Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Biodegradable Delivery Systems”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

Degradable poly(amino alcohol esters) as potential DNA vectors with low cytotoxicity.

The synthesis of a new degradable polymer system, poly(amino alcohol esters) and the resulting polymers' potential for use in gene transfection vectors are reported. The polymerization proceeded in a one step reaction from commercially available bis(secondary amines) monomers (N,N'-dimethyl-1,3-propanediamine and N,N'-dimethyl-1,6-hexanediamine, respectively) through nucleophilic addition to the diglycidyl ester of dicarboxylic acid (diglycidyl adipate). Poly(amino alcohol ester) 1 and 2 were synthesized with a yield of 89% and 91% with Mn = 24,800 and Mn = 36,400, respectively. Poly(amino alcohol ester) 1 degraded hydrolytically in phosphate buffer at pH 7.4 with a half-life of approximately 5 days. Both polymers readily self-assembled with plasmid DNA into nanometer-sized DNA/polymer complexes less than 180 nm diameter and are significantly less cytotoxic than the commonly used DNA delivery polymer, poly(ethylene imine) (PEI).

3T3 Cells↗

Human recombinant EGF protein delivered by a biodegradable cell transplantation system.

We have previously shown a new approach to expand cultured human keratinocytes and reconstitute the epidermis in full-thickness wounds using a new microsperical transport system. This was a new approach to increase the cell yield for seeding without altering the anchoring proteins by enzymatic steps. That time we used Cytodex 3 which failed to be degraded and induced an inflammatory reaction in a t-cell-deficient organism. Therefore, we have investigated another microcarrier consisting of PLGA, which is a well-known carrier material for cell culture and transplantation. After coating the PLGA carrier with gelatine the seeding time of viable cells reached 4 h and the cell gain after 7 days of spinner culture was 16-fold. At 14 days after transplantation, we could detect a new stratified epithelium in our full-thickness wound healing model. Because cytokines play a major role in wound healing, we loaded this carrier material with different concentrations of rhEGF, showing a dose dependent release of the protein in vitro and in vivo. This result might lead to a different approach in the treatment of wounds.

Absorbable Implants↗

Inhibition of tumor growth by biodegradable microspheres containing all-trans-retinoic acid in a human head-and-neck cancer xenograft.

Retinoids play essential roles in the regulation of cell differentiation and in the proliferation of various epithelial tissues, and atRA is one such active metabolite of retinoids. However, despite the known functions of atRA, its clinical applications are limited due to the induced metabolism by the specific cytochrome P-450s in the liver. To overcome the limitation, parenteral administration of atRA-loaded biodegradable microspheres, the PDLLA/PLE microspheres containing atRA, was suggested previously. We evaluated chemotherapeutic efficacy of atRA-loaded microspheres in a human head-and-neck xenograft/nude mouse model. When atRA-loaded microspheres were administered s.c. at 200 mg/kg body weight to athymic nude mice, plasma concentration of atRA could be maintained in a range of 1.2 to 3.7 x 10(-8) M for 4 weeks. As a result, the tumor volume of human head-and-neck cancer was reduced compared to the control group by 51.3% (p < 0.01) at 14 days and by 49.2% (p < 0.05) at 28 days.

Animals↗

Preparation and characterization of injectable microspheres of contraceptive hormones.

Present study describes the development of a new formulation of levonorgestrel and ethinylestradiol based on double emulsion-solvent evaporation technique using poly(epsilon-caprolactone) (PCL) as biodegradable polymer. The effect of polymer concentration on microspheres and entrapment of drug into microspheres were studied. PCL was selected because of its hydrophobicity and advantages over other biodegradable polymers. Characterization of biodegradable polymer used for controlled drug delivery is essential to ensure reproducibility of in vitro and in vivo performances. The selected characterisation techniques established for PCL microspheres include its loading and entrapment efficiencies, DSC to analyse thermal behaviour, SEM to observe surface morphology, drug content of microspheres and in vitro release of drugs from microspheres. The SEM reports showed that microspheres were with smooth surface and DSC thermograms revealed no interaction between drug and polymer. The entrapment was found to be 58 and 47% for 1:10 and 1:5 batches and in vitro release studies showed that about 69.7% of LNG and 66.7% of EE from 1:10 batch and about 80% of LNG and 75.5% of EE from 1:5 batch for 150 days.

Contraceptives, Oral, Synthetic↗

Dual growth factor delivery from degradable oligo(poly(ethylene glycol) fumarate) hydrogel scaffolds for cartilage tissue engineering.

