cm H2O PEEP did not further improve arterial blood gas tensions. Comparison of baseline values with measurements performed after 10 minutes of each session of ventilation showed that all modes of ventilation except PIP 10 cm H2O without PEEP induced a small but significant increase in pulmonary capillary wedge pressure. In comparison with baseline values, a significant decrease in cardiac output and oxygen delivery was induced only by the addition of PEEP to both levels of PIP. CONCLUSIONS: In patients with severe stable chronic obstructive pulmonary disease and hypercapnia, pressure support ventilation with the addition of PEEP delivered by nasal mask may have short term acute haemodynamic effects in reducing oxygen delivery in spite of adequate levels of SaO2.

Aged↗

Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube.

Many ventilators measure expired tidal volume (VT) without compensation either for the compliance of the ventilator circuit or for variations in the circuit setup. We hypothesized that the exhaled VT measured with a conventional ventilator at the expiratory valve would differ significantly from the exhaled VT measured with a pneumotachometer placed at the endotracheal tube. To investigate this we studied 98 infants and children requiring conventional ventilation. We used linear regression analysis to compare the VT obtained with the pneumotachometer with the ventilator-measured volume. An additional comparison was made between the pneumotachometer volume and a calculated effective VT. For infant circuits (n = 70), our analysis revealed a poor correlation between the expiratory VT measured with the pneumotachometer and the ventilator-measured volume (r(2) = 0.54). Similarly, the expiratory VT measured with the pneumotachometer did not correlate with the calculated effective volume (r(2) = 0.58). For pediatric circuits (n = 28), there was improved correlation between the expiratory VT measured with the pneumotachometer and both the ventilator-measured volume and the calculated effective VT (r(2) = 0.84 and r(2) = 0.85, respectively). The data demonstrate a significant discrepancy between expiratory VT measured at a ventilator and that measured with a pneumotachometer placed at the endotracheal tube in infants. Correcting for the compliance of the ventilator circuit by calculating the effective VT did not alter this discrepancy. In conventionally ventilated infants, exhaled VT should be determined with a pneumotachometer placed at the airway.

Analysis of Variance↗

Breathlessness induced by dissociation between ventilation and chemical drive.

Suppression of ventilation by tasks such as talking may produce breathlessness in normal individuals under conditions when a strong respiratory drive exists, e.g., during exercise, and in patients with severe lung disease. To investigate the nature of breathlessness produced by a dissociation between ventilation and chemical drive, we studied ten naive normal subjects who breathed at various levels of ventilation while end-tidal PCO2 (PETCO2) was held at 55 mm Hg. After a 10-min equilibration period of free breathing at PETCO2 = 55 mm Hg, subjects used a visual target to adjust ventilation to five different levels ranging from 50% below to 50% above the chemically driven ventilation (CDV). Ratings of breathlessness were made on a visual analogue scale relative to the intensity of breathlessness experience at CDV. As ventilation was targeted to levels below CDV, all subjects became increasingly breathless; the response was more variable when ventilation was targeted to levels above CDV. Overall, the relationship between ventilation and breathlessness was described by a hyperbolic function, for which the coefficient of determination (R2) was 0.92. Ventilation was suppressed below CDV without recruitment of antagonistic muscles during inspiration. The intensity of breathlessness was not correlated with measures of respiratory effort. We conclude that suppressed ventilation is a useful model for the study of breathlessness not fully explained by measures of respiratory effort and we speculate that the dissociation between chemical drive and afferent signals produced by motion of the lung and chest wall is important in modulating the sensation of breathlessness.

Abdominal Muscles↗

Imbalances in regional lung ventilation: a validation study on electrical impedance tomography.

Imbalances in regional lung ventilation, with gravity-dependent collapse and overdistention of nondependent zones, are likely associated to ventilator-induced lung injury. Electric impedance tomography is a new imaging technique that is potentially capable of monitoring those imbalances. The aim of this study was to validate electrical impedance tomography measurements of ventilation distribution, by comparison with dynamic computerized tomography in a heterogeneous population of critically ill patients under mechanical ventilation. Multiple scans with both devices were collected during slow-inflation breaths. Six repeated breaths were monitored by impedance tomography, showing acceptable reproducibility. We observed acceptable agreement between both technologies in detecting right-left ventilation imbalances (bias = 0% and limits of agreement = -10 to +10%). Relative distribution of ventilation into regions or layers representing one-fourth of the thoracic section could also be assessed with good precision. Depending on electrode positioning, impedance tomography slightly overestimated ventilation imbalances along gravitational axis. Ventilation was gravitationally dependent in all patients, with some transient blockages in dependent regions synchronously detected by both scanning techniques. Among variables derived from computerized tomography, changes in absolute air content best explained the integral of impedance changes inside regions of interest (r(2) > or = 0.92). Impedance tomography can reliably assess ventilation distribution during mechanical ventilation.

