Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Rotation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75Linked to original sources

Application of rigid body mechanics to theoretical description of rotation within F0F1-ATP synthase.

ATP synthase catalyses the formation of ATP from ADP and P(i) and is powered by the diffusion of protons throughout membranes down the proton electrochemical gradient. The protein consists of a water-soluble F(1) and a transmembrane F(0) proton transporter part. It was previously shown that the ring of membrane subunits rotates past a fixed subunit during catalytic cycle of the enzyme. However, many parameters of this movement are still unknown. In the present study the mutual protein movement in the membrane part of F(0)F(1)-ATP syntase has been analysed within the framework of rigid body mechanics. On the base of available experimental data it was shown that electrostatic interaction of two charged amino acids residues is able to supply quite enough energy for the rotation. The initial torque, which caused the rotation, was estimated as 3.7 pN nm and for this pattern the angular movement of c subunits complex could not physically have a period less than 10(-9)s. If membrane viscosity and elastic resistance were taken into account then the time of a whole turnover could rise up to 6.3 x 10(-3)s. It is remarkable that rotation will take place only under condition when the elasticity (Young's) module of the central stalk (gamma subunit and other minor subunits) is less than 5.0 x 10(7)N/m(2). Thus, for generally accepted structural parameters of ATP synthase, two-charge electrostatic interaction model does not permit rotation of the rotor if elastic properties of the central stalk are tougher than mentioned above. In order to explain the rotation under that condition one should either suppose a shorter distance between subunit a and c subunits complex or assume interaction of more than two charged amino acids residues.

Adenosine Triphosphate↗

The flexion-rotation test and active cervical mobility--a comparative measurement study in cervicogenic headache.

A single blind, age and gender matched, comparative measurement study was designed to assess active range of cervical motion and passive range of rotation in cervical flexion in asymptomatic and cervicogenic headache subjects. Both procedures are commonly used in clinical practice to evaluate patients with cervicogenic headache. We studied 20 women and eight men with side dominant cervicogenic headache (mean age 43.3 years) matched with 28 asymptomatic subjects. Two experienced manipulative therapists, who were blind to each other's measurement, noted active ranges of cervical motion and passive cervical rotation performed in the flexion-rotation test using the Cervical Range of Motion Device. Headache severity was assessed by a questionnaire. Additionally, one therapist prior to neck motion assessment determined the dominant symptomatic cervical motion segment. Active cervical motion in each direction was identical between the cervicogenic and control groups. In contrast, average rotation in flexion was 44 degrees to each side in the asymptomatic group and 28 degrees towards the headache side in the symptomatic group. C1-2 was deemed to be the dominant segmental level of headache origin in 24 of 28 subjects. In those 24 subjects range of rotation during the flexion-rotation test was inversely correlated to headache severity.

Adult↗

Manual fixation versus locking during upper cervical segmental mobilization. Part 2: an in vitro three-dimensional arthrokinematic analysis of manual axial rotation and lateral bending mobilization of the atlanto-axial joint.

BACKGROUND: Three-dimensional kinematic aspects of coupled motion during manual cervical mobilization have not previously been studied. Using an in vitro 3D-motion analysis method, the kinematic effects of two different segmental techniques for axial rotation and lateral bending mobilization of the upper cervical spine were investigated as a second part of the study (in part one, kinematic effects of flexion-extension mobilization have been investigated). METHODS: Axial rotation and lateral bending mobilization of the atlanto-occipital and atlanto-axial segments were analysed in vitro using an electromagnetic tracking device. Local reference frames were defined based on bony reference points that were registered using a 3D-digitizing stylus. Five embalmed and one fresh specimen were analysed. Segmental motion was registered simultaneously in the atlanto-occipital and the atlanto-axial joints during manual mobilization through the full range of axial rotation and lateral bending mobility. The 3D-kinematic aspects during regional mobilization were compared with those during segmental mobilization with manual fixation and during segmental mobilization using a locking technique. RESULTS: During both segmental axial rotation techniques of the atlanto-axial joint, a significant reduction of the coupled lateral bending and flexion-extension motion was observed. The locking technique also induced an increase in the main axial rotation component. During lateral bending mobilization of the atlanto-axial joint, the manual fixation technique reduced the effect on the coupled flexion-extension component significantly. INTERPRETATIONS: These results suggest that for manual segmental axial rotation and lateral bending mobilization of the upper cervical spine segmental manual fixation or locking may be preferred in different situations depending on the desired effects. This study brings additional information to the data provided by part 1 of this study on the 3D-arthrokinematic effects of flexion-extension mobilization.

