Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Models, Anatomic”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

Multiple components in the unipolar electrogram: a simulation study in a three-dimensional model of ventricular myocardium.

INTRODUCTION: For many decades, the interpretation of unipolar electrograms (EGs) and ECGs was based on simple models of the heart as a current generator, e.g., the uniform dipole layer, and, more recently, the "oblique dipole layer." However, a number of recent and old experimental data are inconsistent with the predictions of these models. To address this problem, we implemented a numerical model simulating the spread of excitation through a parallelepipedal myocardial slab, with a view to identifying the factors that affect the shape, amplitude, and polarity of unipolar EGs generated by the spreading wavefront. METHODS AND RESULTS: The numerical model represents a portion of the left ventricular wall as a parallelepipedal slab (6.5 x 6.5 x 1 cm); the myocardial tissue is represented as an anisotropic bidomain with epi-endocardial rotation of fiber direction and unequal anisotropy ratio. Following point stimulation, excitation times in the entire volume are computed by using an eikonal formulation. Potential distributions are computed by assigning a fixed shape to the action potential profile. EGs at multiple sites in the volume are computed from the time varying potential distributions. The simulations show that the unipolar QRS waveforms are the sum of a "field" component, representing the effect of an approaching or receding wavefront on the potential recorded by a unipolar electrode, and a previously unrecognized "reference" component, which reflects the drift, during the spread of excitation, of the reference potential, which moves from near the positive to near the negative extreme of the potential distribution during the spread of excitation. CONCLUSION: The drift of the reference potential explains the inconsistencies between the predictions of the models and the actual shapes of the EGs. The drift modifies the slopes of EG waveforms during excitation and recovery and can be expected to affect the assessment of excitation and recovery times and QRS and ST-T areas. Removing the drift reestablishes consistency between potential distributions and electrographic waveforms.

Animals↗

Navigated vs. conventional implant insertion for maxillary single tooth replacement.

UNLABELLED: Abstract Introduction: Computer-guided navigation has proven a valuable tool in several surgical disciplines. During oral implant placement, its application is intended to accomplish optimal implant localization and to reduce the risk of damage to adjacent structures. The aim of this study was to compare the precision limits of conventional vs. navigated implant insertion in practice. MATERIALS AND METHODS: In cast models of the maxilla, implants were inserted to replace the left central incisor (n = 40) and the right canine (n = 40); each of those were inserted either conventionally (n = 20) or navigated (n = 20). Implant position, angulation and insertion depth were calculated from computer tomography scans of the implants that were connected to an index abutment of 40 cm length. RESULTS: The variations of implant positions were reduced for implants that were inserted by navigation (P < 0.05). In both the axial and the transversal plane, the variations of implant angulations were reduced for implants that were inserted by a navigation protocol (P < 0.05). The variations of insertion depth were less (P < 0.05) when the implants were placed by navigation in comparison with conventional insertion procedures. CONCLUSIONS: Given the experimental conditions, although they tried to mimic a clinical situation, no final conclusions can be drawn. The in vitro application of a navigation system resulted in an improved precision of insertion surgery regarding the position, angulation and depth of an implant. Clinical studies will have to prove if routine image guidance will result in superior surgical outcome.

Cuspid↗

Radiographic measurement of alveolar bone loss: a perspective in vitro.

In the present study, radiographs of a model simulating several degrees of alveolar bone height were taken at different vertical projection angles. Bone height was measured by three examiners utilizing a projection technique similar to that originally employed by Björn et al. (1966, 1969). Correlation coefficients of inter- and intra-examiner readings were found to be statistically significant. The 95% confidence interval of the mean deviation between the observed bone height and the true bone height was less than 5.5%. Further investigations are planned to determine whether this method of quantitating the information on radiographs exposed under various conditions is applicable in clinical practice.

Alveolar Process↗

Computerized evaluation of the effectiveness of subgingival scaling in jaw models. An introduction to the program developed at the School of Dentistry, University of Bergen.

The purpose of the present study was to improve the quality and the effectiveness of subgingival scaling managed by dental students. A training program was developed and the scaling was performed in jaw models. The teeth of these models were modified in order to ensure a quick inspection of the scaled root surfaces. Artificial "calculus", consisting of a mixture of shellac, umbra, pumice and plaster dissolved in ethanol, was painted on the root surfaces. Following the completion of the scaling test, remaining "calculus" was evaluated by adoption of a grading system. This system had scores from 0 to 3 and was defined by illustrated and described criteria. A menu-directed computer program was developed in order to ensure a rapid transformation of surface scores into clinically-related variables. The output from this program gave valuable information about the proficiency of individual students, as well as about the whole class of students as one body. Other advantages and potentials of this system are described.

