Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Retention”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75Linked to original sources

Effects of age and prosthesis material on in vitro cartilage retention of laryngoplasty prostheses in horses.

Cartilage retention strengths of laryngoplasty prostheses were compared in larynges of 2-, 3-, and 4-year-old horses, using doubled polyester and expanded polytetrafluoroethylene prostheses. Bilateral laryngoplasties were performed on each of 15 (seven 2-year-old, two 3-year-old, and six 4-year-old) larynges, which were collected at an abbatoir. Prostheses were secured to a mechanical testing machine, and tension causing arytenoid cartilage abduction was applied, until total failure of the cartilage or prosthesis resulted. Tension caused cricoid cartilage failure in 1 specimen, and muscular process cartilage failure in the remainder. There was no significant effect of age, prosthetic material, or side of prosthesis placement on cartilage retention of the prostheses. Additionally, frequency of multiple load-displacement peaks, indicating partial muscular process failure, was not affected by age or prosthetic material variables.

Age Factors↗

Stress transfer of four mandibular implant overdenture cantilever designs.

STATEMENT OF PROBLEM: The influence of implant number and cantilever design on stress distribution on bone has not been sufficiently assessed for the mandibular overdenture. PURPOSE: The purpose of this simulation study was to measure, photoelastically, the biologic behavior of 2 or 3 implants retaining different designs of cantilevered bar mandibular overdentures and to compare load characteristics. MATERIALS AND METHODS: Two photoelastic models of a human edentulous mandible were fabricated having 2 or 3 screw-type implants (Nobel Biocare, 3.75 x 10mm) embedded in the parasymphyseal area. Bar frameworks using a 7-mm cantilever were fabricated for both models. A clip-retained and a plunger-retained (SwissLoc) prosthesis were fabricated as superstructures for each framework. Vertical loads of 15 and 30 pounds were applied unilaterally to the first molar and 15 pounds to the first premolar on each of the 4 standardized overdenture prostheses. The cantilever was removed from the 2-implant framework and the clip-retained prosthesis was loaded similarly on the first molar with 25 pounds. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. RESULTS: While all 4 prostheses demonstrated low stress transfer to the implants, the plunger-retained prosthesis caused more uniform stress distribution to the ipsilateral terminal abutment compared to the clip-retained prosthesis and provided retention security under tested loads. The plunger-retained prosthesis retained by 2 implants provided better load sharing from the ipsilateral edentulous ridge than the clip-retained prosthesis retained by 3 implants, and lower resultant stresses were seen on the implants. CONCLUSIONS: Under load, all prosthetic designs demonstrated a low stress transfer to the ipsilateral abutment and to the contralateral side of the arch. The plunger-retained prosthesis retained by 2 implants demonstrated a more uniform stress transfer to the ipsilateral terminal abutment than the clip-retained prosthesis retained by 3 implants and provided more retention, given the implant configuration, prosthetic design and arch form.

Compressive Strength↗

1997 Judson C. Hickey Scientific Writing Awards. Lip prosthesis retained with resin-bonded retentive elements as an option for the restoration of labial defects: a clinical report.

Surgical resection of the lips is a relatively uncommon procedure, and it usually presents surgical and prosthodontic rehabilitation challenges. The goals of prosthetic treatment include regaining favorable speech and restoration of esthetics. This clinical report described a method for fabricating a lip prosthesis that uses resin-bonded retentive elements bonded to the patient's teeth for retention. Clinical and laboratory procedures of the prosthetic treatment were described, and the advantages and disadvantages were reviewed.

Acrylic Resins↗

[Complete overdenture retained with implants and bar-clip attachments].

OBJECTIVE: To sum up and evaluate the applied experience and applied effects of implants and bar-clip attachments in complete overdenture. METHODS: Bar-clip attachments were used as a super structure of implant to manufacture complete overdenture in three designs: mucosa, implant-mucosa, and implant supporting way. The retentive force of the overdenture was measured with measuring instrument of retentive force of prosthesis. RESULTS: All three designs could obtain good retentive effect, specially implant-mucosa supporting and implant supporting designs, which were of more better stability and supporting effect; 2-3 nelon clips could supply 10-15 N retentive force to the overdenture. CONCLUSION: The complete overdenture retained with implant and bar-clips attachments is a very effective way for restoration of endtulous patients, which should be applied more popularly.