Adult↗

Effects of mechanical ventilation on diaphragm function and biology.

The pathophysiological mechanisms of weaning from mechanical ventilation are not fully known, but there is accumulating evidence that mechanical ventilation induces inspiratory muscle dysfunction. Recently, several animal models have provided potential mechanisms for mechanical ventilation-induced effects on muscle function. In patients, weaning difficulties are associated with inspiratory muscle weakness and reduced endurance capacity. Animal studies demonstrated that diaphragm force was already decreased after 12 h of controlled mechanical ventilation and this worsened with time spent on the ventilator. Diaphragmatic myofibril damage observed after 3-days controlled mechanical ventilation was inversely correlated with maximal diaphragmatic force. Downregulation of the diaphragm insulin-like growth factor-I and MyoD/myogenin messenger ribonucleic acid occurred after 24 h and diaphragmatic oxidative stress and increased protease activity after 18 h. In keeping with these findings, diaphragm fibre atrophy was shown after 12 h and reduced diaphragm mass was reported after 48 h of controlled mechanical ventilation. These animal studies show that early alterations in diaphragm function develop after short-term mechanical ventilation. These alterations may contribute to the difficulties in weaning from mechanical ventilation seen in patients. Strategies to preserve respiratory muscle mass and function during mechanical ventilation should be developed. These may include: adaptation of medication, training of the diaphragm, stabilisation of the catabolic state and pharmacotherapy.

Animals↗

Equipment needs for noninvasive mechanical ventilation.

Noninvasive mechanical ventilation (NIV) has a long tradition for the treatment of chronic respiratory failure and more recently has also been applied in acute respiratory failure. Based on this experience both critical care ventilators and portable ventilators are used to perform NIV. The individual choice of ventilator type should depend on the patient's condition and also on the expertise of attending staff, therapeutic requirements and the location of care. The majority of studies have used pressure-targeted ventilation in the assist mode. Positive qualities of pressure support ventilation (PSV) are leak compensation, good patient/ventilator synchrony and the option of integrated positive end-expiratory pressure to counteract the effect of dynamic hyperinflation. In this article, some crucial issues concerning PSV (i.e. triggering into inspiration, pressurisation, cycling into expiration and carbon dioxide rebreathing) and some corrective measures are discussed. The parameters which should be monitored during noninvasive ventilation are presented. The interface between patient and ventilator is a crucial issue of noninvasive ventilation. Advantages and disadvantages of face and nasal masks are discussed. Finally, causes and possible remedies of significant air leaks and some technical accessories for noninvasive ventilation are dealt with.

Chronic Disease↗

Comparison of two different modes for noninvasive mechanical ventilation in chronic respiratory failure: volume versus pressure controlled device.

The most commonly used mode of noninvasive mechanical ventilation (NMV) is volume-controlled intermittent positive pressure ventilation (IPPV). Pressure support ventilation has recently become increasingly popular, but its merits have not been clearly defined. In an open, nonrandomized follow-up study, we evaluated two modes of NMV, volume-controlled (IPPV) and pressure-controlled ventilation (PCV) over 6 months in 30 consecutive patients (24 males and 6 females, aged 49 +/- 19 yrs) with chronic respiratory failure (CRF). The baseline assessments comprised both physiological and subjective data. In all cases, nasal IPPV was initially administered for 1 month, followed by a second month of nasal PCV. Thereafter, responders or nonresponders to PCV were defined according to the patients' subjective symptom score and/or the recurrence of hypercapnia. During the IPPV phase, in all but two patients the subjective and objective parameters improved significantly. During the following 1 month PCV phase, stabilization was maintained in 18 patients ("responders"), while 10 patients were defined as "nonresponders". In nonresponders, hypercapnia increased (arterial carbon dioxide tension (Pa,CO2): 5.7 +/- 0.4 to 6.6 +/- 0.5 kPa; p < 0.05) and symptom scores decreased. Compared with responders, nonresponders had a lower mean nocturnal arterial oxygen saturation (Sa,O2) (p < 0.05) and a higher daytime Pa,CO2 (p < 0.05) at baseline. We con clude that the majority of patients suffering from chronic respiratory failure who are initially satisfactorily ventilated with intermittent positive pressure ventilation may also be adequately maintained with pressure-controlled ventilation. However, there is a subgroup with more severe chronic respiratory failure at baseline, in whom pressure-controlled ventilation is inadequate. After 4 weeks of treatment with pressure-controlled ventilation, the subjective scores and the arterial carbon dioxide tension values reliably distinguished between long-term responders and nonresponders to pressure-controlled ventilation.

