Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Beta Particles”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

High-dose intravascular beta-radiation after de novo stent implantation induces coronary artery spasm.

BACKGROUND: Intracoronary brachytherapy is effective in preventing restenosis after coronary interventions. However, in vitro and animal studies have shown that irradiation produces immediate and sustained endothelial dysfunction. This study assesses the clinical relevance of impaired vasomotoric function induced by brachytherapy. METHODS AND RESULTS: We analyzed the occurrence of postradiation coronary artery spasms in 1 animal study and 2 clinical trials investigating the effects of high-dose intracoronary beta-radiation after de novo coronary artery stenting. Irradiated segments (IRSs) proximal and distal to the stent were studied by quantitative coronary angiography after stenting, after radiation, and at the end of the procedure. There was an 67% overall incidence of coronary artery spasm in the IRSs immediately after beta-radiation compared with 9% after sham treatment (P<0.001). Whereas in most cases this phenomenon was only minor or moderate, in 12 cases, 4 (22%) animals and 8 (28%) patients, severe coronary spasm (>90% diameter stenosis) with significant ECG-changes or hemodynamic instability was observed. Relief of spasms was protracted (mean time until complete relief of spasm 423+/-122 seconds) and required repetitive intracoronary administration of nitroglycerin (mean dose: 1.2+/-0.6 mg). CONCLUSIONS: Vasoconstriction is a frequent reaction of coronary arteries after high-dose intracoronary beta-radiation, necessitating repetitive administration of vasodilators.

Animals↗

Dosimetric measurements in isolated human coronary arteries: comparison of commercially available iridium(192) with strontium/yttrium(90) emitters.

BACKGROUND: Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources (beta- and gamma-emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the adventitia in diseased and stented human coronary arteries for (192)Ir and (90)Sr/Y emitters in routine use. In contrast to previously published work, we performed dosimetry instead of calculating depth-dose distribution by use of the Monte Carlo system. METHODS AND RESULTS: Postmortem calcified human coronary artery segments were stented and placed in an organ bath. Commercially available gamma-emitters ((192)Ir; Cordis Checkmate) and beta-emitters ((90)Sr/Y; Novoste Beta-Cath) were used. Relative dose distributions along the adventitia were measured by a specially designed scintillation detector system. Whereas dose perturbations caused by stents and calcified plaque were negligible for the (192)Ir source, radiation from the beta source was significantly impaired (as much as 40%) at the level of the adventitia (3.0-mm vessel diameter). Dose perturbation was clearly dependent on the extent and severity of calcification, less affected by stent material. CONCLUSIONS: Dose perturbation caused by calcified plaque and metallic stents is significant for beta-sources. This dosimetric difference between beta- and gamma-emitters in diseased coronary arteries should be considered when calculating doses in intravascular brachytherapy.

Beta Particles↗

Randomized trial of 90Sr/90Y beta-radiation versus placebo control for treatment of in-stent restenosis.

BACKGROUND: After conventional treatment of in-stent restenosis, the incidence of recurrent clinical restenosis may approach 40%. We report the first multicenter, blinded, and randomized trial of intracoronary radiation with the use of a 90Sr/90Y beta-source for the treatment of in-stent restenosis. METHODS AND RESULTS: After successful catheter-based treatment of in-stent restenosis, 476 patients were randomly assigned to receive an intracoronary catheter containing either 90Sr/90Y (n=244) or placebo (n=232) sources. The prescribed dose 2 mm from the center of the source was 18.4 Gy for vessels between 2.70 and 3.35 mm in diameter and 23.0 Gy for vessels between 3.36 and 4.0 mm. The primary end point, ie, clinically driven target-vessel revascularization by 8 months, was observed in 56 (26.8%) of the patients assigned to placebo and 39 (17.0%) of the patients assigned to radiation (P=0.015). The incidence of the composite including death, myocardial infarction, and target-vessel revascularization was observed in 60 (28.7%) of the patients assigned to placebo and 44 (19.1%) of the patients assigned to radiation (P=0.024). Binary 8-month angiographic restenosis (> or =50% diameter stenosis) within the entire segment treated with radiation was reduced from 45.2% in the placebo-treated patients to 28.8% in the 90Sr/90Y-treated patients (P=0.001). Stent thromboses occurred in 1 patient assigned to placebo <24 hours after the procedure and in 1 patient assigned to 90Sr/90Y at day 244. CONCLUSIONS: The results of this study demonstrated that beta-radiation using 90Sr/90Y is both safe and effective for preventing recurrence in patients with in-stent restenosis.

