Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “intercept”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

Transcutaneous bilirubinometry in preterm very low birthweight infants.

Transcutaneous bilirubinometry using the Minolta Airshield TcB was performed on 40 preterm VLBW Chinese infants during the first 7 days of life; altogether 614 observations were made on the forehead and sternum, respectively. A positive correlation between the TcB index and plasma bilirubin concentration was obtained on the forehead and sternum. Positive plasma bilirubin-TcB index correlations were also observed for each individual day. The plasma bilirubin-TcB index (forehead) regressions were fairly similar for the individual days and the combined overall regression except for 2 days (days 5 and 7). A slight improvement was observed when only bilirubin concentrations less than or equal to 200 mumol/l were evaluated. The intercepts were however different for individual days requiring correction factors to the combined overall regression intercept if the regression is to be used for the respective days. However, the plasma bilirubin-TcB index (sternum) regression for the individual days were significantly different one from another, and from the overall combined plasma bilirubin-TcB index (sternum) regression. This significant difference was still observed when only plasma bilirubin concentrations less than or equal to 200 mumol/l were evaluated. Hence, transcutaneous bilirubinometry has major limitations in preterm VLBW infants.

Bilirubin↗

Increased CO2 drive for ventilation in healthy human subjects may interfere with their ability to control lung volumes voluntarily.

Influence of increased CO2 drive for ventilation on the ability to judge lung volume was studied in seven healthy subjects. The psychophysical relationships between the objective and subjective magnitudes of lung volume were tested during air breathing and at two levels of hypercapnia (breathing 4% and 6% CO2 in oxygen). The relationships, described by linear regression, were analysed with respect to correlation coefficient, slope and intercept of the regression line. Slope and intercept seemed to decrease as the inspired CO2 mixture increased. Statistically significant difference was found only between air and inhalation of 6% CO2 in oxygen. Correlation coefficient remained unaffected by an increase in PCO2. These results indicate that an experimental increase in PCO2 caused by 6% CO2 inhalation alters the behavioural respiratory control in healthy human subjects.

Adult↗

Prostacyclin aerosol and inhaled nitric oxide fail to reverse pulmonary vasoconstriction induced by thromboxane analogue in dogs.

Inhalation of either prostacyclin (PGI2) as an aerosol or nitric oxide (NO) has been shown to elicit selective pulmonary vasodilation during hypoxic pulmonary vasoconstriction in dogs. Hypoxia may produce cardiovascular changes confounding interpretation of drug effects. Therefore, we investigated the effects of PGI2-aerosol and inhaled NO (50 p.p.m.) on pulmonary pressure-flow relationships (P/Q plots) during thromboxane analogue (U46619) induced pulmonary vasoconstriction. In eight anaesthetized dogs infusion of U46619 (0.33 +/- 0.18 micrograms kg-1 min-1) increased the slope (3.5 +/- 1.1 to 8.4 +/- 1.7 mmHg L-1 min-1, P < 0.001) and the intercept (4.4 +/- 2.3 to 10.2 +/- 4.6 mmHg, P < 0.01) of P/Q plots indicating pulmonary vasoconstriction. Inhalation of both aerosolized PGI2 solution (10 micrograms mL-1) and NO (50 p.p.m.) reduced neither the slope nor the intercept of the P/Q plots. Increasing the concentration of the aerosolized PGI2 solution to 50 micrograms mL-1 (n = 3) did not enhance the effect on pulmonary circulation but systemic vascular resistance fell by 23%. Oxygenation and intrapulmonary shunt remained unchanged during both PGI2-aerosol and inhaled NO. The failure of PGI2-aerosol to induce pulmonary vasodilation indicates that during aerosolization PGI2-concentrations at receptor sites on pulmonary vessels were insufficient to surmount U46619 induced vasoconstriction; this notion is supported by unchanged arterial plasma concentrations of the PGI2 degradation product 6-keto-PGF1 alpha. Considering that NO inhaled at comparable concentrations in sheep reversed U46619 induced pulmonary vasoconstriction, species differences may account for the failure of both PGI2-aerosol and NO to dilate pulmonary vessels in dogs.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗

Normal brain tissue response to photodynamic therapy using aluminum phthalocyanine tetrasulfonate in the rat.