Dental Implants↗

Alternative retention for an implant-retained auricular prosthesis.

The introduction of intraoral endosseous implants was inevitably followed by their external use in maxillofacial prosthodontics. Bar and clip attachments provide satisfactory retention for auricular prostheses, although the bar may inhibit patient hygiene by limiting access to the defect area. A simple clinical and laboratory technique to enhance the retention of an implant-retained auricular prosthesis is described, with custom-made stud attachments used for retention. Improved access for hygiene is provided. A clinical case is presented.

Adult↗

Prolonged suppressive antibiotic therapy for infected orthopedic prostheses.

Prolonged suppressive antibiotic therapy may be an alternative to removal of infected orthopedic prostheses in some patients. However, the efficacy of prolonged suppressive antibiotics is not well established. We retrospectively reviewed 18 patients with infected orthopedic prostheses who had been treated with prolonged antimicrobial suppression during the last 10 years. Eighteen episodes of infection were identified in these 18 patients. There were nine men and nine women, and the mean age was 66 years (range, 31-83 years). All patients had a functional prosthesis and were treated with surgical debridement, retention of the prosthesis, and administration of intravenous antibiotics for 6-8 weeks, followed by prolonged oral antibiotic suppression. Fifteen of the 18 patients appear to have had a good response and have been able to retain a functional prosthesis. Complications related to antibiotic suppression occurred in 22% but did not necessitate discontinuation of the antibiotic therapy. Prolonged antibiotic suppression is a reasonable alternative to surgery in selected patients with infected orthopedic prostheses.

Adult↗

Infection after total knee arthroplasty. A retrospective study of the treatment of eighty-one infections.

BACKGROUND: The clinical presentation of an infection at the site of a total knee arthroplasty can be used as a guide to treatment, including the decision as to whether the prosthesis should be retained or removed. We reviewed the results of treatment of infection after total knee arthroplasty to evaluate the effectiveness of four treatment protocols based on the clinical setting of the infection. METHODS: We retrospectively evaluated the results of treatment of eighty-one infections in seventy-six consecutive patients who either had an infection after a total knee arthroplasty or had multiple positive intraoperative cultures of specimens of periprosthetic tissue obtained during a revision total knee arthroplasty performed because of presumed aseptic loosening. The patients were managed according to one of four protocols. Five infections in five patients who had positive intraoperative cultures were treated with antibiotic therapy alone. Twenty-three early postoperative infections in twenty-one patients were treated with débridement, antibiotic therapy, and retention of the prosthesis. Twenty-nine late chronic infections in twenty-eight patients were treated with a delayed-exchange arthroplasty after a course of antibiotics. Seven acute hematogenous infections in six patients were treated with débridement, antibiotic therapy, and retention of the prosthesis. Seventeen infections in seventeen patients were not treated according to one of the four protocols. Sixteen late chronic infections were treated either with an arthrodesis (five infections) or with débridement, antibiotic therapy, and retention of the prosthesis (eleven infections). One acute hematogenous infection was treated with resection arthroplasty because of life-threatening sepsis. RESULTS: The mean duration of follow-up was 4.0 years (range, 0.3 to 14.0 years). Eleven patients who had an arthrodesis, a resection arthroplasty, or an above-the-knee amputation after less than two years of follow-up were included in the study as individuals who had a failure of treatment. In the group of patients who were managed according to protocol, the initial course of treatment was successful for all five infections that were diagnosed on the basis of positive intraoperative cultures, five of the ten deep early infections, all thirteen superficial early infections, twenty-four of the twenty-nine late chronic infections, and five of the seven acute hematogenous infections. Only one of eleven prostheses in patients who had a late chronic infection that was not treated according to protocol was successfully retained after débridement. CONCLUSIONS: Our treatment protocols, which were based on the clinical setting of the infection, were successful for most patients. A major factor associated with treatment failure was a compromised immune status. Bone loss and necrosis of the soft tissues around the joint also complicated the treatment of these infections.

