Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pliability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

Heat-cured acrylic resin repaired with microwave-cured one: bond strength and surface texture.

This study evaluated the influence of chemical surface treatments in the repair strength of a heat-cured acrylic resin (Lucitone 550, (LU)). A total of 70 specimens were made with LU according to American Dental Association (ADA) specification No. 12. Of these, 14 remained intact and were used as a control group (GI). A total of 56 specimens were selected randomly. These specimens were cut in the middle (10 mm), repaired with a microwave acrylic resin (Acron MC (AC)), and processed in a microwave oven for 3 min at 500 W. Prior to the repair, the surface of the cut ends received different chemical treatments (GIII = AC monomer dipping/30 s; GIV = acetone dipping/30 s; GV = acetone dipping/15 s + blast of air + AC monomer dipping/15 s; GVI = no wetting treatment). However, 14 intact specimens made with AC formed a second control group (GII). The effect of the chemical treatments on the surface texture of LU was observed with scanning electron microscopy. Flexural test results were submitted to paired t-test and showed statistical differences (P < 0.05) only between the pairs GIV-GV and GIV-GVI. Strength mean values of repaired specimens were statistically lower (79-90%) than GII mean values. Strength mean values of GVI and GIV were 93 and 106%, respectively, of GI mean, showing no statistical differences. Scanning electron microscopic observations revealed various effects of the chemical treatments on the denture base resin surface. In conclusion, the wetting surface treatments affected the bond strength between the two acrylic resins, and no statistical differences in strength were observed between intact heat-cured denture base material and the same material repaired with microwave acrylic resin.

Acetone↗

Finite element analysis on preferable I-bar clasp shape.

An I-bar clasp is one of the most popular direct retainers for distal-extension removable partial dentures. However, no adequate information is available on preferable shape as determined by biomechanics. This study aimed (1) to investigate, by finite element analysis (FEA), the dimensions and stress of I-bar clasps having the same stiffness, and (2) to estimate a mechanically preferable clasp design. Three-dimensional FEA models of I-bar clasps were created with vertical and horizontal straight sections connected by a curved section characterized by six parameters: thickness of the clasp tip, width of the clasp tip, radius of the curvature, horizontal distance between the base and the vertical axis, vertical dimension between the tip and the horizontal axis, and taper (change of width per unit length along the axis). Stress was calculated with a concentrated load of 5 N applied 2 mm from the tip of the clasp in the buccal direction. A thinner and wider clasp having an taper of 0.020-0.023 and radius of curvature of 2.75-3.00 showed less stress. The results suggest that such a shape might be the preferable I-bar clasp shape as biomechanical viewpoint.

Algorithms↗

Influence of thermal cycles in water on flexural strength of laboratory-processed composite resin.

Recently a new generation of laboratory-processed composite resins containing submicron glass fillers was introduced, with claims of high strength. The purpose of this study was to evaluate the effect of thermal cycling in water on the flexural strength and hardness of several laboratory composite systems. The flexural strength of the new laboratory processed composite resins (Artglass [AG], Targis [TR] and Estenia [ES]) was significantly higher than that of conventional resins (Dentacolor [DC] and Cesead II [CS]). Thermocycling caused a reduction of the flexural strength but not a reduction of the hardness for most of materials tested. It was concluded that thermocycling affected the properties of the laboratory-processed hybrid type composite resin, ES, AG and TR. However, the changes of these properties were smaller than those of microfine type composite resin DC. Thus, ES, AG and TR may maintain better properties during service compared with DC.

Analysis of Variance↗

Denture base polymer Alldent Sinomer: mechanical properties, water sorption and release of residual compounds.

The aim of this study was to determine flexural properties, water sorption, solubility and release of residual compounds of a new paste type denture base polymer Alldent Sinomer. In addition, an effort was made to reinforce the denture base polymer with a polymer-pre-impregnated glass fibre reinforcement (Stick). Six rhombic test specimens were fabricated for the flexural test in accordance to the ISO 1567 standard. Water sorption and solubility was also determined as described in the ISO standard. Residual compound release into water was determined with the high performance liquid chromatography (HPLC) METHOD: The flexural strength of Sinomer polymer was 85.8 MPa and flexural modulus 2.73 GPa. Storing of test specimens in water reduced the flexural strength and the modulus. By adding the glass fibre reinforcement into the test specimen, the flexural strength and the modulus increased considerably (ANOVA, P < 0.001). The increase was minor with the reinforcement of low fibre content and high with the reinforcement of higher fibre content. Water sorption of the Sinomer polymer was 26.4 microgram mm-3 and solubility was 1.52 microgram mm-3. High performance liquid chromatography analysis revealed the release of 0.18 wt% fraction of compound which was determined as methylmethacrylate (MMA) monomer. The results of this study suggest that the new denture base polymer Sinomer passed the requirements of the ISO standards and that its mechanical properties can be increased considerably by an incorporation of a glass fibre reinforcement. The release of MMA monomer into water from the polymer should be taken into account when the polymer is used in denture bases of patients with an allergy towards MMA.