Beta Particles↗

Delivered dose and vascular response after beta-radiation for in-stent restenosis: retrospective dosimetry and volumetric intravascular ultrasound analysis.

BACKGROUND: Observations from previous intracoronary radiation therapy trials noted a considerable discrepancy between the prescribed radiation dose and the dose actually delivered. The aims of this study were to investigate the effect of actual delivered dose on vascular changes and to test the appropriateness of the current dose prescription. METHODS AND RESULTS: Serial volumetric intravascular ultrasound (IVUS) analysis was performed in 30 in-stent restenosis cases treated with a 40-mm (90)Sr/Y source train. The fixed dose was prescribed at 2 mm from the centerline of the source train (18.4 Gy at 2 mm for reference diameter < or =3.35 mm and 23 Gy for diameter > or =3.36 mm). Only stent segments with full radiation coverage and device injury were enrolled and divided into 2-mm-long subsegments (n=202). D(S90)EEM (the minimum dose absorbed by 90% of the external elastic membrane surface) was calculated as the delivered dose corresponding to each segment, assuming that the radiation catheter occupied the same position in the vessel as the IVUS catheter. Mean D(S90)EEM of 23.5+/-5.82 Gy (range 12.3 to 41.7 Gy) was delivered to these subsegments. Overall, intimal hyperplasia volume remained constant from postintervention to follow-up (2.23+/-1.10 to 2.32+/-1.09 mm3/m; P=NS). Regression analysis revealed there was no correlation between delivered dose intensity and changes in intimal hyperplasia volume. No particular dose-dependent complications were appreciated in this delivered dose range. CONCLUSIONS: The current dose-prescription protocol of (90)Sr/Y radiation to native in-stent restenosis lesions may provide substantial inhibition of neointimal reproliferation regardless of the actual delivered dose intensity.

Beta Particles↗

Intracoronary beta-irradiation with a rhenium-188-filled balloon catheter: a randomized trial in patients with de novo and restenotic lesions.

BACKGROUND: Restenosis requiring reintervention is the main limitation of coronary angioplasty. Intracoronary irradiation reduces neointimal proliferation. We studied the efficacy of a self-centering liquid rhenium-188-filled balloon catheter for coronary beta-brachytherapy. METHODS AND RESULTS: After successful coronary angioplasty with or without stenting, 225 patients (71% de novo lesions) were randomly assigned to receive 22.5 Gy intravascular beta-irradiation in 0.5-mm tissue depth (n=113) or to receive no additional intervention (n=112). Clinical and procedural data did not differ between the groups except a higher rate of stenting in the control group (63%) compared with the rhenium-188 group (45%, P<0.02). After 6 months of follow-up, late loss was significantly lower in the irradiated group compared with the control group, both of the target lesion (0.11+/-0.54 versus 0.69+/-0.81 mm, P<0.0001) and of the total segment (0.22+/-0.67 versus 0.70+/-0.82 mm, P<0.0001). This was also evident in the subgroup of patients with de novo lesions and independent from stenting. Binary restenosis rates were significantly lower at the target lesion (6.3% versus 27.5%, P<0.0001) and of the total segment (12.6% versus 28.6%, P<0.007) after rhenium-188 brachytherapy compared with the control group. Target vessel revascularization rate was significantly lower in the rhenium-188 (6.3%) compared with the control group (19.8%, P=0.006). CONCLUSIONS: Intracoronary beta-brachytherapy with a rhenium-188 liquid-filled balloon is safe and efficiently reduces restenosis and revascularization rates after coronary angioplasty.

Angioplasty, Balloon, Coronary↗

Repeat intracoronary radiation for recurrent in-stent restenosis in patients who failed intracoronary radiation.

