Occupational gonadal and embryo/fetal doses from fluoroscopically assisted surgical treatments of spinal disorders.

STUDY DESIGN: Simulation of lumbar spine fluoroscopy used during surgical treatments of spinal disorders on a humanoid phantom and monitoring of the scattered radiation levels. OBJECTIVES: To assess the potential of adverse effects to progeny due to the preconceptual and embryo/fetal exposure to ionizing radiation resulting from the parental occupational exposure to scattered radiation from lumbar fluoroscopy. SUMMARY OF BACKGROUND DATA: There are no available data on embryo/fetal doses resulting from maternal occupational exposure in the orthopedic theater. Besides, studies on staff gonadal doses from fluoroscopically assisted spine surgery are scarce and their results are not generally applicable. METHODS: Lumbar spine anterior-posterior and lateral fluoroscopy were performed on an anthropomorphic phantom. Scattered radiation within the orthopedic theater was recorded at the staff genitals and waist level. Gonadal, abdominal surface, and embryo/fetal doses normalized to the dose-area-product specific to each projection were calculated. RESULTS: If the annual dose limits of occupational exposure are continuously exhausted for 10 years, the resulting radiogenic risk of congenital malformation in infants born to the orthopedic theater staff will be at least two orders of magnitude lower than the corresponding spontaneous probability. The occupational exposure of the pregnant mother bears a negligible contribution to the risk of hereditary effect on the newborn's progeny compared with the natural incidence rate. CONCLUSIONS: Radiogenic genetic and embryo/fetal risks resulting from occupational exposure due to fluoroscopically assisted surgical treatments of spinal disorders are well within tolerance levels provided that rigorous confinement to all pertinent occupational dose constraints is established.

Dose-Response Relationship, Radiation↗

Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose.

PURPOSE: To determine patient radiation doses for interventional radiology and neuroradiology procedures, to identify procedures associated with higher radiation doses, and to determine the effects of various parameters on patient doses. MATERIALS AND METHODS: A prospective observational study was performed at seven academic medical centers. Each site contributed demographic and radiation dose data for subjects undergoing specific procedures in fluoroscopic suites equipped with built-in cumulative dose (CD) and dose-area-product (DAP) measurement capability compliant with International Electrotechnical Commission standard 60601-2-43. The accuracy of the dosimetry was confirmed by comprehensive measurements and by frequent consistency checks performed over the course of the study. RESULTS: Data were collected on 2,142 instances of interventional radiology procedures, 48 comprehensive physics evaluations, and 581 periodic consistency checks from the 12 fluoroscopic units in the study. There were wide variations in dose and statistically significant differences in fluoroscopy time, number of images, DAP, and CD for different instances of the same procedure, depending on the nature of the lesion, its anatomic location, and the complexity of the procedure. For the 2,142 instances, observed CD and DAP correlate well overall (r = 0.83, P <.000001), but correlation in individual instances is poor. The same is true for the correlation between fluoroscopy time and CD (r = 0.79, P <.000001). The correlation between fluoroscopy time and DAP (r = 0.60, P <.000001) is not as good. In 6% of instances (128 of 2,142), which were principally embolization procedures, transjugular intrahepatic portosystemic shunt (TIPS) procedures, and renal/visceral artery stent placements, CD was greater than 5 Gy. CONCLUSIONS: Most procedures studied can result in clinically significant radiation dose to the patient, even when performed by trained operators with use of dose-reducing technology and modern fluoroscopic equipment. Embolization procedures, TIPS creation, and renal/visceral artery stent placement are associated with a substantial likelihood of clinically significant patient dose. At minimum, patient dose data should be recorded in the medical record for these three types of procedures. These data should include indicators of the risk of deterministic effects as well as the risk of stochastic effects.

Adolescent↗

MR-guided transjugular intrahepatic portosystemic shunt creation with use of a hybrid radiography/MR system.

