Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75Linked to original sources

Study of the catalytic effect of PAR on the luminol-potassium ferricyanide reaction using a flow-injection chemiluminescence method.

We discovered that 4-(2-pyridylazo) resorcinol (PAR) has a strong catalytic effect on luminol-potassium ferricyanide chemiluminescence (CL). Results indicated that the chemiluminescence intensities at maximum light emission were linearly corrected with the concentration of PAR over the range 1.0 x 10(-5)-1.0 x 10(-7) mol/L. A detection limit of 5.7 x 10(-8) mol/L for PAR was achieved. It was found that some metal ions strongly affected this catalytic reaction. Based on this finding, the luminol-potassium ferricyanide-PAR reaction was developed for the determination of metal ions. The detection limits (S/N = 3) for Ni2+, Cr3+, Zn2+, Co2+ and Mn2+ were determined to be 1.0 x 10(-9) mol/L, 5.0 x 10(-9) mol/L, 5.0 x 10(-8) mol/L, 1.0 x 10(-9) mol/L and 1.0 x 10(-8) mol/L, respectively. In addition, the relative standard deviation values for these metal ion assays were in the range 0.82-2.72% (n = 6).

Catalysis↗

Determination of bisphenol A using a flow injection inhibitory chemiluminescence method.

A new flow injection chemiluminescence (CL) method has been developed for the determination of bisphenol A (BPA), based on the inhibitory effect of BPA on the chemiluminescence reaction between luminol and potassium hexacyanoferrate. Under optimum conditions, the decrease in CL emission intensity was linear with BPA concentration in the range 8.0 x 10(-7)-1.2 x 10(-5) mol/L, and the detection limit was 3.1 x 10(-7) mol/L. The relative standard deviation (RSD) of 11 replicate measurements was 2.6% for 2.0 x 10(-6) mol/L BPA (n = 11). The sampling frequency was calculated to be ca. 120/h. This method has been successfully used to determine the content of BPA in aqueous solution of polycarbonate materials. A brief discussion on the possible chemiluminescence reaction mechanism is presented.

Benzhydryl Compounds↗

Flow-injection electrogenerated chemiluminescence determination of fluoroquinolones based on its sensitizing effect.

A simple and sensitive flow-injection electrogenerated chemiluminescence (ECL) method for the determination of fluoroquinolones was developed. The method is based on the sensitizing effect of fluoroquinolones on the weak ECL signal of electrochemical oxidation of luminol on the surface of the platinum flake electrode in the medium of 0.1 mol/L Na2CO3-NaHCO3. At the optimum experimental conditions, the relative ECL intensity increased linearly with increasing fluoroquinolones concentration, in the ranges 1.0 x 10(-8)-2.0 x 10(-4) g/mL for norfloxacin, 5.0 x 10(-9)-6.0 x 10(-6) g/mL for oxfloxacin, 2.0 x 10(-8)-1.4 x 10(-5) g/mL for ciprofloxacin, 1.0 x 10(-8)-1.4 x 10(-5) g/mL for pefloxacin, and 1.0 x 10(-9)-1.0 x 10(-5) g/mL for enoxacin, with detection limits of 4.0 x 10(-9) g/mL, 2.0 x 10(-9) g/mL, 1.0 x 10(-8) g/mL, 8.0 x 10(-9) g/mL, and 8.0 x 10(-10) g/mL, respectively. The relative standard deviations were all less than 2.5% for the determination of 2.0 x 10(-6) g/mL fluoroquinolones (n = 11). The method was used to determine these medicines in pharmaceutical samples with satisfactory results.

Capsules↗

A novel flow-injection chemiluminescence system for the determination of guanine.

A novel flow-injection chemiluminescence (CL) method for the determination of guanine was developed. The procedure is based on the CL reaction of guanine with hydrogen peroxide in borax buffer (pH 8.5) with Co2+ as a catalyst. The calibration graph is linear within the range of 3 x 10(-7)-9 x 10(-5) g/mL. A detection limit of 1 x 10(-7) g/mL, along with a relative standard deviation of 2.23% (3 x 10(-7) g/mL guanine, n = 11), were obtained. The present procedure was applied to the measurement of guanine in urine with recoveries of 97.5-107.5%. A possible CL mechanism of the reaction system is proposed.