The effects of photodynamic therapy (PDT) on normal brain tissue and depth of brain necrosis were evaluated in rats receiving 2.5 mg/kg aluminum phthalocyanine tetrasulfonate. Twenty-four hours later brains were irradiated with 675 nm light at a power density of 50 mW/cm2 and energy doses ranging from 1.6 to 121.5 J/cm2. Brains were removed 24 h after PDT and evaluated microscopically. When present, brain lesions consisted of well-demarcated areas of coagulation necrosis. When plotting the depth of necrosis against the natural log of energy dose, the data fit a piecewise linear model, with a changepoint at 54.6 J/cm2 and an x intercept of 7.85 J/cm2. The slopes before and after the changepoint were 2.04 and 0.21 mm/ln J cm-2, respectively. The x intercept suggests a minimum light dose below which necrosis of normal brain will not occur, whereas the changepoint indicates the energy density corresponding to an approximate maximum depth of necrosis.

Animals↗

High speed memory scanning in retarded and non-retarded adolescents.

Four groups of 13-14-year-olds, classified on the basis of Raven's Progressive Matrices scores as intellectually above average, average, below average and retarded, were subjects in a Sternberg (1966) type memory scanning task in which memory sets of two, three and four letters were used. Slope values of the memory search function did not differ between groups, whereas intercept values decreased with higher intelligence up to the average intelligence level. There was an overall inverse relation between intercept values and intelligence (r = -0.77) and similar relations obtained within the three non-retarded groups (rs greater than or equal to -0.57), but not within the retarded group (r = -0.06). Possible connections between these results and findings from inspection time studies are discussed.

Adolescent↗

Electrical resistances of cultured bovine arterial endothelium in solutions of various resistivities.

Relationships between the electrical resistance (Rm) of cultured endothelium and the resistivity (rho) of the bathing solution have been investigated, using eight monolayers of bovine arterial endothelium. Bathing solutions of differing rho were prepared by mixing culture medium and isosmolar (290 mM) sucrose in various proportions. Relationships between 1/Rm and 1/rho were linear, as predicted, with a mean 1/Rm intercept of zero. The slopes of the relationships give a mean fractional area per unit path length (Ap/delta chi) of 12.7 cm-1 for the paracellular pathways of the cultured endothelium. This resembles previous estimates of Ap/delta chi for mammalian endothelium in arteries. The 1/Rm intercept of zero indicates that the major electrical conducting pathways of cultured arterial endothelium are paracellular.

Animals↗

Detrimental effects after dobutamine infusion on rat left ventricular function: mechanical work and energetics.

We have previously reported that continuous infusion of dobutamine into the coronary artery induces positive inotropic effects but induces no detrimental effects in cross-circulated, excised normal rat hearts and even in Ca2+ overload-induced contractile failing rat hearts. However, we hypothesized that some detrimental effects on left ventricular (LV) function are induced after continuous dobutamine infusion and the following clearance of blood dobutamine, as is the case after beta-adrenergic receptor stimulation. To test this hypothesis, we investigated LV mechanical work and energetics in the same type of preparations that underwent continuous dobutamine infusion and clearance of blood dobutamine. We found that both mean end-systolic pressure and systolic pressure-volume area (PVA; a measure of total mechanical energy per beat) at midrange LV volume were significantly (P < 0.01) decreased. The mean myocardial oxygen consumption per beat intercept, which is composed of for the total Ca2+ handling in excitation-contraction coupling and basal metabolism, of the and PVA linear relation was also significantly (P < 0.05) decreased (n=8). The mean slope of the linear relation was unchanged in such hearts. Post-dobutamine basal metabolism was unchanged (n = 5 of the 8 hearts). The moderate proteolysis of a cytoskeleton protein, alpha-fodrin was identified (n = 7 of the 8 hearts with the decreased intercept), after clearance of blood dobutamine. In agreement with our hypothesis, the detrimental effect of the post-beta-adrenergic receptor stimulation was induced by a moderate concentration of dobutamine; we found systolic dysfunction due to the impairment of Ca2+ handling in excitation-contraction coupling in the rat LV and proteolysis of a cytoskeleton protein, alpha-fodrin.