Adult↗

Effects of negative pressure assisted ventilation on dyspnoeic sensation and breathing pattern.

Although negative pressure assisted ventilation with an assist-control mode may have a potential therapeutic role in the treatment of severe dyspnoea, the effects of negative pressure assisted ventilation with the assist-control mode on dyspnoea and breathing patterns have not been examined. We examined the effects of negative pressure assisted ventilation with the assist-control mode on dyspnoea and breathing patterns produced by a combination of resistive loading and hypercapnia in nine healthy subjects breathing spontaneously. Subjects were asked to rate their sensation of respiratory discomfort using a visual analogue scale. Negative pressure assisted ventilation caused a significant reduction in sensation of respiratory discomfort from a visual analogue scale score of 74 (55-91) (median (range)) before negative pressure assisted ventilation to 34 (15-53) during negative pressure assisted ventilation (p<0.01). During negative pressure assisted ventilation, there were significant changes in breathing patterns characterized by an increase in tidal volume and a decrease in respiratory frequency, while neither minute ventilation nor end-tidal carbon dioxide tension changed. Our results indicate that negative pressure assisted ventilation with the assist-control mode is effective in relief of dyspnoea and that negative pressure assisted ventilation influences the control of breathing to minimize respiratory discomfort.

Adult↗

Impact of a nurses' protocol-directed weaning procedure on outcomes in patients undergoing mechanical ventilation for longer than 48 hours: a prospective cohort study with a matched historical control group.

INTRODUCTION: The aim of the study was to determine whether the use of a nurses' protocol-directed weaning procedure, based on the French intensive care society (SRLF) consensus recommendations, was associated with reductions in the duration of mechanical ventilation and intensive care unit (ICU) length of stay in patients requiring more than 48 hours of mechanical ventilation. METHODS: This prospective study was conducted in a university hospital ICU from January 2002 through to February 2003. A total of 104 patients who had been ventilated for more than 48 hours and were weaned from mechanical ventilation using a nurses' protocol-directed procedure (cases) were compared with a 1:1 matched historical control group who underwent conventional physician-directed weaning (between 1999 and 2001). Duration of ventilation and length of ICU stay, rate of unsuccessful extubation and rate of ventilator-associated pneumonia were compared between cases and controls. RESULTS: The duration of mechanical ventilation (16.6 +/- 13 days versus 22.5 +/- 21 days; P = 0.02) and ICU length of stay (21.6 +/- 14.3 days versus 27.6 +/- 21.7 days; P = 0.02) were lower among patients who underwent the nurses' protocol-directed weaning than among control individuals. Ventilator-associated pneumonia, ventilator discontinuation failure rates and ICU mortality were similar between the two groups. DISCUSSION: Application of the nurses' protocol-directed weaning procedure described here is safe and promotes significant outcome benefits in patients who require more than 48 hours of mechanical ventilation.

Adult↗

Bench-to-bedside review: high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.

