Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Intubation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75Linked to original sources

Pathological changes associated with short-term nasal intubation.

In order to define the incidence and anatomical site of nasal damage following nasotracheal intubation, we investigated 100 consecutive patients undergoing dental extractions under general anaesthesia. Patients were questioned pre-operatively about the physiological function of their noses and examined by anterior rhinoscopy for anatomical abnormalities. Examinations were repeated postoperatively, looking specifically for haemorrhage, mucosal tears and septal and turbinate disruption. Minor bruising was common (54%) and most frequently involved mucosa overlying the inferior turbinate and adjacent septum. In two cases bruising involved the middle turbinate. There was no relationship between the number of attempts at intubation and subsequent damage. Pre-operative otolaryngological assessment failed to identify those patients who subsequently proved difficult or impossible to intubate nasally and incorrectly predicted difficulty in 11 patients who had pre-existing deviation of the nasal septum. In conclusion, short-term nasotracheal intubation was not associated with significant nasal morbidity, and pre-operative anatomical assessment failed to identify those in whom nasal intubation proved difficult or impossible.

Adolescent↗

Dose-response and minimum time to satisfactory intubation conditions after mivacurium in children.

We assessed neuromuscular blocking effects and tracheal intubation conditions following mivacurium in 121 anaesthetised children aged 1-10 years. The study was conducted in three parts. Parts 1 and 2 were undertaken during thiopentone-alfentanil-nitrous oxide anaesthesia; neuromuscular blockade was evaluated by recording the force of contraction of the adductor pollicis in response to train-of-four stimulation at 0.1 Hz. In part 1 the potency of mivacurium was determined in 15 children using a single dose-response technique; in part 2 onset and recovery times were determined in six children following a dose of mivacurium 0.2 mg.kg-1. In part 3 of the study, clinical intubation conditions were assessed in two groups of 50 children whose tracheas were intubated 60 or 90 s after injection of mivacurium 0.2 mg.kg-1 during thiopentone-nitrous oxide anaesthesia. The ED50 and ED95 of mivacurium were 54 and 105 micrograms.kg-1 respectively. The times to 90% and 100% depression of control twitch were 1.3 (0.3) and 1.9 (0.5) min; times to 5%, 25%, 75% and 90% recovery were 6.4 (1.0), 8.4 (1.1), 12.5 (1.1) and 14.4 (1.9) min, respectively. Intubation conditions were rated satisfactory in 33/50 children (0.66, 95% confidence interval 0.51-0.79) at 60 s and in 49/50 children (0.98, 95% confidence interval 0.89-1.0) at 90 s (p = 0.0001). Intubation conditions 90 s after mivacurium 0.2 mg.kg-1 were significantly better than those obtained in 10 patients given anaesthetic drugs alone (p = 0.002).

Alfentanil↗

Tracheal intubation conditions after one minute: rocuronium and vecuronium, alone and in combination.

Rocuronium is a recently introduced nondepolarising neuromuscular blocking agent with a rapid onset and intermediate duration of action. Experimental observations have suggested that during onset it acts synergistically with other nondepolarising agents, but that at a steady state the combined action is additive. In order to investigate whether synergism during onset produces a clinical benefit we performed the following study of tracheal intubation conditions. Consenting patients presenting for elective surgery which required tracheal intubation were randomly allocated to receive a standard anaesthetic and either a twice ED95 dose of rocuronium, or vecuronium, or an equipotent mixture of both drugs. Tracheal intubation conditions were assessed after 60 s and scored as excellent, good, poor or impossible. The conditions produced in the rocuronium and the mixture groups were similar and both were significantly better than those of vecuronium. Excellent intubation conditions were achieved in 57% of the rocuronium group, 70% of the mixture group and 27% of the vecuronium group. We conclude that a mixture of rocuronium and vecuronium acts synergistically during the early part of their action and a mixture containing one ED95 of both agents provides comparable conditions for tracheal intubation as an equipotent dose of rocuronium.

Adult↗

Intubating conditions using cisatracurium after induction of anaesthesia with thiopentone.