Computers↗

Evaluation of a new periodontal curet. An in vitro study.

Removal of plaque and calculus from subgingival root surfaces is a fundamental aspect of periodontal therapy. A new type of periodontal curet (Gracey Curvette Sub-0) has been designed to better adapt to the root surfaces that may be encountered in periodontal pockets of incisor teeth. The new curet (test) was compared to a Gracey curet 1/2 (conventional) in their ability to remove deposits from the subgingival root surfaces of incisor teeth in an in vitro model. A dentiform model mounted on a dental chair was used with artificial gingiva, 6 mm pocket depths and subgingival root surfaces covered with black enamel paint. 2 groups of 12 hygienists used, on a timed basis, either the test or conventional curet on 4 of the incisor teeth and then switched to the alternate instrument for the remaining four incisors. The extent of surface material removal was determined using a computerized video routine. The test curet removed significantly (p less than 0.001) more of the surface material from all subgingival incisor root surfaces than the conventional curet (60.7% versus 46.3%). Both instruments were most effective at labial surfaces. The test curet was least effective at proximal surfaces and the conventional curet least effective at lingual surfaces. The greatest statistical difference between instruments was apparent at lingual surfaces of maxillary incisors and the least at mesial surfaces of mandibular incisors.

Alveolar Bone Loss↗

An imaging routine for assessing the efficacy of instruments used for scaling and root planing.

Deposits of dental plaque or calculus are typically quantified using planimetric techniques. However, error is introduced into a quantitative analysis of plaque deposits using these methods, since they require a significant amount of human intervention. The purpose of this study is to describe and validate a computerized imaging routine which has the potential to objectively identify material on dental roots and measure the area covered by these deposits. Dentiform teeth with simulated plaque were videorecorded. A computer routine was developed based on a flood-fill algorithm which analyzed images of the dentiform teeth and determined the amount of simulated plaque on their root surfaces. Results showed that the dentiform teeth and their simulated plaque patterns are duplicated by the imaging routine in a rapid and reliable fashion. The system shows a high degree of accuracy with an average error factor of only 0.58%. As well, the system enables precise reproducibility with an average error factor of only 0.71%.

Algorithms↗

Three-dimensional replicas of pit and fissure morphology in human teeth.

Nuva Seal replicas of pits and fissures from surgically removed unerupted human third molars and premolars, and from erupted premolars extracted for orthodontic reasons, were examined in the scanning electron microscope. The results confirm that the morphology on occlusal surfaces of third molars is extremely variable with numerous pits of considerable length positioned at various angles relative to the fissures. In contrast, the morphology of unerupted and erupted premolars is simpler with fewer and shorter pits positioned perpendicular to the fissure. It is pointed out that fine details of the morphology are lost when reconstructions of the occlusal morphology are made from serial ground sections. However, such reconstructions seem to be less reliable in third molars than in premolars.

Bicuspid↗

New fabrication system for dental implant surgical stents: time-saving laboratory technique using a light-curing resin and transparent artificial teeth.

BACKGROUND: Surgical stents are a prerequisite for dental implant diagnosis. However, the traditional fabrication method including wax-up, investment, and resin polymerization is time consuming. PURPOSE: This article introduces a new fabrication system using a light-curing resin and transparent artificial teeth to reduce time spent in the laboratory. MATERIALS AND METHOD: The process of this system includes placing the light-curing resin and the artificial teeth on the partially edentulous dentition and alveolar ridge, making an appropriate pattern for the stent, light-curing for 5 minutes, briefly polishing, and making holes for titanium guide pins. RESULTS: This system requires only 30 to 40 minutes in the laboratory to complete a stent after mounting the casts on the articulator. Owing to the elasticity of the light-curing resin, this system eliminates the need for a blockout procedure on the undercuts of existing teeth on the casts, protects the casts from breakage, and provides the appropriate retention intraorally without any retainers. As well, titanium guide pins embedded in the stent were clearly identified by panoramic and computed tomographies. CONCLUSIONS: The new fabrication system proposed here can be time saving and, further, serve benefits for radiographic diagnosis.

Dental Implantation, Endosseous↗

Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study.

