At least 1,333 records · Page 74Linked to original sources

Development of a HPLC-system for quantitative measurement of lidocaine and bupivacaine in patients plasma during postoperative epidural pain therapy.

A HPLC method was developed for the simultaneous quantitative analysis of lidocaine and bupivacaine in plasma, with bupivacaine serving as the internal standard for the assessment of lidocaine and vice versa. The samples are prepared by diethyl ether-extraction of the alkalified plasma and re-extraction using diluted sulphuric acid. This allows the elimination of interfering medication and plasma proteins. The prepared samples are chromatographed with a Merck LiChroCART Superspher 60 RP-select B cartridge column, the local anesthetics are detected using UV-photometry and the concentration is calculated by comparing the peak areas of the analyzed substance and the internal standard. Using a sample volume of 1 ml plasma, concentrations of approximately 2.5 micrograms/ml and 1 microgram/ml can be analyzed with a 95%-confidence interval of 2.5% or 5%, respectively. At higher or lower concentrations, accurate results can be obtained using smaller or larger plasma samples. The evolved analytical method allows the rapid and simple determination of lidocaine and bupivacaine plasma levels at a wide range of concentrations. It is suitable for research purposes as well as for routine analyses.

Analgesia, Epidural↗

Application of mixed mobile phases and a step gradient method in capillary electrochromatography for the separation of isomeric polycyclic aromatic hydrocarbon-deoxyribonucleoside adduct mixtures prepared in vitro.

Capillary electrochromatography (CEC) was used for the analysis of mixtures of neutral isomeric compounds derived from the reaction of carcinogenic hydrocarbon (benzo[g]chrysene and 5,6-dimethylchrysene) dihydrodiol epoxides with calf thymus deoxyribonucleic acid (DNA). The CEC analysis demonstrated higher resolution, greater speed and lower analyte consumption than high-performance liquid chromatography (HPLC) in the analysis of the same samples using the same type of stationary phase. Proper selection of the mixed mobile phases was critical for the separation of these complex mixtures with enhanced speed and selectivity. The use of a step gradient further improved the speed of the CEC analysis resulting in electrochromatograms that required only 25-70% of the corresponding HPLC analysis times.

DNA Adducts↗

Determination of albumin adducts of (+)-anti-benzo[a]pyrene-diol-epoxide using an high-performance liquid chromatographic column switching technique for sample preparation and gas chromatography-mass spectrometry for the final detection.

A novel method has been developed for the determination of (+)-anti-benzo[a]pyrene-diol-epoxide [(+)-anti-BPDE] albumin adducts in the low-picogram range. Blood from rats and humans was investigated for the validation of the method. Instead of the usual acid hydrolysis we used alkaline conditions for the cleavage of the esters formed with asparagic or glutamic acid residues of albumin. Alkaline hydrolysis gave rise to benzo[a]pyrene-r-7,t-8,t-9,c-10-tetrahydrotetrol (BT I-1) which was separated from the matrix by HPLC with a column switching technique. The analytes were collected by an automated fraction collector and after silylation determined with GC-MS using negative chemical ionization. Adduct concentrations were calculated by the internal standard method. Benzo[a]pyrene-r-7,t-8,c-9,c-10-tetrahydrotetrol (BT-II-2) was used as an internal standard because of its similar physicochemical properties and its absence from human samples. To determine the recovery of the analytical procedure benzo[a]pyrene-r-7,t-8,t-9,t-10-tetrahydrotetrol (BT I-2) was added at the end of the sample clean-up. Single ion recording mode was applied for the detection of the analyte and the standards using the abundant fragment ion m/z 284 for quantitation of the three tetrols. The mean recovery of the internal standard BT II-2 was about 50%. The limit of detection was 0.15 pg per injection corresponding to 0.01 fmol/mg albumin. Regression coefficients of the calibration curves were r2=0.99 and r2=0.98 for BT I-1 concentration ranges of 4-400 ng/l and 4-40 ng/l, respectively. The mean coefficient of variation for duplicate analyses of human albumin samples was found to be 22%.

Animals↗

Determination of phosphatidylcholine and disaturated phosphatidylcholine content in lung surfactant by high performance liquid chromatography.