We studied tracheal intubation conditions produced by the muscle relaxant, cisatracurium, following induction of anaesthesia with fentanyl (2 micrograms.kg-1) and thiopentone (6 mg.kg-1). Sixty patients were randomly assigned to receive cisatracurium in a single bolus dose of either 0.15 or 0.20 mg.kg-1. Tracheal intubation was commenced 120 s after injection of the relaxant. The mean (SD) time taken to achieve intubation was significantly shorter in the 0.20 mg.kg-1 group (137 (16) s) than the 0.15 mg.kg-1 group (149 (12) s; p < 0.05). The intubating conditions were better after the larger dose. Our results suggest that when anaesthesia is induced using thiopentone, a dose of 0.20 mg.kg-1 of cisatracurium is recommended to ensure satisfactory intubating conditions.

Adult↗

Airway auscultation. A new method of confirming tracheal intubation.

Unrecognised accidental oesophageal intubation remains an important cause of morbidity and mortality in anaesthetic practice. We have evaluated a new method of distinguishing tracheal from oesophageal intubation using a simple adaptation of an ordinary stethoscope which is inserted into the patient end of the breathing system. We call this technique 'airway auscultation'. Characteristic sounds are heard with the stethoscope during inflation and deflation which allow the observer to diagnose the position of the tube. When the tube is in the trachea loud breath sounds are heard. In contrast, when the tube is in the oesophagus either squeaks or a flatus-like noise is heard or else there is no sound. In 100 healthy adults two observers rapidly identified 99 intubations correctly in a randomised single-blind trial. We recommend further widespread evaluation of this device as it appears to be an effective, simple and rapid method of detecting oesophageal intubation and confirming tracheal intubation which may be of particular use in situations where capnography is not available.

Adolescent↗

Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope.

The movements of the upper cervical spine were measured by fluoroscopy in 20 patients during laryngoscopy with the Bonfils intubation fibrescope and the Macintosh laryngoscope. Laryngoscopy with both the Bonfils intubation fibrescope and the Macintosh laryngoscope resulted in significant extension of the cervical spine as compared to the neutral position but this extension was significantly less with the Bonfils intubation fibrescope than with the Macintosh (p = 0.001). However, the atlanto-occipital distance was significantly greater during laryngoscopy with the Bonfils intubation fibrescope (p = 0.002), and the angle between the occiput and C1 differed significantly between the two techniques (p = 0.001). With the Bonfils intubation fibrescope, significantly less extension was also found at the C1/C2 and C3/C4 levels (p = 0.001 and p = 0.049, respectively). There is therefore significantly less movement of the upper cervical spine during laryngoscopy with the Bonfils fibrescope compared with the Macintosh laryngoscope.

Adult↗

Tracheal intubation using the ILMA, C-Trach or McCoy laryngoscope in patients with simulated cervical spine injury.

A study of 90 patients was undertaken to compare intubation success rates of using either ILMA, C-Trach or McCoy laryngoscope in patients with simulated cervical spine injury. Insertion and intubation success rates, time taken to achieve intubation, airway complications and haemodynamic parameters were recorded. Insertion of ILMA and C-Trach was successful at the first attempt in all patients. Intubation success rates were higher in the C-Trach (100%) and McCoy (100%) groups than in the ILMA (87%) group. Total intubation time was significantly longer in the ILMA (63 s, SD 36.5) group than in the C-Trach (41 s, SD 15.8) and McCoy (30 s, SD 7.4) groups (p < 0.05, p < 0.05, respectively). There were no significant differences in haemodynamic parameters among the groups at any time.

Adult↗

A comparison of intubating conditions in children following induction of anaesthesia with propofol and suxamethonium or propofol and remifentanil.

