Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AGGLUTINATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75Linked to original sources

Commercial latex agglutination tests for detection of Haemophilus influenzae type b and Streptococcus pneumoniae antigens in patients with bacteremic pneumonia.

The validity of commercial latex agglutination kits for detection of Haemophilus influenzae type b and Streptococcus pneumoniae antigens in serum and urine specimens was studied. We tested serum and urine specimens from 44 patients with bacteremic pneumonia (23 S. pneumoniae, 13 H. influenzae type b, 11 other) with commercial latex agglutination kits (Directigen, Bactigen) for S. pneumoniae and H. influenzae type b antigens. All specimen samples were randomized and read blindly by two readers. Interreader reproducibility was 100%. The sensitivity and specificity of both kits for H. influenzae type b antigens in serum and urine were greater than 90%. None of the 24 urine samples from S. pneumoniae bacteremic patients were positive by either kit, although 6 ng of type 3 polysaccharide could be detected in spiked urine. Sensitivity for S. pneumoniae antigens in serum was 27% for Directigen and 38% for Bactigen. Specificity for S. pneumoniae antigens in serum was 95% for Directigen and 74% for Bactigen. The results suggest that the kits are useful in diagnosing H. influenzae type b pneumonia. However, the commercially available S. pneumoniae reagents tested appear to have limited utility for diagnosing S. pneumoniae pneumonia because both kits lack sensitivity and Bactigen lacks specificity, as well.

Acute Disease↗

Evaluation of the campyslide agglutination test for confirmatory identification of selected Campylobacter species.

The utility of a rapid latex slide agglutination test (Campyslide; BBL Microbiology Systems, Cockeysville, Md.) in detecting selected Campylobacter spp. was evaluated and compared with that of conventional identification methods. Isolated colonies suggestive of Campylobacter spp. were tested directly from primary selective media after incubation at 42 degrees C under microaerophilic conditions. Stock cultures of Campylobacter jejuni (n = 27) and C. coli (n = 3) were correctly confirmed to the genus level by latex agglutination when tested in pure cultures or isolated from seeded human feces. A total of 50 fresh clinical isolates of Campylobacter spp. (45 C. jejuni and 5 C. coli) were examined, with complete agreement observed between the latex test and conventional methods. Of 173 non-Campylobacter isolates tested from primary plates, only 1 rough strain of Pseudomonas aeruginosa produced a false-positive result. Although the manufacturer recommends a 30-min antigen extraction, 1 or 5 min was found to be sufficient. Also, confirmation could be achieved within 24 h of inoculation of clinical specimens, 2 days earlier than with conventional methods.

Campylobacter↗

Latex agglutination and enzyme-linked immunosorbent assays for cytomegalovirus serologic screening of transplant donors and recipients.

The effectiveness of three serologic assays (two enzyme-linked immunosorbent assays [ELISAs] and latex agglutination) for cytomegalovirus (CMV) serologic matching of donors and recipients was assessed over a 2-year period in a major organ transplant program. Sera with equivocal test results were investigated by repeat testing of serum samples and additional specimens from the individuals involved and monitoring of CMV infection in recipients. An in-house ELISA identified all CMV-infective donors as seropositive. Of 63 ELISA-positive donors, 5 were negative by latex agglutination; recipients from 3 of these donors developed primary CMV infection posttransplant. The in-house ELISA and a commercial ELISA (Abbott enzyme immunoassay; Abbott Laboratories, North Chicago, Ill.) had a 93% concordance of results; follow-up testing indicated that the Abbott assay was sensitive but had a false-positive rate of about 11%. One recipient with a false-positive result developed symptomatic primary CMV infection after receiving a seropositive organ. Thus, performance characteristics of currently used screening assays affect recipient outcome.

Antibodies, Viral↗

Avidin-biotin latex agglutination assay for detection of antibodies to viral antigens.

A new method for attaching antigens to latex by an avidin-biotin technique is described. The procedure permits control of the amount of antigen attached to the latex and eliminates the need for highly purified antigens and destructive bridging chemicals. The avidin-biotin latex agglutination assay is a simple, rapid test well suited to detection of viral antibody. The sensitivity and specificity, respectively, of the avidin-biotin latex agglutination assay compared with other assay results for antibody to viruses were as follows: cytomegalovirus, 98 and 100% (indirect hemagglutination assay); measles virus, 96 and 100% (enzyme-linked immunosorbent assay); and herpes simplex virus, 78 and 100% (indirect hemagglutination assay).

Animals↗

Problems with rapid agglutination methods for identification of Staphylococcus aureus when Staphylococcus saprophyticus is being tested.