A rapid isocratic method for determining the total phosphatidylcholine and disaturated phosphatidylcholine levels in lung surfactant preparations by high performance liquid chromatography (HPLC) is described. The analysis was performed on a 3.9 x 300 mm mu-Porasil column with detection by refractive index. The lipids were eluted with a solvent system of chloroform-acetonitrile-methanol-water-85% phosphoric acid 650:650:500:130:2 (v/v/v/v/v). A 4.6 x 30 mm silica guard column was used in place of an injector loop which served as a sample concentrator and purifier. Phosphatidylinositol, phosphatidylserine, phosphatidylethanolamine, and phosphatidylglycerol, all known components of lung surfactants, were eluted from the loop column and were prevented from reaching the analytical column. Sphingomyelin and lysophosphatidylcholine elute later than the phosphatidylcholines on the analytical column. The method was developed so that phosphatidylcholines elute as a single peak regardless of the fatty acid chain length (C12-C20). When the sample was first oxidized with a potassium permanganate-potassium metaperiodate solution, and potentially interfering oxidation products were removed by extraction into a basic aqueous phase, then only the disaturated phosphatidylcholines were analyzed.

Animals↗

Improved methods for determining the concentration of 6-thioguanine nucleotides and 6-methylmercaptopurine nucleotides in blood.

The conversion of the cytotoxic and immunosuppressive 6-mercaptopurine (6MP) to the active 6-thioguanine nucleotides (6TGN) is necessary for clinical efficacy of 6MP and its prodrug azathioprine. Another metabolite, 6-methylmercaptopurine nucleotide (6MMPN), is formed via a competing pathway by thiopurine methyl transferase. The concentrations of 6TGN and 6MMPN are measured in washed erythrocytes as a surrogate to the intracellular levels of these metabolites in the target tissues. Analysis of 6TGN and 6MMPN in multi-center clinical studies is more complicated because of the requirement to wash erythrocytes. In this investigation, we found no differences in the concentrations of 6TGN and 6MMPN in blood versus washed erythrocytes in samples obtained from patients taking therapeutic doses of oral 6MP or azathioprine for inflammatory bowel disease. We concluded that whole blood could be used for the analysis of these analytes, thus saving sample preparation time. We also found that the erythrocyte 6TGN concentration in blood at ambient temperature declined 2-4% per day, a loss that can be avoided by shipping blood samples frozen. The loss of 6TGN in blood stored at approximately -80 degrees C was 1% after 1 week and 12% after 24 weeks, indicating the analyte was moderately stable. 6MMPN in blood did not significantly change after 24 weeks of storage at approximately -80 degrees C. In addition, the sensitivity of the 6TGN assay was improved by modifying the HPLC conditions, which made the method more suitable for quantifying low levels of 6TGN in human intestinal biopsy samples and blood.

Chromatography, High Pressure Liquid↗

On-line sample preparation using restricted-access media in the analysis of the soy isoflavones, genistein and daidzein, in rat serum using liquid chromatography electrospray mass spectrometry.

Soy isoflavones are the subject of many investigations in experimental animals and humans regarding possible modulation of endocrine activity and chemoprevention of carcinogenesis. Genistein and daidzein, the principal biologically active isoflavones in soy, were measured using on-line solid-phase extraction (SPE) and liquid chromatography electrospray mass spectrometry (LC/ES-MS) detection in serum of rats consuming a common open-formula (NIH 31) chow that contained approximately 30 microg each of genistein and daidzein per gram of feed and a specially designed 'soy-free' chow that contained approximately 60-fold lower isoflavones. The use of a restricted-access/reverse phase trap cartridge and automated column switching permitted rapid and robust analytical performance with many injections of plasma onto a reverse phase LC column. Enzymatic deconjugation and a single centrifugation step were the only sample preparation steps required. The limit of detection for the isoflavones, based on the MS responses observed in serum from male and female rats consuming the soy-free chow, was 0.020 microM. The method, which uses deuterated isoflavones as internal standards, was determined to be accurate using spiked control serum (102-110% of added amounts) and precise using spiked control serum and incurred serum (<6% relative standard deviation). The average genistein and daidzein levels were determined in female (0.62 and 0.25 microM, respectively) and male rats (0.35 and 0.20 microM, respectively) consuming the standard diet. The sex difference observed for serum genistein concentrations was statistically significant (p < 0.0001). These results underscore the potential impact of standard open-formula diets on the results from rodent bioassays of biological activity.