Buffers↗

Flow injection chemiluminescence determination of isoniazid using the lucigenin-periodate system.

A weak chemiluminescence (CL) signal was observed during the mixing of isoniazid with lucigenin in alkaline aqueous solution. The CL signal was enhanced more than 100 times in the presence of potassium periodate. This CL system was developed for the determination of isoniazid using a flow injection mode. The CL intensity is proportional to the concentration of isoniazid in the range 0.005-1.0 mg/L. The limit of detection is 0.0034 mg/L and the relative standard deviation is 2.0% for 0.2 mg/L isoniazid solution in 11 repeated measurements. The method was applied to the determination of isoniazid in pharmaceutical preparations and satisfactory results were obtained.

Acridines↗

Sensitive determination of synephrine by flow-injection chemiluminescence.

It was found that light emission produced by the oxidation of luminol by potassium ferricyanide in basic medium was enhanced by synephrine, an anti-obesity drug. The optimum conditions for this chemiluminescent reaction were studied in detail in a flow injection system and employed in a new, simple and rapid method for the determination of synephrine. A mechanism for this reaction is proposed, based on the chemiluminescence reaction spectra. In the optimum conditions, CL intensity is proportional to concentration of synephrine in the 0.008-1 microg/mL range. The limit of detection is 1.6 ng/mL for synephrine (3sigma), and the relative standard deviation (n = 11) is 2.6% for 0.5 microg/mL synephrine. The method was applied to the determination of synephrine in herbal products, citrus fruit and biological fluids. The recoveries were satisfactory (90-102%). The results given by the proposed method are in good agreement with those given by HPLC-UV.

Chromatography, High Pressure Liquid↗

Determination of tetracycline, chlortetracycline and oxytetracycline by flow injection with inhibitory chemiluminescence detection using copper(II) as a probe ion.

This paper reports an indirect flow-injection (FI) method for the determination of the tetracycline drugs (TCs), tetracycline (TC), chlortetracycline (CTC) and oxytetracycline (OTC), using copper(II) as a probe ion. The method was based on the inhibition caused by these TCs to the copper(II)-catalysed chemiluminescence (CL) reaction between luminol and H(2)O(2). The CL reaction was induced on-line and injection of the sample produced negative peaks as a result of the copper(II) complexation or displacement by the analytes. The height of the peaks was proportional to the drug concentration in the sample. The choice of the catalyst ion, the concentration of luminol, H(2)O(2) and copper(II) are discussed. The linear range was 3.6 x 10(-8)-1.0 x 10(-5), 1.1 x 10(-7)-1.0 x 10(-5) and 1.9 x 10(-7)-1.0 x 10(-5) mol/L for TC, CTC and OTC, respectively. The detection limit was 5.0 x 10(-9) mol/L for TC, 1.0 x 10(-8) mol/L for CTC and 2.0 x 10(-8) mol/L for OTC (3sigma), respectively. The method was applied to the determination of TCs in pharmaceutical preparations and human urine with recoveries in the range 95-105%.

Catalysis↗

Determination of thyroxine in pharmaceuticals using flow injection with luminol chemiluminescence inhibition detection.

A simple flow injection method is reported for the determination of thyroxine, based on its inhibition effect on luminol-iron(II) chemiluminescence in alkaline medium in the presence of molecular oxygen. The detection limits (2s) for d- and l-thyroxine are 0.08 and 0.1 mg/L, respectively, with a sample throughput of 100/h. The calibration data for d- and l-thyroxine over the range 0.2-1.0 mg/L gives correlation coefficients (r(2)) of 0.9915 and 0.984 with relative standard deviations (RSD; n = 4) in the range 1.2-2.8%. The effects of some organic compounds was studied on luminol-iron(II) CL system for thyroxine determination. The method was applied to pharmaceutical thyroxine tablets and the results obtained (in the range 50.5 +/- 2.0-51.6 +/- 1.2 microg l-thyroxine/tablet) were in reasonable agreement with the value quoted.