Six rapid agglutination tests for identification of Staphylococcus aureus were evaluated by using 62 strains of S. aureus, 63 strains of S. saprophyticus, and 67 strains of other coagulase-negative staphylococci. S. saprophyticus was responsible for 19 of 26 false-positive results and 20 uninterpretable reactions. Thus, urinary staphylococcal isolates that are positive by rapid agglutination tests may require other confirmatory tests for the identification of possible S. saprophyticus.

Hemagglutination Tests↗

Evaluation of a reversed passive latex agglutination test for detection of Escherichia coli heat-labile toxin in culture supernatants.

One hundred strains of Escherichia coli were tested for the production of the heat-labile enterotoxin by the Y1 adrenal cell test and a commercially available reversed passive latex agglutination test. The strains were grown in Casamino Acids-yeast extract broth, and filtered culture supernatants were tested for the presence of heat-labile enterotoxin. There was perfect correlation between the Y1 test and the reversed passive latex agglutination test, and the latter was simple to perform and completed within 48 h.

Bacterial Toxins↗

Comparison of a latex agglutination assay and an enzyme-linked immunosorbent assay for detecting cholera toxin.

To determine the pandemic potential of Vibrio cholerae, one must demonstrate both the presence of O1 antigen and the production of enterotoxin (CT). Tissue culture or enzyme-linked immunosorbent assays (ELISAs) for CT have been limited to research and reference laboratories. A kit for detecting CT by reversed passive latex agglutination is now commercially available and was used to test 168 strains of V. cholerae O1 and non-O1. When compared with the routine ELISA, the latex test was 98% accurate (86 of 88) for serogroup O1 strains and 100% accurate (80 of 80) for non-O1 strains. For both O1 and non-O1 study strains, the sensitivity of the latex agglutination test was 0.97 and the specificity was 1.00 when results were compared with ELISA results. The latex test is commercially available and has the advantages of being less complicated and less time-consuming than the ELISA.

Cholera Toxin↗

Sandwich enzyme immunoassay and latex agglutination test for herpes simplex virus keratitis.

We determined the in vitro sensitivities and the diagnostic efficacies of a commercially available latex agglutination test and an enzyme-linked immunosorbent assay using a rabbit model of herpes simplex virus type 1 dendritic keratitis. In contrast to the latex agglutination test, the HERPCHEK enzyme-linked immunosorbent assay offers an extremely sensitive and reliable means of laboratory diagnosis of experimental herpes simplex virus keratitis and is more rapid than viral isolation in tissue culture.

Animals↗

Apparent false positive histoplasmin latex agglutination tests in patients with tuberculosis.

Serum specimens from patients admitted to a respiratory disease hospital were examined by the histoplasmin latex agglutination, the complement fixation, and the agar gel immunodiffusion tests. Of 300 sera examined, 21 (7.0%) gave an apparent false positive reaction at a dilution of 1:16 or greater. Fourteen (66%) of the 21 patients studied has culturally proven tuberculosis. One patient each had a diagnosis of hypertensive cardiovascular disease with congestive heart failure, infection with atypical mycobacteria (Runyon group III), chronic pneumonitis secondary to gunshot wound, and pulmonary abscess of unknown etiology; two had bronchogenic carcinoma; and one serum specimen came from an apparently healthy employee. The results of the histoplasmin latex agglutination test should be interpreted with caution, particularly if only one serological determination has been made and the titer is low.

Adult↗

Rapid detection of human group C rotaviruses by reverse passive hemagglutination and latex agglutination tests using monoclonal antibodies.

Reverse passive hemagglutination (RPHA) tests and a latex agglutination test with monoclonal antibodies (MAbs) were developed for the rapid detection of noncultivatable human group C rotaviruses. For RPHA tests, two MAbs, MAb 5A12 recognizing the outer capsid and MAb 13A3 recognizing the inner capsid, were separately used for the coating of sheep erythrocytes (SRBCs). Forty-six fecal samples were examined to confirm the practicality of the tests. As a result, there was concordance between the RPHA test with SRBCs coated with MAb 5A12 and polyacrylamide gel electrophoresis of viral RNA (RNA-PAGE) in 44 (95.6%) of 46 samples, while the diagnoses by the RPHA test with SRBCs coated with MAb 13A3 were in complete agreement with those by RNA-PAGE. Furthermore, a latex agglutination test with MAb 13A3 was also developed, and this test was fast enough and sensitive enough to successfully detect the viruses from most fecal samples within 2 min. The present procedures would be useful for the diagnosis of human group C rotavirus infections in clinical laboratories which are not well equipped.

Antibodies, Monoclonal↗

False-negative cerebrospinal fluid cryptococcal latex agglutination tests for patients with culture-positive cryptococcal meningitis.