Mechanical ventilation is the cornerstone of therapy for patients with acute respiratory distress syndrome (ARDS). Paradoxically, mechanical ventilation can exacerbate lung damage--a phenomenon known as ventilator-induced lung injury. While new ventilation strategies have reduced the mortality rate in patients with ARDS, this mortality rate still remains high. High-frequency oscillatory ventilation (HFOV) is an unconventional form of ventilation that may improve oxygenation in patients with ARDS, while limiting further lung injury associated with high ventilatory pressures and volumes delivered during conventional ventilation. HFOV has been used for almost two decades in the neonatal population, but there is more limited experience with HFOV in the adult population. In adults, the majority of the published literature is in the form of small observational studies in which HFOV was used as 'rescue' therapy for patients with very severe ARDS who were failing conventional ventilation. Two prospective randomized controlled trials, however, while showing no mortality benefit, have suggested that HFOV, compared with conventional ventilation, is a safe and effective ventilation strategy for adults with ARDS. Several studies suggest that HFOV may improve outcomes if used early in the course of ARDS, or if used in certain populations. This review will summarize the evidence supporting the use of HFOV in adults with ARDS.

Blood Pressure↗

Pulmonary and systemic induction of SAA3 after ventilation and endotoxin in preterm lambs.

Serum amyloid A (SAA), an acute phase reactant (APR) protein, is induced in liver during systemic inflammation. Serum amyloid A3 (SAA3), an isoform of SAA, is induced in both liver and extra hepatic sites in response to proinflammatory stimuli such as cytokines. Previously, we showed a modest increase in plasma cytokine levels in a preterm lamb model of lung injury. The study objective was to determine the relative contributions of lung and liver to the acute phase response during postnatal lung injury. Preterm (130d) and near term (141d) newborn lambs (term=150d) were randomized to either no ventilation (controls), ventilation+intratracheal (IT) endotoxin (endo) or ventilation+IT saline. A group of near term lambs were exposed to ventilation+IV endotoxin. In the lungs, ventilation alone increased SAA3 mRNA 3- and 13-fold while ventilation+IT endotoxin increased SAA3 mRNA 64 and 366-fold above controls in preterm and near term lambs, respectively. In the liver, SAA3 mRNA was induced by ventilation alone (three-fold) and ventilation+IT endotoxin (45-fold) above controls in both preterm and near term animals. Ventilation + IV endotoxin caused the highest increase in SAA3 mRNA (212-fold) in the liver of near term animals. A different isoform, identified as SAA-Liver inducible was maximally induced in liver by ventilation alone with minimal further response to endotoxin. Lung SAA3 mRNA expression was detected primarily in airway epithelium, bronchial glands, perichondrium of bronchial cartilage and vascular smooth muscle cells. Our experiments show rapid induction of an APR gene in lung in response to proinflammatory stimuli.

Acute Disease↗

Prevalence and severity of neurologic dysfunction in critically ill patients. Influence on need for continued mechanical ventilation.

OBJECTIVE: The relative importance of neurologic dysfunction in critically ill mechanically ventilated patients has not been well studied. This study investigates the prevalence of neurologic dysfunction in critically ill mechanically ventilated patients and its influence on preventing the discontinuation of mechanical ventilation and patient outcome. DESIGN: Prospective study. SETTING: University-based, tertiary care center. PATIENTS: All eligible adult patients mechanically ventilated for more than 48 h were included. A total of 66 patients were evaluated. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Two independent questionnaires, one completed by the critical care attending physician documenting the major clinical factors necessitating continued mechanical ventilation, and a second questionnaire, completed by a critical-care trained neurologist documenting neurologic status and objective cardiopulmonary status formed the basis for outcome measurements. Respiratory and physiologic data, the patient's clinical conditions, and outcome (mortality) were also included in the database. RESULTS: Pulmonary factors were the major reason for prolonged ventilation in only 51 percent of the patient evaluations. Neurologic status was the major factor necessitating continued mechanical ventilation in 32 percent of the patient evaluations and a significant contributing factor in an additional 41 percent. Of the neurologic factors, diminished level of consciousness was the major cause of continued ventilatory support. This was usually due to a systemic illness, rather than a primary central nervous system disorder. Mortality was significantly lower in patients who continued to require mechanical ventilation after 48 h because of neurologic factors as opposed to pulmonary factors (15 percent vs 72 percent, p = 0.002). CONCLUSIONS: There is a high prevalence of neurologic dysfunction in critically ill patients and this problem plays a significant role in preventing the discontinuation of mechanical ventilation. Altered mental status is a major factor necessitating continued mechanical ventilation in combined medical-surgical intensive care units.

Central Nervous System Diseases↗

Evolution in the utilization of the mechanical ventilation in the critical care unit.