Sixty ASA 1 and 2 children aged between 2 and 16 years who required tracheal intubation as part of anaesthesia for elective surgery were studied. We evaluated intubating conditions, haemodynamic responses and duration of apnoea following propofol 4 mg.kg-1 combined with either remifentanil 1.25 microg.kg-1 (group R), or suxamethonium 1 mg.kg-1 (group S). Tracheal intubation was graded as excellent, good or poor according to ease of laryngoscopy, vocal cord position, coughing, and jaw relaxation and limb movement. Thirty of group S and 28 of group R children were successfully intubated on the first attempt. Overall, intubation conditions were excellent or good in 26/30 (87%) patients in group S and 20/30 (67%) in group R (p<0.05). Mean apnoea time was 190 s in group S, and 362 s in group R (p<0.001). Heart rate increased in response to suxamethonium (p<0.01) and both systolic and diastolic blood pressure decreased in the remifentanil group (p<0.01).

Adolescent↗

Acute epiglottitis in children: experiences with tracheotomy and intubation.

Acute epiglottitis is one of the most serious and potentially fatal conditions dealt with in paediatric laryngology. The infectious agent is mostly Haemophilus influenzae. An active and planned treatment to secure the airway is necessary to reduce the morbidity and mortality. The 'watch and wait' attitude should be abandoned. Tracheotomy or intubation should be performed. Mostly literature today is in favour of intubation. However, both tracheotomy and intubation can be used, and if properly managed the complication rate with both methods is low. This series comprised 102 children of whom 79 were tracheotomized and 23 were intubated. No differences could be found between intubation or tracheotomy time (2.3 and 2.9 days respectively) or in hospital stay (6.7 and 6 days). The complication rate was low in both groups except for subcutaneous and mediastinal emphysema in the tracheotomy group but these did not cause any serious problems.

Adolescent↗

Dental complications associated with repeated orotracheal intubation in infancy: a case report.

Various oral and dental problems have been attributed to orotracheal intubation in the neonatal period. A case is described of a child whose dental anomalies are ascribed to multiple orotracheal intubations for the management of a complex cardiac abnormality. Six intubations were required between the ages of 9 days and 4 years for investigation and surgery. His maxillary right primary central incisor did not erupt until 3 years of age and the maxillary left was still unerupted at 6 years and 10 months and was rotated in its crypt. At this time, the mandibular primary incisors were physiologically mobile but the maxillary right primary central incisor remained firm. Both maxillary primary central incisors were extracted and examined histologically and showed abnormal morphology, enamel hypoplasia, and disordered dentine formation and root resorption. Subsequent eruption of the left permanent central incisor revealed hypoplasia of its incisal edge. It is suggested that the delayed eruption and abnormal morphology of the primary incisors were due to pressure effects on the overlying mucosa, follicular displacement and localized trauma caused by intubation. This case highlights the importance of monitoring the developing dentition of patients with a history of orotracheal intubation, so that interceptive treatment may be instituted when appropriate.

Dental Enamel Hypoplasia↗

Mucus transport and surface damage after endotracheal intubation and tracheostomy. An experimental study in pigs.

The effects on mucus transport of different grades of tracheal injury produced experimentally by an intubation tube were studied in 26 pigs. Two of them were not intubated and served as controls, while the rest were anaesthetized and either intubated or tracheostomized, or both, and ventilated for approximately 4.5 h. They were then killed and the trachea and larynx were immediately removed and placed in a specially designed chamber at 37 degrees C and 85% relative humidity. Cardio-green dye was deposited caudally in the trachea as a mucus marker. The mucus transport was observed macroscopically and the ultrastructure of the tracheal wall at the region of mucus arrest was studied by light microscopy and scanning and transmission electron microscopy. In non-intubated pigs the mucus was transported to the posterior larynx. The ciliated epithelium was usually intact along the pathway where cardio-green-stained mucus had travelled. In pigs which had been intubated and/or tracheostomized, mucus transport stopped completely at different levels of the trachea. The damage to the ciliated epithelium varied; in some animals there was almost none at all and in others there was a patchy loss of a large proportion of the cilia, or complete lack of cilia. Lesions which also included epithelial cells were often seen. Tracheal injury due either to a cuffed endotracheal tube or to a tracheostomy tube, with destruction of epithelium and cilia, causes a barrier to mucus transport, leading to arrest and accumulation of mucus further down in the airway. We were unable, however, to demonstrate a direct correlation between grade of damage and tendency to mucus arrest.