BACKGROUND: Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance during the whole treatment period. PURPOSE: The aim of the present study was to evaluate an immediate-loading treatment protocol, which included flapless surgery, implants placed in predetermined positions and connected to prefabricated provisional restorations, and the 3-year clinical results. MATERIALS AND METHODS: A total of 97 Brånemark System Mk IV implants (Nobel Biocare AB, Gothenburg, Sweden) with a machined surface were inserted in the maxillas of 46 patients. A presurgical three-dimensional model of the patients' soft tissue and underlying alveolar bone anatomy was created, which allowed the clinician to place the implants in predetermined positions and connect them to prefabricated provisional restorations. A surgical template with drilling guides corresponding to each implant was used. The apical part of the master guide was equipped with a circular "mucotome," which punched out a 5 mm hole in the mucosa to eliminate the need for flap elevation. The patients received 25 fixed partial prostheses and 27 single-tooth restorations. Bone quality and quantity were assessed. Radiographic examinations were performed on the day of surgery/loading and at the 1-, 2-, and 3-year follow-up visits. RESULTS: All implant sites showed intact buccal and lingual bone walls during surgery, confirming the accuracy of the bone-mapping procedure. The prefabricated temporary restorations fitted, meaning that the implants were positioned clinically in the same way as on the cast. Nine implants in eight patients failed during the first 8 weeks of loading. This resulted in a cumulative survival rate of 91% after 3 years of prosthetic load. The survival rate of splinted implants was 94%. The number of failed implants was significantly higher in cases of single-tooth replacements and placement in soft bone sites and smokers. The failed implants were successfully replaced according to a two-stage protocol. All patients finally received the expected restoration. The marginal bone resorption was on average 1.0 mm during the first year of loading, 0.4 mm during the second year, and 0.1 mm during the third year. CONCLUSIONS: The study confirmed the feasibility of an immediate-loading treatment protocol in the maxilla, which included flapless surgery, implants and abutments placed in predetermined positions, and prefabricated provisional restorations. All failures occurred within the first 2 months of loading. The unchanged survival rate and the low average bone loss found during the following 34-month study period indicate a good long-term prognosis for the performed immediate-loading treatment.

Adult↗

An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading.

PURPOSE: An image-guided system has been developed to drill a conventional surgical guide following a preoperative three-dimensional plan for accurate placement of implant on bone. The aim of this study is to illustrate how this system facilitates treatment of completely edentulous patients by modifying both surgical and prosthetic protocols, thereby making flapless surgery possible as well as the preparation of the transitional prosthesis before surgery. MATERIALS AND METHODS: This system was tested on 10 consecutive patients, placing all planned implants without raising the mucoperiosteal flap and with the connection of all implants to pre-angulated abutments. RESULTS: A 1-year follow-up demonstrated stable and properly functioning prostheses in all cases. CONCLUSIONS: This technique can be expected to flourish because implantology makes the highest demands on comfort, precision, and safety.

Dental Abutments↗

A surgical stent for the Brånemark Novum bone reduction procedure.

BACKGROUND: The Brånemark Novum concept (Nobel Biocare AB, Göteborg, Sweden) was introduced to load implants immediately with a definitive fixed prosthesis in the edentulous mandible. This concept is based on the use of prefabricated templates to allow precise placement of three implants and a prefabricated bar structure for the prosthetic procedure. To obtain three-dimensional stability in these prefabricated templates, surgical bone reduction may be necessary to obtain a stable adaptation between the templates and the recipient bone site. PURPOSE: The aim of this work was to design a surgical stent for predictable reduction of the residual alveolar crest prior to the implant placement procedures. MATERIALS AND METHODS: A predetermined alveolar crest platform based essentially on a lateral cephalometric radiographic evaluation was simulated on a cast in order to design a transparent resin surgical guide. The predictability potential of the procedure was then evaluated in 10 patients. The prosthetic outcomes were compared with those of a similar group of 10 patients treated without the presented stent by evaluating two factors, namely, the anterior dimensions of the prostheses and the required posterior adjustments of the upper bar. RESULTS: Correlation analysis of our series suggested a good predictability potential for this procedure (r = 0.9215). The mean anterior prosthetic dimension was 32% lower and was more predictable (narrow range of 8-12 mm vs broad range of 8-21 mm) when the stent was used. Furthermore, since half as many posterior adjustments of the upper bar were required, the laboratory procedure was facilitated. CONCLUSION: This individualized guide allows appropriate bone reduction for obtaining a predictable surgery and prosthetic stage.

Adult↗

A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study.