BACKGROUND: Intracoronary radiation therapy (IRT) is the only proven treatment for in-stent restenosis (ISR). It is, however, associated with a significant failure rate. The present study evaluated the outcomes of patients who underwent repeat intracoronary radiation for recurrent ISR. METHODS AND RESULTS: Fifty-one consecutive patients who failed a previous radiation treatment, presented with angina and angiographic evidence of ISR, and were treated with percutaneous coronary intervention (PCI) and repeat radiation to the same segment were studied. Twenty-five patients were treated with gamma radiation in a dose of 15 Gy, and 26 were treated with beta radiation doses of 18.3 to 23 Gy. The mean cumulative dose for this cohort was 39.5+/-11.9 Gy (range, 29 to 75.6 Gy). The outcomes of those patients were compared with outcomes of 299 patients who also failed initial radiation but were treated with repeat conventional PCI to a previously irradiated segment without repeat radiation. At 9 months after treatment, the repeat-IRT group had lower rates of target lesion revascularization (23.5% versus 54.6%; P<0.001) and major adverse cardiac events, including target vessel revascularization (29.4% versus 61.3%; P<0.001). At 9 months, patients with repeat IRT were free of angiographic and clinical events related to the radiation therapy. CONCLUSIONS: Repeat gamma or beta radiation to treat failed IRT for ISR after conventional PCI is safe and effective at 9 months and should be considered as a therapeutic option for this difficult patient subset.

Angina Pectoris↗

Beta-radiation for the creation of linear lesions in the canine atrium.

BACKGROUND: Creating linear lesions is important for the treatment of arrhythmias such as atrial flutter and fibrillation. Making these lesions with standard radiofrequency catheters can be difficult and may result in charring and thrombosis. The purpose of this study was to evaluate beta-radiation as a novel energy source for creating linear myocardial lesions. METHODS AND RESULTS: Eight dogs with intact conduction across the cavotricuspid isthmus were studied. The isthmus was irradiated (25 to 50 Gy) with strontium/yttrium-90 delivered via a deflectable 7F catheter (Novoste Corporation). There were no immediate effects, but bidirectional conduction block developed during follow-up studies in 7 of 8 dogs. The dog without conduction block received 25 Gy. After the animals were euthanized, histology revealed transmural, linear areas of fibrosis without any thrombus. CONCLUSIONS: Beta-radiation can safely and effectively create linear lesions that are contiguous and nonthrombogenic. This energy source may become an interesting adjunct to radiofrequency for the treatment of atrial flutter and fibrillation.

Animals↗

Geometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study.

BACKGROUND: Endovascular radiation appears to inhibit intimal thickening after overstretching balloon injury in animal models. The effect of brachytherapy on vascular remodeling is unknown. The aim of the study was to determine the evolution of coronary vessel dimensions after intracoronary irradiation after successful balloon angioplasty in humans. METHODS AND RESULTS: Twenty-one consecutive patients treated with balloon angioplasty and beta-radiation according to the Beta Energy Restenosis Trial-1.5 were included in the study. Volumetric assessment of the irradiated segment and both edges was performed after brachytherapy and at 6-month follow-up. Intravascular ultrasound images were acquired by means of ECG-triggered pullback, and 3-D reconstruction was performed by automated edge detection, allowing the calculation of lumen, plaque, and external elastic membrane (EEM) volumes. In the irradiated segments, mean EEM and plaque volumes increased significantly (451+/-128 to 490.9+/-159 mm(3) and 201.2+/-59 to 241.7+/-74 mm(3); P=0.01 and P=0.001, respectively), whereas luminal volume remained unchanged (250.8+/-91 to 249.2+/-102 mm(3); P=NS). The edges demonstrated an increase in mean plaque volume (26.8+/-12 to 32. 6+/-10 mm(3), P=0.0001) and no net change in mean EEM volume (71. 4+/-24 to 70.9+/-24 mm(3), P=NS), resulting in a decrease in mean luminal volume (44.6+/-16 to 38.3+/-16 mm(3), P=0.01). CONCLUSIONS: A different pattern of remodeling is observed in coronary segments treated with beta-radiation after successful balloon angioplasty. In the irradiated segments, the adaptive increase of EEM volume appears to be the major contributor to the luminal volume at follow-up. Conversely, both edges showed an increase in plaque volume without a net change in EEM volume.