PURPOSE: To evaluate the performance of a combined hybrid radiography/magnetic resonance (MR) unit to guide portal vein (PV) puncture during human transjugular intrahepatic portosystemic shunt (TIPS) creation. MATERIALS AND METHODS: Fourteen patients undergoing TIPS creation were studied during standard clinical applications. Patients were anesthetized and then positioned in an open MR unit containing a flat-panel radiographic fluoroscopic unit. With use of a combination of fluoroscopy and MR imaging, the PV was accessed and the TIPS procedure was performed. A noncovered nitinol stent or a covered stent-graft was placed in the TIPS tract. Number of punctures required, total procedure time, fluoroscopy time, procedural success rate, complications, and ultrasonographic and clinical follow-up were recorded. RESULTS: Clinical success was obtained in 13 of 14 patients. In one patient, extrahepatic puncture of the PV occurred, resulting in hemorrhage and requiring placement of a covered stent to control the bleeding. The mean number of punctures required to access the PV was 2.6 +/- 1.7, and the total procedure time was 2.5 hours +/- 0.6. Mean fluoroscopy time was 22.3 minutes +/- 5.5. Results of clinical and ultrasonographic follow-up compare favorably to previously published reports. CONCLUSION: TIPS creation with a combination hybrid radiography/MR unit is feasible and may reduce the number of needle passes required and radiation exposure, with similar overall outcomes compared with studies reported in the literature.

Alloys↗

Evaluation of MR/fluoroscopy-guided portosystemic shunt creation in a swine model.

PURPOSE: To evaluate three different percutaneous portosystemic shunts created with magnetic resonance (MR) imaging and fluoroscopy guidance in a swine model. MATERIALS AND METHODS: In stage 1 of the experiment, an active MR intravascular needle system was created for needle tracking and extracaval punctures. Twenty inferior vena cava (IVC)/superior mesenteric vein (SMV)/portal vein (PV) punctures were performed in 10 swine (weight, 40-45 kg) in a 1.5-T short-bore interventional MR imager. With use of a real-time MR imaging sequence, the needle was guided through the IVC and into the SMV or PV (N = 20 punctures). After confirmation, a wire was advanced into the portal venous system under MR imaging guidance (N = 20). In stage 2, animals were transferred to the radiographic fluoroscopy suite for deployment of shunts. Three different shunts were evaluated in this study: (i) a commercial stent-graft, (ii) a prototype bridging stent, and (iii) a prototype nitinol vascular anastomotic device. Postprocedural necropsy was performed in all animals. RESULTS: Successful MR-guided IVC/SMV punctures were performed in all 20 procedures (100%). All three shunts were deployed. Stent-grafts had the poorest mechanism for securing a shunt. The vascular anastomotic device and the bridging stent had more secure anchoring mechanisms but also had higher technical failure rates (50% and 40%, respectively). When deployed successfully, the vascular anastomotic device resulted in no bleeding at the sites of punctures at necropsy. CONCLUSION: Percutaneous shunts and vascular anastomoses between the portal mesenteric venous system and IVC were successfully created with use of a combination of MR imaging and conventional fluoroscopy for guidance.

Alloys↗

Does the pancreas move with respiration?

BACKGROUND AND AIM: The pancreas is a retroperitoneal organ and has been classically considered to be immobile on respiration. Recent radiological studies assessing the mobility of the pancreas have challenged this traditional concept. The present study was conducted to assess the movement of pancreas with respiration using fluoroscopy, a simple and inexpensive method. METHODS: Patients with chronic pancreatitis who had either pancreatic calcification evident on fluoroscopy or an indwelling pancreatic duct stent were studied. The movement of the pancreas was assessed under fluoroscopy by measuring the displacement of the stent or calcification in relationship to the spine in maximum inspiration followed by maximum expiration. RESULTS: Twenty-two patients (mean age 35.45 + or - 11.29 years, 17 men) with chronic pancreatitis were included in the study. Ten patients had pancreatic calcification and 12 had an indwelling pancreatic duct stent (two in the dorsal duct, 10 in the ventral duct). In all patients, the pancreas moved downward in the craniocaudal direction on deep inspiration. Pancreatic excursion from maximum inspiration to maximum expiration ranged from 0.1 to 3.4 cm. In addition, a medial movement of the head of pancreas was also noted in most of the patients. On univariate analysis, no association was found between the range of movement and the age or sex of the patient, duration or etiology of disease, presence or absence of calcification, severity of ductal changes of chronic pancreatitis and the length or diameter of the pancreatic stent placed. CONCLUSION: The pancreas moves craniocaudally with respiration and the head moves medially on inspiration.