Aged↗

Arthroscopic debridement in the treatment of the infected total knee replacement.

Infection is a potentially disastrous complication of total knee replacement (TKR). Retention of the prosthesis has been associated with high rates of persistent infection. Our study shows that in selected situations, arthroscopic debridement may allow retention of the prosthesis and eradication of the infection. However, the prosthesis must be stable, the surgical technique must be meticulous and specific antibiotics must be taken for a lengthy period. Arthroscopic debridement should be considered as an alternative to an open technique, or revision, for the infected TKR.

Aged↗

[Forces at the implant-bone interface of condylar knee prosthesis--with special reference to the retention of the posterior cruciate ligament].

Breakdown of the implant-bone interface is the most important factor limiting the effective life of total joint replacement. A particular example is the tibial component of the knee prosthesis which interfaces with trabecular bone. It is postulated that one of the major reasons for interface breakdown is excessive shear, compressive and moment stresses at the implant-bone interface. These stresses can be greatly influenced by the design of the prostheses, namely surface contour of the tibial component and the retention of the posterior cruciate ligament. Forces across the tibial component-bone interface was measured for prostheses both retaining and sacrificing the posterior cruciate ligament and for partially conforming and non-conforming, flat geometries. The results are as follows: Shear force, normal force and moment force across the interface were significantly greater for the prostheses sacrificing the posterior cruciate ligament than for those retaining it. Moment force was markedly greater for the tibial component with anterior curvature than for flat tibial component. It was suggested from this experiment that the knee prosthesis should retain the posterior cruciate ligament and the surface of the tibial component should probably be flatter for reducing the forces at the implant-bone interface.

Biomechanical Phenomena↗

Treatment of infection with débridement and retention of the components following hip arthroplasty.

Forty-two patients (forty-two hips) who had an infection following a hip arthroplasty were managed with open débridement, retention of the prosthetic components, and antibiotic therapy. After a mean duration of follow-up of 6.3 years (range, 0.14 to twenty-two years), only six patients (14 per cent) -- four of nineteen who had had an early postoperative infection and two of four who had had an acute hematogenous infection -- had been managed successfully. Of the remaining thirty-six patients, three (7 per cent of the entire group) were being managed with chronic suppression with oral administration of antibiotics and thirty-three (79 per cent of the entire group) had had a failure of treatment. All nineteen patients who had a late chronic infection were deemed to have had a failure of treatment. Débridement had been performed at a mean of six days (range, two to fourteen days) after the onset of symptoms in the patients who had been managed successfully and at a mean of twenty-three days (range, three to ninety-three days) in those for whom treatment had failed. Débridement with retention of the prosthesis is a potentially successful treatment for early postoperative infection or acute hematogenous infection, provided that it is performed in the first two weeks after the onset of symptoms and that the prosthesis previously had been functioning well. In our experience, this procedure has not been successful when it has been performed more than two weeks after the onset of symptoms. Retention of the prosthesis should not be attempted in patients who have a chronic infection at the site of a hip arthroplasty as this approach universally fails.

Adult↗

Residual facial disfigurement after the ablative surgery of a lachrymal gland carcinoma: a clinical report of the prosthetic rehabilitation.

Facial disfigurement after ablative surgery of a massive adeno-carcinoma of the lachrymal gland is described. A rehabilitation with a maxillofacial prosthesis was proposed to restore the aesthetic appearance of the patient without inserting craniofacial implants. Retention of a maxillofacial prosthesis, that is not anchored to implants, depends on the use of adhesives or on mechanical devices like glasses. This clinic report describes a residual anatomic defect which allowed for the double choice of wearing the facial prosthesis both with or without glasses. A retentive backside of the prosthesis was developed to engage the facial defect undercuts, which enhanced retention when the patient used the skin glue without glasses. A unique foam silicone was utilized to reduce the weight of the prosthesis and to permit its retention only by skin adhesive.