Animals↗

Use of the airfuge for analysis and preparation of receptors incorporated into liposomes: studies with the receptor for immunoglobulin E.

A Beckman Airfuge has been employed for studying the interaction between lipids and the receptor for immunoglobulin E (IgE). For analytic experiments, samples were applied underneath a discontinuous sucrose gradient. After a 30-min centrifugation in a fixed-angle rotor, liposomes floated toward the top of the gradient whereas unincorporated receptor-IgE complexes remained at the bottom of the tube. Liposomes with incorporated receptors were also efficiently separated in the ACR-90 preparative rotor. These methods of "Airfuge flotation" can provide useful adjuncts to more traditional methods for density-gradient centrifugation especially when rapid analysis of small samples is desired.

Animals↗

Membrane-assisted solvent extraction of seven phenols combined with large volume injection-gas chromatography-mass spectrometric detection.

Membrane-assisted solvent extraction (MASE) was applied for the determination of seven phenols (phenol, 2-chlorophenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 4-chloro-3-methylphenol, 2,4,6-trichlorophenol and pentachlorophenol) with log Kow (octanol-water-partition-coefficient) between 1.46 (phenol) and 5.12 (pentachlorophenol) in water. The extraction solvents cyclohexane, ethyl acetate and chloroform were tested and ethyl acetate proved to be the best choice. The optimisation of extraction conditions showed the necessity of adding 5 g of sodium chloride to each aqueous sample to give a saturated solution (333 g/L). The pH-value of the sample was adjusted to 2 in order to convert all compounds into their neutral form. An extraction time of 60 min was found to be optimal. Under these conditions the recovery of phenol, the most polar compound, was 11%. The recoveries of the other analytes ranged between 42% (2-chlorophenol) and 98% (2,4-dichlorophenol). Calibration was performed using large volume injection (100 microL injection volume). At optimised conditions the limits of detection were between 0.01 and 0.6 microg/L and the relative standard deviation (n = 3) was on average about 10%. After the method optimisation with reagent water membrane-assisted solvent extraction was applied to two contaminated ground water samples from the region of Bitterfeld in Saxony-Anhalt, Germany. The results demonstrate the good applicability of membrane-assisted solvent extraction for polar analytes like phenols, without the necessity of derivatisation or a difficult and time-consuming sample preparation.

Automation↗

High-performance liquid chromatographic methods for the determination of cefpimizole in plasma and urine.

Quantitative analytical methods have been defined for the determination of cefpimizole, a new broad-spectrum cephalosporin antibiotic, in plasma and urine specimens. The methods employ ion-pair reversed-phase high-performance liquid chromatography with both ethylene-diaminetetraacetic acid (EDTA) and tetrabutylammonium hydroxide as pairing agents for separation and ultraviolet detection at 254 nm. Sample preparation for plasma aliquots consisted of acetonitrile protein precipitation followed by phase separation; the aqueous phase was filtered and assayed. For urine, sample preparation consisted of diluting an aliquot with chromatographic eluent, filtering, and assaying. The methods had a linear range of 17-0.3 micrograms/ml for plasma and 800-15 micrograms/ml for urine and had sufficient precision and accuracy to provide quantitative data. Stability studies in plasma and urine indicated that cefpimizole degraded rapidly at room temperature. Addition of EDTA to the physiological fluid substantially increased the stability at room temperature, and little or no degradation was observed in plasma or urine stored at -30 degrees C for over 100 days. Utility of the methods was demonstrated by assaying plasma and urine specimens obtained from a human volunteer receiving three dose levels. Estimates of various pharmacokinetic parameters are presented.

Cephalosporins↗

Determination of benzene residues in recycled polyethylene terephthalate (PETE) by dynamic headspace-gas chromatography.

A dynamic headspace-gas chromatography (HS/GC) method was developed to quantitate benzene in recycled PETE material derived from 21 PETE beverage bottles. The analytical system consisted of a purge-and-trap apparatus which was interfaced directly with a gas chromatograph/flame ionization detector. Cryofocusing and non-cryofocusing GC systems were used. The technique was applied to spiked PETE test samples which were prepared at various benzene concentrations ranging from 100 ppb to 117 ppm. The initial spiked benzene concentration in the PETE test samples was determined gravimetrically. The HS/GC technique was limited by the slow desorption rate of benzene from the PETE matrix; as a result, multipurges were performed at 60 degrees C. Regression analysis was done on the multipurge data to develop a desorption model which would predict the total amount of benzene in the PETE. The calculated results agreed with the experimental recoveries within +/- 10%. Recovery depended on the initial benzene level in the PETE and ranged from 70 to 90% after the first five purges.