Adult↗

Improved clinical efficacy of external cardioversion by fluoroscopic electrode positioning and comparison to internal cardioversion in patients with atrial fibrillation.

BACKGROUND: Despite using different electrode positions, "conventional" external DC cardioversion in patients with atrial fibrillation is ineffective in 6%-50% of cases. An alternative when DC cardioversion is not successful is low energy internal cardioversion, which is performed at increased risk. We tested the hypothesis that optimization of electrode pad position under fluoroscopy to encompass as much atrial muscle as possible might improve the success rate of external cardioversion and thus minimize the need for internal cardioversion. METHODS: Fifteen (9 males, 6 females) patients (age: 54 +/- 15 years, weight: 124 +/- 35 kg) with chronic atrial fibrillation (> 8 weeks) who had undergone unsuccessful conventional external cardioversion entered the study. Repeat conventional external cardioversion with electrodes in standard (right anterior and left posterior) positions was followed by "optimized" external cardioversion by positioning electrodes under fluoroscopy (using metallic markers). In case of failure, internal cardioversion was performed. RESULTS: All 15 patients had undergone unsuccessful conventional external cardioversion with 360-J shocks. Eight patients (group A) reverted to sinus rhythm with one or two 360-J shocks using fluoroscopy-guided pad placement (53%). Six of the remaining 7 (86%) patients (group B) had successful internal cardioversion with biphasic shocks (12 +/- 3 J). The body weight and body mass index were statistically lower in group A vs group B (106 +/- 27 vs 145 +/- 33 kg, p = 0.03 and 35 +/- 8 vs 45 +/- 8 kg/m2, P = 0.48, respectively). There was no statistically significant in age, height, body surface area, duration of atrial fibrillation, amiodarone therapy, ejection fraction, or underlying heart disease. CONCLUSION: Unsuccessful external DC cardioversion, in some patients, is in part due to suboptimal conventional positioning of electrode pads that can be improved under fluoroscopic guidance by achieving the best possible vector encompassing the right and left atria. The optimized external cardioversion technique may minimize the need for internal cardioversion, which remains an effective approach when external cardioversion fails.

Adolescent↗

Nonfluoroscopic catheter navigation for radiofrequency catheter ablation of supraventricular tachycardia in children.

BACKGROUND: Radiofrequency catheter ablation (RCA) of supraventricular tachycardia (SVT) in children is highly successful but requires exposure to radiation. Nonfluoroscopic mapping systems may significantly reduce fluoroscopy time. METHODS: Forty consecutive pediatric patients who underwent RCA for accessory pathways (AP) or AV nodal reentrant tachycardia (AVNRT) with use of a nonfluoroscopic navigation system (Ensite NavX) (group A) were compared retrospectively to 40 consecutive patients with similar diagnoses who underwent RCA with fluoroscopic guidance only (group B). RESULTS: Group A (mean age 12.1+/-2.9 years, mean weight 47+/-13.9 kg) consisted of 11 patients (27.7%) with AVNRT and 29 (72.5%) with AP. Group B (mean age 10.9+/-3.1 years, mean weight 47.1+/-17.1 kg) consisted of 7 patients (17.5%) with AVNRT and 33 (82.5%) with AP. There were no significant differences in AP location, patients with congenital heart disease, and number of radiofrequency lesions. Fluoroscopy time was significantly shorter in group A than in group B (10.4+/-6.1, range 3.1-28.8 minutes, vs 24.9+/-16.0, range 4.4-82.0 minutes, P<0.0001). Procedure duration was also significantly shorter in group A than in group B (170+/-68.5, range 90-420 minutes, vs 218+/-69.3, range 90-360 minutes, P<0.0001). Initial success was 95% in group A and 100% in group B. Tachycardia recurrences occurred in two patients in group A (5%) and six patients in group B (15%). Final success, including repeat ablations for recurrences or failures, was 100% in both groups. CONCLUSIONS: The use of a nonfluoroscopic system for catheter navigation significantly reduced fluoroscopy exposure and total procedure duration of RCA of common SVT substrates in children.