Adenocarcinoma↗

Gastrocnemius muscle flap coverage of exposed or infected knee prostheses.

A retrospective analysis was performed of 12 patients who required soft-tissue coverage of an exposed or infected total knee prosthesis between 1982 and 1989. All knees had skin closure with medial gastrocnemius muscle flaps. At a mean follow-up period of 41 months, all patients who were treated for infected prostheses with removal of the implant, intravenous antibiotics, and muscle flap closure had an excellent clinical result with complete skin coverage and no infection. Five of the six patients went on to successful reimplantation. Of the patients with an exposed prosthesis, five of six had an excellent outcome with retention of the prosthesis. Thus, 11 of 12 patients (92%) who had medial gastrocnemius flap coverage of an exposed or infected knee prosthesis had an excellent outcome, with ten of 12 patients (82%) retaining their prostheses or having a successful reimplantation. No medial gastrocnemius flap failed after standard primary or revision total knee arthroplasty. Gastrocnemius muscle flaps provide excellent soft-tissue coverage of exposed or infected knee prostheses and facilitate surgical care of this difficult problem.

Adolescent↗

Prosthetic joint infection: when can prosthesis salvage be considered?

Management of prosthetic joint infection (PJI) remains a therapeutic challenge. We retrospectively studied 69 infected total hip or knee arthroplasties managed between 1980 and 1996 in our institution. Treatment failure, defined as relapse of PJI in the first year following the last antimicrobial treatment, occurred for 14 patients (20.3%). None of the potentially contributive parameters analyzed was significantly predictive of treatment failure. Of the subgroup of 34 patients with PJI who initially underwent debridement with retention of the prosthesis, the 13 (38.2%) who did not require further surgical treatment had symptoms for a significantly shorter duration before debridement (4.85 vs. 54.24 days; P < .0001). Because debridement with retention of the prosthesis rarely enables control of PJI, this therapeutic approach should be considered only when the duration of symptoms is very short.

Adult↗

Complete denture with a removable palatal lift prosthesis: a case report and clinical evaluation.

The palatal lift prosthesis is used to alleviate rhinopharyngeal closure dysfunction. It is generally problematical to use in edentulous patients, because the palatal lift prosthesis requires secure retention of the denture base and is difficult for the patient to retain while eating. This article describes the fabrication of a complete denture with a removable palatal lift prosthesis and a clinical evaluation of the denture's stability. A sprue pin and tube were used as a connecting attachment between the removable palatal lift prosthesis and the denture base. The force required for lifting the soft palate and the denture's stability were measured in the clinical evaluation. The prosthesis required an average retentive force of 0.26 N for each 1 mm of soft palate lift. The force required to dislodge the denture was measured with and without the palatal lift prosthesis in place. The force required to dislodge the conventional complete dentures of five healthy individuals was also measured as a reference. The denture was 24.4% less stable when the palatal lift prosthesis was in place and was generally easier to dislodge than were conventional dentures. This denture with a removable palatal lift prosthesis is useful for patients with dysfunction of the soft palate involving hypernasal speech who have difficulty in retaining the prosthesis while eating.

Adult↗

Influence of clasp design of distal extension removable partial dentures on the periodontium of the abutment teeth.

Three removable partial denture designs were investigated to determine the effect of minor connector configuration on the periodontal health of abutment teeth. Twenty-five patients wore three different removable partial dentures for 19 weeks each. The first removable partial denture placed a tilting force on the abutment teeth; the second was stress-releasing; and the third collected the least amount of plaque. Plaque accumulation, the condition of the periodontium, migration of the abutment teeth, deformation of the clasp arms, retention of the prosthesis, and patient preferences were assessed. The results demonstrated that the partial denture retentive design did not affect plaque formation. The prosthesis designed to place a tilting force on the abutment teeth appeared to cause the least mobility and migration of the abutments and had the greatest acceptance by the patients.

Dental Abutments↗