This work describes the development of a non-invasive means of simultaneously delivering insulin-like growth factor-1 (IGF-1) and transforming growth factor-beta1 (TGF-beta1) to injured cartilage tissue in a controlled manner. This novel delivery technology employs the water-soluble polymer, oligo(poly(ethylene glycol) fumarate) (OPF), in the fabrication of biodegradable hydrogels which encapsulate gelatin microparticles. Release studies first examined the effect of gelatin isoelectric point (IEP) and crosslinking extent on IGF-1 release from these microparticles. In the presence of collagenase, highly crosslinked, acidic gelatin (IEP=5.0) provided sustained release of IGF-1, 95.2+/-2.9% cumulative release at day 28, while less crosslinked microparticles and microparticles of alternate IEP exhibited similar release values after only 6 days. Encapsulation of these highly crosslinked microparticles in a network of OPF provided a means to further control release, reducing final cumulative release to 70.2+/-4.7% in collagenase-containing PBS. Final release values from OPF-gelatin microparticle composites could be altered by incorporating less crosslinked, non-loaded microparticles within these constructs. Finally, this technology was extended to the dual delivery of IGF-1 and TGF-beta1 by loading these growth factors into either the OPF hydrogel phase or gelatin microparticle phase of composites. Release profiles were successfully manipulated by altering the phase of growth factor loading and microparticle crosslinking extent. For instance, by loading TGF-beta1 into the gelatin microparticle phase, a burst release of 10.8+/-0.7% was achieved, while loading this growth factor into the OPF hydrogel phase resulted in a burst release of 25.2+/-1.5%. With either system, simultaneous, slow release of IGF-1 over a 4-week period was accomplished by selectively loading this protein into highly crosslinked, encapsulated microparticles. These results demonstrate the utility of these systems in future studies to assess the interplay and time course of multiple growth factors in cartilage repair.

Cartilage↗

Enzyme-responsive release of encapsulated proteins from biodegradable hollow capsules.

Biodegradable hollow capsules encapsulating proteins were prepared via layer-by-layer assembly of chitosan and dextran sulfate on protein-entrapping mesoporous silica particles and the subsequent removal of the silica. The enzymatic degradation of the capsules in the presence of chitosanase was explored by scanning electron microscopy (SEM). With increasing time, the chitosan component was degraded by chitosanase, and the capsules began to deform and were finally destroyed. Sustained release of the encapsulated proteins was attained by using the enzymatic degradation of the hollow capsules. The release behavior was successfully manipulated by altering the charge of capsule surface.

Animals↗

Sustained local drug delivery to the arterial wall via biodegradable microspheres.

This study was designed to evaluate the feasibility of applying locally delivered polylactic acid microspheres for drug delivery to the arterial wall. To study drug persistence, rhodamine-loaded microspheres were infused into one carotid artery of 14 rabbits and plain rhodamine solution into the other by using a porous balloon. To study tissue response, plain microspheres and dexamethasone-loaded microspheres were infused into the carotid arteries of another group of rabbits. To study the antiproliferative effects of locally delivered drug, 20 rabbits were subjected to overstretch balloon injury to both carotid arteries and divided into 4 groups: injury alone, plain microspheres, dexamethasone-loaded microspheres, and microspheres containing colchicine and dexamethasone. Fluorescent microspheres persisted in the vessel wall for 4 wk, whereas rhodamine without microspheres disappeared at 72 h. Histopathologic studies in arteries infused with unloaded microspheres showed inflammatory cell infiltrate with polymorphonuclear cells at 1 wk and macrophages and giant cells at 4 wk. Arteries infused with dexamethasone-loaded microspheres did not show any inflammatory cell infiltrate. Local delivery of dexamethasone or dexamethasone plus colchicine did not result in significant change in the intima-to-media ratio or in residual lumen following balloon injury. Polylactic acid microspheres may be used for prolonged delivery of drugs or other bioactive agents locally to the arterial wall. They induce an inflammatory reaction that is suppressable by dexamethasone in the microspheres. Dexamethasone or dexamethasone and colchicine delivered via this system, however, failed to reduce the degree of intimal hyperplasia after overstretch balloon injury to the rabbit carotid arteries.

Angioplasty, Balloon, Coronary↗

Folate receptor targeted biodegradable polymeric doxorubicin micelles.