Adrenergic beta-Agonists↗

The variation in shortening heat with sarcomere length in frog muscle.

Pairs of frog semitendinosus muscles were stimulated tetanically for 2 s at 0 degree C and, after 0.75 s of isometric contraction, were released at constant velocity for 0.16 s. The distance shortened was 0.3 micron per sarcomere. The extra heat (shortening heat) associated with the release was determined by comparison with isometric control tetani. The mean sarcomere length at the start of stimulation was varied between 2.25 and 3.75 microns. At the greater initial lengths there was considerable resting tension and heat was absorbed during releases of unstimulated muscles. This thermoelastic effect was also present during stimulation, so shortening heat values were calculated from the difference between the heat production of the stimulated and unstimulated muscle for releases over the same length range and at the same velocity. Laser diffraction was used to measure mean sarcomere length in the part of the muscle from which heat was recorded. At the greater initial lengths these central sarcomeres slowly elongated by a small amount during nominally isometric tetani. When a release was given during a tetanus the central sarcomere shortening was slightly less than that in a release of the unstimulated muscle with the same change of muscle length. In the period of a tetanus after the release had ended the rate of central sarcomere elongation was greater than that in an isometric tetanus. Shortening heat production had a large early component, during and just after the release, then continued to increase slowly up to the end of the tetanus. It is likely that sarcomere length redistribution along the muscle is responsible for the apparent slow phase, but has little effect on the early component. Shortening heat (determined as the early component) decreased linearly with increasing muscle length in the range studied. The intercept on the length axis was 3.78 +/- 0.08 micron per sarcomere (mean +/- S.E. of mean, n = 7, based on sarcomere length before stimulation). The corresponding intercept for the isometric tension before the release was 3.78 +/- 0.03 micron per sarcomere. The isometric heat rate at this time also decreased with increasing muscle length, but at 3.75 microns per sarcomere was still 50.0 +/- 2.0% of its maximum value. The results suggest that shortening heat, like isometric tension, is produced by the interaction of thick and thin filaments in contracting muscle.

Animals↗

The maximum speed of shortening in living and skinned frog muscle fibres.

This study was performed to determine whether Viso (the maximum speed of shortening extrapolated from force-velocity curves) equalled Vu (the unloaded speed of shortening determined by the slack test) in both living fibres from Rana temporaria and mechanically skinned fibres from Rana pipiens. In living fibres (R. temporaria) we obtained improved estimates of Viso by performing force clamps (isotonic) and length ramps (isovelocity) down to very low loads (0.005 isometric tension, P0). Force-velocity characteristics determined by force clamps and length ramps were the same. The hyperbolic Hill curves deviated from the force-velocity data at both high and low loads and underestimated Viso by varying degrees. A better estimate of Viso was obtained by linear extrapolation of data at loads from 0.005-0.02 P0 and the mean Viso at 7.5 degrees C was 4.08 muscle lengths/s +/- 0.11 (mean +/- S.E., n = 14). Improved estimates of Vu in living fibres were obtained by photographically calibrating the slack test. The mean Vu was 4.05 muscle lengths/s +/- 0.13 (mean +/- S.E., n = 14) and the intercept was 0.0156 fibre lengths (L0) +/- 0.0013 (mean +/- S.E., n = 14). The step-ramp photographic method, in which the motor speed is matched to Vu, was developed as an independent way to measure Vu in living fibres. Vu measured in this way agreed well with Vu measured by the slack test. In all living fibres, the improved estimates of Vu agreed well with the improved estimates of Viso. Vu/Viso = 0.99 +/- 0.01 (mean +/- S.E., n = 14). In mechanically skinned R. pipiens fibres, force clamps were performed down to loads of 0.01 mN. The force-velocity curve of the skinned fibres differed in shape from that of the living fibres. Although there was significant deviation from the Hill equation at low loads, the data at high loads were well fitted by the Hill curve. Viso determined by extrapolating the Hill equation to zero load was 5.87 muscle lengths/s +/- 0.38 (mean +/- S.E., n = 9) at 7.5 degrees C. In five fibres, the linear extrapolation of low loads (0.01-0.05 P0) showed that the Hill equation underestimated the true Viso by 6%. The slack test with mechanically skinned fibres was calibrated by taking a series of photographic exposures of the fibre at various times following each length step. Vu = 6.12 muscle lengths/s +/- 0.44 (mean +/- S.E., n = 10) and the intercept was 0.0585 L0 +/- 0.0069 (mean +/- S.E., n = 10).(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Correlations between myosin heavy chain isoforms and mechanical parameters in rat myometrium.