Body Surface Potential Mapping↗

Radiation dose at small intestinal biopsies in children: results of a national study.

The radiation dose delivered at small intestinal biopsies in children was investigated in a national study engaging 42 of 43 paediatric departments performing small intestinal biopsies. Measurements were performed with a thermoluminescence system at 257 biopsies. The results show a considerable variation of both duration of fluoroscopy (range 2-660 s; department medians) and radiation dose (range 0.1-14 mSv; department medians). The median of all absorbed doses was 0.69 mSv and the median duration of fluoroscopy 30 s. The observed variation cannot be explained by differences in X-ray equipment only. By optimization of all the technical conditions, such as X-ray equipment, biopsy device and method of sedation, at least a 6-fold reduction of radiation dose was obtained in one department. Especially if the operator is less experienced, it is worthwhile to optimize other factors to achieve the lowest possible radiation dose to the child. Children, coeliac disease, fluoroscopy, radiation dose, radiation risk, small intestinal biopsy.

Adolescent↗

Conceptus radiation dose assessment from fluoroscopically assisted surgical treatment of hip fractures.

Our aims in the present study were to (a) provide normalized dose data for the estimation of the conceptus dose from fluoroscopically assisted surgical treatment of hip fractures carried out during all trimesters of pregnancy and (b) estimate the conceptus radiation dose and risks associated with fluoroscopy during a typical treatment of hip fracture performed on a pregnant woman. Conceptus doses normalized to entrance surface dose (ESD) or dose area product (DAP) were obtained with the help of anthropomorphic phantoms simulating pregnancy in the three trimesters of gestation. ESD and conceptus dose measurements were carried out using thermoluminescent dosimeters. DAP to conceptus dose conversion factors were estimated for the first, second and third trimesters of gestation. Conceptus dose data normalized to ESD were also estimated to investigate whether these conversion factors may be used for procedures carried out in x-ray units not equipped with a DAP meter. Fluoroscopically assisted surgical treatments were performed in 18 women. The projections involved in these procedures are (a) posteroanterior (PA) and (b) lateral crosstable 45 degrees (LC). Radiation doses for a potential conceptus were estimated by using normalized dose data obtained in phantoms. The results consist of tabulated dose data normalized to DAP or ESD for the estimation of a conceptus dose. An important finding of this study was that the total DAP of a procedure, instead of the individual DAP values of each projection, could be used for the accurate estimation of the conceptus dose. Conceptus doses calculated using dose data normalized to ESD are about 23% higher compared to those estimated using data normalized to DAP. This discrepancy may be attributed to the contribution of scattering radiation from PA projection to ESD measurement of LC projection and vice versa. Therefore, dose data normalized to ESD do not provide accurate conceptus dose estimation. Doses normalized to DAP showed a dependence on (a) tube potential and (b) tube filtration. Data are provided to extent the doses normalized to DAP for the standard spectrum to other tube voltages and filtrations. The maximum dose for a potential conceptus was 0.425 mGy for a patient irradiated for 50 seconds during the PA projection and for 40 seconds during the LC projection. Although the total duration of fluoroscopy is usually less than 2 minutes during a typical procedure, screening time as long as 14 minutes has been reported in the literature for treatment of complex fractures. The relationship between conceptus dose and fluoroscopy time found in the current study showed that, in these cases, the radiation dose received by a conceptus may exceed 1 mGy. In conclusion, an accurate estimation of conceptus doses associated with fluoroscopically assisted surgical treatment of hip fractures can be made using the DAP normalized dose data provided in this study. Conceptus doses from a typical procedure is less than 1 mGy during all trimesters.