Flow Injection Analysis↗

On-line preparation of peroxymonocarbonate and its application for the study of energy transfer chemiluminescence to lanthanide inorganic coordinate complexes.

It has been shown that peroxymonocarbonate ion (HCO(4) (-)) is a potent oxidant. In this study, a flow-injection system was developed in order to prepare on-line HCO(4) (-) ion and the optimum conditions for the on-line preparation of HCO(4) (-) were studied in detail. We used 99% (13)C-enriched NaHCO(3) to examine peroxymonocarbonate by (13)C-NMR at 25 degrees C. An ultra-weak chemiluminescence (CL) was observed after mixing H(2)O(2) and sodium bicarbonate in an organic co-solvent that can accelerate the formation of HCO(4) (-) ion. When lanthanide inorganic coordinate complex, Eu(II)-EDTA, was added into this HCO(4) (-) system, the CL intensity was significantly enhanced. The CL mechanism was investigated by various methods. The experimental results indicate that peroxymonocarbonate oxidizes Eu(II) to Eu(III) and produces singlet oxygen; meanwhile, the energy originating from dimers of singlet oxygen is accepted by the Eu(III)-EDTA(-) complex. The excited Eu(III) ions undergo radiative deactivation and emit CL.

Carbonates↗

Determination of iodide using flow injection with acidic potassium permanganate chemiluminescence detection.

A simple and rapid flow-injection method is described for the determination of iodide, based on potassium permanganate chemiluminescence detection via oxidation of formaldehyde in aqueous hydrochloric acid. The calibration graph was linear over the range 1.0-12 x 10(-6) mol/L (r2 = 0.9955) with relative standard deviations (n = 4) in the range 1.0-3.5%. The detection limit (3sigma) was 1.0 x 10(-7) mol/L, with sample throughput of 120/h. The effect of interfering cations [Ca(II), Mg(II), Ni(II), Fe(II), Fe(III) and Pb(II)] and anions (Cl-, SO4(2-), PO4(3-), NO3-, NO2-, F- and SO3(2-)) were studied. The method was applied to iodized salt samples and the results obtained in the range 0.03 +/- 0.005 - 0.10 +/- 0.006 mg I/g were in reasonable agreement with the amount labelled. The method was statistically compared with the results obtained by titration; no significant disagreement at 95% confidence was observed.

Acids↗

A sensitive inhibition chemiluminescence method for the determination of trace tannic acid using the reaction of luminol-hydrogen peroxide catalysed by tetrasulphonated manganese phthalocyanine.

A novel CL method for the determination of tannic acid (TA) was established based on TA inhibition of the chemiluminescence (CL) emission of the luminol-hydrogen peroxide CL system catalysed by tetrasulphonated manganese phthalocyanine (MnTSPc) under alkaline conditions. The peak height is proportional to the natural logarithm of concentration of TA in the range 1.0 x 10(-7)-3.0 x 10(-10) mol/L with a detection limit of 5.6 x 10(-11) mol/L and the relative standard deviation was 2.5% for the determination of 1.0 x 10(-8) mol/L TA (n = 11). The proposed method has been successfully applied to the determination of TA in Chinese gall and industrial wastewater.

Catalysis↗

Catalytic effect of ferricyanide between myoglobin and luminol and effect of temperature.