1. The relations between mechanical parameters and myosin heavy chain isoforms were studied in myometrial smooth muscle from ovariectomized rats (O) and oestrogen-treated, ovariectomized rats (E). 2. Treatment of the rats for three days with beta-oestradiol (2 micrograms kg-1 day-1) 2-4 weeks postsurgery, produced maximal changes in uterine mass and myosin content of approximately threefold. 3. Myosin heavy chain isoform SM1 (204 kDa) was increased from 65.5 +/- 0.8% to 72.9 +/- 0.6% of the total isoform species (P < 0.001, n = 24, O and E respectively) after oestrogen treatment. 4. To avoid complications associated with activation processes, mechanical parameters were measured in permeabilized myometrial fibre bundles activated at a calcium concentration of 12.6 microM. After oestrogen treatment the maximum velocity of shortening (Vmax) measured by the slack test increased from 0.044 +/- 0.006 of the reference length (Lo) s-1 to 0.101 +/- 0.006 Lo s-1, and maximal isometric force (Pmax) increased from 23.3 +/- 4.4 mN mm-2 to 74.1 +/- 13.9 mN mm-2 (P < 0.001, n = 24, respectively). Series elasticity and the half-time to peak force were not significantly altered. 5. Both Vmax and Pmax correlated significantly with percentage SM1 in O and E fibre bundles (r = 0.61 and 0.56, n = 48 fibres; or r = 0.87 and 0.89, n = 8 grouped data per rat). Vmax, however, was only weakly correlated with Pmax (r = 0.39, n = 48). 6. To assess the relative significance of the correlation between Vmax and the percentage of SM1 and that between Vmax and Pmax, we used a multiple regression analysis with the model Vmax = intercept + beta 1 x % SM1 + beta 2 x Pmax, where intercept, beta 1 and beta 2 are regression parameters. This analysis (n = 48) indicated that Vmax was significantly dependent on the percentage of SM1 (P < 0.0002) but not on Pmax (P < 0.61). 7. There were no significant differences in the levels of myosin light chain phosphorylation between O and E fibre bundles, indicating that light chain phosphorylation is unlikely to be the basis for the differences in mechanical parameters demonstrated by these fibres.

Animals↗

The effect of hypertonicity on force generation in tetanized single fibres from frog skeletal muscle.