Atlanto-Axial Joint↗

Reproduction of self-rotation duration.

The vestibular system detects the velocity of the head even in complete darkness, and thus contributes to spatial orientation. However, during vestibular estimation of linear passive self-motion distance in darkness, healthy human subjects mainly rely on time, and they replicate also stimulus duration when required to reproduce previous self-rotation. We then made the hypothesis that the perception of vestibular-sensed motion duration is embedded within encoding of motion kinetics. The ability to estimate time during passive self-motion in darkness was examined with a self-rotation reproduction paradigm. Subjects were required to replicate through self-driven transport the plateau velocity (30, 60 and 90 degrees /s) and duration (2, 3 and 4s) of the previously imposed whole-body rotation (trapezoid velocity profile) in complete darkness; the rotating chair position was recorded (500 Hz) during the whole trials. The results showed that the peak velocity, but not duration, of the plateau phase of the imposed rotation was accurately reproduced. Suspecting that the velocity instruction had impaired the duration reproduction, we added a control experiment requiring subjects to reproduce two successive identical rotations separated by a momentary motion interruption (MMI). The MMI was of identical duration to the previous plateau phase. MMI duration was fidelitously reproduced whereas that of the plateau phase was hypometric (i.e. lesser reproduced duration than plateau) suggesting that subjective time is shorter during vestibular stimulation. Furthermore, the accurate reproduction of the whole motion duration, that was not required, indicates an automatic process and confirms that vestibular duration perception is embedded within motion kinetics.

Adult↗

One good turn deserves another: an event-related brain potential study of rotated mirror-normal letter discriminations.

The time to decide if a letter is normal or backwards (mirror-reversed) increases as the letter is rotated away from the upright. It is widely accepted that this increase in time reflects the mental rotation of the stimulus to the upright orientation in order to determine the mirror-normal status of the stimulus. Although response times tend to be longer for mirrored stimuli than for normal stimuli, the difference is constant across orientation. Little work has been focused on why mirror-image stimuli produce longer response times than normal stimuli. This study examines the question of whether or not mirrored stimuli are rotated in the picture plane at the same time as normal stimuli, and if so, why response times to mirrored stimuli are longer than that for normal stimuli. Both the behavioural and electrophysiological findings suggest that the mirrored stimuli are not only rotated in the picture plane, but that they are subsequently rotated to the normal view. It is this additional rotation that produces, at least in part, the delayed response times for mirror-image stimuli.

Adult↗

The effect of binocular eye position and head rotation plane on the human torsional vestibuloocular reflex.

We examined how the gain of the torsional vestibulo-ocular reflex (VOR) (defined as the instantaneous eye velocity divided by inverted head velocity) in normal humans is affected by eye position, target distance, and the plane of head rotation. In six normal subjects we measured three-dimensional (3D) eye and head rotation axes using scleral search coils, and 6D head position using a magnetic angular and linear position measurement device, during low-amplitude (approximately 20 degrees ), high-velocity (approximately 200 degrees/s), high-acceleration (approximately 4000 degrees /s2) rapid head rotations or 'impulses.' Head impulses were imposed manually and delivered in five planes: yaw (horizontal canal plane), pitch, roll, left anterior-right posterior canal plane (LARP), and right anterior-left posterior canal plane (RALP). Subjects were instructed to fix on one of six targets at eye level. Targets were either straight-ahead, 20 degrees left or 20 degrees right from midline, at distance 15 or 124 cm from the subject. Two subjects also looked at more eccentric targets, 30 degrees left or 30 degrees right from midline. We found that the vertical and horizontal VOR gains increased with the proximity of the target to the subject. Previous studies suggest that the torsional VOR gain should decrease with target proximity. We found, however, that the torsional VOR gain did not change for all planes of head rotation and for both target distances. We also found a dynamic misalignment of the vertical positions of the eyes during the torsional VOR, which was greatest during near viewing with symmetric convergence. This dynamic vertical skew during the torsional VOR arises, in part, because when the eyes are converged, the optical axes are not parallel to the naso-occipital axes around which the eyes are rotating. In five of six subjects, the average skew ranged 0.9 degrees -2.9 degrees and was reduced to <0.4 degrees by a 'torsional' quick-phase (around the naso-occipital axis) occurring <110 ms after the onset of the impulse. We propose that the torsional quick-phase mechanism during the torsional VOR could serve at least three functions: (1) resetting the retinal meridians closer to their usual orientation in the head, (2) correcting for the 'skew' deviation created by misalignment between the axes around which the eyes are rotating and the line of sight, and (3) taking the eyes back toward Listing's plane.