Animals↗

Tracheal intubation after induction of anaesthesia with thiopentone or propofol without muscle relaxants.

This study was designed to compare the ease of performing laryngoscopy and endotracheal intubation without muscle relaxants after the induction of anaesthesia with either thiopentone or propofol in 106 patients scheduled for elective surgery. Thiopentone (5 mg/kg) or propofol (2.5 mg/kg), supplemented with lidocaine (1.5 mg/kg) and alfentanil (30 micrograms/kg), were used in random order for the induction of anaesthesia. Jaw tone, visualisation of the larynx, position of vocal cords, ease of intubation and tolerance of the tracheal tube were assessed. The jaw was relaxed and the vocal cords were immobile/open in most patients in both groups. Visualisation of the larynx was good in 60 and 46% and intubation was easy in 48 and 22% of the patients given thiopentone and propofol, respectively (P less than 0.05 between groups for intubation). After induction of anaesthesia with thiopentone or propofol, endotracheal intubation is not recommended without the use of muscle relaxants.

Adult↗

Haemodynamic responses and prolongation of QT interval of ECG after suxamethonium-facilitated intubation during anaesthetic induction in children: a dose-related attenuation by alfentanil.

The haemodynamic response to endotracheal intubation and changes in the QT interval of ECG during anaesthetic induction were studied in 68 healthy children (5.5 years). The children were pretreated double-blindly with either alfentanil 10 micrograms/kg (A10), 25 micrograms/kg (A25), 50 micrograms/kg (A50) or saline (control) (17 children in each group) i.v. 1 min before thiopentone 5 mg/kg. The trachea was intubated after suxamethonium 1.5 mg/kg. Central nervous system excitation was seen in four of 17 and in one of 17 children after alfentanil 50 and 25 micrograms/kg, respectively. After intubation, heart rate increased significantly in the control group, remained at initial levels in the A10 and A25 groups and decreased in the A50 group. A pressor response to intubation was seen in the control and A10 groups. The QT interval was significantly prolonged after suxamethonium in the control and A10 groups, but remained at baseline levels in the A25 and A50 groups. Ventricular ectopic beats were only seen in 2/17 children in the control group. In conclusion, alfentanil 25 microgram/kg is ideal for preventing the haemodynamic response to endotracheal intubation and prolongation of the QT interval, a sign of sympathoadrenal activation, before induction of intravenous anaesthesia in children.

Alfentanil↗

Isoflurane in nitrous oxide and oxygen increases plasma concentrations of noradrenaline but attenuates the pressor response to intubation.

The haemodynamic response to laryngoscopy and intubation was evaluated in 52 ASA I patients anaesthetized with thiopentone 4-6 mg.kg-1. Vecuronium 0.1 mg.kg-1, followed by 3 min mask ventilation with nitrous oxide in oxygen with (isoflurane group) or without (control group) 3% inspired isoflurane preceded tracheal intubation. In 21 of 52 patients, concentrations of noradrenaline (NA), adrenaline and 3,4-dihydroxyphenylethyleneglycol (DHPG) were measured from central venous plasma. During the 3-min ventilation, in the isoflurane group, heart rate increased by 22% but remained stable in the control group. A marked pressor response to laryngoscopy and intubation was seen in the control but not in the isoflurane group. During the 3-min ventilation, the plasma concentration of NA was doubled in the isoflurane group and increased by 49% in the control group (P less than 0.05). The concentration of DHPG also increased in the isoflurane group. Peripheral skin temperature increased similarly after 3 min ventilation in both groups. After intubation, it was significantly higher in the isoflurane than in the control group (P less than 0.05). In conclusion, compared to nitrous oxide in oxygen, ventilation with isoflurane in nitrous oxide in oxygen causes a sympathetic activation combined with an increase in heart rate and peripheral temperature while the pressor response to laryngoscopy and intubation is attenuated.