Three cases of false-negative cerebrospinal fluid latex agglutination test results for patients with culture-positive cryptococcal meningitis are reported. False-negative results occurred in settings of low cryptococcal antigen concentrations in cerebrospinal fluid and were dependent on the latex agglutination test kit used. Investigation of each case revealed that prozone phenomena or interference from bound antibody or protein could not account for the false-negative results.

Adult↗

Evaluation of a modified nitrous acid extraction latex agglutination kit for grouping beta-hemolytic streptococci and enterococci.

The rapid and accurate identification of the Lancefield group of beta-hemolytic streptococci and enterococci is an important procedure in clinical laboratories. Latex agglutination techniques are more rapid and technically less demanding than traditional extraction-precipitation methods. Prolex (Pro-Lab Diagnostics, Richmond Hill, Ontario, Canada) is a latex agglutination kit which contains modified nitrous acid reagents to extract antigens and can be used to detect group D antigen in streptococci and enterococci, as well as group A, B, C, F, and G antigens. A total of 302 strains of streptococci and enterococci were tested with this kit. All streptococci of groups A (41 strains), B (39 strains), C (35 strains), D (3 strains), F (10 strains), and G (48 strains) were correctly grouped, as were 125 (97%) of 129 strains of enterococci. Prolex is a reliable method for grouping the beta-hemolytic streptococci and enterococci most frequently encountered in clinical laboratories.

Antigens, Bacterial↗

Reversed passive latex agglutination assay for detection of toxigenic Corynebacterium diphtheriae.

A reversed passive latex agglutination (RPLA) assay for determining the toxigenicity of Corynebacterium diphtheriae is presented. Rabbit antitoxin antiserum was raised by using commercially available diphtheria toxoid. This antiserum reacted with the diphtheria toxin when the culture supernatant was assayed by Western blotting, and it did not cross-react with other extracellular antigens. Affinity-purified antibodies for latex sensitization were obtained by using a Hi Trap N-hydroxysuccinimide-activated column. Demonstration of toxin in five of seven clinical isolates was in accordance with the PCR assay and the Vero cell cytotoxicity test. Culture of the bacteria for 6 h was sufficient for toxin production, and an additional 6 h was needed to observe latex agglutination. Therefore, diphtheria toxin can be detected in 12 h by this method. The lowest concentration of diphtheria toxin detectable by the RPLA assay was about 5 ng/ml. The RPLA assay can provide a convenient and reliable method for laboratories involved in the identification of toxinogenic corynebacteria.

Animals↗

Rapid identification of Burkholderia pseudomallei by latex agglutination based on an exopolysaccharide-specific monoclonal antibody.

We recently identified a constitutively expressed exopolysaccharide of Burkholderia pseudomallei which is composed of a unique linear tetrasaccharide repeating unit consisting of three galactose residues and one 3-deoxy-D-manno-2-octulosonic acid residue. In this study we developed a latex agglutination test based on monoclonal antibody 3015, which is specific for this exopolysaccharide, and evaluated this test for rapid identification of B. pseudomallei grown on agar plates. All 74 environmental and clinical B. pseudomallei strains tested, originating from different areas of Southeast Asia, northern Australia, and Africa, showed a strong and specific agglutination. B. pseudomallei-like organisms and a variety of other bacteria did not react. In conclusion this monoclonal antibody-based test is a simple, rapid, and highly specific method for identifying B. pseudomallei culture isolates from different geographic areas.

Antibodies, Bacterial↗

Evaluation of a microplate latex agglutination method (Verotox-F assay) for detecting and characterizing verotoxins (Shiga toxins) in Escherichia coli.

The performance of a commercial microplate latex agglutination assay, the Verotox-F assay, was compared with that of the Vero cell assay for the detection and characterization of Escherichia coli verocytotoxins (VTs). Culture filtrates of 68 VT-positive E. coli strains (65 human isolates [33 of serotype O157:H7/H-, 32 of non-O157 serotypes] and 3 reference strains) and 104 VT-negative strains (100 human isolates and 4 reference strains) were investigated. The toxin phenotypes and genotypes of the 68 VT-positive isolates were VT1 only (18 strains), VT2 and/or VT2c (33 strains), and VT1 plus VT2 (17 strains). The Verotox-F assay involved incubation of serial dilutions of culture filtrates with equal volumes of latex particles sensitized with anti-VT1 antibody or anti-VT2 antibody in 96-well microtiter plates with appropriate controls and examination for latex agglutination after 20 to 24 h. Compared to the results of the Vero cell assay, the Verotox-F assay was 100% sensitive and 100% specific for the detection of VTs in culture filtrates and correctly identified the toxin types of all 68 VT producers. By checkerboard titration with purified toxins, the sensitivity of the Verotox-F assay was found to be 14 pg (0.7 ng/ml) for VT1, 12 pg (0.6 ng/ml) for VT2, and 350 pg (17.5 ng/ml) for VT2c; this sensitivity is comparable to that of the bioassay. The anti-VT2 latex reagent detected both VT2 and VT2c and did not cross-react with VT1. The anti-VT1 reagent showed a low-level cross-reaction with VT2c only at levels (>/=4.5 microg/ml) that were about 1,000-fold higher than those found in culture filtrates. We conclude that the Verotox-F assay is highly sensitive and specific for the detection and characterization of VTs in culture filtrates of human E. coli isolates. The test is rapid, reliable, and easy to perform; its results are easy to interpret; and it should allow testing for VT to become more widely performed.