Adult↗

Reversal of apparent rotation in the Enigma-figure with and without motion adaptation and the effect of T-junctions.

We studied the time course of apparent rotation and directional reversal in Leviant's Enigma figure. On average, periods of clockwise rotation lasted 5.0 s as opposed to 4.4 for counter-clockwise rotation, resulting in an average reversal frequency of 6.4 within 30 s. At the beginning of a trial, clockwise rotation was perceived almost twice as often as counter-clockwise rotation. This bias could be shifted by previous adaptation to a black-and-white rotating sector disk, suggesting a neural interaction between real motion and illusory motion. We further studied Enigma-type motion on a chromatic bar superimposed onto a black-and-white linear grating. Illusory motion was strongest when the bar was oriented at 90 deg to the grating lines and became progressively weaker with a decrease in angle. This suggests that T-junctions formed by the radial rays impinging onto the colored rings of the Enigma figure are instrumental for eliciting the rotary motion and may rule out a low-level sensory origin of the illusion.

Adult↗

Autologous ipsilateral rotating penetrating keratoplasty.

PURPOSE: To evaluate visual outcome after autologous ipsilateral rotating penetrating keratoplasty. METHODS: The study included nine patients who consecutively underwent autologous ipsilateral rotating penetrating keratoplasty for treatment of traumatic central corneal avascular scars. These patients were compared with 105 patients who consecutively underwent homologous central penetrating keratoplasty in the same study period for treatment of avascular corneal scars extending to the corneal periphery. All operations were performed by the same surgeon. Mean follow-up time for both study groups was 31.27 +/- 21.54 and 32.0 +/- 19.4 months, respectively. RESULTS: In the autologous rotating keratoplasty group, visual acuity increased significantly (P = 0.03; Wilcoxon test) from 0.13 +/- 0.11 preoperatively to 0.29 +/- 0.16 postoperatively. Refractive astigmatism and keratometric astigmatism, respectively, increased (P = 0.02) from 3.19 +/- 2.53 diopters and 3.20 +/- 2.24 diopters, respectively, preoperatively to 6.9 +/- 1.82 diopters and 9.55 +/- 4.32 diopters, respectively, postoperatively. Comparing the study groups, postoperative visual acuity was significantly lower (P = 0.01), and keratometric astigmatism (P = 0.003) and refractive astigmatism (P = 0.01) were significantly higher in the autologous rotating keratoplasty group than in the control group. CONCLUSIONS: Autologous ipsilateral rotating penetrating keratoplasty compared with homologous central penetrating keratoplasty is associated with a high postoperative refractive and keratometric astigmatism leading to a relatively low postoperative visual acuity. It suggests that, in normal clinical conditions when donor material is available and postoperative follow-up examinations can be performed, homologous central penetrating keratoplasty may be superior to autologous ipsilateral rotating keratoplasty.

Adolescent↗

Naming rotated pictures and the riddle of object-centred neglect.