BACKGROUND: Based on three-dimensional implant planning software for computed tomographic (CT) scan data, customized surgical templates and final dental prostheses could be designed to ensure high precision transfer of the implant treatment planning to the operative field and an immediate rigid splinting of the installed implants, respectively. PURPOSE: The aim of the present study was to (1) evaluate a concept including a treatment planning procedure based on CT scan images and a prefabricated fixed prosthetic reconstruction for immediate function in upper jaws using a flapless surgical technique and (2) validate the universality of this concept in a prospective multicenter clinical study. MATERIALS AND METHODS: Twenty-seven consecutive patients with edentulous maxillae were included. Treatments were performed according to the Teeth-in-an-Hour concept (Nobel Biocare AB, Göteborg, Sweden), which includes a CT scan-derived customized surgical template for flapless surgery and a prefabricated prosthetic suprastructure. RESULTS: All patients received their final prosthetic restoration immediately after implant placement, that is, both the surgery and the prosthesis insertion were completed within approximately 1 hour. In the 24 patients followed for 1 year, all prostheses and individual implants were recorded as stable. CONCLUSION: The present prospective multicenter study indicates that the prefabrication, on the basis of models derived from three-dimensional oral implant planning software, of both surgical templates for flapless surgery and dental prostheses for immediate loading is a very reliable treatment option. It is evident that the same approach could be used for staged surgery and in partial edentulism.

Adult↗

Etiology, pathogenesis and prevention of neural tube defects.

Spina bifida, anencephaly, and encephalocele are commonly grouped together and termed neural tube defects (NTD). Failure of closure of the neural tube during development results in anencephaly or spina bifida aperta but encephaloceles are possibly post-closure defects. NTD are associated with a number of other central nervous system (CNS) and non-neural malformations. Racial, geographic and seasonal variations seem to affect their incidence. Etiology of NTD is unknown. Most of the non-syndromic NTD are of multifactorial origin. Recent in vitro and in vivo studies have highlighted the molecular mechanisms of neurulation in vertebrates but the morphologic development of human neural tube is poorly understood. A multisite closure theory, extrapolated directly from mouse experiments highlighted the clinical relevance of closure mechanisms to human NTD. Animal models, such as circle tail, curly tail, loop tail, shrm and numerous knockouts provide some insight into the mechanisms of NTD. Also available in the literature are a plethora of chemically induced preclosure and a few post-closure models of NTD, which highlight the fact that CNS malformations are of hetergeneitic nature. No Mendelian pattern of inheritance has been reported. Association with single gene defects, enhanced recurrence risk among siblings, and a higher frequency in twins than in singletons indicate the presence of a strong genetic contribution to the etiology of NTD. Non-availability of families with a significant number of NTD cases makes research into genetic causation of NTD difficult. Case reports and epidemiologic studies have implicated a number of chemicals, widely differing therapeutic drugs, environmental contaminants, pollutants, infectious agents, and solvents. Maternal hyperthermia, use of valproate by epileptic women during pregnancy, deficiency and excess of certain nutrients and chronic maternal diseases (e.g. diabetes mellitus) are reported to cause a manifold increase in the incidence of NTD. A host of suspected teratogens are also available in the literature. The UK and Hungarian studies showed that periconceptional supplementation of women with folate (FA) reduces significantly both the first occurrence and recurrence of NTD in the offspring. This led to mandatory periconceptional FA supplementation in a number of countries. Encouraged by the results of clinical studies, numerous laboratory investigations focused on the genes involved in the FA, vitamin B12 and homocysteine metabolism during neural tube development. As of today no clinical or experimental study has provided unequivocal evidence for a definitive role for any of these genes in the causation of NTD suggesting that a multitude of genes, growth factors and receptors interact in controlling neural tube development by yet unknown mechanisms. Future studies must address issues of gene-gene, gene-nutrient and gene-environment interactions in the pathogenesis of NTD.

Anencephaly↗

Convective heat transfer around an infant head.

Knowledge of heat and mass transfer between an infant and his environment is necessary to control hospital care conditions, or understand a pathology as Sudden Infant Death Syndrome (SIDS). This paper precises the particular importance of the heat transfer over the head and quantifies the influence of various parameters on natural convection heat transfer.

Bedding and Linens↗

Computational models of structure-function relationships in the pulmonary circulation and their validation.

The pulmonary airway, arterial, venous and capillary networks are vast complex branching and converging systems that are mechanically coupled to the surrounding lung tissue. Early studies that examined vascular or airway geometry relied on measurements from casts, but medical imaging now enables measurement of the lung in vivo, at controlled lung volumes. The high-quality data that imaging provides have prompted development of increasingly sophisticated models of the geometry of the airway and pulmonary vascular trees. The accurate spatial relationships between airway, vessel and tissue in these imaging-derived models are necessary for computational analysis that aims to elucidate regional airway-vessel-tissue interactions. Predictions of blood flow through multiscale imaging-derived models of the pulmonary arteries and capillary bed reveal geometry-dependent patterns of perfusion in response to gravity and lung orientation that cannot be predicted with simplified, summary representations of the pulmonary transport trees. Validation of such predictions against measures from functional imaging holds significant potential for explaining and differentiating normal and disease-related heterogeneity in regional blood flow calculated using perfusion imaging.

Computer Simulation↗