Angioplasty, Balloon↗

Preserved endothelium-dependent vasodilation in coronary segments previously treated with balloon angioplasty and intracoronary irradiation.

BACKGROUND: Abnormal endothelium-dependent coronary vasomotion has been reported after balloon angioplasty (BA), as well as after intracoronary radiation. However, the long-term effect on coronary vasomotion is not known. The aim of this study was to evaluate the long-term vasomotion of coronary segments treated with BA and brachytherapy. METHODS AND RESULTS: Patients with single de novo lesions treated either with BA followed by intracoronary beta-irradiation (according to the Beta Energy Restenosis Trial-1.5) or with BA alone were eligible. Of these groups, those patients in stable condition who returned for 6-month angiographic follow-up formed the study population (n=19, irradiated group and n=11, control group). Endothelium-dependent coronary vasomotion was assessed by selective infusion of serial doses of acetylcholine (ACh) proximally to the treated area. Mean luminal diameter was calculated by quantitative coronary angiography both in the treated area and in distal segments. Endothelial dysfunction was defined as a vasoconstriction after the maximal dose of ACh (10(-6) mol/L). Seventeen irradiated segments (89.5%) demonstrated normal endothelial function. In contrast, 10 distal nonirradiated segments (53%) and 5 control segments (45%) demonstrated endothelium-dependent vasoconstriction (-19+/-17% and -9.0+/-5%, respectively). Mean percentage of change in mean luminal diameter after ACh was significantly higher in irradiated segments (P=0.01). CONCLUSIONS: Endothelium-dependent vasomotion of coronary segments treated with BA followed by beta-radiation is restored in the majority of stable patients at 6-month follow-up. This functional response appeared to be better than those documented both in the distal segments and in segments treated with BA alone.

Acetylcholine↗

Effects of intracoronary radiation on thrombosis after balloon overstretch injury in the porcine model.

BACKGROUND: The main complications of PTCA remain thrombosis and restenosis. Recent studies have demonstrated reduction in the neointimal hyperplasia after intracoronary radiation (IR) with doses of 10 to 25 Gy of ionizing radiation delivered by either beta- or gamma-emitters to injured vessels. The purpose of this study was to examine the effect of ionizing radiation on the thrombosis rate (TR) of injured porcine coronary arteries. METHODS AND RESULTS: Thirty-four juvenile swine (63 coronary arteries) were subjected to overstretch balloon injury followed by IR with doses of 0 to 18 Gy of either beta- or gamma-radiation. Two weeks after treatment, tissue sections were perfusion-fixed, stained with hematoxylin-eosin and Verhoeff-van Gieson's stain, and analyzed for presence of a thrombus, thrombus morphology, and neointima formation by computer-assisted histomorphometry techniques. Although the overall TR increased dose-dependently from 0 to 18 Gy prescribed dose, luminal thrombi decreased. Thrombus area also decreased with increasing radiation dose, whether assessed at the prescription point or at the luminal surface, which corresponded to decreased intimal area. Furthermore, luminal thrombi present after IR tended to consist mostly of fibrin and thus were less organized than in controls. CONCLUSIONS: These results suggest that IR induces thrombosis but does not necessarily compromise the lumen. Strategies for reducing TR may further decrease intimal area as well as increasing the safety of this therapy.

Angioplasty, Balloon, Coronary↗

Short- and intermediate-term results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease: The Milan Dose-Response Study.