Dose-Response Relationship, Radiation↗

An analysis of dose efficiency in image intensified fluoroscopic examinations.

In this paper we have developed expressions for assessing radiographic systems where grids, air gaps, or both are used. The application of these expressions to film-screen detectors gives predictions in good agreement with data that are found in the literature. Using this analytical tool, image intensified fluoroscopy has been studied. We have shown that under certain circumstances with air gaps there are potential gains in the efficient use of dose in fluoroscopy. The air gaps are of particular value where relatively thin body parts or small lesions are being examined using small focal spot generators. An independent gain control on the image intensifier would be useful for achieving the greatest flexibility when using magnification in fluoroscopy.

Fluoroscopy↗

Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology.

Noise properties of active matrix, flat-panel imagers under conditions relevant to diagnostic radiology are investigated. These studies focus on imagers based upon arrays with pixels incorporating a discrete photodiode coupled to a thin-film transistor, both fabricated from hydrogenated amorphous silicon. These optically sensitive arrays are operated with an overlying x-ray converter to allow indirect detection of incident x rays. External electronics, including gate driver circuits and preamplification circuits, are also required to operate the arrays. A theoretical model describing the signal and noise transfer properties of the imagers under conditions relevant to diagnostic radiography, fluoroscopy, and mammography is developed. This frequency-dependent model is based upon a cascaded systems analysis wherein the imager is conceptually divided into a series of stages having intrinsic gain and spreading properties. Predictions from the model are compared with x-ray sensitivity and noise measurements obtained from individual pixels from an imager with a pixel format of 1536 x 1920 pixels at a pixel pitch of 127 microns. The model is shown to be in excellent agreement with measurements obtained with diagnostic x rays using various phosphor screens. The model is used to explore the potential performance of existing and hypothetical imagers for application in radiography, fluoroscopy, and mammography as a function of exposure, additive noise, and fill factor. These theoretical predictions suggest that imagers of this general design incorporating a CsI: Tl intensifying screen can be optimized to provide detective quantum efficiency (DQE) superior to existing screen-film and storage phosphor systems for general radiography and mammography. For fluoroscopy, the model predicts that with further optimization of a-Si:H imagers, DQE performance approaching that of the best x-ray image intensifier systems may be possible. The results of this analysis suggest strategies for future improvements of this imaging technology.

Electronics↗

Diagnosis of small bowel Crohn's disease: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysis.

BACKGROUND AND AIMS: The diagnostic yield of capsule endoscopy (CE) compared with magnetic resonance imaging (MRI) in small bowel Crohn's disease is not well established. We prospectively investigated CE, MRI, and double contrast fluoroscopy in patients with suspected small bowel Crohn's disease. METHODS: Fifty two consecutive patients (39 females, 13 males) were investigated by MRI, fluoroscopy and--if bowel obstruction could be excluded--by CE. In 25, Crohn's disease was newly suspected while the diagnosis of Crohn's disease (non-small bowel) had been previously established in 27. RESULTS: Small bowel Crohn's disease was diagnosed in 41 of 52 patients (79%). CE was not accomplished in 14 patients due to bowel strictures. Of the remaining 27 patients, CE, MRI, and fluoroscopy detected small bowel Crohn's disease in 25 (93%), 21 (78%), and 7 (of 21; 33%) cases, respectively. CE was the only diagnostic tool in four patients. CE was slightly more sensitive than MRI (12 v 10 of 13 in suspected Crohn's disease and 13 v 11 of 14 in established Crohn's disease). MRI detected inflammatory conglomerates and enteric fistulae in three and two cases, respectively. CONCLUSION: CE and MRI are complementary methods for diagnosing small bowel Crohn's disease. CE is capable of detecting limited mucosal lesions that may be missed by MRI, but awareness of bowel obstruction is mandatory. In contrast, MRI is helpful in identifying transmural Crohn's disease and extraluminal lesions, and may exclude strictures.