Biodegradable polymeric micelles, self-assembled from a di-block copolymer of poly(D,L-lactic-co-glycolic acid) (PLGA) and poly(ethylene glycol) (PEG), were prepared to achieve folate receptor targeted delivery of doxorubicin (DOX). In the di-block copolymer structure of PLGA-b-PEG, DOX was chemically conjugated to a terminal end of PLGA to produce DOX-PLGA-mPEG, and folate was separately conjugated to a terminal end of PEG to produce PLGA-PEG-FOL. The two di-block copolymers with different functional moieties at their chains ends were physically mixed with free base DOX in an aqueous solution to form mixed micelles. It was expected that folate moieties were exposed on the micellar surface, while DOX was physically and chemically entrapped in the core of micelles. Flow cytometry and confocal image analysis revealed that folate conjugated mixed micelles exhibited far greater extent of cellular uptake than folate unconjugated micelles against KB cells over-expressing folate receptors on the surface. They also showed higher cytotoxicity than DOX, suggesting that folate receptor medicated endocytosis of the micelles played an important role in transporting an increased amount of DOX within cells. In vivo animal experiments, using a nude mice xenograft model, demonstrated that when systemically administered, tumor volume was significantly regressed. Biodistribution studies also indicated that an increased amount of DOX was accumulated in the tumor tissue.

Animals↗

A novel method for the preparation of biodegradable microspheres for protein drug delivery.

Microspheres are potential candidates for the protein drug delivery. In this work, we prepared polymer-coated starch/bovine serum albumin (BSA) microspheres using co-axial electrohydrodynamic atomization (CEHDA). First, starch solution in dimethyl sulphoxide (DMSO) was prepared and then an aqueous solution of BSA was added to it to make a starch-BSA solution. Subsequently, this solution was made to flow through the inner capillary, while the polymer, polydimethylsiloxane (PDMS), flowed through the outer capillary. On collection, filtration and subsequent drying, near-monodisperse microspheres of 5-6microm in size were obtained. The microspheres were characterized by Fourier-transform infrared (FT-IR) spectroscopy and scanning electron microscopy. Cumulative BSA release was investigated by UV spectroscopy. BSA structure and activity was preserved in the microspheres and its release in 0.01M phosphate buffered saline (PBS) was studied over a period of 8 days. There was an initial burst with 32wt% of total BSA released in 2h. Overall 75wt% of BSA was released over a 7 day period.

Dimethylpolysiloxanes↗

Fabrication of PLG microspheres with precisely controlled and monodisperse size distributions.

The size distribution of biodegradable polymer microspheres critically impacts the allowable routes of administration, biodistribution, and release rate of encapsulated compounds. We have developed a method for producing microspheres of precisely controlled and/or monodisperse size distributions. Our apparatus comprises spraying a polymer-containing solution through a nozzle with (i) acoustic excitation to produce uniform droplets, and (ii) an annular, non-solvent carrier stream allowing further control of the droplet size. We used this apparatus to fabricate poly(D,L-lactide-co-glycolide) (PLG) spheres. The acoustic excitation method, by itself, produced uniform microspheres as small as 30 microm in diameter in which > or =95% of the spheres were within 1.0-1.5 microm of the average. The carrier stream method alone allowed production of spheres as small as approximately 1-2 microm in diameter from a 100-microm diameter nozzle, but generated broader size distributions. By combining the two devices, we fabricated very uniform spheres with average diameters from approximately 5 to >500 microm. Furthermore, by discretely or continuously varying the experimental parameters, we fabricated microsphere populations with predefined size distributions. Finally, we demonstrate encapsulation and in vitro release of a model drug compound, rhodamine B. In summary, our apparatus provides unprecedented control of microsphere size and may allow development of advanced controlled-release delivery systems.

Algorithms↗

Biodegradable self-assembling PEG-copolymer as vehicle for poorly water-soluble drugs.

PURPOSE: To develop self-assembling systems increasing the solubility of poorly water-soluble drugs. METHODS: Low molecular weight liquid biodegradable copolymers were synthesized by ring-opening polymerization using caprolactone (CAP) and trimethylenecarbonate (TMC) as monomers. Various initiators were evaluated. The emulsifying and self-assembling properties were investigated by a water titration method. The self-assembling systems were characterized for size, shape, isotropic behavior, cloud point, surface charge, and critical micellar concentration in order to optimize the polymer synthesis. Finally, the improvement of solubility of model drugs was assessed. RESULTS: Only diblock monomethyl ether PEG-CAP/TMC copolymers synthesized with monomethyl ether polyethyleneglycol 550 to 2000 as initiator have shown self-assembling properties: upon dilution, these copolymers formed an isotropically clear solution with droplet sizes in the range of 20 to 100 nm. The hypothesis that these diblock polymers form micelles was confirmed by their low critical micellar concentration (10(-5) g/ml). The copolymers initated with mmePEG750 had a higher cloud point and better colloidal stability than those initiated with mmePEG 550. The solubility of the poorly water-soluble drugs was increased by 1 to 2 orders of magnitude. Good reproducibility was observed from batch to batch. CONCLUSIONS: The polyester diblock copolymer mmePEG750-CAP/TMC forms spontaneously stable micelles in aqueous medium and increases the solubility of lipophilic drugs. They are very promising vehicles for the oral delivery of poorly water-soluble drugs.