In this study eight patients with left neglect were asked to name chimerical pictures of objects and animals with different spatial orientation: standard upright position, rotated 180 degrees, rotated 90 degrees to the right, and rotated 90 degrees to the left. All patients showed the typical pattern of egocentric neglect. They omitted the left part of the normally upright pictures and the right part of the inverted stimuli, now falling in the left space. When the pictures were tilted 90 degrees to the right, they reported the two component objects with the same level of accuracy. However, at variance with egocentric neglect, when the chimerical pictures were rotated 90 degrees to the left, the patients omitted the left half of the stimulus more often than the right half. We propose that since in the latter condition the less informative lower part of the pictures was available in the non-neglected space, the patients mentally rotated the perceived stimulus and aligned it with its upright orientation before naming its component parts. In our interpretation, the mental orientation and normalisation of rotated stimuli might underlie all the reported evidence of object-centred neglect for non-orthographic stimuli.

Aged↗

Lack of synergism between caffeine and SKF 38393 on rotational behavior in 6-hydroxydopamine-denervated rats.

We have recently shown a synergistic effect between caffeine and the dopamine D(2) receptor agonist, bromocriptine, on contralateral rotational behavior in unilaterally 6-hydroxydopamine-denervated rats. In addition, we found that bromocriptine prevented caffeine-induced tolerance to this behavior following repeated treatment. In the present study, we investigated whether or not the dopamine D(1) receptor agonist, (+/-)-phenyl-2,3,4, 5-tetrahydro-(1H)-3-benzazepine-7,8-diol (SKF 38393), presented similar characteristics. Different groups of rats received simultaneous injections of either vehicle plus vehicle, caffeine (40 mg/kg) plus vehicle, SKF 38393 (0.5, 1, 2, and 4 mg/kg) plus vehicle, or caffeine plus SKF 38393 (0.5, 1, 2, and 4 mg/kg) for 5 consecutive days, and both ipsilateral and contralateral rotational behavior was measured. Results showed that, on the first day of treatment, caffeine produced significantly more rotational behavior than did a low dose of SKF 38393 (0.5 mg/kg), and significantly less turning than at higher doses (2 and 4 mg/kg). Combined treatment with caffeine and a high dose of SKF 38393 (4 mg/kg) produced significantly more rotational behavior than did caffeine plus vehicle. With repeated administration, caffeine produced sustained tolerance to its effects on rotational behavior, whereas SKF 38393 did not. In the groups treated with low doses of SKF 38393 (0.5, and 1 mg/kg) plus caffeine, tolerance was observed while in the groups that received high doses of SKF 38393 (2 and 4 mg/kg) plus caffeine, no tolerance was observed to rotational behavior. These results suggest that maximal stimulation of dopamine D(1) receptors may be needed to prevent the tolerance effects of caffeine in this animal model. This finding may have clinical relevance to the therapeutic treatment of Parkinson's disease.

2,3,4,5-Tetrahydro-7,8-dihydroxy-1-phenyl-1H-3-ben↗

Scapular kinematics: effects of altering the Euler angle sequence of rotations.

An analysis of Euler angle sequences is presented for the scapula. In vivo kinematics were collected with a magnetic tracking device on eight healthy volunteers. To ensure accurate representation of scapular motion, pins were rigidly drilled into the scapular spine. Three rotations of the scapula with respect to the thorax were recorded during humeral elevation in the scapular plane: posterior (or backward) tilting, upward (or lateral) rotation and external rotation (or retraction). Rotations using all six possible Euler angle sequences were calculated for which each angle was represented only once. The sequence proposed by an International Society of Biomechanics subcommittee on shoulder motion (external rotation, upward rotation, posterior tilting) is consistent with both research- and clinical-based two-dimensional representations of scapular motion. Results from the present study indicate that changing sequence results in significant alterations in the description of motion, with differences up to 50 degrees noted for some angles. Therefore, in order to compare results across different laboratories, it is recommended that the proposed standard sequence be adopted.

Adult↗

The glenohumeral joint rotation centre in vivo.