Acute Disease↗

Clinical application of region-of-interest techniques to radiologic imaging.

In region-of-interest (ROI) imaging, a filter with a central aperture is used to substantially reduce patient dose outside of an ROI while maintaining or improving image quality within the ROI. The benefits of ROI imaging can be realized by using standard imaging equipment. ROI imaging has been clinically applied to gastrointestinal radiology and interventional procedures. In gastrointestinal procedures, ROI fluoroscopy without image processing can be used without adversely affecting the procedure or interfering with spot radiography. ROI fluoroscopy can reduce the dose-area product by a factor of 1.7 for gastrointestinal procedures. In interventional neuroradiologic procedures, equalized display brightness is achieved with road mapping during fluoroscopy and with standard digital subtraction techniques during angiography. In interventional radiology, ROI filters can generally reduce the patient skin dose to levels below the threshold for skin effects, thus eliminating these effects across more than 85% of the field of view.

Central Nervous System↗

Patient exposure and associated radiation risks from fluoroscopically guided vertebroplasty or kyphoplasty.

PURPOSE: To derive normalized data for the estimation of effective, gonadal, and peak skin doses to patients undergoing vertebroplasty or kyphoplasty and to investigate the potential for cancer induction, genetic effects, and radiation-induced skin injury after such procedures. MATERIALS AND METHODS: Dose values normalized over dose-area product were determined for all radiosensitive organs and tissues by using a humanoid phantom and thermoluminescence dosimetry separately for anteroposterior and lateral projections. Measurements were obtained for treatments of the fifth, eighth, and 11th thoracic vertebrae and the first, third, and fifth lumbar vertebrae. Total fluoroscopy time and resultant dose-area product from each fluoroscopic exposure were monitored in 11 consecutive patients (seven women and four men) undergoing kyphoplasty. The age range of these patients was 41-78 years, and the mean age was 58 years. RESULTS: Mean total fluoroscopy time for kyphoplasty was 10.1 minutes +/- 2.2 (standard deviation). Mean effective dose to patients from kyphoplasty was 8.5-12.7 mSv, and mean gonadal dose was 0.04-16.4 mGy, depending on the level of the treated vertebra. Skin injuries after kyphoplasty are improbable if source-to-skin distance is 35 cm or more; however, such injuries may occur if the total fluoroscopy time per projection is extended and/or the source-to-skin distance is less than 35 cm during the procedure. CONCLUSION: Patient radiation exposure and associated risks from vertebroplasty or kyphoplasty may be considerable. Data obtained in the current study may be used to establish patient effective dose, gonadal dose, and entrance skin exposure, as well as associated risks, from these fluoroscopically guided surgical treatments of spinal disorders.

Adult↗

Diaphragmatic weakness after transcatheter arterial chemoembolization of inferior phrenic artery for treatment of hepatocellular carcinoma.

PURPOSE: To prospectively assess the diaphragmatic anatomic and functional consequences of transcatheter arterial chemoembolization (TACE) of the inferior phrenic artery in patients with hepatocellular carcinoma. MATERIALS AND METHODS: Informed consent and institutional review board approval were obtained. Fifteen patients (13 men, two women; mean age, 52 years; age range, 22-61 years) who underwent TACE of the inferior phrenic artery for treatment of hepatocellular carcinoma were enrolled. The right inferior phrenic artery was embolized in 14 patients, and the left inferior phrenic artery was embolized in one patient. Chest radiography, fluoroscopy, computed tomography (CT), and pulmonary function tests were performed before and after TACE of the inferior phrenic artery. The post-TACE examinations were performed 2-3 months after TACE, and the results were compared with those of the pre-TACE examinations. A paired t test or the Wilcoxon signed rank test was used for statistical analyses. RESULTS: At chest radiography and fluoroscopy, six of 15 patients (40%) had both elevation and movement abnormality of the ipsilateral hemidiaphragm after TACE of the inferior phrenic artery. The mean (+/- standard deviation) diaphragmatic thickness on CT scans changed from 9.11 mm +/- 3.02 to 7.67 mm +/- 2.27 after TACE (P = .048). The mean vital capacity also was significantly decreased after TACE, from 91.87% +/- 18.52 to 82.27% +/- 16.94 of the predicted value (P = .006). The decreases in diaphragmatic thickness and vital capacity were most pronounced in the patients with abnormal findings at chest radiography and fluoroscopy. CONCLUSION: After TACE of the inferior phrenic artery, a substantial portion of patients showed functional and anatomic evidence of diaphragmatic weakness.