BACKGROUND: Radioactive (32)P beta-emitting stents have been shown to reduce intrastent neointimal hyperplasia in a substantial dose-related manner in the animal model. The aim of this dose-response study was to evaluate, in the clinical setting, the safety and efficacy at 6-month follow-up of this approach to reducing restenosis. METHODS AND RESULTS: A total of 122 (32)P radioactive beta-emitting stents (initially the Palmaz-Schatz and later the BX Isostent) with an activity level of 0.75 to 3.0 microCi (group 1), 3.0 to 6.0 microCi (group 2), and 6.0 to 12.0 microCi (group 3) were implanted in 91 lesions in 82 patients. There were no procedural events. At 6-month follow-up, no deaths had occurred, and only 1 patient had stent thrombosis. Pure intrastent binary restenosis was 16% in group 1, 3% in group 2, and 0% in group 3. However, intralesion restenosis was 52% in group 1, 41% in group 2, and 50% in group 3. CONCLUSIONS: The use of (32)P radioactive beta-emitting stents in patients with CAD is feasible. At 6-month follow-up, intrastent neointimal hyperplasia was reduced in a dose-related manner. However, in the 3 groups, intralesion restenosis was high because of a high late lumen loss in the reference segments at the stent edges, possibly as a result of a low activity level of radiation at the edges of the stent combined with an aggressive approach to stenting. We called this "edge effect" the "candy wrapper."

Analysis of Variance↗

Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis.

BACKGROUND: Intracoronary gamma-radiation therapy reduces recurrent in-stent restenosis (ISR). This study, BETA WRIST (Washington Radiation for In-Stent restenosis Trial) was designed to examine the efficacy and safety of the beta-emitter 90-yttrium for the prevention of recurrent ISR. METHODS AND RESULTS: A total of 50 consecutive patients with ISR in native coronaries underwent percutaneous transluminal coronary angioplasty, laser angioplasty, rotational atherectomy, and/or stent implantation. Afterward, a segmented balloon catheter was positioned and automatically loaded with a 90-yttrium, 0.014-inch source wire that was 29 mm in length to deliver a dose of 20.6 Gy at 1.0 mm from the balloon surface. In 17 patients, manual stepping of the radiation catheter was necessary for lesions >25 mm in length. The radiation was delivered successfully to all patients, with a mean dwell time of 3.0+/-0.4 minutes. Fractionation of the dose due to ischemia was required in 11 patients. At 6 months, the binary angiographic restenosis rate was 22%, the target lesion revascularization rate was 26%, and the target vessel revascularization rate was 34%; all rates were significantly lower than those of the placebo group of gamma-WRIST. CONCLUSIONS: beta-Radiation with a 90-yttrium source used as adjunct therapy for patients with ISR results in a lower-than-expected rate of angiographic and clinical restenosis.

Adult↗

Intracoronary beta-irradiation with a liquid (188)re-filled balloon: six-month results from a clinical safety and feasibility study.

BACKGROUND: Coronary irradiation is a new concept to reduce restenosis. We evaluated the feasibility and safety of intracoronary irradiation with a balloon catheter filled with (188)Re, a liquid, high-energy beta-emitter. METHODS AND RESULTS: Irradiation with 15 Gy at 0.5-mm tissue depth was performed in 28 lesions after balloon dilation (n=9) or stenting (n=19). Lesions included 19 de novo stenoses, 4 occlusions, and 5 restenoses. Irradiation time was 515+/-199 seconds in 1 to 4 fractions. There were no procedural complications. One patient died of noncardiac causes at day 23. One asymptomatic patient refused 6-month angiography. Quantitative angiography after intervention showed a reference diameter of 2. 77+/-0.35 mm and a minimal lumen diameter of 2.36+/-0.43 mm. At 6-month follow-up, minimal lumen diameter was 1.45+/-0.88 mm (late loss index 0.57). Target lesion restenosis rate (>50% in diameter) was low (12%; 3 of 26). In addition, we observed 9 stenoses at the proximal or distal end of the irradiation zone, potentially caused by the short irradiation segment and the decreasing irradiation dose at its borders ("edge" stenoses). The total restenosis rate was 46% and was significantly lower (29% vs 70%, P=0.042) when the length of the irradiated segment was more than twice the lesion length. CONCLUSIONS: Coronary irradiation with a (188)Re-filled balloon is technically feasible and safe, requiring only standard percutaneous transluminal coronary angioplasty techniques. The target lesion restenosis rate was low. The observed edge stenoses appear to be avoidable by increasing the length of the irradiated segment.