Absorption↗

Flexural behaviour of post-cured composites at oral-simulating temperatures.

Post-curing treatments have been known to improve the mechanical stability of visible light-cured composites. After individual post-curing treatment, the flexural strength (FS) of four commercial direct/indirect placement composite materials which differ greatly in composition [oligocarbonate dimethacrylate (OCDMA)-based Conquest C & B (CQT), Bisphenol-A glycidyl dimethacrylate (BisGMA)-based Charisma, urethane dimethacrylate (UDMA)-based Concept (CCT), and BisGMA/UDMA-based Dentacolor] was evaluated under water in the temperature range of 12-50 degrees C. A control series was tested in air at room temperature (25 +/- 1 degrees C). Data were analysed using ANOVA and Duncan's test. Flexural strengths overall decreased (20-40%, P < 0.01) with increasing temperatures except with Conquest C & B. Surprisingly, higher FS values were found in wet conditions than in dry conditions at 25 degrees C. UDMA-based materials much more easily undergo softening in water and by temperature change than do BisGMA- or OCDMA-based materials. Post-cured composites can be significantly affected by exposure to oral environments. Different composition determines the degree of influence.

Composite Resins↗

Adaptation of acrylic dentures reinforced with metal wire.

The aim of this study was to reveal the effect of metal wire on the adaptation of the denture reinforced with it. Forty maxillary dentures were made with two polymerization systems (DS system and SR-Ivocap system). The dentures were divided into two groups: (1) the unreinforced dentures (control) and (2) the dentures reinforced with metal wire 1.0 mm in diameter. Discrepancies between the denture base and the stone cast were measured at five points immediately after polymerization and after a 30-day immersion in water. The data were analysed using a two-way or one-way ANOVA test. Dentures reinforced with metal wire exhibited significantly lower adaptation to the stone cast than the unreinforced ones for each polymerization system. Immersion in water did not affect the adaptation of dentures reinforced with metal wire for each polymerization. Unreinforced dentures made by the DS system had significantly smaller discrepancies compared with the dentures processed with the SR-Ivocap system. The adaptation of the dentures reinforced with metal wire decreased in comparison with the unreinforced ones regardless of the polymerization method. This should be considered when metal wire is used clinically as reinforcement.

Acrylic Resins↗

The influence of fibre placement and position on the efficiency of reinforcement of fibre reinforced composite bridgework.

The effect of placement of ultra-high molecular weight polyethylene (UHMWPE) fibres on the flexural properties and fracture resistance of a direct dental composite was investigated. The UHMWPE fibres are increasingly being used for the reinforcement of laboratory fabricated resin composite crown and bridgework. The aim of this study was to assess the effect of a commonly used laboratory fabrication variable on the in vitro strength of beam shaped specimen simulating a three-unit fixed bridge. Four groups (10 specimens per group) of Herculite XRV were prepared for flexural modulus and strength testing after reinforcement with UHMWPE fibres. Two groups of control specimens were prepared without any fibre reinforcement. Half the specimen groups were stored in distilled water and the other groups were stored dry, both at 37 degrees C for 2 weeks before testing. The results of this study showed that placement of fibre at or slightly away from the tensile side improved the flexural properties of the composite in comparison with the unreinforced control specimen groups whilst the mode of failure differed according to fibre position. Scanning electron microscope (SEM) investigation revealed that placement of the fibre slightly away from the tensile side favoured crack development and propagation within the resin bridging the interfibre spaces in addition to debonding parallel to the direction of fibre placement. Laboratory fabrication variables may effect the strength of fibre reinforced bridgework significantly.

Analysis of Variance↗

Comparison of photo-activation versus chemical or dual-curing of resin-based luting cements regarding flexural strength, modulus and surface hardness.