Benzene↗

Specific detection of different plasma proteins in gel filtration fractions by solid phase enzymeimmunoassay (EIA).

An enzymeimmunoassay (EIA) is described enabling sensitive and specific immunodetection of different proteins in analytical and preparative fractionation of biological mixtures. The method is based on the ability of polystyrene to bind proteins and polypeptides. Commercially available rabbit antisera are used combined with the use of commercial alkaline phosphatase conjugated anti-rabbit-IgG antibodies. The good assortment of rabbit antisera available makes possible identification of hundreds of proteins in biological samples by the present method.

Animals↗

Use of rigid spherical inclusions in Young's moduli determination: application to DNA-crosslinked gels.

Current techniques for measuring the bulk shear or elastic (E) modulus of small samples of soft materials are usually limited by materials handling issues. This paper describes a nondestructive testing method based on embedded spherical inclusions. The technique simplifies materials preparation and handling requirements and is capable of continuously monitoring changes in stiffness. Exact closed form derivations of E as functions of the inclusion force-displacement relationship are presented. Analytical and numerical analyses showed that size effects are significant for medium dimensions up to several times those of the inclusion. Application of the method to DNA-crosslinked gels showed good agreement with direct compression tests.

Acrylic Resins↗

Hazardous anticancer drugs in health care: environmental exposure assessment.

Exposure of healthcare workers to anticancer drugs became problematic in the 1970s. Shortly thereafter, studies began documenting exposure of healthcare workers to these drugs. Investigations employing biological markers, such as urine mutagenicity, chromosomal aberrations, sister chromatid exchanges, and micronuclei, demonstrated associations between occupational exposures and elevated marker levels. Other analytical methods emerged to monitor workplaces where drugs were handled. These contemporary studies uncovered widespread contamination of drugs on work surfaces, trace amounts in air samples, and their presence in the urine of workers. Vials containing these drugs are often contaminated with the drug when they are shipped. Most workplace surfaces are contaminated with the drugs being prepared and used in that area. Other anticancer/hazardous drugs would most likely be used in these areas. The interior surfaces of biological safety cabinets and isolators, floors, countertops, carts, storage bins, waste containers, treatment areas, tabletops, chairs, linen, and other items are all potential sources of exposure to anticancer drugs. Patient body fluids contain the drugs and/or metabolites, often more biologically active than the parent compounds. An exposure assessment of areas where anticancer/hazardous drugs are handled must consider every potential source and route of exposure. Data from surface contamination and inhalation studies suggest that dermal exposure is the primary route of exposure. Assessment of exposure is the first step in providing a safe work environment for these workers. However, because of the many drugs to which they are exposed, any assessment can only be an estimation of the overall exposure.

Antineoplastic Agents↗

Simultaneous determination of eight vitamin D2 isomers by high-speed liquid chromatography.

The simultaneous determination of vitamin D2 and its isomers by high-speed liquid chromatography (HSLC) is described. Preferred operating conditions for the resolution and quantitation of vitamin D2 5,6-trans-vitamin D2, ergosterol, lumisterol2, isovitamin D2, isotachysterol2, tachysterol2, and previtamin D2 are as follows: column, "Zorbax" SIL (25 cm x 2.1 mm i.d.); pressure, 100-120 kg/cm2; temperature, ambient; detector, UV 254 nm; mobile phase, 0.15% methanol + 2% ether in pentane (for the simultaneous determination), 10% ether in hexane (for quantitation of the practical sets of isomers), or 55% CHCl3 (distilled) in pentane (for separation of isovitamin D2 and 5,6-trans-vitamin D2); sample size, 1 mul (greater than 1-5 ng); internal standard, p-cresol or alpha-naphthol. High-speed, good resolution, precise and accurate trace analysis, greater analysis flexibility, no necessity for preparing derivatives, and gentle operating conditions are main potential advantages of our method which has proved to be very efficient and surpasses all analytical procedures hitherto proposed.