Animals↗

Detection of rabies virus antigen in dog saliva using a latex agglutination test.

Dog bites are responsible for more than 90% of human rabies deaths in Asia. We developed a simple and inexpensive test based on latex agglutination (LA) for rabies virus antigen detection in dog saliva. Rabies virus antigen could be detected by agglutination on a glass slide using latex particles coated with gamma globulin. By evaluation of paired saliva-brain specimens from 238 dogs, the LA test using saliva was 99% specific and 95% sensitive compared to the fluorescent antibody test (FAT) on brain smears. The advantages of the LA test over the standard FAT are that it is comparatively simple and there is no need to kill the animal before examination.

Animals↗

Comparison of the Vitek gram-positive susceptibility 106 card, the MRSA-Screen latex agglutination test, and mecA analysis for detecting oxacillin resistance in a geographically diverse collection of clinical isolates of coagulase-negative staphylococci.

The Vitek automated susceptibility testing system with a modified gram-positive susceptibility (GPS) 106 card (bioMerieux Vitek, Inc., Hazelwood. Mo.) and a rapid slide latex agglutination test (MRSA-Screen test; Denka Seiken Co., Ltd., Tokyo, Japan) were evaluated for their abilities to detect oxacillin resistance in coagulase-negative staphylococci (CoNS). The reference broth microdilution method and the detection of the mecA gene by PCR ("gold standard" reference result) were used to compare the results obtained with the commercial products. A total of 123 clinical isolates consisting of eight species were selected from U.S. surveillance collections. Among the mecA-positive isolates (95 strains), 30 isolates were initially negative on the MRSA-Screen test read at 3 min. When the agglutination reaction was extended for 10 min, 26 of the 30 isolates became positive. For a different four isolates, the oxacillin MIC was < or =0.25 microg/ml on the Vitek GPS 106 card. Among the mecA-negative isolates (28 strains), for two Staphylococcus warneri, two S. lugdunensis, and two S. saprophyticus strains MICs were > or =0.5 microg/ml by the reference broth microdilution method. Four of these isolates were also categorized as resistant with the Vitek GPS 106 card and two isolates were positive by the MRSA-Screen test. Overall, the MRSA-Screen test, GPS 106 card, and reference broth microdilution method had sensitivities of 95.7 (result at 10 min), 95.7, and 100%, respectively, and specificities of 92.8, 85.7, and 78.5%, respectively. Although the MRSA-Screen test required a slight procedural modification, both commercial methods achieved a sensitivity and specificity at detecting oxacillin resistance in CoNS at a level that was acceptable for clinical laboratory use.

Bacterial Proteins↗

Latex agglutination in the diagnosis of pneumococcal infection.

A latex agglutination (LA) method for detection of pneumococcal antigens was evaluated and compared with counterimmunoelectrophoresis (CIE). LA was 2 to 10 times more sensitive than CIE for the detection of purified capsular polysaccharides in defined media, but only when a 1+ or 2+ agglutination reaction was interpreted as positive. LA was much less sensitive than CIE with clinical samples. In 50 cases of pneumococcal pneumonia, antigen was detected in the serum almost twice as often with CIE (40%) as with LA (22%). LA was positive in six cases of pneumonia where CIE was negative; however, in three of these cases, antigen was detected only in undiluted sera, which raised some question about the specificity of the result. With 18 samples of cerebrospinal fluid (CSF) from 11 patients with pneumococcal meningitis, the CIE test was positive more frequenlty (14 samples) than was LA (11 samples). Moreover, antigen was detected in CSF by LA in only one additional patient than was positive by CIE alone. There was one false-positive LA reaction among 45 samples of CSF from patients without pneumococcal infection. Although LA is a less complicated method than CIE, it is not a sensitive test for pneumococcal antigens and would be of little value as a routine diagnostic method.

Antigens, Bacterial↗