Specific catalytic oxidation of oxymyoglobin (MbO(2)) and luminol by ferricyanide was studied in a flow-injection system. MbO(2) in different redox states (ferric and ferrous) was oxidized to Mb(Fe(III)) by ferricyanide, and then specific binding of the ferrocyanide anion to Mb(Fe(III)) to the His 119 (GH1) region accelerated the electron transfer between Mb(Fe(III)) and luminol, which produced a chemiluminescence (CL) signal at 425 nm. The increased CL emission was correlated with the myoglobin concentration in the range 0.16-7.5 microg/mL. Thermogravimetry and differential scanning calorimetry were used to investigate the temperature effects on this reaction. The results showed that the CL intensity in the presence of myoglobin changed considerably with heating in the range 15-50 degrees C, and the maximal CL intensity was observed at 40 degrees C, corresponding to the glass transition temperature of myoglobin. The effect of different ligands and interferences were also studied.

Catalysis↗

Chemiluminescence of synephrine based on the cerium(IV)-rhodamine B system.

A new chemiluminescence (CL) method is described for the determination of synephrine. It is based on the reaction between synephrine and Ce(IV) in a nitric acid medium and measurement of the CL intensity produced by rhodamine B used as a luminophore, similar to luminol or lucigenin in basic media, instead of as a sensitizer. In the optimum conditions, the increase of CL intensity was correlated with synephrine concentration over the range 5.0 x 10(-9)-1.0 x 10(-6) g/mL with a detection limit of 1.0 x 10(-9) g/mL. The relative standard deviation (RSD) was 2.9% for 1.0 x 10(-7) g/mL synephrine (n = 11). The method was applied to the determination of a drug in herbal products, citrus fruit and biological samples, with satisfactory results. The results given by the proposed method are in good agreement with those given by HPLC-UV and UV spectrophotometry.

Cerium↗

Miniaturized amperometric flow immunoassay system using a glass fiber membrane modified with anion.

This paper describes a miniaturized amperometric flow immunoassay system using a glass fiber membrane modified with anion. The glass fiber membrane was functionally modified with gamma-glycidoxypropyltrimethoxysilane and sodium thiosulfate and was used for separation of protein. Anti-human chorionic gonadotrophin (HCG) immunoglobulin G (IgG) antibody conjugated with ferrocenemonocarboxylic acid (Fc), namely, Fc-conjugated IgG (Fc-IgG), was used as a novel analytical reagent. HCG and Fc-IgG complexes were separated from free Fc-IgG based on differences in isoelectric point (pI) using the glass fiber membrane modified with a thiosulfonyl acid functional group. The assay yields a linear relationship between current and HCG concentration in the range of 0-2000 mIU/mL. This simple technique enables the assay of HCG within 2 min. The modified glass fiber membrane was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free Fc-IgG. Free Fc-IgG recovered in this manner could be reused up to eight times without significant decreases in sensitivity. This miniaturized amperometric flow immunoassay requires only minute quantities of serum and generates highly reproducible results.

Animals↗

Inhibitory effect of carbon dioxide on the fed-batch culture of Ralstonia eutropha: evaluation by CO2 pulse injection and autogenous CO2 methods.

In order to see the effect of CO(2) inhibition resulting from the use of pure oxygen, we carried out a comparative fed-batch culture study of polyhydroxybutyric acid (PHB) production by Ralstonia eutropha using air and pure oxygen in 5-L, 30-L, and 300-L fermentors. The final PHB concentrations obtained with pure O(2) were 138.7 g/L in the 5-L fermentor and 131.3 g/L in the 30-L fermentor, which increased 2.9 and 6.2 times, respectively, as compared to those obtained with air. In the 300-L fermentor, the fed-batch culture with air yielded only 8.4 g/L PHB. However, the maximal CO(2) concentrations in the 5-L fermentor increased significantly from 4.1% (air) to 15.0% (pure O(2)), while it was only 1.6% in the 30-L fermentor with air, but reached 14.2% in the case of pure O(2). We used two different experimental methods for evaluating CO(2) inhibition: CO(2) pulse injection and autogenous CO(2) methods. A 10 or 22% (v/v) CO(2) pulse with a duration of 3 or 6 h was introduced in a pure-oxygen culture of R. eutropha to investigate how CO(2) affects the synthesis of biomass and PHB. CO(2) inhibited the cell growth and PHB synthesis significantly. The inhibitory effect became stronger with the increase of the CO(2) concentration and pulse duration. The new proposed autogenous CO(2) method makes it possible to place microbial cells under different CO(2) level environments by varying the gas flow rate. Introduction of O(2) gas at a low flow rate of 0.42 vvm resulted in an increase of CO(2) concentration to 30.2% in the exit gas. The final PHB of 97.2 g/L was obtained, which corresponded to 70% of the PHB production at 1.0 vvm O(2) flow rate. This new method measures the inhibitory effect of CO(2) produced autogenously by cells through the entire fermentation process and can avoid the overestimation of CO(2) inhibition without introducing artificial CO(2) into the fermentor.