Chemical Phenomena↗

Determination of liposome size distribution by flow cytometry.

BACKGROUND: An essential parameter that describes the quality of liposome suspensions is the mean size, respectively the size distribution. Currently several analytical methods including laser light scattering techniques (LLST) are being employed. METHODS: Here we present an alternative technique using flow cytometry (FCM) to characterize uni- and polydisperse suspensions. As model liposomes preparations containing dipalmitoylphosphatidylcholine (DPPC) were used. A constant number of particles (1,500/s) in the fluid stream and a representative number of 10,000 particles of each sample was measured. Fluorescence-labeled latex beads were measured identically, and their side scatter signals were calibrated and correlated to the results obtained with liposome vesicles. RESULTS: Evaluation of the measurement and validation of the FCM results in comparison to LLST confirm the reliability of results obtained with our method. Latex beads in the range of 100-1000 nm were used for calibration to classify liposomes. Although measurement characteristics and calculation in both methods are basically different, very good agreement of the results was achieved. CONCLUSIONS: Demonstration of stability, reproducibility, and reliability of results make the employment of this method acceptable for an adequate routine analysis technique.

1,2-Dipalmitoylphosphatidylcholine↗

[Simultaneous determination of various food additives by high performance liquid chromatography].

A novel method is proposed for the simultaneous separation and determination of eight food additives, acesulfame potassium (AK), aspartame (ASP), benzoic acid (BA), caffeine (CA), saccharin sodium (SA), sorbic acid (SOR), theobromine (TB) and theophylline (TP) by reversed-phase high performance liquid chromatography. The separation was achieved within 23 min by using an Alltech Econosphere C18 column with 10 mmol/L NaH2PO4(pH 4.00)-acetonitrile (90:10, V/V) as mobile phase. The qualification and quantitation were accomplished by using a photodiode array detector. The detection limits (S/N = 3) for all analytes were below mg/L level. Under the experimental conditions, other common food additives and organic acids such as cyclamate, citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various foods as well as pharmaceutical preparation, and the average recoveries for real samples ranged from 78.5% to 107.2%.

Benzoic Acid↗

Chromatographic separation of carotenoids.

The carotenoids are extremely reactive and consequently unstable due to their long system of conjugated double bonds. Several precautions, such as protection against light and oxygen, use of low temperature and antioxidants, analysis in the shortest possible time, should be taken during isolation and chromatography. The food samples, preferably fresh, are homogenized and immediately extracted with a suitable organic solvent. Saponification has been employed in order to hydrolyze the carotenoid esters, remove fatty material and destroy chlorophyll. This optional step facilitates subsequent carotenoid separation, identification and quantification. The separation of carotenoids is usually carried out by column chromatography, thin layer chromatography and high performance liquid chromatography, in analytical or preparative scale, on many stationary phases such as silica-gel, alumina, MgO, Ca(OH)2 and reversed-phase material (C18 and C30). The choice of the most suitable chromatographic method depends on the amount of sample, carotenoid composition, resolution, speed and purity required. Examples of carotenoid separation in different stationary phases will be shown and discussed.

Carotenoids↗

Fluorimetric liquid chromatographic analysis of amantadine in urine and pharmaceutical formulation.

A simple and sensitive liquid chromatographic method is described for the analysis of amantadine and memantine. The method is based on the derivatization of amantadine and memantine extracted from alkalified samples with (2-naphthoxy)acetyl chloride at mild conditions. The resulting derivatives were analyzed by isocratic HPLC with a fluorimetric detector (lambdaex, 227 nm; lambdaem, 348 nm). The linear range for the determination of amantadine or memantine spiked in urine (1.0 ml) was 1.0-10.0 nmol with a detection limit of about 0.2 nmol (S/N = 3; injected sample 20 microl). Only amantadine preparations are available on our local market, and application of the method to the analysis of amantadine in formulation and in the urine of a dosed subject was demonstrated and proved feasible. Quantitation of AT in tablets or capsules is capable in the linear range of 2.0-50.0 microM. Toluene was used as the solvent for extracting amantadine or memantine in samples and the resulting toluene extract was directly subjected to subsequent derivatization without solvent replacement leading to a simpler analytical procedure.

Amantadine↗