Within the framework of the current call for standardization in upper extremity research, three methods to determine the glenohumeral joint rotation centre in vivo were tested. Therefore, subjects performed humeral movements, while a 3D electromagnetic tracking device registered the motion of the humerus with respect to the scapula. For the first method to estimate the glenohumeral joint rotation centre five scapular bony landmarks served as input to regression equations. The second method fitted a sphere through the humeral position data and the third method calculated the rotation centre determining an optimal helical axis. The experiment consisted of two parts, at first one subject was measured 10 times, subsequently one observer measured 10 subjects twice and another observer measured these subjects once. The first part of the experiment demonstrated that all methods are capable to reproduce the rotation centre within 4mm, but the location of the centre differed significantly between methods (p<0.001). The second part, showed that inter- and intra-observer reliability was sufficiently for the sphere-fitting method and for the helical-axes method. The two observations of one observer differed significantly (p<0.008) using the regression method. The authors prefer the helical-axes method, it is a reliable and valid method which can be applied in movement registration of healthy subjects and patients with a shoulder endoprosthesis, it can be applied in hinge joints to determine a rotation axis instead of a rotation centre which is desirable in standardized upper extremity research, and calculation time is short.

Adult↗

Modeling the stability of the human glenohumeral joint during external rotation.

An analytical model of the human glenohumeral joint was developed to predict glenohumeral kinematics and investigate how the glenohumeral capsule and articular contact between the humeral head and the glenoid stabilize the joint. This was performed during a simulation of an apprehension clinical exam or the cocked phase of throwing, when the humerus is susceptible to anterior instability or dislocation. Contact between the joint surfaces was modeled using a deformable articular contact method and the capsule was modeled as five elements with the ability to wrap around the surface of the humeral head. Experimental measurements (Novotny et al., Journal of Shoulder and Elbow surgery, 1998, 7, 629-639) provided geometric data from four in vitro specimens and kinematic results to validate model predictions. Material properties were taken from the literature. An equilibrium approach was used with the forces and moments produced by the ligaments and surface contact balanced against those applied externally to the humerus during external rotation of the abducted and extended humerus. The six equilibrium equations were solved for the position and orientation of the humerus. The center of the humeral head translated posteriorly and superiorly with external rotation. Model predictions for translational and rotational ranges of motion were not significantly different from experimental findings; however, at individual moment increments, the model underestimated the external rotation and overestimated the superior-inferior position of the humerus relative to the glenoid. The anterior band of the inferior glenohumeral ligament increased in tension with external rotation, while the axillary pouch and posterior band decreased in tension. Contact area, stress and force increased with external rotation and the contact area moved posteriorly and inferiorly around the rim of the glenoid. The model results provide information on how the relationship between the ligament element tensions and contact forces may act to avoid glenohumeral instability.

Humans↗

Theory of the rotational contribution to facilitated diffusion.

Gros and others have recently shown experimentally that the facilitated diffusion of protons carried by a form of haemoglobin is enhanced by rotational diffusion of the carrier, whereas facilitated diffusion of oxygen by the same carrier is not. In this paper the theory of facilitated transport by rotating carriers is developed from first principles. The theory confirms Gros's findings that (i) the rotational contribution appears only when the angle of rotational diffusion over the average time the proton remains bound is small and (ii) under these conditions rotation enhances the normal translational contribution by a factor 1/2 at the lowest carrier concentrations. The theory also shows that there must be a rotational boundary layer.

Binding Sites↗

Patient rotation and resolution of unilateral cornual obstruction during hysterosalpingography.

OBJECTIVE: Unilateral obstruction of the proximal fallopian tube is identified in 10-24% of patients undergoing hysterosalpingography for evaluation of infertility. Upon further testing, this obstruction spontaneously resolves 16-80% of the time. We hypothesized that patient rotation during hysterosalpingography might resolve proximal tubal obstruction in some cases by altering either the location of intrauterine air bubbles or the spatial relationship of the tube to the uterine fundus. METHODS: In patients in whom unilateral proximal tubal obstruction was detected during hysterosalpingography performed for standard clinical indications, the patient was rotated on her hip approximately 45 degrees such that the obstructed tube was first superior (ventral) to the patent tube, and dye was reinjected. If obstruction did not resolve, the patient was rotated in the opposite direction so that the obstructed tube was inferior (dorsal) to the patent tube and dye reinjected. RESULTS: Unilateral tubal obstruction was found in 15% of cases (24 of 156). Rotating the patient with obstructed tube superior to the patent tube never resulted in tubal patency, whereas rotating the patient with the obstructed tube inferior resulted in resolution of tubal patency in 63% of cases (15 of 24) CONCLUSION: . Unilateral cornual obstruction during hysterosalpingography is often resolved by rotating the patient such that the obstructed tube is more inferior. Although this observation may be the result of dislodging smaller air bubbles, from a fluid dynamics perspective a more likely explanation is unkinking of the more inferior tube.