1. We compared the tension transient that follows a step change in sarcomere length in normal Ringer solution with that in Ringer solution made hypertonic by the addition of 98 mM sucrose. Steps were applied on tetanized single muscle fibres during either the isometric plateau or the steady force response to lengthening at low speed. Sarcomere length was controlled on selected fibre segments by a striation follower. Analysis is limited to phase 1 (the tension change simultaneous with the length step, mainly due to cross-bridge elasticity) and phase 2 (the quick phase of tension recovery, a manifestation of the cross-bridge elementary force-generating process). 2. At the isometric tetanus plateau the steady force is reduced by 19% in hypertonic solution, and the stiffness is slightly increased. During slow lengthening both steady force and stiffness are similar in normal solution and in hypertonic solution. In hypertonic solution the tension-to-stiffness ratio, a measure of the mean cross-bridge extension before the step, is markedly reduced in isometric conditions (-23%), but not during lengthening (-2%). 3. The plots of instantaneous tension versus the length change during the step show that in hypertonic medium the elasticity of the fibre is almost undamped. Thus the increase in stiffness cannot be attributed to an increase in viscosity. 4. In isometric conditions (T2-T1)/(Ti-T1), the proportion of the initial tension drop recovered at the end of phase 2, is not affected by hypertonicity for releases of moderate and large size (> 2 nm) and is reduced for small releases (< 2 nm) and for stretches. The abscissa intercept of the relation (T2-T1)/(Ti-T1) versus step amplitude is the same in both media. During lengthening, for releases of small and moderate size, (T2-T1)/(Ti-T1) is 20% lower in hypertonic solution. For large releases the slope of the relation is lower so that the abscissa intercept is not changed. 5. The speed of quick tension recovery following a step length change imposed in isometric conditions is slightly depressed in hypertonic solution. The relation between speed of recovery and step amplitude maintains its shape and is shifted downwards. During lengthening, the speed of quick tension recovery in hypertonic solution is less dependent on step amplitude than in normal solution, as if a more linear viscoelasticity is responsible for a large fraction of residual recovery.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Carbonic anhydrase and control of breathing: different effects of benzolamide and methazolamide in the anaesthetized cat.

1. The effect of inhibition of erythrocyte carbonic anhydrase on the ventilatory response to CO2 was studied by administering benzolamide (70 mg kg-1, i.v.), an inhibitor which does not cross the blood-brain barrier, to carotid body denervated cats which were anaesthetized with chloralose-urethane. 2. In the same animals the effect on the ventilatory response to CO2 of subsequent inhibition of central nervous system (CNS) carbonic anhydrase was studied by infusing methazolamide (20 mg kg-1), an inhibitor which rapidly penetrates into brain tissue. 3. The results show that inhibition of erythrocyte carbonic anhydrase by benzolamide leads to a decrease in the slope of the normoxic CO2 response curve, and a decrease of the extrapolated arterial PCO2 at zero ventilation. 4. Inhibition of CNS carbonic anhydrase by methazolamide results in an increase in slope and alpha-intercept of the ventilatory CO2 response curve. 5. Using a mass balance equation for CO2 of a brain compartment, it is argued that inhibition of erythrocyte carbonic anhydrase results in a decrease in slope of the in vivo CO2 dissociation curve, which can explain the effects of benzolamide. 6. The changes in slope and intercept induced by methazolamide are discussed in relation to effects on neurones containing carbonic anhydrase, which may include central chemoreceptors.

Acidosis↗

The effect of low-dose acetazolamide on the ventilatory CO2 response curve in the anaesthetized cat.