Biocompatible Materials↗

Prolonged regional nerve blockade. Injectable biodegradable bupivacaine/polyester microspheres.

BACKGROUND: Biodegradable microspheres are a useful method of drug delivery because they are both injectable and biodegradable, eliminating the need for surgical implantation or removal. Previous work has characterized implantable preparations of local anesthetics in polymer pellets for prolonged regional anesthesia. In this article, the authors characterize injectable suspensions of bupivacaine-polymer microspheres and examine whether they can produce prolonged blockade of the sciatic nerve in rats. METHODS: Microspheres were prepared using polylactic-co-glycolic acid polymers loaded with 75% w/w bupivacaine by a solvent evaporation method. Bupivacaine release from microspheres was determined in vitro by ultraviolet spectroscopy and scintillation counting. Sensory and motor blockade of the rat sciatic nerve were assessed in vivo after injection of microsphere suspensions. RESULTS: Depending on the type of microspheres, the dose, and the additive used, mean duration of sciatic nerve block ranged from 10 h to 5.5 days. Incorporation of 0.05% w/w dexamethasone into the microspheres resulted in significant prolongation of block (up to 13-fold), and only preparations that contained dexamethasone produced blocks lasting beyond 1 day. Bupivacaine was released in a controlled manner in vitro. Dexamethasone does not substantially slow bupivacaine release from microspheres in vitro. CONCLUSIONS: Prolonged percutaneous blockade of peripheral nerves is feasible. The recovery from blockade is complete, and plasma bupivacaine levels are far below the range associated with systemic toxicity. The mechanisms underlying the dexamethasone block-prolonging effect are under investigation.

Anesthetics, Local↗

Controlled delivery of inductive proteins, plasmid DNA and cells from tissue engineering matrices.

It has been estimated that half the annual health care budget in the United States is spent on patients suffering from tissue loss and late stage organ failure. Critical limitations inherent in traditional therapies call for novel tissue and organ replacement strategies. This paper discusses development of biomaterials for conductive, inductive and cell-based tissue replacement strategies. Biodegradable polymer scaffolds can be used as space-filling matrices for tissue development and barriers to migration of epithelial cells in tissue conductive approaches. Inductive approaches involve sustained delivery of bioactive factors, such as protein growth factors and DNA, to alter cell function in localized regions. Factors can be released from highly porous polymer scaffolds to allow factor delivery and tissue development to occur in concert. Cell-based approaches involve seeding of cells onto polymeric scaffolds in vitro and subsequent transplantation of the scaffold. New scaffold materials are being developed that address specific tissue engineering design requirements, and in some cases attempt to mimic natural extracellular matrices. These strategies together offer the possibility of predictably forming specific tissue structures, and may provide solutions to problems such as periodontal ligament detachment, alveolar bone resorption and furcation defects.

Absorbable Implants↗

Comparison of antibiotic release from polymethylmethacrylate beads and sponge collagen.

The rates of elution of tobramycin in vitro were compared for polymethylmethacrylate beads impregnated with the powder form and an alternative biodegradable substance, sponge collagen. The impregnated polymethylmethacrylate beads initially had a lower zone of inhibition, but the rate of release was slow in comparison with that of the impregnated sponge collagen. The sponge collagen delivered a higher dose faster and with a shorter duration than the polymethylmethacrylate beads with the same antibiotic concentration in vitro, but the beads delivered a therapeutic concentration for longer periods. Because it deteriorates rapidly, sponge collagen may be unsatisfactory as an agent of antibiotic delivery in patients who have chronic osteomyelitis; however, it may be useful for patients who have acute trauma with highly contaminated bone or soft tissue, or during hemiarthroplasty revision, to deliver a high local concentration of antibiotic for a short period of time.

Anti-Bacterial Agents↗

Development of Chronomers tm for narcotic antagonists.