Bioreactors↗

Optimization of biomass, vitamins, and carotenoid yield on light energy in a flat-panel reactor using the A-stat technique.

Acceleration-stat (A-stat) cultivations in which the dilution rate is continuously changed at a constant acceleration rate, leading to different average light intensities inside the photobioreactor, can supply more information and reduce experimental time compared with chemostat cultivations. The A-stat was used to optimize the biomass and product yield of continuous cultures of the microalgae D. tertiolecta in a flat-panel reactor. In this study, four different accelerations were studied, a pseudo steady state was maintained at acceleration rates of 0.00016 and 0.00029 h(-2) and results were similar to those of the chemostat. An increase in the acceleration rate led to an increase in the deviation between results obtained in the A-stat and in the chemostats. We concluded that it is advantageous to use the A-stat instead of chemostats to determine culture characteristics and optimize a specific photobioreactor. The effect of average light intensity inside the photobioreactor on the production of vitamins C and E, lutein, and beta-carotene was studied using the A-stat. The highest concentrations of these products were 3.48 +/- 0.46, 0.33 +/- 0.06, 5.65 +/- 0.24, and 2.36 +/- 0.38 mg g(-1), respectively. These results were obtained at different average light intensities, showing the importance of optimizing each product on light intensity.

Ascorbic Acid↗

On-line monitoring of bioreductions via membrane introduction mass spectrometry.

Real-time and on-line continuous monitoring of reactants, intermediates, and final products for dicarbonyl compound bioreduction in a continuous plug flow reactor packed with baker's yeast (Saccharomyces cerevisiae) whole cells immobilized on calcium alginate beads was performed by membrane introduction mass spectrometry (MIMS) via selective ion monitoring.

Alcohol Oxidoreductases↗

Process hydraulics, distributed bacterial states, and biological phosphorus removal from wastewater.

Hydraulic characteristics of biological wastewater treatment systems were shown to affect bacterial state distributions and system performance through mathematical simulations. The term "state" is used here to mean the microbial storage product and biomass content of a bacterium. The traditional approach to simulating biological treatment processes assumes "lumped" (average) states, rather than accounting for variable states across bacterial populations. Distributed states were previously suggested as critical to enhanced biological phosphorus removal (EBPR), but the factors that cause distributed states were not evaluated. A primary driver for distributed state development is variable hydraulic experiences of bacteria as they cycle through completely mixed reactors, and so process characteristics that affect hydraulics were hypothesized to affect state distributions. Two design characteristics affecting system hydraulics were evaluated using a new distributed state simulation program (DisSimulator 1.0): total hydraulic residence time (HRT) and numbers of reactors in series. Distributed predictions consistently predicted worse EBPR performance than did the lumped approach. Increasing HRTs (with constant solids retention times) tended to increase state distributions, to increase the differences between lumped and distributed simulation predictions, and to decrease predicted EBPR performance. As the numbers of reactors in series increased, distributed predictions tended to converge with lumped simulation predictions. Distributed simulations tended to predict a greater benefit to using reactors in series than did lumped simulations. This work provides guidance for new strategies to improve EBPR by minimizing state distributions. The targeted hydraulic characteristics may be more important to EBPR than previously recognized due to their effects on distributed states.

Bacteria↗