This study investigated the efficiency of chemical activation of dual-cure resin-based luting cements as compared with light- and dual-curing. Curing was performed by (i) mixing base and catalyst without subsequent irradiation (chemical curing=CC), (ii) mixing base and catalyst with direct irradiation (dual-cure=DC) or with (iii) irradiation through 2.5 mm of leucite-reinforced glass-ceramics (IPS Empress, Ivoclar) (dual-cure through porcelain=DCtP), (iv) using only the base paste with direct irradiation (light-curing=LC) or with (v) irradiation through porcelain (light-curing through porcelain=LCtP). Specimens of four fine-hybrid DC resin composites and one self-cure hybrid resin composite (only CC) were prepared and tested after 24 h for flexural strength, modulus of elasticity (ISO 4049) and surface hardness (Vickers). For all materials and parameters, dual-curing produced higher values than LC, even when irradiation was performed through porcelain. Following self-curing without photo-activation, flexural strength was 68.9-85.9%, the modulus 59.2-94.5% and Vickers hardness 86.1-101.4% of the corresponding values obtained by dual-curing with direct irradiation. Light-curing through porcelain as compared with direct irradiation reduced the values for most parameters and materials. In contrast, dual-curing maintained flexural strength for all, the modulus for three and the hardness for one of the materials. The mechanical properties of the self-curing resin cement ranged between those of the DC materials.

Aluminum Silicates↗

Mechanical properties of resin cements with different activation modes.

Dual-cured cements have been studied in terms of the hardness or degree of conversion achieved with different curing modes. However, little emphasis is given to the influence of the curing method on other mechanical properties. This study investigated the flexural strength, flexural modulus and hardness of four proprietary resin cements. Materials tested were: Enforce and Variolink II (light-, self- and dual-cured), RelyX ARC (self- and dual-cured) and C & B (self-cured). Specimens were fractured using a three-point bending test. Pre-failure loads corresponding to specific displacements of the cross-head were used for flexural modulus calculation. Knoop hardness (KHN) was measured on fragments obtained after the flexural test. Tests were performed after 24 h storage at 37 degrees C. RelyX ARC dual-cured showed higher flexural strength than the other groups. RelyX ARC and Variolink II depended upon photo-activation to achieve higher hardness values. Enforce showed similar hardness for dual- and self-curing modes. No correlation was found between flexural strength and hardness, indicating that other factors besides the degree of cure (e.g. filler content and monomer type) affect the flexural strength of composites. No statistical difference was detected in the flexural modulus among the different groups.

Analysis of Variance↗

Structure-property relationship of cast Ti-Nb alloys.

The present work is a study of the microstructure, mechanical properties and corrosion behaviour of a series of binary Ti-Nb alloys with Nb contents up to 35 wt%, with emphasis placed on the structure-property relationship of the alloys. The results indicate that crystal structure and morphology of the Ti-Nb alloys are sensitive to the Nb content. The cast c.p. Ti has a hexagonal alpha phase with a lath type morphology. The alloys containing 15 wt% or less Nb are dominated by a hexagonal alpha' phase with an acicular, martensitic structure. When containing 17.5-25 wt% Nb, the alloys are primarily comprised of an orthorhombic alpha" phase. With 27.5 wt% Nb, metastable beta phase starts to be retained. With Nb contents higher than 30 wt%, the equi-axed beta phase is almost entirely retained. Small amounts of omega phase are detected in alloys containing 27.5 and 30 wt% Nb. Among all present alloys, Ti-10Nb and Ti-27.5Nb exhibit the highest strengths, while the alpha"-dominated (17.5 and 20Nb) and beta-dominated (> 30Nb) alloys have the lowest moduli. All Ti-Nb alloys show excellent corrosion resistance in Hank's solution at 37 degrees C. From the present data, the microhardness, bending strength and modulus of the various phases in Ti-Nb alloys are compared and tentatively summarized as follows: Microhardness: omega > alpha' > alpha" > beta > alpha (c.p. Ti) Bending strength: omega > alpha' > alpha" > beta > alpha (c.p. Ti) Bending modulus: omega > alpha (c.p. Ti) > alpha' > alpha" > beta

Corrosion↗

An investigation into the transverse and impact strength of "high strength" denture base acrylic resins.