1. The effect of 4 mg kg-1 acetazolamide (I.V.) on the slope (S) and intercept on the Pa,CO2 axis (B) of the ventilatory CO2 response curve of anaesthetized cats with intact or denervated carotid bodies was studied using the technique of dynamic end-tidal forcing. 2. This dose did not induce an arterial-to-end-tidal PCO2 (P(a-ET),CO2) gradient, indicating that erythrocytic carbonic anhydrase was not completely inhibited. Within the first 2 h after administration, this small dose caused only a slight decrease in mean standard bicarbonate of 1.8 and 1.7 mmol l-1 in intact (n = 7) and denervated animals (n = 7), respectively. Doses of acetazolamide larger than 4 mg kg-1 (up to 32 mg kg-1) caused a significant increase in the P(a-ET),CO2 gradient. 3. In carotid body-denervated cats, 4 mg kg-1 acetazolamide caused a decrease in the CO2 sensitivity of the central chemoreflex loop (Sc) from 1.52 +/- 0.42 to 0.96 +/- 0.32 l min-1 kPa-1 (mean +/- S.D.) while the intercept on the Pa,CO2 axis (B) decreased from 4.5 +/- 0.5 to 4.2 +/- 0.7 kPa. 4. In carotid body-intact animals, 4 mg kg-1 acetazolamide caused a decrease in the CO2 sensitivity of the peripheral chemoreflex loop (Sp) from 0.28 +/- 0.18 to 0.19 +/- 0.12 l min-1 kPa-1. Se and B decreased from 1.52 +/- 0.55 to 0.84 +/- 0.21 l min-1 kPa-1, and from 4.0 +/- 0.5 to 3.0 +/- 0.6 kPa, respectively, not significantly different from the changes encountered in the denervated animals. 5. It is argued that the effect of acetazolamide on the CO2 sensitivity of the peripheral chemoreflex loop in intact cats may be caused by a direct effect on the carotid bodies. Both in intact and in denervated animals the effects of the drug on Sc and B may not be due to a direct action on the central nervous system, but rather to an effect on cerebral vessels resulting in an altered relationship between brain blood flow and brain tissue PCO2.

Acetazolamide↗

Impaired sympathetic vascular regulation in humans after acute dynamic exercise.

1. The reduction in vascular resistance which accompanies acute dynamic exercise does not subside immediately during recovery, resulting in a post-exercise hypotension. This sustained vasodilatation suggests that sympathetic vascular regulation is altered after exercise. 2. Therefore, we assessed the baroreflex control of sympathetic outflow in response to arterial pressure changes, and transduction of sympathetic activity into vascular resistance during a sympatho-excitatory stimulus (isometric handgrip exercise) after either exercise (60 min cycling at 60% peak aerobic power (VO2,peak)) or sham treatment (60 min seated rest) in nine healthy subjects. 3. Both muscle sympathetic nerve activity and calf vascular resistance were reduced after exercise (-29.7 +/- 8.8 and -25.3 +/- 9.1%, both P < 0.05). The baroreflex relation between diastolic pressure and sympathetic outflow was shifted downward after exercise (post-exercise intercept, 218 +/- 38 total integrated activity (heartbeat)-1; post-sham intercept, 318 +/- 51 total integrated activity (heartbeat)-1, P < 0.05), indicating less sympathetic outflow across all diastolic pressures. Further, the relation between sympathetic activity and vascular resistance was attenuated after exercise (post-exercise slope, 0.0031 +/- 0.0007 units (total integrated activity)-1 min; post-sham slope, 0.0100 +/- 0.0033 units (total integrated activity)-1 min, P < 0.05), indicating less vasoconstriction with any increase in sympathetic activity. 4. Thus, both baroreflex control of sympathetic outflow and the transduction of sympathetic activity into vascular resistance are altered after dynamic exercise. We conclude that the vasodilation which underlies post-exercise hypotension results from both neural and vascular phenomena.

Adult↗

A global relationship between trabecular bone morphology and homogenized elastic properties.

An alternative concept of the relationship between morphological and elastic properties of trabecular bone is presented and applied to human tissue from several anatomical locations using a digital approach. The three-dimensional morphology of trabecular bone was assessed with a microcomputed tomography system and the method of directed secants as well as the star volume procedure were used to compute mean intercept length (MIL) and average bone length (ABL) of 4 mm cubic specimens. Assuming isotropic elastic properties for the trabecular tissue, the general elastic tensors of the bone specimens were determined using the homogenization method and the closest orthotropic tensors were calculated with an optimization algorithm. The assumption of orthotropy for trabecular bone was found to improve with specimen size and hold within 6.1 percent for a 4 mm cube size. A strong global relationship (r2 = 0.95) was obtained between fabric and the orthotropic elastic tensor with a minimal set of five constants. Mean intercept length and average bone length provided an equivalent power of prediction. These results support the hypothesis that the elastic properties of human trabecular bone from an arbitrary anatomical location can be estimated from an approximation of the anisotropic morphology and a prior knowledge of tissue properties.