Adult↗

Intubating conditions and onset of neuromuscular block of rocuronium (Org 9426); a comparison with suxamethonium.

The intubating conditions and neuromuscular blocking profile following 600 micrograms.kg-1 rocuronium (Org 9426) have been investigated in patients under various experimental conditions. They were compared with conditions following 1.5 mg.kg-1 suxamethonium, preceded by a precurarising dose (10 mg) of gallamine, and with those in a control group in the absence of a muscle relaxant. Rocuronium produced good to excellent intubating conditions at 60 as well as at 90 s after administration, even though there was only a partial blockade of the adductor pollicis muscle. Intubating conditions following suxamethonium were comparable with those after rocuronium. Half of the control patients could be intubated. The clinical duration and the recovery time of 600 micrograms.kg-1 of rocuronium were 24(4) and 9(3) min (mean(s.d.)), respectively. Rocuronium may have a major advantage over existing non-depolarising muscle relaxants due to the early presence of excellent intubating conditions. The results indicate that rocuronium may replace suxamethonium in procedures in which rapid sequence induction is required.

Adult↗

High-dose vecuronium may be an alternative to suxamethonium for rapid-sequence intubation.

Endotracheal intubation conditions 60 s after intravenous administration of either high-dose vecuronium (0.3 mg kg -1; n = 25) or suxamethonium (1.0 mg kg -1; n = 25) were compared in a blind, randomised study. No significant differences were found between the two drugs. In 96% of the patients intubation conditions were characterized as excellent or good. In only one patient (4%) in each group were intubation conditions unsatisfactory. According to our findings, high-dose vecuronium provides satisfactory intubation conditions after 60 s and may be used instead of suxamethonium for rapid sequence intubation when a long duration of neuromuscular blockade is acceptable.

Adolescent↗

Attenuation of the pressor response to tracheal intubation with oral nitrendipine.

The effect of nitrendipine on the cardiovascular responses to tracheal intubation was studied in a placebo-controlled, randomised, double-blind trial. Thirty patients (ASA physical status 1) undergoing elective surgery received either 5 or 10 mg nitrendipine, or a placebo orally 3 h before induction of anaesthesia (n = 10 for each group). Anaesthesia was induced with sodium thiopentone 5 mg/kg i.v. and tracheal intubation was facilitated with vecuronium 0.2 mg/kg i.v. Patients receiving the placebo showed a significant increase in the mean arterial pressure and the rate-pressure product in response to tracheal intubation. These increases following intubation were reduced in nitrendipine-treated patients compared with the placebo group (P < 0.05). Oral administration of nitrendipine (5 or 10 mg, 3 h before induction of anaesthesia) was able to attenuate the hypertensive response to tracheal intubation in ASA 1 patients under light anaesthesia. We propose this pharmacological technique with supplementary doses of opioids and/or benzodiazepines for the management of patients with hypertension or coronary artery disease.

Administration, Oral↗

Use of the laryngeal mask for fibrescope-aided tracheal intubation in an awake patient with a deviated larynx.

I report a case in which fibrescope-aided awake tracheal intubation was achieved using a laryngeal mask, in a patient with a mediastinal goitre in whom tracheal intubation with both a laryngoscope and a fibreoptic bronchoscope had failed. The tumour extended to the upper part of the mediastinum. The larynx and the upper segment of the trachea were displaced by the tumour. Awake tracheal intubation with both a laryngoscope and a fibreoptic bronchoscope failed. The laryngeal mask was then inserted without difficulty. After a fibreoptic bronchoscope had been covered by a plastic tube, the combination was passed through the laryngeal mask into the trachea. The fibreoptic bronchoscope and the laryngeal mask were removed, and a reinforced endotracheal tube was then inserted over the plastic tube into the trachea. The time for tracheal intubation was about 70 s. The laryngeal mask may allow easier location of the laryngeal inlet with a fibreoptic bronchoscope, and this technique is a useful alternative to the conventional technique of tracheal intubation in the patient with a deviated larynx.

Aged↗