Adult↗

Paw preference, rotation, and dopamine function in Collins HI and LO mouse strains.

Mice have paw preferences that are consistent upon repeated measurement. The Collins HI and LO strains are two populations of mice that have been selectively bred to differ markedly in the degree of paw preference. They represent a unique genetic model of functional cerebral lateralization. Rotation (or circling) behavior in normal unlesioned animals reflects an endogenous lateralization of the functioning brain dopamine (DA) systems. In the present study, rotational behavior and lateralized brain DA neurochemistry were assessed in the Collins HI and LO strain mice. Confirming Collins findings, HI strain mice exhibited stronger paw preferences than LO strain mice. HI strain mice also showed stronger percent directional preferences during nocturnal tests of spontaneous rotation. Neurochemical differences were also apparent between the strains. DA and its metabolites were measured in the medial prefrontal cortex (PFC), nucleus accumbens (NAS), and striatum. Degrees of rotational and paw preference in HI, but not LO, mice were correlated with PFC asymmetries in DA and the DA metabolite dihydroxyphenyl acetic acid (DOPAC), respectively. Hemisphere, paw preference, turning preference, and strain interacted in a complex way to determine measures of DA utilization in the NAS and striatum. Even though the directions of paw preference and rotation were not correlated, HI and LO mice of differing paw and rotational directional preferences showed differences in DA neurochemistry in the NAS and striatum.

Animals↗

Measurement of angular velocity in the perception of rotation.

Humans are sensitive to the parameters of translational motion, namely, direction and speed. At the same time, people have special mechanisms to deal with more complex motions, such as rotations and expansions. One wonders whether people may also be sensitive to the parameters of these complex motions. Here, we report on a series of experiments that explore whether human subjects can use angular velocity to evaluate how fast a rotational motion is. In four experiments, subjects were required to perform a task of speed-of-rotation discrimination by comparing two annuli of different radii in a temporal 2AFC paradigm. Results showed that humans could rely on a sensitive measurement of angular velocity to perform this discrimination task. This was especially true when the quality of the rotational signal was high (given by the number of dots composing the annulus). When the signal quality decreased, a bias towards linear velocity of 5-80% appeared, suggesting the existence of separate mechanisms for angular and linear velocity. This bias was independent from the reference radius. Finally, we asked whether the measurement of angular velocity required a rigid rotation, that is, whether the visual system makes only one global estimate of angular velocity. For this purpose, a random-dot disk was built such that all the dots were rotating with the same tangential speed, irrespectively of radius. Results showed that subjects do not estimate a unique global angular velocity, but that they perceive a non-rigid disk, with angular velocity falling inversely proportionally with radius.

Humans↗

Depth information and perceived self-motion during simulated gaze rotations.

When presented with random-dot displays with little depth information, observers cannot determine their direction of self-motion accurately in the presence of rotational flow without appropriate extra-retinal information (Royden CS et al. Vis Res 1994;34:3197-214.). On theoretical grounds, one might expect improved performance when depth information is added to the display (van den Berg AV and Brenner E. Nature 1994;371:700-2). We examined this possibility by having observers indicate perceived self-motion paths when the amount of depth information was varied. When stereoscopic cues and a variety of monocular depth cues were added, observers still misperceived the depicted self-motion when the rotational flow in the display was not accompanied by an appropriate extra-retinal, eye-velocity signal. Specifically, they perceived curved self-motion paths with the curvature in the direction of the simulated eye rotation. The distance to the response marker was crucial to the objective measurement of this misperception. When the marker distance was small, the observers' settings were reasonably accurate despite the misperception of the depicted self-motion. When the marker distance was large, the settings exhibited the errors reported previously by Royden CS et al. Vis Res 1994;34-3197-3214. The path judgement errors observers make during simulated gaze rotations appear to be the result of misattributing path-independent rotation to self-motion along a circular path with path-dependent rotation. An analysis of the information an observer could use to avoid such errors reveals that the addition of depth information is of little use.

Cues↗