Adult↗

Cervical spine evaluation in obtunded or comatose pediatric trauma patients: A pilot study.

A uniformly accepted protocol for evaluation and clearance of the cervical spine of pediatric trauma patients with altered mental status does not currently exist. We sought to detect cervical spine injuries in this group with minimal risk. Patients were evaluated with standard three-view cervical spine radiographs and CT when necessary. Those patients without radiographic abnormality and altered mental status underwent flexion-extension of the cervical spine using fluoroscopy with somatosensory evoked potential (SSEP) monitoring. Those with abnormal movement by fluoroscopy or changes in SSEP underwent MRI. Fifteen patients were evaluated with this protocol. Two patients had movement on flexion-extension of the cervical spine and 5 had SSEP changes. Three patients had an MRI with only 1 showing injury. Five patients had residual hemiparesis. Evaluation of the cervical spine in obtunded or comatose pediatric trauma patients can be done safely with flexion-extension under fluoroscopy and SSEP monitoring. Further prospective studies are required to determine the efficacy of SSEP monitoring for cervical spine clearance in this select population.

Adolescent↗

Radiation exposure to the child during cardiac catheterization.

Few data are available regarding radiation exposure to children during cardiac catheterization. Using lithium fluoride thermoluminescent dosimeters, radiation exposure was measured during precatheterization chest roentgenography, fluoroscopy (hemodynamic assessment phase of catheterization) and cineangiography in 30 infants and children, ages 3 days to 21 years. Dosimeters were placed over the eyes, thyroid, anterior chest, posterior chest, anterior abdomen, posterior abdomen and gonads. Average absorbed chest doses were 24.5 mR during chest roentgenography, 5810 mR during catheterization fluoroscopy and 1592 mR during cineangiography. During the complete catheterization, average doses were 26 mR to the eyes, 431 mR to the thyroid area, 150 mR to the abdomen and 11 mR to the gonads. Radiation exposure during pediatric cardiac catheterization is low to the eyes and gonads but high to the chest and thyroid area. To decrease radiation dosage we suggest (1) low pulse-rate fluoroscopy; (2) substitution of contrast echocardiography for cineangiography; (3) large-plate abdominal/gonadal shielding; (4) a selective shield for thyroid area; (5) a very small field during catheter manipulation. Minimum radiation consistent with accurate diagnosis is optimal; however, erroneous or incomplete diagnosis is more dangerous than radiation-related hazards.

Adolescent↗

A physical assessment of the imaging performance of panel-type X-ray image intensifier.

The performance of a commercial panel-type X-ray image intensifier has been investigated by physical methods, both objective and subjective. The objective measurements show that the manufacturer's claims are justified, except perhaps in regard to contrast loss. The subjective measurements reveal that the conversion factor ("gain") of the device is such that dark-adaptation is not necessary, though best results are obtained in a nearly dark room. Hence the device confers a significant advantage, both in information and in dose to the patient, over traditional fluoroscopy. However, the conversion factor is nearly three orders of magnitude smaller than that of a conventional X-ray image-intensifier television system. Therefore, at modern fluoroscopic exposure rates, the eye is operating at light levels at which its own deficiencies set a limit to the perceptible information. To equal the performance of modern fluoroscopy the exposure rate to the intensifier must be increased to about 20 times the value customary in modern fluoroscopy. This can be done only by increasing the X-ray factors (kV and mA), resulting in a corresponding increase in dose to the patient of about one order of magnitude. Such an increase is in many circumstance unacceptable.

Evaluation Studies as Topic↗