A range of materials, often marketed as high strength resins is available. These materials are often expensive options to conventional heat-cured acrylic resin. The aim of this study was to investigate transverse and impact strength of five "high strength" acrylic resin denture base materials. A conventional heat-cured acrylic resin was used as a control. Specimens were prepared as specified in the International Standard Organization (ISO 1567: 1988) and British standards for the Testing of Denture Base Resins (BS 2487: 1989) and the British Standard Specification for Orthodontic resins (BS 6747: 1987) for transverse bend and impact testing. The impact strength was measured using a Zwick pendulum impact tester and the transverse bend strength measured using a Lloyds Instruments testing machine. The results showed that Metrocryl Hi, Luctitone 199 and N.D.S. Hi all had an impact strength which was significantly higher than the control. For the modulus of rupture, there was a significant difference between Sledgehammer and the other groups. There was no significant difference between the other groups and the control. For the modulus of elasticity, Sledgehammer produced the highest value followed by the control. The remaining four materials had a modulus of elasticity less than the control.

Acrylic Resins↗

Comparison of flexural properties of composite restoratives using the ISO and mini-flexural tests.

UNLABELLED: The purpose of this study was to investigate the flexural properties (flexural strength and flexural modulus) of four commercial composite restoratives (Silux Plus, Z100, Ariston and Surefil) using the ISO 4049 flexural test (IFT) and a mini-flexural test (MFT). Both tests involved the use of three-point loading and the same fixture. The difference between the tests was in the length of the composites specimens and the distance between the supports [20 mm (IFT) and 10 mm (MFT)]. Six specimens were made for each material and flexural test. Test specimens [25 x 2 x 2 mm (IFT) and 12 x 2 x 2 mm (MFT)] were fabricated according to manufacturers' recommendations. After light-polymerization, the specimens were stored in distilled water at 37 degrees C for 24 h. The specimens were subsequently blotted dry, measured and subjected to flexural testing using an Instron Universal Testing Machine with a crosshead speed of 0.75 mm min(-1). Data was analysed using anova/Scheffe's, paired samples test (P < 0.05) and Pearson's correlation (P < 0.01). For both IFT and MFT, results of statistical analysis of flexural strength were identical. Silux had significantly lower flexural strength compared with the other composites and the flexural strength of Ariston was significantly lower than Z100 and Surefil. For IFT, the flexural modulus of Z100 was significantly higher than Silux, Ariston and Surefil while for MFT, Silux had significantly lower modulus compared with Z100, Ariston and Surefil. A significant, strong and positive correlation (r = 0.95) was observed for flexural strength between IFT and MFT. Correlation for flexural modulus was also significant and positive but was weaker (r = 0.53). As MFT has the advantage of ease of specimen fabrication and is more clinically realistic, it is suggested for the testing of composite restoratives. CLINICAL RELEVANCE: The mini-flexural test may be better than the ISO flexural test for screening of composite restoratives for clinical applications.

Composite Resins↗

The effect of the addition of poly(methyl methacrylate) fibres on some properties of high strength heat-cured acrylic resin denture base material.

The self-reinforcement of acrylic resin with butadiene styrene surface treated poly(methyl methacrylate) fibres has been reported to have the potential to substantially improve the transverse bend strength of conventional heat-cured acrylic resin. The aim of this study was to investigate the effect of the addition of butadiene styrene surface treated poly(methyl methacrylate) fibres in cross-ply arrangement to high impact acrylic resin on the transverse and impact strength. Specimens were prepared as specified in the International Standard Organization and British Standards for the Testing of Denture Base Resins (ISO 1567, 1988; BS 2487, 1989) and the British Standard Specification for Orthodontic resins (BS 6747, 1987) for transverse bend and impact testing. The impact strength was measured using a Zwick pendulum impact tester and the transverse bend strength measured using a Lloyds Instruments testing machine. The results showed that the impact strength was not improved with the addition of fibres, high impact acrylic resin with fibres (LF) 11.1 kJ m-2 and high impact acrylic resin (L) (12.5 kJ m-2). The modulus of rupture was decreased with the addition of fibres (57.8 MPa) for (LF) compared with (60.4 MPa) for (L). The modulus of elasticity was also reduced with the addition of fibres (1834.9 MPa) (LF) and 2086.2 MPa (L) as was the peak load (LF) (50.8 N) and (L) (55.8 N). It was concluded that the addition of surface treated poly(methyl methacrylate) fibres in cross-ply arrangement to high strength acrylic resin did not produce an improvement in the impact or transverse strength and cannot be recommended as a method of reinforcement.

Acrylic Resins↗

Flexibility and stability of the structure of cytochromes P450 3A4 and BM-3.