The object of this program is to prepare a bioerodable naltrexone delivery system which can be implanted subcutaneously in humans and which can relieve the narcotic antagonist over 1-6 months at relatively constant and sufficient rates to block the euphoric effect of morphine based drugs. The system is composed of naltrexone uniformly dispered in a solid hydropholic CHRONOMER TM matrix which undergoes predictable surface erosion when exposed to an aqueous medium. Kinetic studies in vitro have been carried out during the course of the program to determine the best composition for the system. Toxilogical studies conducted at ALZA during the past 2 years have not revealed limiting adverse effects of either the CHRONOMER TM materials or their hydrolysis products. The tail-flick test procedure was used to measure the effectiveness of naltrexone to antagonize the analgesis of morphine in rats. Naltrexone infused intravenously at doses of 4 and 16 ug/kg/hr resulted in, after 6 hours, 54 and 89% antagonism, respectively, against a 63.5% effective dose of morphine. Perliminary sterilization studies showed that no adverse effects to CHRONOMER TM/naltrexone systems occurred after exposure to 2.5 or 5.0 mrads of 60CO irradiation.

Animals↗

Potential of polymer microencapsulation technology for vaccine innovation.

Biodegradable polymer microspheres or microcapsules developed over the past decade for reliable, preprogrammed release of contraceptive steroids have significant potential for adaptation to antigen release for immunization. In addition, polymeric encapsulation of antigens could prevent the acid and enzymatic degradation that has been a barrier to the development of oral vaccines. This review summarizes the published experience with microencapsulated hormones and antigens, describes the process of microsphere production, discusses the strengths and weaknesses of this approach to immunization, and outlines the gaps in knowledge. Microsphere technology has the potential benefits of reducing the number of inoculations, enhancing the immune response via both parenteral and oral vaccination routes, and in reducing the total antigen dose required to achieve immune protection.

Animals↗

Ketoprofen-poly(D,L-lactic-co-glycolic acid) microspheres: influence of manufacturing parameters and type of polymer on the release characteristics.

The effect of manufacturing parameters on the size and drug-loading of ketoprofen-containing biodegradable and biocompatible poly(DL-lactic-co-glycolic acid) (PLGA) microspheres prepared by the solvent evaporation method was investigated. For both drug-free and drug-loaded microspheres, smaller microspheres with a narrower size distribution were obtained when the stirring rate or the volume of the organic phase was increased. Incorporation of ketoprofen was found to increase with increasing volume of the organic phase and decreasing pH of the aqueous phase, but was independent of the acidity and the inherent viscosity of the PLGA used. The biphasic release profile of ketoprofen from the microspheres was dependent on the type of PLGA as well as the size and drug-loading, two parameters governed by the manufacturing process. The first burst effect was found to increase with the drug content, reduction of size of the microspheres and increasing inherent viscosity of the matrix, whereas acidity of the PLGA had no effect on the release of this acidic drug. A vigorous first burst effect was associated with reduced sustained delivery of ketoprofen, the rate of the delayed release phase being dependent on the inherent viscosity of the matrix, the size, the payload and the pH during preparation of the microspheres. Thus, by selection of the manufacturing parameters and the type of PLGA, it is possible to design a controlled drug delivery system for the prolonged release of ketoprofen, improving therapy by possible reduction of time intervals between peroral administration and reduction of local gastrointestinal side effects.

Anti-Inflammatory Agents, Non-Steroidal↗

Development of Chronomers for narcotic antagonists.

The object of this program is to prepare a bioerodable naltrexone delivery system which can be implanted subcataneously in human and which can relieve the narcotic antagonist over 1-6 months at relatively constant and sufficient rates to block the euphoric effect of morphine based drugs. The system is composed of naltrexone uniformly dispersed in a solid hydropholic CHRONOMER matrix which undergoes predictable surface erosion when exposed to an aqueous medium. Kinetic studies in vitro have been carried out during the course of the program to determine the best composition for the system. Toxilogical studies conducted at ALZA during the past 2 years have not revealed limiting adverse effects of either the CHRONOMER materials or their hydrolysis products. The tail-flick test procedure was used to measure the effectiveness of naltrexone to antagonize the analgesis of morphine in rats. Naltrexone infused intravenously at doses of 4 and 16 ug/kg/hr resulted in, after 6 hours, 54 and 89 per cent antagonism, respectively, against a 63.5 per cent effective dose of morphine. Preliminary sterilization studies showed that no adverse effects to CHRONOMER/naltrexone systems occurred after exposure to 2.5 or 5.0 mrads of 60Co irradiation.

Animals↗