Use of mechanical ventilation has increased in recent years and constitutes a major therapeutic modality in the intensive care unit (ICU). In the recent years, changes in the ventilatory modes, in the ventilatory strategies and in the weaning from mechanical ventilation have occurred. We have compared the data obtained from the Spanish ICUs in studies that were carried out in three periods of the nineties, with the aim to test whether the aforementioned innovations have modified the clinical practice. We analyzed demographic data, primary reason for mechanical ventilation, ventilatory parameters, mode of weaning and performance of tracheostomy. It was observed a decrease in the percentage of patients receiving mechanical ventilation. There was a significant trend to ventilate older patients over the course of the decade. In the mode of ventilation, we observed a significant decrease in the use of the synchronized intermittent mandatory ventilation with a increment in the use of assist-control ventilation. We did not find differences in the ventilatory settings. Concerning to weaning, over the course of the decade occurred an increase in use of pressure support ventilation and spontaneous breathing trial, being this method the most frequently used at the end of the decade. The performance of the tracheostomy has been lesser and earlier over the time. The results obtained suggest that findings from research on mechanical ventilation are incorporated into clinical practice at a very slow pace whereas the evidence obtained from the clinical trials about weaning has had a better reception.

Female↗

Modification of a critical care ventilator for use during magnetic resonance imaging.

INTRODUCTION: The unique electromagnetic environment of the magnetic resonance imaging (MRI) scanner presents particular problems for critically ill patients requiring mechanical ventilation during MRI. Most currently available MRI-compatible ventilators are limited in scope and function and thus may not be suitable for patients requiring high peak inspiratory pressure or flow. METHODS: To determine whether a standard critical care ventilator could be used under MRI conditions, we modified a Siemens Servo 900C by replacing the standard oxygen blender with an MRI-compatible blender. We then calibrated the ventilator and tested it on a mechanical lung during active MRI scanning at magnetic fields up to 1.5 tesla. After verifying adequate function, we used the ventilator to support 21 critically ill patients requiring mechanical ventilation during MRI. RESULTS: In all cases we found no alterations in ventilator performance resulting from the electromagnetic interference typical of an MRI scan. We also found no abnormalities in the alarm systems for fraction of inspired oxygen, high inspiratory pressure, or minute volume. Finally, we found no degradation of MRI image quality resulting from ventilator operation during test scanning. CONCLUSIONS: We conclude that with minor modifications the Siemens 900C ventilator can safely ventilate critically ill patients during MRI.

Adolescent↗

Imposed work of breathing during ventilator failure.

INTRODUCTION: Ventilators possess an anti-asphyxia valve that allows spontaneous breathing of ambient air during ventilator failure. This study examined the imposed work of breathing and pressure-time product of 8 critical care and 9 portable ventilators, using a laboratory simulation of spontaneous breathing during ventilator failure. METHODS: A test lung was modified to simulate spontaneous breathing with a tidal volume of 0.5 L and peak inspiratory flow of 60 L/min. A pneumotachograph and pressure tap were placed at the proximal airway between the breathing circuit and endotracheal tube. Flow was derived from the pressure drop across the pneumotachograph. Signals were amplified, integrated, and saved to a spreadsheet program, and imposed work of breathing and pressure-time product were calculated. Also measured were the inspiratory pressure required to open the anti-asphyxia valve (cracking pressure), time to cracking pressure, maximum negative inspiratory pressure, and time to maximum negative inspiratory pressure. RESULTS: For the critical care ventilators the mean +/- SD imposed work of breathing ranged from 213.07 +/- 3.53 to 890.63 +/- 0.88 mJ/L and the pressure-time product ranged from 2.67 +/- 0.01 to 13.37 +/- 0.01 cm H(2)O x s/L. For the portable ventilators the mean +/- SD imposed work of breathing ranged from 361.37 +/- 1.22 to 969.60 +/- 22.70 mJ/L and the pressure-time product ranged from 4.52 +/- 0.01 to 16.70 +/- 0.37 cm H(2)O x s/L. CONCLUSIONS: Spontaneous breathing during ventilator failure may impose work approximating the physiologic work of breathing. This imposed work may prevent effective breathing through the anti-asphyxia valve during mechanical ventilator failure due to electrical failure. These results reinforce the need to properly monitor mechanically ventilated patients and to have in place sufficient back-up power supplies and a method of manual ventilation.

Equipment Design↗