The flexibility of the structure and compressibility of the respective active site of cytochromes P450 3A4 (CYP3A4) and BM-3 (CYP102) were studied using absorption spectroscopy in the ultraviolet and visual regions. Conformational changes in the overall protein structures of both CYP3A4 and CYP102 due to the effects of temperature and pressure are reversible. However, the enzymes differ in the properties of their active sites. The CYP3A4 enzyme denatures to the inactive P420 form relatively easy, at 3000 bar over half is converted to P420. The compressibility of its active site is lower than that of CYP102 and is greater with the substrate bound, which is in line with the observed lack of a stabilizing effect of the substrate on its conformation under pressure. In contrast, CYP102, although having the most compressible active site among the P450s, possesses a structure that does not denature easily to the inactive (P420) form under pressure. In this respect, it resembles the P450 isolated from acidothermophilic archaebacteria [McLean, M.A., Maves, S.A., Weiss, K.E., Krepich, S. & Sligar, S.G. (1998) Biochem. Biophys. Res. Commun. 252, 166-172].

Bacterial Proteins↗

Pollical oblique ligament in humans and non-human primates.

A morphological study of the oblique ligament in the thumb is presented. The ligament was consistently described in human specimens and compared with dissections of non-human primates from different species. The oblique ligament was found in some, but not all, specimens in each of the following species examined: chimpanzee, orangutan, gibbon, anubis baboon, hamadryas baboon, squirrel monkey, lemur and marmoset. A revised identity of the oblique ligament is proposed as a reinforced distal border of a fibro-osseous annular pollical flexor sheath and whose function is not independent of the flexor sheath. The constant presence and tendinous trait of the pollical oblique ligament in humans, when compared with non-human primates, supports the notion that the oblique ligament strengthens the pollical flexor sheath in humans for restraint of the flexor pollicis longus tendon during forceful precision pinching. A derivation of the pollical oblique ligament is considered as representing a vestigial radial limb of a flexor pollicis superficialis tendon in the thumb.

Animals↗

The effect of sandblasting treatment on endurance properties of titanium alloy hip prostheses.

Sandblasting is a procedure of increasing surface roughness. This treatment is common in the orthopedic field. An increased roughness may affect the endurance limit of the material. This study investigates the effect on the endurance limit of the Ti6Al4V due to two different sandblasting treatments: fine sandblasting and coarse sandblasting. Twenty hip stems, 10 finely sandblasted and 10 coarsely sandblasted, were tested under sinusoidal fluctuating bending. The staircase method was used to estimate the endurance limit of the material. The results show an important reduction in the endurance properties up to 40% for the coarsely sandblasted specimens. The failures of the sandblasted specimens were not due to material defects. Rather, the decreased endurance strength of the sandblasted stems was caused by surface defects, which act as crack initiators. By modulating the roughness with an appropriate sandblasting treatment, it is possible to limit the reduction in the endurance limit of the alloy.

Alloys↗

Preparation of bioabsorbable nerve guide tubes.

The use of bioabsorbable polymers in applications as temporary structural function, recovering damage in live tissues, is a promising research area. Membranes of poly(lactic acid) (PLA) may act as support to adhesion and cellular invasion or as devices for guided tissue regeneration (GTR). In this study, the same casting technique used to prepare membranes was used to prepare PLA tubes. These tubes can be used for tests in nerve guided regeneration (NGR). To improve flexibility of the device, a bioabsorbable plasticizer was added to the polymer. The initial results showed that the proposed technique allowed the preparation of flexible tubes that can be used for NGR.

Absorbable Implants↗

Development of catheters with low fiber background signals for Raman spectroscopic diagnosis applications.

Utilization of optical-fiber catheters can turn the Raman spectroscopy system into a powerful remote biomedical diagnostic probe. An in vivo (a qualitative and a quantitative) biochemical diagnosis of biotissues is possible by developing the Raman-fiber probes with a good flexibility and less background signals generated in the probes themselves. Considering the isotropic nature of Raman scattering, the amount of Raman signal guided through the fiber is expected to depend on the numerical aperture (NA) of the fiber. To study the dependence for catheter probes experimentally, various flexible probes (with small diameter fibers) with different combinations of numerical apertures and with different assembling materials (biocompatible) have been developed. The catheter probes have been characterized by collecting the near infrared excited Raman scattered light from cholesterol powder. The results demonstrate that the catheters with a combination of lower NA (0.12) fibers used for laser excitation and relatively higher NA (0.22) fibers for Raman signal collection will have lower background signals generated in the probes. Furthermore, the catheters with a black Teflon tubing cover and black epoxy resin adhesives were found to give better results.

Adhesives↗