Adolescent↗

Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy.

BACKGROUND: A recognized limitation of endovascular beta-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary beta-radiation. METHODS AND RESULTS: We analyzed 50 consecutive patients treated with beta-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84+/-0.6 versus 0.15+/-0.4 and 0.09+/-0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). CONCLUSIONS: These data support the hypothesis that the combination of injury and low-dose beta-radiation induces deleterious outcome.

Angioplasty, Balloon, Coronary↗

Residual plaque burden, delivered dose, and tissue composition predict 6-month outcome after balloon angioplasty and beta-radiation therapy.

BACKGROUND: Inhomogeneity of dose distribution and anatomic aspects of the atherosclerotic plaque may influence the outcome of irradiated lesions after balloon angioplasty (BA). We evaluated the influence of delivered dose and morphological characteristics of coronary stenoses treated with beta-radiation after BA. METHODS AND RESULTS: Eighteen consecutive patients treated according to the Beta Energy Restenosis Trial 1.5 were included in the study. The site of angioplasty was irradiated with the use of a beta-emitting (90)Sr/(90)Y source. With the side branches used as anatomic landmarks, the irradiated area was identified and volumetric assessment was performed by 3D intracoronary ultrasound imaging after treatment and at 6 months. The type of tissue, the presence of dissection, and the vessel volumes were assessed every 2 mm within the irradiated area. The minimal dose absorbed by 90% of the adventitial volume (D(v90)Adv) was calculated in each 2-mm segment. Diffuse calcified subsegments and those containing side branches were excluded. Two hundred six coronary subsegments were studied. Of those, 55 were defined as soft, 129 as hard, and 22 as normal/intimal thickening. Plaque volume showed less increase in hard segments as compared with soft and normal/intimal thickening segments (P<0.0001). D(v90)Adv was associated with plaque volume at follow-up after a polynomial equation with linear and nonlinear components (r = 0.71; P = 0.0001). The multivariate regression analysis identified the independent predictors of the plaque volume at follow-up: plaque volume after treatment, D(v90)Adv, and type of plaque. CONCLUSIONS: Residual plaque burden, delivered dose, and tiss composition play a fundamental role in the volumetric outcome at 6-month follow-up after beta-radiation therapy and BA.

Angioplasty, Balloon, Coronary↗

Three-dimensional intravascular ultrasound assessment of noninjured edges of beta-irradiated coronary segments.

BACKGROUND: The "edge effect," late lumen loss at the margins of the treated segment, has become an important issue in the field of coronary brachytherapy. The aim of the present study was to assess the edge effect in noninjured margins adjacent to the irradiated segments after catheter-based intracoronary beta-irradiation. METHODS AND RESULTS: Fifty-three vessels were assessed by means of 3-dimensional intravascular ultrasound after the procedure and at 6- to 8-month follow-up. Fourteen vessels (placebo group) did not receive radiation (sham source), whereas 39 vessels were irradiated. In the irradiated group, 48 edges (5 mm in length) were identified as noninjured, whereas 18 noninjured edges were selected in the placebo group. We compared the volumetric intravascular ultrasound measurements of the noninjured edges of the irradiated vessels with the fully irradiated nonstented segments (IRS, n=27) (26-mm segments received the prescribed 100% isodose) and the noninjured edges of the vessels of the placebo patients. The lumen decreased (6 mm(3)) in the noninjured edges of the irradiated vessels at follow-up (P:=0. 001). We observed a similar increase in plaque volume in all segments: noninjured edges of the irradiated group (19.6%), noninjured edges of the placebo group (21.5%), and IRS (21.0%). The total vessel volume increased in the IRS in the 3 groups. No edge segment was subject to repeat revascularization. CONCLUSIONS: The edge effect occurs in the noninjured margins of radiation source train in both irradiated and placebo patients. Thus, low-dose radiation may not play an important role in this phenomenon, whereas nonmeasurable device injury may be considered a plausible alternative explanation.

Angioplasty, Balloon↗