Adult↗

Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.

Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, developed for quantifying the motion artifact reduction, were scanned while being moved using a computer-controlled linear stage. The resulting artifacts appeared between the high and low density regions as an apparent feature with a Hounsfield value that was the average of the two regions. A CT profile through these regions was fit using two error functions, each modeling the partial-volume averaging characteristics for the unmoving phantom. The motion artifact was quantified by determining the apparent distance between the two functions. The blurring artifact had a linear relationship with both the speed and the tangent of the wedge angles. When gating was employed, the blurring artifact was reduced systematically at the air-phantom interface. The gated image of phantoms moving at 20 mm/s showed similar blurring artifacts as the nongated image of phantoms moving at 10 mm/s. Nine patients were also scanned using the synchronized respiratory motion technique. Image artifacts were evaluated in the diaphragm, where high contrast interfaces intercepted the imaging plane. For patients, this respiratory gating technique reduced the blurring artifacts by 9%-41% at the lung-diaphragm interface.

Air↗

A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms.

The existing commercial software often inadequately determines respiratory peaks for patients in respiration correlated computed tomography. A semi-automatic method was developed for peak and valley detection in free-breathing respiratory waveforms. First the waveform is separated into breath cycles by identifying intercepts of a moving average curve with the inspiration and expiration branches of the waveform. Peaks and valleys were then defined, respectively, as the maximum and minimum between pairs of alternating inspiration and expiration intercepts. Finally, automatic corrections and manual user interventions were employed. On average for each of the 20 patients, 99% of 307 peaks and valleys were automatically detected in 2.8 s. This method was robust for bellows waveforms with large variations.

Algorithms↗

Morphometric texture analysis of spinal trabecular bone structure assessed using orthogonal radiographic projections.

The measurement of bone microstructure as well as bone mineral density may improve the estimation of bone strength. Cubic specimens (N = 26, 12 mm X 12 mm X 12 mm) of human cadaver vertebrae were cut along three orthogonal anatomic orientations, i.e., superior-inferior (SI), medial-lateral (ML), and anterior-posterior (AP). Contact radiographs of the bone cubes along all three orientations were obtained and then digitized by a laser scanner with pixel size of 50 microns x 50 microns. The specimens were tested in compression along the 3 orthogonal orientations and the Young's modulus (YM) was calculated for each direction. Quantitative computed tomography (QCT) was used to obtain a measure of trabecular bone mineral density (BMD). Global gray level thresholding and local thresholding algorithms were used to extract the trabecular bone network. Apparent trabecular bone fraction (ABV/TV), mean intercept length (I.TH), mean intercept separation (I.SP), and number of nodes (N.ND) were measured from the extracted trabecular network. Fractal dimension (Fr.D) of the trabecular bone texture was also measured. Paired t-tests showed that the mean values of each texture parameter (except ABV/TV) and of YM along the SI direction were significantly different (p < 0.05) from those along the ML and AP direction. However, the mean values along the ML and AP directions were not significantly different. Multivariate regression of YM as a function of the texture parameters and BMD showed that without adjusting for the effect of BMD, YM was significantly explained by all the texture parameters (R2 = 0.2-0.6). When BMD was included in the regression, although the variations in YM of ML, AP, and SI orientations could be explained by BMD alone, some of the texture parameters did improve the overall prediction of the biomechanical properties, while, some parameters such as ABV/TV and Fr.D in the ML orientation showed a more significant overall effect in explaining mechanical strength than did BMD. In conclusion, trabecular texture parameters correlated significantly with BMD and YM. Trabecular texture parameters from projectional radiographs reflect the anisotropy of trabecular structure. Quantitative radiographic assessment of trabecular structure using fine-detail radiography can potentially improve the estimation of bone strength.

Adult↗